| 1 | Taking down carefully Old unsv TPN/SPN Distribution Box complete all as specified and as directed. |
| 2 | Taking down old and unserviceable sub main wiring and removing from the site and making good the disturbed surface complete all as specified and directed. |
| 3 | M&L for sub main wiring with 2 runs of 1.5 Sqmm, single core, PVC insulated & unsheathed cable, 1100 Volts grade, with multi stranded, copper conductor, drawn through existing concealed conduit/surface conduit with all fittings lugs of suitable size and connected to concerned MCB SP/DP/MCCB as required at site with one run of 1.5 Sqmm size PVC insulated copper conductor earth, complete all as specified and as directed. Note:-(Two run of cable along with earth conductor including PVC rigid conduit shall be measured as one RM length). |
| 4 | M&L for sub main wiring with 2 runs of 2.5 Sqmm, single core, PVC insulated & unsheathed cable, 1100 Volts grade, with multi stranded, copper conductor, drawn through existing concealed conduit/surface conduit with all fittings lugs of suitable size and connected to concerned MCB SP/DP/MCCB as required at site with one run of 2.5 Sqmm size PVC insulated copper conductor earth, complete all as specified and as directed. Note:-(Two run of cable along with earth conductor including PVC rigid conduit shall be measured as one RM length). |
| 5 | M&L for sub main wiring with 2 runs of 4 Sqmm, single core, PVC insulated & unsheathed cable, 1100 Volts grade, with multi stranded, copper conductor, drawn through existing concealed conduit/surface conduit with all fittings lugs of suitable size and connected to concerned MCB SP/DP/MCCB as required at site with one run of 4 Sqmm size PVC insulated copper conductor earth, complete all as specified and as directed. Note:-(Two run of cable along with earth conductor including PVC rigid conduit shall be measured as one RM length). |
| 6 | M&L for sub main wiring with 2 runs of 6 Sqmm, single core, PVC insulated & unsheathed cable, 1100 Volts grade, with multi stranded, copper conductor, drawn through existing concealed conduit/surface conduit with all fittings lugs of suitable size and connected to concerned MCB SP/DP/MCCB as required at site with one run of 6 Sqmm size PVC insulated earth copper conductor complete all as specified and as directed. Note:-(Two run of cable along with earth conductor including PVC rigid conduit shall be measured as one RM length). |
| 7 | M&L for sub main wiring with 2 runs of 10 Sqmm, single core, PVC insulated & unsheathed cable, 1100 Volts grade, with multi stranded, copper conductor, drawn through existing concealed conduit/surface conduit with all fittings lugs of suitable size and connected to concerned MCB SP/DP/MCCB as required at site with one run of 10 Sqmm size PVC insulated earth copper conductor complete all as specified and as directed. Note:-(Two run of cable along with earth conductor including PVC rigid conduit shall be measured as one RM length). |
| 8 | Supply and fix in replacement 4 way Vertical TPN (VTPN) Distribution Board , comprising a factory-built, surface or flush-mounted enclosure made of CRCA sheet steel with a powder-coated finish and IP 54 protection. The DB shall feature a triple-pole and neutral arrangement designed to accommodate a 4-pole MCCB/Isolator/RCCB as the incomer and single-pole or triple-pole MCBs as outgoers via a silver-plated electrolytic 250 Amp copper busbar system. The assembly must include necessary internal wiring, phase barriers, neutral links, earth bars, and a masked removable gland plate, all conforming to IS:13032 and IEC 61439 standards to ensure optimal phase segregation and circuit protection complete in all aspect all as specified and as directed.Make:- Indoasian OPTIPRO Cat Part no. 812040 / Havells / Legrand /Schneider |
| 9 | Supply and fix in replacement 8 way Vertical TPN (VTPN) Distribution Board , comprising a factory-built, surface or flush-mounted enclosure made of CRCA sheet steel with a powder-coated finish and IP54 protection. The DB shall feature a triple-pole and neutral arrangement designed to accommodate a 4-pole MCCB/Isolator/RCCB as the incomer and single-pole or triple-pole MCBs as outgoers via a silver-plated electrolytic 250 Amp copper busbar system. The assembly must include necessary internal wiring, phase barriers, neutral links, earth bars, and a masked removable gland plate, all conforming to IS:13032 and IEC 61439 standards to ensure optimal phase segregation and circuit protection complete in all aspect all as specified and as directed. Make:- Indoasian OPTIPRO Cat Part no. 812042 / Havells / Legrand /Schneider |
