Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | SCH A PART-I : B/R PORTION (WATER PROOFING TREATMENT TO ROOF & SUNKEN FLOOR) |
| 2 | STAGE-IDismantling/taking down old existing unserviceable cement plaster loose/unsound weaken cement concrete of any description and in any position from existing external/internal surfaces of Reinforced Cement Concrete slab(Roof surface)/Reinforced Cement Concrete beam/ Reinforced Cement Concrete column/ Reinforced Cement Concrete lintels/Reinforced Cement Concrete facia/Reinforced Cement Concrete chajjas etc, (upto maximum height of 10 metres from natural ground level) with power driven pneumatic chisel and including removal of debris and washing down with water to remove dust, foreign items completeSTAGE-IIM&L applying two coats of epoxy based two component binder to bind old to new concrete chemical bond as per manufacturer's instructions and procedures complete STAGE-IIIM&L 25 mm thick average Plain Cement Concrete, 1:2:4 type B-0 (using 12.5 mm graded stone aggregate) as in padding concrete on roof over two coat of latex power at the ratio of 1:4:6 (Latex :Water: Cement) in a criss cross way complete [Note :- Second coat of latex is laid down minimum interval of 6-8 hours of first coat of latex and after second coat of latex immediate applied plaster work.] |
| 3 | item No. 1.001 Contd....STAGE-IVM&L rendering 10mm thick on fair faces on roof surfaces of concrete surfaces in cement mortar 1:3 finished even and fair including using water proofing compound admixture as per manufacturer's instructions, complete [Note :- WPC will be measured and paid separately under relevant item of schedule, complete all as specified and directed.]STAGE-VM&L providing water proofing treatment with a layer of APP based polymeric membrane 3mm thick minimum weighing 3.60kg/sqm reinforced with polyester non wove fabric (wt. not less than 160 gms/sqm) shall be applied over one coat of cold bituminous primer @ 0.40 ltr/sqm (membrane shall be laid using butane torch sealing all joints etc), complete all as specified and directed. [Note: The over lap shall be of minimum 75mm in longitudinal direction and 100mm on transverse direction]STAGE-VIM&L one coat of UV resistant bituminous aluminium paint over APP membrane complete all as specified and directed.[Note : Work shall be executed through specialist applicator/ agency] |
| 4 | M & L as per following stages complete all as specified and directed:STAGE-I: Providing and laying water proofing treatment of sunken portion of WCs, bathroom etc by applying cement slurry with acrylic based modified cementitious composite compound coating of make as approved in technical instruction 5/2003STAGE-II: First layer of slurry of cement @ 0.5 Kg/Sqm mixed with acrylic based polymer modified cementitious composite compounds @ 0.250 Kg/Sqm. This layer will be allowed to air cure for 4 hours.STAGE-III: Second slurry of cement @ 0.500 Kg/Sqm mixed with acrylic based polymer modified cementitious composite compounds @ 0.250 Kg/Sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours.STAGE-IV: 200 micron thick polythene film pasted with the help of bituminous adhesive shall be provided over treatment including provided spout pipe complete |
| 5 | M&L Cement concrete type E2 ,1:5:10 (using 40mm graded stone aggregate) in foundations, filling and mass concrete as in sunken portion area including demolition of old unserviceable concrete complete all as specified and directed. |
| 6 | SCH A PART-I : B/R PORTION (FINISHING WORK) |
| 7 | M&L Rendering 15 mm thick cement plaster in Cement Mortar 1:6 on fair faces of brick/concrete work surfaces finished even and smooth (without using extra lime or cement) including taking down old unserviceable cement plaster from brickwork, including raking out joints and hacking for key, cleaning down with water, complete all as specified and directed. |
| 8 | M&L rendering 20mm thick in Cement Mortar (1:4) in two layers {8mm thick in Cement Mortar (1:4) with approved water proofing compound as per manufacturing instruction over backing coat of 12mm thick in Cement Mortar (1:4)} on brick work or concrete surfaces including taking down old unserviceable cement plaster from brickwork including raking out joint and hacking for key, scrubbing down with water, complete all as specified and directed.[Note:- WPC will be measured and paid separately] |
| 9 | M&L rendering 5mm thick on fair faces of ceiling / chajja concrete surfaces in cement mortar 1:3 finished even and smooth (without using extra lime or cement) with chicken wire mesh including taking down old unserviceable cement plaster from brickwork, including raking out joints and hacking for key, cleaning down with water, complete all as specified and directed. |
| 10 | Supply only liquid water proofing compound, complete all as specified and directed. |
| 11 | M&L preparation of newly plastered surfaces of wall and applying two coat of oil bound distemper over one coat of alkali resistance primer over a coat of 1mm thick wall care putty complete all as specified and directed. |
| 12 | M&L preparation of newly plastered ceiling surfaces and applying three coat of white wash complete all as specified and directed. |
| 13 | M&L preparation of new plastered surfaces and applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces complete all as specified and directed. |
| 14 | M&L complete removal of existing treatment (any layers of existing treatment ) from walls/pillars/cornices by scraping down with using steel patti and mechanical sander machine (including provision of dust sucking) upto entire satisfaction of Engineer-in-charge, brooming and washing down with water including applying white cement based putty where required for filling to depressions to make the surface even and smooth by using sander machine (with provision of dust sucking) as directed by Engineer-in-charge, after preparing the surfaces applying two coats of distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer's specification complete all as specified and directed. |
