| 1 | M&L for Anti termite Treatment of soil under existing floors using emulsion @ one litre per hole, 300mm apart including drilling and plugging 12mm dia holes with cement mortar 1:2 (1 cement: 2 coarse sand) to match the existing floors etc. complete all as specified and directed. |
| 2 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises/roughning the surfaces complete all as specified and directed. |
| 3 | M&L for vitrified tiles dark shade/double charged 8 to 10 mm thick area of each tile exc 0.42 sqm but not exc 1.00 sqm in floor/skirting etc set and jointed in neat cement slurry and pointed in white or coloured cement to match incl screed bed or bedding layer of mortar 15mm thick for laying floor finishes in CM (1:6) complete all as specified. |
| 4 | Taking down cement or lime plaster any description on brick or stone walls etc including recking out joints hacking for key scrubbing down with waters etc. |
| 5 | M&L for rendering 15 mm thick in cement mortor 1:4 on brick/ concrete surfaces with water proofing compound and finishing the surface even and fair without using extra cement complete all as specified directed. (wpc to be maesured and paid separately) |
| 6 | M&L for rendering 15mm thick cement plaster in cement mortar (1:6) finished even & smooth without using extra cement on brick/concrete surfaces complete all specified and directed. |
| 7 | M&L for Rendering 5mm thick with water proofing compound in cement mortar 1:3 on fare faces of brick work or concrete surfaces and finished the surface even and smooth without using extra cement in ceiling/ Chajjas complete all as specified. |
| 8 | Supply only liquid water proofing compound and to mixed as per manufacturer instruction complete all as specified. |
| 9 | M&L for prepration of new plastered surfaces and applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new/ Old surfaces. complete all as specified and directed. |
| 10 | M&L for preparing New plasteres surfaces of Wall and applying of Birla/JK white wall care putty approx 2 mm thick on Wall as per manufacturer's instruction on existing prepared surface and make the surface smooth by rubbing with sand papers etc and applying two coats of emulsion interior grade of asian/dulux/berger or equivalent as approved by GE over a coat of primer paint on Wall complete all as specified and directed. |
| 11 | M&L for preparing New plasteres surfaces of ceiling and applying of Birla/JK white wall care putty approx 2 mm thick on Wall as per manufacturer's instruction on existing prepared surface and make the surface smooth by rubbing with sand papers etc and applying two coats of emulsion interior grade of asian/dulux/berger or equivalent as approved by GE over a coat of primer paint on Wall complete all as specified and directed. |
| 12 | Complete removal of existing treatment of old surface of wall and applying 1mm thick putty again sanding and appying two coats of acrylic emulsion paint exterior grade over primer complete all as specified and directed by Engineer-in-Charge. |
| 13 | Complete removal of existing treatment of old surface of wall and applying 1mm thick putty again sanding and appying two coats of acrylic emulsion paint interior grade over primer complete all as specified and directed by Engineer-in-Charge. |
| 14 | Complete removal of existing treatment of old surface of ceiling and applying 1mm thick putty again sanding and appying two coats of acrylic emulsion paint interior grade over primer complete all as specified and directed by Engineer-in-Charge. |
| 15 | S&F in repair 10mm thick Toughned glass as in hinged doors, partitions automatic doors and similar work including cutting to shape, drilling holes required and finishing the surface even and smooth complete all as specified and directed. |
| 16 | S&F in repair Top patch (Model No-IPF-2 of make- Insta or equivalent as approved by GE complete all as specified and as directed. |
| 17 | S&F in repair Bottom Patch (Model No-IPF-3 of make- Insta or equivalent as approved by GE complete all as specified and as directed. |
| 18 | S&F in repair Top Pivot (Model No-IFC- GDP-105 of make -Insta or equivalent as approved by GE complete all as specified and as directed. |
| 19 | S&F in repair Bottom and Top corner patch lock (Model No-IPL- 1 of make- Insta or equivalent as approved by GE complete all as specifed and as directed. |