| 10 | Supply and fix in replacement 12 way Vertical TPN (VTPN) Distribution Board (Schneider/ Havells /ABB /L&T make), comprising a factory-built, surface or flush-mounted enclosure made of CRCA sheet steel with a powder-coated finish and IP54 protection. The DB shall feature a triple-pole and neutral arrangement designed to accommodate a 4-pole MCCB/Isolator/RCCB as the incomer and single-pole or triple-pole MCBs as outgoers via a silver-plated electrolytic 250 Amp copper busbar system. The assembly must include necessary internal wiring, phase barriers, neutral links, earth bars, and a masked removable gland plate, all conforming to IS:13032 and IEC 61439 standards to ensure optimal phase segregation and circuit protection complete in all aspect all as specified and as directed.Make:- Indoasian OPTIPRO Cat Part no. 812042 / Havells / Legrand /Schneider |
| 11 | S&F in replacement load line, 4-way TPN (Triple Pole and Neutral) Distribution Board, surface or flush-mounted on walls as per site requirements. The DB shall be constructed from heavy-gauge, CRCA sheet steel with a powder-coated finish, featuring a double-door configuration (IP43 protection) and a built-in copper busbar rated for 200A. The unit must include necessary internal wiring, neutral link, earth bar, and provision for a TPN MCB or Isolator as the incomer and SP/TP MCBs as outgoing ways, all complying with relevant IS/IEC standards and including all necessary hardware and earthing connections complete all as specified and as directed. Make:- Indoasian OPTIPRO Cat Part no. 811841 / Havells / Legrand /Schneider |
| 12 | S & F in replacement of a 16-Way SPN (Single Pole & Neutral) Double Door Distribution Board, constructed from 1.6mm thick powder-coated CRCA sheet steel, featuring an integrated or detachable cable extension box for organized wire dressing; the unit shall include a tinned copper busbar, neutral and earth links, masking plates, and knockouts, designed for surface or flush mounting in compliance with IEC 61439-3, excluding internal switchgear (MCBs/Isolators) which are measured separately complete in all aspect all as specified and as directed.Make- Schnider/Havells/L&T/ABB |
| 13 | S & F in replacement of a 12-Way SPN (Single Pole & Neutral) Double Door Distribution Board, constructed from 1.6mm thick powder-coated CRCA sheet steel, featuring an integrated or detachable cable extension box for organized wire dressing; the unit shall include a tinned copper busbar, neutral and earth links, masking plates, and knockouts, designed for surface or flush mounting in compliance with IEC 61439-3, excluding internal switchgear (MCBs/Isolators) which are measured separately complete in all aspect all as specified and as directed.Make- Schnider/Havells/L&T/ABB |
| 14 | S & F in replacement of a 8-Way SPN (Single Pole & Neutral) Double Door Distribution Board, constructed from 1.6mm thick powder-coated CRCA sheet steel, featuring an integrated or detachable cable extension box for organized wire dressing; the unit shall include a tinned copper busbar, neutral and earth links, masking plates, and knockouts, designed for surface or flush mounting in compliance with IEC 61439-3, excluding internal switchgear (MCBs/Isolators) which are measured separately complete in all aspect all as specified and as directed.Make- Schnider/Havells/L&T/ABB |
| 15 | S & F in replacement of a 04-Way SPN (Single Pole & Neutral) Double Door Distribution Board, constructed from 1.6mm thick powder-coated CRCA sheet steel, featuring an integrated or detachable cable extension box for organized wire dressing; the unit shall include a tinned copper busbar, neutral and earth links, masking plates, and knockouts, designed for surface or flush mounting in compliance with IEC 61439-3, excluding internal switchgear (MCBs/Isolators) which are measured separately complete in all aspect all as specified and as directed.Make- Schnider/Havells/L&T/ABB |
| 16 | M&L for comprehensive testing, health-check, and detailed reporting of the existing earthing system at precise locations within the BHDC, to be executed through the OEM or their authorized representative, i.e M/S ABB/ JMV/ TIRUPATI/ SN Engineers. The scope includes the measurement of earth pit resistance using calibrated digital earth testers, physical inspection of salt/charcoal or chemical fill levels, and verification of the integrity of all earth-to-equipment connections. A dedicated, structured report for each earthing station must be submitted, documenting current values against permissible standards and identifying any deficiencies. Should the inspection reveal the need for new earthing installations or major refurbishments, such work shall be measured and executed under the respective items of the schedule, ensuring the entire system is rendered complete and functional in all aspects as per technical specifications. |