| 15 | M&L complete removal of existing treatment (any layers of existing treatment ) from walls/pillars/cornices by scraping down with using steel patti and mechanical sander machine (including provision of dust sucking) upto entire satisfaction of Engineer-in-charge, brooming and washing down with water including applying white cement based putty where required for filling to depressions to make the surface even and smooth by using sander machine (with provision of dust sucking) as directed by Engineer-in-charge, after preparing the surfaces applying two coats of Finishing walls with textured exterior paint of required shade ,applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm complete all as specified and directed. |
| 16 | M&L preparation of new steel surfaces and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer of any description not otherwise described over 10cm width or girth complete all as spd and directed. |
| 17 | M&L preparation of newly wooden surfaces of any description not otherwise described over 10 cm girth or width and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed. |
| 18 | M&L preparation of old painted of steel surfaces of any description not otherwise described over 10 cm width or girth and applying one coat of synthetic enamel paint including steel stagings complete all as specified and directed. |
| 19 | M&L writing letters or figures (block, Roman, Italic or Indian) n exc 30 cm with synthetic enamel paint complete all as specified and directed. |
| 20 | SCH A PART-I : B/R PORTION (STRUCTURAL REHABITATION) |
| 21 | M&L Plain Cement Concrete 1:2:4 type B-1 (using 20mm graded crushed stone aggregate) as in floor, finished the surfaces fair & even to receive floor finishes including demolition of old unserviceable plain cement concrete, complete all as specified and directed. |
| 22 | M&L Reinforced Cement Concrete (design mix), M-25 (using 20mm graded stone aggregate) as in slab supported on wall, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like etc including demolition of old unserviceable reinforced cement concrete duly cutting reinforcement to facilitate demolition complete all as specified and directed. |
| 23 | M&L Reinforced Cement Concrete (design mix), M-25 (using 20mm graded stone aggregate) for chajjas including demolition of old unserviceable reinforced cement concrete duly cutting reinforcement to facilitate demolition complete all as specified and directed. |
| 24 | M&L TMT mild steel bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with the including mild steel wire (annealed) not less than 0.9mmdia or securing with clips complete all as specified and directed. |
| 25 | M&L TMT mild steel bars 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with the including mild steel wire (annealed) not less than 0.9mmdia or securing with clips complete all as specified and directed. |
| 26 | Use and waste of Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar works not exceeding 200mm thick (horizontal or sloping) surface of concrete flat with fair finished surfaces complete all as specified and directed. |
| 27 | Use and waste of Formwork to chullah hoods, chajjas, troughs and similar items including edges etc surface of concrete flat with fair finished surfaces complete all as specified and directed. |
| 28 | M&L 75 mm thick Plain Cement Concrete 1:3:6 Type C-2 (using 20 mm graded stone aggregate) as in plinth protection laid in alternate bays & joints should be filled with bituminous gola of 1 part of 85/25 bitumen and 2 part of heated sand incl finishing the surfaces fair and even including demolition of old unserviceable concrete complete all as specified and directed. |
| 29 | M&L providing cement concrete type B0 1:2:4 (using 12.5mm graded stone aggregate) as in coping to chajja tops and all other similar works complete all as specified and directed. |
| 30 | Excavation in trenches not exc 1.5m wide and not exc 1.5m deep for foundation etc or for shafts n.exc 10 Sqm on plan and n.exc 1.5m in depth and getting out in soft/loose soil complete all as specified and directed.[Total Qty: 32.00 (Part-I) + 69.00 (Part-III) + 493.00 (Part-IV) = 594.00] |
| 31 | Providing, erecting, maintaining temporary protective screens made out of UV stabilized, High density, high-strength, woven PVC coated, weight 650 GSM on the exterior of structures and the screen shall be secured using scaffolding materials (40mm, MS tubes, clamps) to form a robust framework ensuring it can withstand wind loads and keep debris within the work area and also maintain the screen in a tight, safe and serviceable condition throughout the project duration and removal after completion of work, fabric with all necessary fixing arrangement (galvanized iron eyelets spaced at regular intervals) and high strength PVC ropes a nilon ties for securing to the formation to ensure that it remains in position for the work duration as required.[Note : Unit rate includes all materials (fabrics, ropes, clamps, scaffoldings), labour for installation, maintenance throughout the contract period & dismantling and removal from site after completion] |
| 32 | Providing, mixing and applying bonding coat of approved adhesive on chipped portion of Reinforced Cement Concrete as per specification and direction of engr-in-charge in all respect & minimum Epoxy bonding adhesive 2.20 sqm/kg per coat of approved make, complete all as specified and directed. |
| 33 | Providing, mixing and applying SBR polymer (of approved make) modified cement mortar average thickness of 12mm in proportion of 1:4 (1 cement : 4 graded coarse sand with polymer minimum 2% by weight of cement used) as per specification, complete all as specified and directed.[Note :- Measurement and payment : the pre-measurement of thickness shall be done just after the surface preparation is completed and payment under this item shall be made only after proper wet curing has been done and surface has been satisfactorily evaluated by sounding/tapping with a blunt metal instrument and /or the 75mm size cube crushing strength at the end of 28 days to be not less than 30N/sqmm2).] |