| 20 | S&F in repair Door handle H type 25x300mm (Model No-IGH- 55 of make. Insta or equivalent as approved by GE complete all as specified and as directed. |
| 21 | M&L for ETCHING on 10-12 mm thick TOUGHENED glass as per the design approved. NOTE: Unit rates are deemed to be including of necessary designing charges and all other required accessories complete all as specified and as directed. |
| 22 | M&L for Grinding, polishing /bevelling of edges on 10-12mm thick toughened glass complete all as specified and as directed. |
| 23 | S&F in repair for Double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty and fixed |
| 24 | Excavation in trenches not exc 1.5m wide and not exc 1.5m in depth foundation and getting out in any type of soil ,complete all as specified and directed. |
| 25 | Removing surplus excavated spoil to a distance not exc. 50m and depositing where directed at a level not exc 1.5m above the starting point complete. |
| 26 | Plain cement concrete 1:2:4 type B-1 (using 20 mm graded crushed stone aggregate) as in surface channels and drains complete, all as specified and directed. |
| 27 | Formwork to edges of concrete flats, breaks in floors, openings in concrete walls, floors and roofs and sides of RCC/PCC bands in walls, horizontal or sloping, and similar work all exceeding 20cm wide. |
| 28 | Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete,using extra cement,including form, moulds,mitred/stopped ends etc complete all as specified & directed. |
| 29 | M & L Extra for forming fair finished drain or channel 61.1 cm inner girth in cement concrete, using extra cement, including forms, moulds , mi-tred/ stopped ends etc. |
| 30 | S & F 300 mm Reinforced concrete pipes, Class NP2, laid and jointed complete with collers |
| 31 | M&L brick work with sub class' B' bricks of old size, straight or curved on plan exc 6 m mean radius built in cement mortar 1:6. |
| 32 | M & L rendering 10mm thick on brick wall or concrete surfaces in cement mortar 1:4 finished fair and even complete all as specified |
| 33 | Providing cement concrete 1:2:4 type B-1 using 20mm graded stone aggregate as in lintels upto 1.5m clear span, cills,steps,and other similar bands,plinth courses, string courses, lacing courses, parapets and railing upto 60cm height,copings,kneelers,apex stone,bed plates and the like including weathering slightly rounded or chamfered angles and throating, all as specified and directed. |
| 34 | M&L for concrete bed to drain pipe 300mm dia using cement concrete (1:4:8) type D-2 using 40mm graded stone aggregate, laid to falls including packing under and completely surrounding pipes witrh concrete after they are laid and tested |
| 35 | M&L for surface dressing not exc 15cm deep in soft/loose soil complete all as specified. |
| 36 | M&L for Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out, returning,filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, PCC 1:3:6 complete all as specified and directed by Engr-in-Charge |
| 37 | M&L for 0.50mm thick prepainted galvalume aluminium zinc coated GI based semi corrugated/profile steel sheeting of any colour, having tensile strength of 550MPA as in roof covering, wall cladding with self tapping screws or 'L' type of 'J' type or cranked hook bolts in lieu of screws as per manufacturers instructions including ridges as in roof coverings, complete all as specified and as directed. |
| 38 | S&F for Rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates complete all as specified and directed by Engineer-in-Charge. |
| 39 | M&L for preparation of new steel surfaces and applying two coat of synthetic enamel paint over a coat of red oxide primer on surfaces of any description, over 10cm in width or girth, not otherwise described. |
| 40 | M&L 150 mm thick for hard core broken stone or boulders of guage not exceeding 63 mm deposited spread & leveled in layer not exceeding 15cm thick,watered and rammed to a true surface complete all as specified and directed by Engr-in-charge. |
| 41 | M&L 100 mm thick PCC 1:3:6 type C-2 using 40 mm graded aggregate as in floor finished surface even complete all as specified and directed by Engineer-in-Charge. |
| 42 | M&L for Providing and laying PU coated 80mm thick factory made chamfered edge cement concrete paver block of M-30 grade with approved colour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of coarse sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with fine sand and cutting of paver block as per required size and pattern, finishing and sweeping extra sand; complete all as specified and directed. |