| 17 | Material and labour for charging of earthing pits with high-conductivity Earth Enhancement Compound (low-resistance chemical backfill) in accordance with IS 3043; the process includes cleaning the pit, layering the charging materials around the earth electrode to ensure maximum surface contact, thorough watering and ramming to eliminate air gaps, and the final testing of earth resistance using a calibrated digital earth tester to achieve a value of less than 1.0 Ohm (or as per project design), including all necessary labor, tools, and water required for commissioning. |
| 18 | M&L for Plate Earthing Station conforming to IS:3043 standards, including excavation of earth pit (minimum size 0.6m x 0.6m x 3.0m deep), providing and fixing a 600mm x 600mm x 6 mm thick G.I. (Galvanized Iron) earth plate buried at a depth of 3 meters. The assembly shall include a 20mm diameter G.I. watering pipe with a funnel and wire mesh, protected by a medium-class G.I. pipe. The pit is to be filled with eco-friendly earth enhancement compound surrounding the plate to ensure low soil resistivity. The top of the pit shall be finished with a heavy-duty Cast Iron (C.I.) inspection cover and a brick masonry chamber (300mm x 300mm) with a cement plaster finish, including all necessary G.I./Copper nuts, bolts, and washers for conductor connection complete in all aspect all as specified and as directed. |
| 19 | M&L for Maintenance-Free Chemical Earthing System conforming to IEC 62561-7-2024/EN12457-2-2002 and IEC 62561-7-2024/ISO:4689-3-2017 standards to ensure a stable, low-impedance path to ground. The system shall feature a high-tensile, copper-bonded steel electrode (molecularly bonded with minimum 250-micron copper coating) of 17.2mm to 80mm diameter and 3000mm length, engineered to withstand high fault currents without thermal degradation. The installation involves boring a dedicated earth pit to be backfilled with an hygroscopic, non-leachable Earth Enhancement Compound (EEC) possessing a resistivity of less than 0.2 ohm meter, ensuring permanent moisture retention and soil conductivity enhancement regardless of seasonal variations. The scope includes all necessary exothermic welding or heavy-duty brass clamps for strip/cable connectivity, a heavy-duty Polypropylene or Pre-cast Concrete inspection chamber (rated for 5-10 tons), and final certification that the system achieves a resistance value of less than 1 ohm complete in all aspect all as specified and as directed. |
| 20 | NOTE:- All works described under Sr. No. 16 to Sr. No. 19 shall be got executed by M/S ABB/ JMV/ TIRUPATI/ SN Engineers. Accordingly, a MOU or a Letter of Intent must be established between the Bidder and M/S ABB/ JMV/ TIRUPATI/ SN Engineers. A signed copy of this document shall be uploaded as part of the tender documents. |
| 21 | Cutting chases, pinning in, including making good in cement mortar 1:3 including painting to match with the existing surface as in edges of landings, steps, cills, sunshades, shelves, lintels, etc; and for concealed conduit wiring, etc, cutting not exc10 cm girth complete all as specified and as directed. |
| 22 | Supply, fixing and connecting in replacement of Slim LED Batten 20 watt with Surface/Wall Mounted integrated LED 4 feet Fitting Polycarbonate housing and diffuser with viewing angle of 120 degree used to enhance the luman output Height suitable for White Housing & Isolated Electronic Driver, with Output Short-circuit protection, Surge Voltage protection up to 2.5 KV . Total system Lumen of 20W Led should be 2000 or above in Cool day Light(6500K), Power factor>0.9, CRI (Ra) >80, System with Average life of 50000 Burning hours complete with all accessories as required complete all as specified and as directed. |
| 23 | Supply, fixing and connecting in replacement recessed mounting back- lit LED 2'X2', 36 watt tile in CRCA housing with full opal diffuser suitable for Armstrong/ Grid Ceilings Type, size 595X595mm (Nominal),High lumen efficacy LED with viewing angle of 120 degree used to enhance the luman output Height suitable for White Housing & Isolated Electronic Driver, with Output Short-circuit protection, Surge Voltage protection minimum 2.5KV, safety & performance test as per IS:15885 Total system Lumen not less than 3600, in Cool day Light (6500K), Power factor>0.95, CRI (Ra) >80 with Average life of 50000 Burning hours complete with all accessories as required complete all as specified and as directed. |