| 34 | Shotereting Reinforced Cement Concrete of 25mm thick in mix grade M-25 with cement content not less than 330Kg/cum columns, beams and slabs etc in layers with approved design mix concrete having the specified minimum characteristic compressive strength (with ordinary portland cement, coarse sand and graded stone aggregate of 10mm maximum size in proportion as per design criteria) including the cost of centering and shuttering at edges and corners etc. complete all as specified and directed.[Note :- Rates shall include the providing necessary ground wires etc. The levelling gauges, if used, shall be paid for separately. Payment under this item shall be made only after proper wet curing has been done and surface has been satisfactorily evaluated by sounding/tapping with a blunt metal instrument.] |
| 35 | Shotereting Reinforced Cement Concrete of 50mm thick in mix grade M-25 with cement content not less than 330 Kg /Cum columns, beams and slabs etc in layers with approved design mix concrete having the specified minimum characteristic compressive strength (with ordinary portland cement, coarse sand and graded stone aggregate of 10mm maximum size in proportion as per design criteria) including the cost of centering and shuttering at edges and corners etc. complete all as specified and directed.[Note :- Rates shall include the providing necessary ground wires etc. The levelling gauges, if used, shall be paid for separately. Payment under this item shall be made only after proper wet curing has been done and surface has been satisfactorily evaluated by sounding/tapping with a blunt metal instrument.] |
| 36 | Shotereting Reinforced Cement Concrete of 75mm thick in grade M-25 with cement content not less than 330 Kg /Cum columns, beams and slabs etc in layers with approved design mix concrete having the specified minimum characteristic compressive strength (with ordinary portland cement, coarse sand and graded stone aggregate of 10mm maximum size in proportion as per design criteria) including the cost of centering and shuttering at edges and corners etc. complete all as specified and directed.[Note :- Rates shall include the providing necessary ground wires etc. The levelling gauges, if used, shall be paid for separately. Payment under this item shall be made only after proper wet curing has been done and surface has been satisfactorily evaluated by sounding/tapping with a blunt metal instrument.] |
| 37 | M&L removing of cavities roughening the smooth surface scrapping out/removing corrosion all loose/scale/rust etc from the visible reinforcement by applying rust remover @ 20 ml per sqm or as per manufacturer's instruction, rust removal and cleaning the steel reinforcement properly and then applying 40 micron thick dry thickness coat of epoxy zinc primer @ 250 ml per sqm or as per manufacturer' s instructions of exposed and new steel reinforcement (measured flat) complete all as specified and directed. |
| 38 | M&L providing and filling epoxy putty/Silicon sealant compound into Reinforced Cement Concrete/Plain Cement Concrete/Stone masonry crack after opening up Reinforced Cement Concrete/Plain Cement Concrete/Stone masonry cracks in V-groove manner approximate 10mm wide and 10mm deep using mechanical cutter, properly cleaning the same to remove loose dust, dirt, etc and finishing in line and level with existing concrete/masonry surface etc complete all as per manufacturer's instructions and procedures complete all as specified and directed. |
| 39 | Removing all disintegrated and loose concrete of any thickness including plaster if any in Reinforced Cement Concrete Column, Chajja, slab, beams, lintels etc, removing all loose rust/scale form exposed reinforcement bars by using wire brushes and sand paper including cleaning of exposed surfaces of reinforcement with protective anti corrosive epoxy bonding chemical and tied reinforcement bars/ IRC fabric 50mm X 50mm X 12gauge (2.05mm) if reqd to reinforcement concrete bonding primer uniformly to exposed surfaces and applying cement mortar 1:3:1 with MPC (1 Part cement : 3 Part Sand : 1 Part 6mm coarse aggregate) to an average thickness not less than 20 mm and removing debris outside MD land complete all as specified and directed.(Note : RIC 50x50x12 gauge or reinforcement bars shall be measured and paid separately) |
| 40 | Supply only GI chain link mesh size 50 x 50 mm with minimum dia. of wire 2.05 mm ,fixed to nuts and bolts , complete all as specified and directed. |
| 41 | Removing corroded worn out portion of reinforcement (when the area of bar as damaged by more than 25%) by cutting and replacing the new TMT bar of requisite diameter by binding or welding (whichever is effective for structure safety) with required lap/ welding with old bar including cost of reinforcement, including applying of rust remover chemical for protection of corroded rebar complete in all respect including removing unserviceable materials from site as per direction complete all as specified and directed.[Note :- Payment on weight (kg) of new reinforcement] |
| 42 | SCH A PART-I : B/R PORTION (SANITARY & PLUMBING) |
| 43 | S&F as in repairs vitreous China squatting pan, ' Orissa pattern, size 580 x 440 mm white, with integral footrests (excluding flushing cistern and flush pipe) including trap set in and including concrete complete all as specified and directed. |
| 44 | S&F as in repairs vitreous china wash down closet pan, white pedestal pattern pedestal pan and trap (excluding flushing cistern and flush pipe), connection to drain (or outgoing pipe) and to flushing pipe, antisyphonage pipe, etc and including plastic water closet seat, white, closed pattern with flat bottom, and cover and mild steel CP or aluminised hinging device complete all as specified and directed. |