| 43 | M&L for sand Stone kerb of roughly squared stones of size 20cm x 30cm, dressed so that the maximum depression from a straight edge held against the dressed surface shall not exceed 6mm for top and exposed surfaces of sides and 20mm for the rest of surfaces jointed in cement mortar 1:6 and struck flush complete all as specified and directed. |
| 44 | S&F PVC wall Fluted or Louvers panels on walls duly fitted into each wall panels and wall panels interlock with each other along with fillet (if required at site) complete all as specified and directed by Engr-in-Charge. |
| 45 | S&F 300mm MS Helical door spring including roller & roller plate complete all as specified and as directed by Engineer-in-Charge. |
| 46 | S&F 1.25 mm lath thickness Steel rolling shutters, with out ball bearing, as specified including top cover, an choring rod, hasp and staple and one shop coat of primer; erected in position as indicated, complete with gear box and crank handle all as specified and directed by Engr-in-Charge. |
| 47 | S&F Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/Ceosetory windows & other Frames/ Chowkhat of size 65x125 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof,water/ moisture proof and fire retardantand fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. Note: (a) M.S. hold fast/ lugs or SS dash fasteners shall be paid for separately.(b) For WPC solid door/window frames, minus 5mm tolerance in dimension i.e. depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made. |
| 48 | S&F Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat of size 65x100 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof ,water/ moisture proof and fire retardantand fixed in position with MS hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. Note: (a) M.S. hold fast/ lugs or SS dash fasteners shall be paid for separately.(b) For WPC solid door/window frames, minus 5mm tolerance in dimension i.e. depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made. |
| 49 | S&F Factory made single extruded WPC (Wood Polymer Composite) solid moulded decorative type flush door shutter of size 30mm thick comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant. WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In- Charge. Note: stainless steel butt hinges and necessary S.S screws shall be paid separately. |
| 50 | S&F Factory made single extruded WPC (Wood Polymer Composite) solid glazed and skeleton / ss wiremesh (inclding ss wire mesh or glass ) door shutter of size 30mm thick comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant. WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In- Charge. Note: stainless steel butt hinges and necessary S.S screws shall be paid separately. |
| 51 | S&F stainless steel heavy dutty butt hinges 100mm long complete all as specified directed by Engr-in-Charge |
| 52 | S&F stainless steel handle brass finish 150mm size complete all as specified directed by Engr-in-Charge |
| 53 | S&F stainless steel Floor door stopper brass finish 125mm size fixed on bottom of door complete all as specified and directed. |
| 54 | S&F stainless steel barrel tower bolts brass finish 200mm size and fixed to shutter in vertical or horizontal position complete all as specified and as directed by Engineer-in-Charge. |
| 55 | Taking down chowkats or frames exc 1.5 sqm but not exc 4 sqm each with shutters (withour taking off shutters from the frame all as specified and directed by Engr-in-Charge. |
| 56 | S&F stainless steel sliding door bolts brass finish (250mm length of bolts) with bright bolt not less than 12mm dia including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate and fixed complete all as specified by Engineer-in -Charge. |
| 57 | M&L for point wiring concealed type with 1.5 sq mm Nominal cross sectional area, single core, 1100 Volt grade, multi stranded, PVC insulated, unsheathed FRLS copper conductor cable and connected to common earth and earth dollywith suitable copper lugs and drawing into and including rigid non-metallic PVC Concealed conduit of 20mm dia or higher, medium grade complete with and including all PVC conduit accessories and modular metal flush box,modular white cover plate with frame, blanking plate etc suitable for upto required module etc complete and making good disturbed surfaces to match theexisting for one light / bell / fan point controlled by one, one way switch 06 Amp, complete all as specified and as directed. |