| 24 | Supply, fixing and connecting in replacement recessed mounting back- lit LED 2'X2', 36 watt tile in CRCA housing with full opal diffuser suitable for Armstrong/ Grid Ceilings Type, size 595X595mm (Nominal),High lumen efficacy LED with viewing angle of 120 degree used to enhance the luman output Height suitable for White Housing & Isolated Electronic Driver, with Output Short-circuit protection, Surge Voltage protection minimum 2.5KV, safety & performance test as per IS:15885 Total system Lumen not less than 3600, in warm White (3000K), Power factor>0.95, CRI (Ra) >80 with Average life of 50000 Burning hours complete with all accessories as required complete all as specified and as directed. |
| 25 | Supply and installation of a suspended-type fabric sky ceiling light system, comprising a high-grade lightweight aluminum perimeter frame suspended via adjustable aircraft-grade stainless steel cables, integrated with high-output, flicker-free LED backlighting (6000K–6500K daylight spectrum) to ensure uniform, shadowless illumination. The system features a fire-retardant, UV-printed tension membrane fabric depicting high-resolution celestial or sky imagery, professionally stretched and secured using a silicone gasket (SEG) system for a seamless, drum-tight finish. The assembly includes all necessary dimmable constant-voltage drivers, mounting hardware, and electrical connectors, engineered to provide an architectural focal point that mimics natural skylights while meeting all relevant fire safety and electrical standards complete in all aspect all as specified and as directed. |
| 26 | M&L for careful removal of existing defective LED strips and associated internal wiring from the fabric light assembly, including the temporary dismantling and safe storage of the tension fabric membrane to access the lighting cavity. The scope includes the supply and installation of high-efficiency, constant-voltage LED flexible strips (typically 12V/24V, 6000K–6500K daylight CCT) with a high Color Rendering Index (CRI >90) and a minimum luminous efficacy of 100 lm/W. New strips must be meticulously arrayed and adhered to the internal housing at calculated intervals (pitch) to ensure perfectly uniform, shadow-free illumination without \\"hotspots\\" or \\"zebra patterns\\" visible through the fabric. The rate includes testing and commissioning of the new lighting, replacement of any faulty constant-voltage drivers (if required), rewiring of internal connectors using FRLS copper cables, and the professional re-tensioning of the fabric sheet using specialized spatulas to ensure a drum-tight, crease-free final finish complete in all aspect all as specified and as directed. |
| 27 | S&F in replacement LED driver, need to emphasize the technical compatibility and the labour required to access the internal components of the fabric system including the dismantling and safe handling of the existing tension fabric membrane to access the internal light box, followed by the identification, disconnection, and removal of the faulty LED driver and installation of a new, high-quality constant-voltage LED driver (12V/24V DC as per existing strip requirements) featuring a high power factor (PF >0.9), built-in short-circuit, over-load, and over-temperature protection, and compliance with IS 15885 standards complete in all aspect all as specified and as directed. |
| 28 | Spply and fix in replacement 800 Amp ,4Pole, 415 Volt, 50 Hz manual changeover switch (On load type) conforming to IS/IEC 60947-3 housed in vermin proof sheet steel enclosure(IP-43) complete with operating mechanism robust front-operated handle with clear \\"ON-OFF-ON\\" \\"I-O-II\\" position with silver -plated copper contacts with high short-circuit withstand capacity (20 ka for1 sec) with shrouded terminal suitable for aluminium termination with required busbar link complete in all aspect all as specified and as directed. Make Havells catpart no. IHCPFE0800 or equivalent in L&T / ABB |