| 45 | S&F in repairs vitreous china counter top wash hand basin (oval shape) colour brilliant / off white including fixing brackets and prepolished granite slab of size 1000 x 600mm size and cutting notch of required size as per the wash hand basin to be fixed in it complete all as specified and directed. |
| 46 | S&F in repairs 10 litre capacity PVC low level flushing cistern white with all accessories complete fixed with WC including syphon pipe, PVC flushing pipe of size complete (with brackets) incl flush pipe of polyethene of low or high density of PVC 32mm dia for low level cistern complete all as specified and directed. |
| 47 | S&F in repairs Vitreous China Urinal, Half stall type, white (excluding flushing cistern, flush pipe and waste pipe), with grating and union for discharge pipe(back or corner wall type), complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing automatic flushing cistern with brackets, flush pipe, grating and Union for discharge pipe complete all as specified and directed. |
| 48 | S&F in repairs Urinal Spreader of CP any colour for fixing with 15 mm dia pipe complete all as specified and directed. |
| 49 | S&F in repairs 8MM rectangular shaped urinal partition with frosted glass size 450 mm x 900 mm terminating about 40 cm above floor level and fixed with stainless steel clamp on wall complete all as specified and directed. |
| 50 | S&F in repairs toilet roll paper holder with flap of brass chromium plated including screw and chromium plate brass cleats complete all as specified and directed. |
| 51 | S&F in repairs for Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete in all respect as specified and directed. |
| 52 | S&F in repairs 15mm bore fancy type stop valve/angle cock (multiple) , chromium plated cast copper alloy, screwed down , high pressure , with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed, complete all as specified and directed. |
| 53 | S&F in repairs PVC connection 15mm size PTMT nuts of length 600mm complete all as specified and directed. |
| 54 | S&F in repairs 15mm bore long neck pillar taps cast copper alloy, with capstan heads, chromium plated, screwed down, fancy type high pressure, with or without lettered 'HOT or COLD' with long screwed sunk and fly nuts complete all as specified and directed. |
| 55 | S&F as in repaisr long neck bib taps cast copper alloy 15mm bore long neck body with fancy chromium plated screwed down, screwed for iron pipe or for brass ferrule, complete all as specified and directed. |
| 56 | S&F as in repairs CP grating square with waste hole 150mm size complete all as specified and directed. |
| 57 | S&F in repairs fancy type bevelled edge mirror of selected quality glass (Size- 1200mm x 750mm), mounted of 6mm thick AC building board with aluminium decorative frame and fixed to wooden plugs with chromium plated brass screws and cup, complete all as specified and directed. |
| 58 | S&F in repairs for Vitreous China white glazed fine clay laboratory sink , size 600x450mmx200mm including bedding in cement mortar on to dwarf walls, or including fixing cantilever brackets and connecting union to waste pipe including brackets complete all as specified and directed. |
| 59 | S&F as in repairs tubular towel rail brass chromium plated 20 mm dia `D' type 60 cm long between flanges complete all as specified and directed. |
| 60 | S&F in repairs stainless steel towel ring chrome finish complete all as specified and directed. |
| 61 | S&F as in repairs Sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long complete all as specified and directed. |
| 62 | Cutting chases, pinning in making good to facing on brick walls where required and pointing in cement mortar (1:3) to ends for concealed water tubing and making good, cutting n. exc. 10cm girth complete all as specified and directed. |
| 63 | S&F 20 mm outer dia medium grade CPVC, SDR 11 & plain CPVC SDR 11 with all fittings (brass inside the fittings) and fixed complete to walls and ceiling or laid in floors including taking down of old unserviceable existing pipe complete all as specified and directed. |
| 64 | S&F 25 mm outer dia medium grade CPVC, SDR 11 & plain CPVC SDR 11 with all fittings (brass inside the fittings) and fixed complete to walls and ceiling or laid in floors including taking down of old unserviceable existing pipe complete all as specified and directed. |
| 65 | S&F in repairs PVC SWR pipes 150 mm bore single socketed in any length with rubber ring joint fixed to wall with steel clamps for rain water pipes complete all as specified and directed. |
| 66 | S&F in repairs PVC SWR pipes 110 mm bore single socketed in any length with rubber ring joint fixed to wall with steel clamps all as specified and directed. |
| 67 | S&F in repairs PVC SWR pipes 75 mm bore single socketed in any length with rubber ring joint , laid in trenches or in floors complete all as specified and directed. |
| 68 | S&F PVC SWR bends of 150 mm bore complete all as specified and directed. |
| 69 | S&F PVC SWR bends of 110 mm bore complete all as specified and directed. |
| 70 | S&F PVC SWR bends of 75 mm bore complete all as specified and directed. |
| 71 | S&F PVC (SWR) junction single (single T) equal or unequal provided with access door of 110 mm dia complete all as specified and directed. |
| 72 | S&F PVC (SWR) floor trap plain including jointing with solvent cement of 75 mm dia complete all as specified and directed. |
| 73 | S&F PVC (SWR) vent cowl 110 mm bore complete all as specified and directed. |
| 74 | M&l PVC (SWR) gully trap 125/110 mm setting and jointing with solvent cement complete all as specified and directed. |
| 75 | SCH A PART-I : B/R PORTION (FLOORING) |
| 76 | M&L 25 mm thick Plain Cement Concrete 1:2:4 type B-0 (Using 12.5mm graded crushed stone aggregate) as in floor, finished the surfaces fair & even to receive floor finishes including demolition of old unserviceable concrete, complete all as specified and directed. |
| 77 | M&L Vitrified ceramic tiles light shade 10 mm thick (square/ rectangular) polished, area of each tiles exceeding 0.42 sqm but not exceeding 1.00 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match and including over screed bed or bedding layer of mortar 15 mm thick laying floor finished in Cement Mortar 1:6 including dismantling the old unserviceable existing tiles complete all as specified and directed. |