| 58 | Supply, installation, testing, and commissioning of Heavy Duty Metallic Exhaust Fan having a 300 mm (appx 12-inch) sweep, complete with copper wound energy efficient electric motor, metallic blades, protective bird screen/grill, and louver assembly with min Air Delivery (min) 1200 to 1950 CMH (Cubic Meters per Hour) motor speed 1400 rpm ,energy efficient double ball bearing suitable for continous single phase 240 volt 50 Hz operation, corrosion resistance powder coated metallic construction complete in all aspect all as specified and directed. Make : Khaitan / Usha / Havells |
| 59 | Supply, installation, testing, and commissioning of Heavy Duty Metallic Exhaust Fan having a 380 mm (appox 15-inch) sweep, complete with copper wound energy efficient electric motor, metallic blades, protective bird screen/grill, and louver assembly with min Air Delivery (min) 3000 to 4500 CMH (Cubic Meters per Hour) motor speed 1400 rpm ,energy efficient double ball bearing suitable for continous single phase 240 volt 50 Hz operation corrosion resistance powder coated metallic construction complete in all aspect all as specified and directed.Make : Khaitan / Usha / Havells |
| 60 | Supply, installation, testing, and commissioning of Heavy Duty Metallic Exhaust Fan having a 450 mm (appox 18-inch) sweep, complete with copper wound energy efficient electric motor, metallic blades, protective bird screen/grill, and louver assembly with min Air Delivery (min) 5000 to 7000 CMH (Cubic Meters per Hour) motor speed 1400 rpm ,energy efficient double ball bearing suitable for continous single phase 240 volt 50 Hz operation corrosion resistance powder coated metallic construction complete in all aspect all as specified and directed. Make : Khaitan / Usha / Havells |
| 61 | Supply, installation, testing, and commissioning (SITC) of a Medium Duty Exhaust Fan having a 250 mm (approx. 10-inch) sweep, featuring a durable PVC/High-Grade Plastic body and blades complete with copper wound energy efficient electric motor, aesthetic grill/shutter, and external louver assembly for weather protection with min Air Delivery (min) 500 to 900 CMH (Cubic Meters per Hour) motor speed 1200 rpm ,energy efficient double ball bearing suitable for continous single phase 240 volt 50 Hz operation, complete all as specified and directed. Make : Khaitan / Usha / Havells |
| 62 | Supply, installation, testing and commissioning (SITC) of a High Efficiency BLDC (Brushless Direct Current) Ceiling Fan having a 1200mm (approx 48 inch) sweep, complete with motor, blades, canopy, downrod and a dedicated speed controller having power consumption rating less than 35 watt having air delicery greater than 220 CMM in copper winding complete for continous single phase 240 volt 50 Hz operation all as specified and directed by Engr-in-Charge. Make : Goldmedal/ Usha/ Havells.. |
| 63 | Supply & Fixing of wall mounted Fan 400 mm sweep suitable for operation on 230 V, 50 Hz single phase AC supply having speed min 1300 RPM and 60-70 CMM air delivery powered by copper wound energy-efficent capacitor start and run mortor with thermal overload protection with three blade aerodynamic design for low noise with pull cord or remote application for 3 step speed regulation enclosed by powder coted safety guard complete all as specified and directed by Engr-in-Charge. Make : Khaitan/ Usha/ Havells. |
| 64 | NOTE FOR ITEM NO 58.00, 59.00 & 60.00 1. The work includes careful, neat, and precise cutting of a suitable size circular or square opening in any type of wall (e.g., brick, block, RCC, drywall) using appropriate tools (e.g., core cutter, angle grinder, chisel).2. Making Good: The contractor shall be responsible for making good all resulting damages to the wall finish (e.g., plaster, paint, tile) around the newly cut opening, ensuring a seamless and neat finish flush with the surrounding wall surface. This includes patching and finishing the area where the fan frame meets the wall.3. Installation & Wiring: Installation of the fan unit securely using approved fasteners, providing necessary weather protection/sealing, and completing all electrical connections (1.5 sq.mm FRLS cable in conduit) from the nearest suitable point, including the necessary ON/OFF switch. Please Enable Macros to View BoQ information |