| 29 | Spply and fix in replacement 630 Amp ,4Pole, 415 Volt, 50 Hz manual changeover switch (On load type) conforming to IS/IEC 60947-3 housed in vermin proof sheet steel enclosure(IP-43) complete with operating mechanism robust front-operated handle with clear \\"ON-OFF-ON\\" \\"I-O-II\\" position with silver -plated copper contacts with high short-circuit withstand capacity (20 ka for1 sec) with shrouded terminal suitable for aluminium termination with required busbar link complete in all aspect all as specified and as directed. Make Havells catpart no. IHCCFE0800 or equivalent in L&T / ABB |
| 30 | Spply and fix in replacement 400 Amp ,4Pole, 415 Volt, 50 Hz manual changeover switch (On load type) conforming to IS/IEC 60947-3 housed in vermin proof sheet steel enclosure(IP-43) complete with operating mechanism robust front-operated handle with clear \\"ON-OFF-ON\\" \\"I-O-II\\" position with silver -plated copper contacts with high short-circuit withstand capacity (20 ka for1 sec) with shrouded terminal suitable for aluminium termination with required busbar link complete in all aspect all as specified and as directed. Make Havells catpart no. IHCCFE0400 or equivalent in L&T / ABB |
| 31 | Spply and fix in replacement 250 Amp ,4Pole, 415 Volt, 50 Hz manual changeover switch (On load type) conforming to IS/IEC 60947-3 housed in vermin proof sheet steel enclosure(IP-43) complete with operating mechanism robust front-operated handle with clear \\"ON-OFF-ON\\" \\"I-O-II\\" position with silver -plated copper contacts with high short-circuit withstand capacity (20 ka for1 sec) with shrouded terminal suitable for aluminium termination with required busbar link complete in all aspect all as specified and as directed. Make Havells catpart no. IHCPFE0800 or equivalent in L&T / ABB |
| 32 | Spply and fix in replacement 630 Amp, 4-Pole Automatic Transfer Switch (ATS), with provision of Manual opertion including high-breaking capacity and motorized operation for seamless transitions between primary and secondary power sources (Utility/Generator). The unit shall include an integrated microprocessor-based controller for programmable voltage/frequency sensing, adjustable time delays, and mechanical/electrical interlocking to prevent simultaneous closing. The assembly must be housed in a Form 3b/4 compliant, IP43-rated sheet steel enclosure, complete with internal copper busbar extensions, neutral link, auxiliary contacts for remote monitoring, and clear status indication (Source 1/Source 2/Trip), all in accordance with IEC 60947-6-1 standards complete in all aspect all as specified and as directed. Make Havells catpart no. IHYFCDE630 or equivalent in L&T / ABB |
| 33 | Spply and fix in replacement 400 Amp, 4-Pole Automatic Transfer Switch (ATS), featuring high-breaking capacity and motorized operation for seamless transitions between primary and secondary power sources (Utility/Generator). The unit shall include an integrated microprocessor-based controller for programmable voltage/frequency sensing, adjustable time delays, and mechanical/electrical interlocking to prevent simultaneous closing. The assembly must be housed in a Form 3b/4 compliant, IP43-rated sheet steel enclosure, complete with internal copper busbar extensions, neutral link, auxiliary contacts for remote monitoring, and clear status indication (Source 1/Source 2/Trip), all in accordance with IEC 60947-6-1 standards complete in all aspect all as specified and as directed. Make Havells catpart no. IHYFCDE400 or equivalent in L&T / ABB |
| 34 | Spply and fix in replacement 315 Amp, 4-Pole Automatic Transfer Switch (ATS), featuring high-breaking capacity and motorized operation for seamless transitions between primary and secondary power sources (Utility/Generator). The unit shall include an integrated microprocessor-based controller for programmable voltage/frequency sensing, adjustable time delays, and mechanical/electrical interlocking to prevent simultaneous closing. The assembly must be housed in a Form 3b/4 compliant, IP43-rated sheet steel enclosure, complete with internal copper busbar extensions, neutral link, auxiliary contacts for remote monitoring, and clear status indication (Source 1/Source 2/ Trip), all in accordance with IEC 60947-6-1 standards complete in all aspect all as specified and as directed. Make Havells catpart no. IHYFCDE315 or equivalent in L&T / ABB |
| 35 | Spply and fix in replacement 250 Amp, 4-Pole Automatic Transfer Switch (ATS), featuring high-breaking capacity and motorized operation for seamless transitions between primary and secondary power sources (Utility/Generator). The unit shall include an integrated microprocessor-based controller for programmable voltage/frequency sensing, adjustable time delays, and mechanical/electrical interlocking to prevent simultaneous closing. The assembly must be housed in a Form 3b/4 compliant, IP43-rated sheet steel enclosure, complete with internal copper busbar extensions, neutral link, auxiliary contacts for remote monitoring, and clear status indication (Source 1/Source 2/ Trip), all in accordance with IEC 60947-6-1 standards complete in all aspect all as specified and as directed. Make Havells catpart no. IHYFCDE250 or equivalent in L&T / ABB |