| 78 | M&L Vitrified ceramic tiles light shade 10 mm thick (square/ rectangular) polished, area of each tiles exceeding 0.42 sqm but not exceeding 1.00 sqm, on vertical surface such as skirtings etc. set and jointed in cement slurry over 10 mm thick rendering in Cement Mortar 1:3 including dismantling the old unserviceable existing tiles complete all as specified and directed. |
| 79 | M&L Non Skid coloured ceramic tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.18 Sqm but not exc. 0.38 Sqm, in floors etc. Set and jointed in neat cement slurry and pointed in white or coloured cement to match and including over screed bed or bedding layer of mortar 15 mm thick laying floor finished in Cement Mortar 1:4 including dismantling the old unserviceable existing tiles complete all as specified and directed. |
| 80 | M&L Glazed ceramic tiles Coloured 450 x 300mm 7 to 8 mm thick in wall/dado etc, set & jointed in neat cement slurry & pointed in white or coloured cement to match rendering over 10 mm thick in Cement Mortar 1:3 on masonry surfaces or surfaces other than fair face of brick work/ concrete surfaces including dismantling the old unserviceable existing tiles complete all as specified and directed. |
| 81 | M&L 16-18 mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window- cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite of any type of work and including over screed bed or bedding layer of mortar 15 mm thick laying floor finished in Cement Mortar 1:4 including dismantling the old unserviceable existing stonework complete all as specified and directed. |
| 82 | Rounding to edges of stone slabs exposed edge, such as in steps, cooking platform and other similar situation complete all as specified and directed. |
| 83 | M&L pre-polished machine cut kota stone slab flooring 18-20mm thick, laid over and including 20mm thick screed bed in cement mortar 1:6 base, laid and jointed with grey cement slurry mixed with pigment to match the shade of slab including cutting, rubbing & mirror polishing, including dismantling the old unserviceable existing stonework, complete all as specified and directed.[Note:- The size of kota stone slab not less than 550mmx550mm] |
| 84 | M&L pre-polish kota stone slab 15-16mm thick in riser of steps, skirting, dado and pillar laid over cement screed and jointed with grey cement slurry mixed with pigment to match the shade of slab including cutting, rubbing & mirror polishing, over 10mm thick in cement mortar 1:3 including dismantling the old unserviceable existing stonework complete all as specified and directed. |
| 85 | M&L Grinding & Polishing for old existing kota stone slab flooring until mirror finish, complete all as specified and directed. |
| 86 | SCH A PART-I : B/R PORTION (CEILING/ JOINERY/ BUILDERS HARDWARE) |
| 87 | Dismantling of Wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/ blankets, any thickness, including cover fillets and S&F powder coated aluminium snap grid (Size= 605mmx 605mm) frame work for false ceiling including Hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long complete including S&F for 6mm thick non asbestos fibre cement building boards fixed or laid/ inserted to timber/GI/Aluminium framework with screws as in ceiling complete all as specified and directed. |
| 88 | Taking down chowkats or frames exc 1.5 sqm but n. exc 4 sqm each with shutters (without taking off shutters from the frame) complete all as specified and directed. |
| 89 | Taking down of chowkats or frames not exc 1.5sqm each with shutters (without taking off shutters from frames ) complete all as specified and directed. |
| 90 | S & F Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S Square tube, suppling & fixing in opening as per specification & drawing complete all as specified and directed. |
| 91 | S&F Factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails, M.S. frame shall be covered with heat moulded palin colour PVC `C' channel heaving a PVC sheet strip of 20mm width suck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S frame wedded/ sealed to the stiles, & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing complete all as specified and directed. |
| 92 | M&L chowkhat 2nd class hard wood plain, solid, straight, chowkhats and and frames wrought , framed rebated on the solid rounded or chamfered, put together with glue pinned at joints complete all as specified and directed. |
| 93 | S&F 30 mm thick Flush shutters ,solid core construction ,with block board core and plywood face panels, commercial type on both sides complete all as specified and directed. |
| 94 | S&F MS flat iron as in hold fast clamps small articles conforming to Fe-290 Gde-E-165 complete all as specified and directed. |
| 95 | M&L Plain Cement Concrete (1:2:4) type B-0 as in bed blocks for hold fast including necessary formwork complete all as specified and directed. |
| 96 | S&F 18/19 mm thick, prelaminated PVC solid cupboard cabinet shutter full size fitted to cupboards including hinges as required, 2 Nos handles (50mm to 65mm) and supply and fixing 2 Nos ball catches 140mm with 8mm dia steel ball and brass body and striking plate including all frame work including dismantling old unserviceable existing boarding complete all as specified and directed. |
| 97 | S&F 18/19 mm thick, prelaminated PVC solid shelves and drawers boxes fitted under cooking platform and other platforms including 2 Nos telescopic channel, 1 No handles (50mm to 65mm) and fixing with all frame works including dismantling old unserviceable existing boarding complete all as specified and directed. |
| 98 | S&F & Providing and fixing Powder coated aluminium (minimum thickness of powder coating 50 micron) frame work for doors, windows, ventilators and partitions (Fixed portions) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ panelling, C.P. brass/ stainless steel screws, all complete as per architectural drawings complete all as specified and directed. |
| 99 | S&F& Providing and fixing Powder coated aluminium (minimum thickness of powder coating 50 micron) for shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/neoprene gasket required (Fittings shall be paid for separately) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ panelling, locking arrangement ,C.P. brass/ stainless steel screws all complete as per architectural drawings complete all as specified and directed. |
| 100 | S&F framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 , the grill shall be inserted in the wall surface including necessary drilling and grouting with cement etc complete all as specified and directed. |
| 101 | M&L & providing and fixing stainless steel (Grade 304) (Sch10S) railing in staircase made of hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (where ever required) and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of floor or the side of waist slab with suitable arrangement complete all as specified and directed. |
| 102 | S & F stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.18mm and fixed with stainless steel wire staples complete all as specified and directed. |
| 103 | S&F 4mm thick sheet glass, ordinary quality and glazing with rubber packing/ snap aluminium beading etc for fixing of glass pane in square n. exc 0.5 Sqm in each pane, complete all as specified and directed. |
| 104 | S&F 4mm thick figured glass, pin head type and glazing with rubber packing/ snap aluminium beading etc for fixing of glass pane in squares n exc 0.5 sq. m in each pane complete all as specified and directed. |
| 105 | S&F 100mm long butt hinges, extruded stainless steel with s/s steel hinge pin with ISI mark and fixed , type B-21 complete all as specified and directed. |
| 106 | S&F 75mm long butt hinges, extruded stainless steel with s/s steel hinge pin with ISI mark and fixed , type C-21 complete all as specified and directed. |
| 107 | S&F aluminium anodised 150 mm barrel tower bolts of extruded section(ISI Mark) complete all as specified and directed. |
| 108 | S&F aluminium anodised 100mm barrel tower bolts of extruded section (ISI Mark) complete all as specified and directed. |
| 109 | S&F 150 mm long aluminium alloy handles, fabricated type, anodised (ISI Mark) complete all as specified and directed. |
| 110 | S&F 100 mm long aluminium alloy handles, fabricated type, anodised (ISI Mark) complete all as specified and directed. |
| 111 | S&F 300 mm long aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy and fixed (ISI Mark) complete all as specified and directed. |
| 112 | S & F 75 mm long hasp and staple, aluminium anodized with bolt to hinge plate and fixed with screws complete all as specified and directed. |
| 113 | S & F Ball catches with 8mm dia steel ball, and brass body and striking plate including letting in and fixed complete all as specified and directed. |
| 114 | S&F 150mm long floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor complete all as specified and directed. |
| 115 | S&F 300 mm mild steel ordinary rat tail rod pattern spring including roller and sollar plates complete all as specified and directed. |
| 116 | S&F in repairs Harrison curtain rails, mild steel 25mm dia, chromium plated with number conical end balls suitable for fixing as end of curtain/drapery rods complete all as specified and directed. |
| 117 | SCH A PART-I : B/R PORTION (BRICKWORK) |
| 118 | M&L old size brick work with fly ash bricks straight or curved on plan exc 6 m mean radius build in Cement Mortar 1:6 including demolition of old existing unserviceable brickwork complete all as specified and directed. |
| 119 | M&L old size brick work straight or curved on plan exc 6 m mean radius build in Cement Mortar 1:6 including demolition of old existing unserviceable brickwork complete all as specified and directed. |
| 120 | M&L brick work with half bricks thick fly ash bricks straight or curved on plan exc 6 m mean radius build in Cement Mortar 1:4 including demolition of old existing unserviceable brickwork complete all as specified and directed. |
| 121 | SCH A PART-I : B/R PORTION (SEWAGE DISPOSAL & MISC ITEMS) |
| 122 | S&F in repairs for Gun metal gate valve,20 mm boreClass-I (Grade-I) PN-10 (IS:718), cast copper alloy screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for unions complete all as specified and directed. |
| 123 | Removal of plants of girth exc 5.0 Cement Mortar and n.exc 30 Cement Mortar including root from Reinforced Cement Concrete/Brick surfaces, pouring of acid chemical over root are of concrete surface and making in Cement Mortar 1:3 or Plain Cement Concrete 1:2:4 type B0 using 12.5mm graded stone aggregate including all accessories to reach the area of plant growth in buildings etc complete all as specified and directed. |
| 124 | S&F Joist channel angle of tee section fixed independently without connecting plate as Fe 410 W (Gde-E-250 quality B) including dismantling of old unserviceable wrought iron complete all as specified and directed. |
| 125 | M&L Plain Cement Concrete 1:3:6, type C1(using 40 mm graded stone aggregate) as in foundation filling and mass concrete complete all as specified and directed. |
| 126 | M&L in repairs Cement concrete 1:2:4, type B-1(using 20mm graded stone aggregate) in surface channels and drains, RWP's Plain Cement Concrete shoes and Manholes complete all as specified and directed. |
| 127 | M&L Extra for forming 40 cm inner girth fair finished drains or channels i.e. exc 30cm inner girth in cement concrete using extra cement including forms, moulds, mitred/ stopped ends etc complete all as specified and directed. |
| 128 | M&L concrete bed to 150mm dia drain pipes including packing under, and haunching against the sides of pipes after they are laid and tested in Plain Cement Concrete 1:3:6 type C2 (using 40mm graded stone aggregate) including demolition of old unserviceable drain pipe alongwith cement base and haunching complete all as specified and directed. |