| 36 | Supply and installation of IP65 (IEC 60529) Distribution Boards (Make: Hensel/ABB/Schneider), constructed from modular, high-quality polycarbonate enclosures. The units shall be shock-proof, rust-free, acid/chemical-resistant, and flame-retardant (self-extinguishing) in accordance with UL 94 V-2 and IEC 60695-2-1 (Glow Wire Test: 960°C). Enclosures must be halogen and silicon-free with a high-grade Polyurethane (PUR) gasket and a mechanical impact rating of IK 08 (EN 50298). The lid shall feature a quick-fastening spring mechanism.To mitigate condensation, the panel must include a passive \\"Dew Guard\\" system (operating range -30°C to +90°C) to regulate humidity without power consumption. The manufacturer shall provide CPRI/ASTA type test reports (IEC 61439-1 & 2) covering short-circuit withstand, temperature rise, and dielectric properties, along with routine test certificates.Manufacturer shall submit a copy of type test report (in accordance with ASTA certification by CPRI) of a board made out of Polycarbonate thermoplastic panel in accordance with IEC 60439-1 and IEC 61439-2 for power switchgear and control gear assembly. The agency must be submitted routine test certificate from Manufacturer Company in accordance with IEC 60439-1. The type test report as per CPRI (in accordance with IEC 60439-1) should consist with following: - i) Degree of protection of system. ii) Temperature Rise Limit. iii) Dielectric Properties. iv) Short Circuit Withstand Strength. v) Effectiveness of protective circuit. vi) Clearance and creepage distance. vii) Mechanical Operation. |
| 37 | Item No 36.00 Contd...........Type of Panel: Thermoplastic Polycarbonate. Degree of Protection: IP 65 System Voltage: 415V, 50Hz, 4Wire+E Cable (1) INCOMER SECTION :- Entry From TopIndoor/Wall Mounting. INCOMER: 250A FP 36kA MCCB: 1NoBusbar: 250A Copper. (2) METERING SECTION:-Multifunction meter (VOLTAGE CURRENT,KWH, POWER FACTOR, TOTAL LOAD)R,Y,B Indicating lamp: Each 1 No CT: 250/5A: 3 Nos Control fuse: 6 Nos (3) OUTGOING SECTION :-63A FP 10kA MCB- 8 Nos. 3 Phase ON/OFF Rotary Switch- 8 Nos. 6/16A 3PIN Domestic Socket: 16 Nos, |
| 38 | Supply and laying in replacement in trench of 1.1 kV grade heavy-duty industrial copper cable with stranded compact circular copper conductors. The cable shall be 6.0 sqmm, 4-core, insulated with XLPE (Cross-Linked Polyethylene) to withstand higher operating temperatures complete in all aspect all as specified and as directed. |
| 39 | Supply and laying in replacement 1.1 KV grade heavy-duty XLPE armoured Al cable with stranded compact circular conductors of size 50.0 sqmm, 3.5-core to withstand higher operating temperatures complete in all aspect all as specified and as directed. |
| 40 | Supply and laying in replacement 150mm x 50mm x 1.6mm thick perforated G.I cable tray properly fixed on wall with MS factory-fabricated brackets,including 10 mm dash fastner,coupler plates and GI hardware suitable for carry 50 sqmm XLPE armoured cable properly tie on the tray complete in all aspect all as specified and as directed. |
| 41 | S & F in Replacement MCCB 415 V, 160 Amps, 25 KA, 4 Pole complete all as specified and directed. |
| 42 | S & F in Replacement MCCB 415 V, 125 Amps, 25 KA, 4 Pole complete all as specified and directed. |
| 43 | S & F in Replacement MCCB 415 V, 100 Amps, 35 KA, 4 Pole complete all as specified and directed. |
| 44 | S & F in Replacement MCB TPN, 415 Volts, 125 Amps complete all as specified and directed. |
| 45 | S & F in Replacement MCB DP, 240 Volts, 40 Amps , 16 KA complete all as specified and directed. |
| 46 | S & F in Replacement MCB DP, 240 Volts, 63 , Amps , 16 KA complete all as specified and directed. |
| 47 | S & F in Replacement MCB SP, 240 Volts, 16 , Amps , 16 KA complete all as specified and directed. |
| 48 | S & F in Replacement MCB SP, 240 Volts, 10 , Amps , 16 KA complete all as specified and directed. |
| 49 | S & F in Replacement MCB SP, 240 Volts, 25 , Amps , 16 KA complete all as specified and directed. |
| 50 | S & F in Replacement MCB SP, 240 Volts, 32 Amps , 16 KA complete all as specified and directed. Please Enable Macros to View BoQ information |