| 129 | Supplying and laying UPVC Eco drain Hi-tech pipe drainage sewer system pipe bearing 160mm dia minimum 4mm thick including jointing with coupler,bend tee as per site requirement complete laid in trenches or floors complete all as specified and directed. |
| 130 | M&L in repairs precast cement concrete Type A-1,1:1.5:3 (using 20mm graded crushed stone aggregates) set in Cement Mortar 1:4 as in manhole cover etc complete all as specified and directed. |
| 131 | SCH A PART-II : INTERNAL ELECTRIFICATION |
| 132 | Taking down carefully aluminium conductor point wiring (light, fan, socket or power) complete including fittings such as switches, ceiling roses, pendants, regulators ,sockets etc. and removing (except those to be reused shall be kept in safe custody at the site ) and making good disturbed surfaces of walls, floors etc.to match with the existing complete all as specified and directed. |
| 133 | M&L point wiring for light point/ fan point, one light/fan/exhaust fan point controlled by one, one way switch using 1.5 sqmm nominal cross sectional area multistranded copper conductor ,PVC insulated unsheathed FRLSH cables in and including 20 mm dia or higher size PVC concealed conduits and fittings of medium grade, including pressed steel terminal switch boxes/ modular, 3 mm thick bakelite sheet top cover (ISI Marked) fitted with chromium plated brass screws & washers and 1.5 sqmm nominal cross sectional area multistranded copper conductor FRLSH PVC insulated unsheathed earth wire and connecting to earth dolly and brass screws, washers etc. testing complete all as specified and directed. |
| 134 | All as per item No.2.002 above but 5 Amp socket on same board with other switches complete all as specified and directed. |
| 135 | All as per item No.2.002 above but 5 Amp socket on Independent board with other switches complete all as specified and directed. |
| 136 | All as per item No.2.002 above but 5 Amp Calling bell point with other switches complete all as specified and directed. |
| 137 | All as per item No.2.002 above but 5 Amp Two way point with other switches complete all as specified and directed. |
| 138 | M&L point wiring for socket outlet 3 pin, 15 amps on independent Boards controlled by one, one way switch using 2.5 sqmm nominal cross sectional area multistranded copper conductor, PVC insulated unsheathed FRLSH cables in and including 20 mm dia or higher size medium grade PVC concealed conduits and fittings, including pressed steel terminal switch boxes , 3 mm thick bakelite sheet top cover (ISI Marked) fitted with Chromium plated brass screws & washers and 2.5 sqmm nominal cross sectional area multistranded copper conductor , PVC insulated unsheathed FRLSH cable earth wire and connecting to earth dolly and brass screws, washers etc. testing complete all as specified and directed. |
| 139 | M&L point wiring for socket outlet 3 pin, 15 amps on independent Boards controlled by one, one way switch using 4.0 sqmm nominal cross sectional area multistranded copper conductor, PVC insulated unsheathed FRLS cables in and including 20 mm dia or higher size medium grade PVC concealed conduits and fittings, including pressed steel terminal switch boxes , 3 mm thick bakelite sheet top cover (ISI Marked) fitted with Chromium plated brass screws & washers and 4.0 sqmm nominal cross sectional area multistranded copper conductor , PVC insulated unsheathed FRLSH cable earth wire and connecting to earth dolly and brass screws, washers etc. testing complete all as specified and directed.[Note : Total Qty 14.00 (Part-II) + 16.00 (Part-IV) = 30.00] |
| 140 | S&F switch piano flush type, single pole , 5/6 Amps, one way complete all as specified and directed. |
| 141 | S&F Bell switch piano flush type, single pole , 5/6 Amps, one way complete all as specified and directed. |
| 142 | S&F switch piano flush type, single pole , 6/16 Amps, Two way complete all as specified and directed. |
| 143 | S&F socket outlet 2 in 1 multipurpose 5 pin , (6 Amps ) flush type controlled by one switch duly marked complete all as specified and directed. |
| 144 | S&F switch socket combination 2 in 1 multipurpose 5 pin , (6 Amps ) flush type controlled by one switch complete all as specified and directed. |
| 145 | S&F Bell multi music type, AC 230 Volts, single pole 230 volts complete all as specified and directed. |
| 146 | S&F ceiling rose surface bakelite 45 mm x 50 mm three terminal suitable for 230 Volts AC 6 Amps complete all as specified and directed. |
| 147 | S&F stepped type electronic fan regulator, minimum 5 steps, flush type 240 Volts ISI marked complete all as specified and directed. |
| 148 | S&F lamp holder, polycarbonate body with back plate straight or angular suitable for batten fittings complete all as specified and directed. |
| 149 | S&F sheet metal enclosure with 20 Amp MCB and two pin and earth plug and socket complete with one single pole MCB complete all as specified and directed.[Total Qty : 14 (Part-II) + 16.00 (Part-IV) = 30.00] |
| 150 | M&L in repairs sub-main wiring with two run of FRLSH PVC insulated unsheathed single core multi-stranded copper conductor of size 4 sqmm and one run of 2.5 sqmm copper conductor as continuity earth wire drawn in and including PVC conduit concealed (medium grade) of suitable size but not less than 20 mm dia on wall / floor etc, including PVC fittings such as bends Tee and boxes including taking down old unserviceable sub main wiring complete all as specified and directed.[Note : Two run of 4 sqmm cable, one run of 2.5 sqmm cable, one run of PVC conduit shall be measured and paid as one unit] |
| 151 | S&F in repairs submain wiring two single core ,6 sqmm nominal cross sectional area multistranded copper conductor FRLSH cable, PVC insulated unsheathed 1100 Volts grade drawing in and including suitable size PVC conduit (ISI marked)(medium grade), concealed, including 6 sqmm nominal cross sectional area multistranded copper conductor FRLS cable, PVC insulated unsheathed 1100 Volts grade earth wire complete all as specified and directed.[Note : Three run of 6.00 sqmm cable alongwith PVC conduit shall be measured and paid as one unit] |
| 152 | S&F in repairs wall security light fittings 35 watts 230v, minimum lumen output 100 lumen/Watt, made up of pressure dia cast housing with prismatic polycarbonate diffuser and individual LED with secondary optic and IP65/66 including necessary connection complete with all accessories including connected with 3 core copper cable of suitable 1.5 sqmm size complete all as specified and directed. |
| 153 | S&F LED light fitting 1x9W/1x10W bulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable complete all as specified and directed. |
| 154 | S&F in repairs 10 W LED light fitting mirror type 2',220volt AC lighting fixture with complete all accessories and connection from ceiling rose with twin core twisted flexible copper conductor cable with suitable size and earthing complete all as specified and directed. |
| 155 | S&F LED light fitting 1 x 20 watt box type with same make LED tube rod side connection AC decorative box type 4' long wih driver, holder including LED tube connecting up with complete all accessories and connection from ceiling rose with twin core twisted flexible copper conductor cable with suitable size and earthing complete all as specified and directed. |
| 156 | S&F recessed mounted 2' x 2' LED luminaire 36 watt, 6000K (Cool white) for grid ceiling minimum lumen output 100 lumen/watt pre-treated CRCA frame powder coated with diffused profiled including necessary connection complete all as specified and directed. |
| 157 | S&F in repairs 12 watt surface mounted round LED Down light Colour (CW) aesthetically designed made by aluminium P-die-cast enclosures, with separate replaceable constant current driver 12 watts for grid ceiling including electrical connection complete all as specified and directed. |
| 158 | S &F energy efficient mettalic, powder coated Exhaust fan, steel body AC single phase. Operating voltage 220- 240 Volt, frequency 50Hzs, having blade sweep 300 mm ,1350-1400 RPM air delivery not less than 1160-1600 CMH ,supply complete with louvers and frame fixed with suitable size GI bolts, nuts and washers duly grouted and connecting up with 0.75 Sq.mm size 3 core PVC insulated flexible cable with multistranded copper conductor from ceiling rose to connector of exhaust fan complete all as specified and directed. [Note: Purchase voucher and warranty certificate to be produced for claiming of payment] |
| 159 | S &F energy efficient mettalic, anti dust powder coated,Exhaust fan, steel body, 4 blade, AC single phase. Operating voltage 220- 240 Volt, frequency 50Hzs,1400RPM having blade sweep 450 mm , air delivery not less than 6120 CMH ,supply complete with louvers and frame fixed with suitable size GI bolts, nuts and washers duly grouted and connecting up with 0.75 Sq.mm size 3 core PVC insulated flexible cable with multistranded copper conductor from ceiling rose to connector of exhaust fan complete all as specified and directed. [Note: Purchase voucher and warranty certificate to be produced for claiming of payment] |
| 160 | S&F in repairs 240V, 10 KA 'C' curve miniature circuit breaker (MCB) of single poles and current carrying capacity 5 to 32 AMP, in the MCB DB Complete with connection testing and commissioning complete all as specified and directed.[Note : Total Qty : 181.00 (Part-II) + 16.00 (Part-IV) = 197.00] |
| 161 | S&F in repairs MCB SPN 32 Amps, 'C' series 10kA, 240 Volts and to be housed in DBs complete including necessary connection complete all as specified and directed.[Note :- (a) Proper and suitable size cable lugs to be fixed with MCB are included in unit rate of each MCB of any rating (b) Total Qty : 12.00 (Part-II) + 4.00 (Part-IV) = 16.00] |
| 162 | S&F in repairs MCCB 4 pole, 3 phase, 415 volt of capacity 63 Amp, 16 KA with fixed magnetic and thermal adjustment complete with proper copper thimbles, copper reducer etc complete all as specified and directed. |
| 163 | M&L earthing complete with galvanised mild steel earth plate electrode 600x600x6.0mm thick, buried directly in ground to a depth not less than 2.25 metres deep below ground level with top edge of earth plate not less than 1.5 metre below normal ground level surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15 cm all around the plate, using GI wire 4 mm dia as earth wire electrode bolted or rivetted to earth plate at one end and connected to equipments at another end, GI earth wire encased in and including 40 mm dia GI 'light grade' pipe from upper end of earth plate upto equipments,20 dia bore GI pipe 'light grade' as water pipe from earth chamber to upper edge of earth plate, Test point , GI funnel with wire mesh fixed on water pipe and Plain Cement Concrete 1:2:4 type B-1 (using 20mm graded stone aggregate) as in pit chamber and Reinforced Cement Concrete pit cover 50mm thick precast Reinforced Cement Concrete 1:2:4 type B-1, duly reinforced with MS round bars 6mm dia @ 100 c/c both ways with 10mm dia MS round bar as in lifting handles, excavation, earth work including laying the GI pipe concealed in floor/wall all as described in electric plate No-3 of SSR Part I complete all as specified and directed and testing on completion.[Note :- If the desired earth resistance is not found, earthing shall be redone by the contractor at no extra cost to the department.] |
| 164 | SCH A Part -III (EXTERNAL WATER SUPPLY) |
| 165 | Returning, filling in, including spreading, leveling, watering & well ramming in layers n. exc 25 cm thick complete all as specified and directed.[Note : Total Qty : 41.00 (Part-III) + 18.00 (Part-IV) + 271 (Part-IV) = 330.00] |
| 166 | Removal of excavated soil to a distance not exc 50m and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified and directed.[Note : Total Qty : 28.00 (Part-III) + 1.00 (Part-IV) + 223 (Part-V) = 252.00] |
| 167 | Relaying/ re-fixing old 80mm bore GI tubing or in floor/ pillar/ wall in new or old position including taking up or down old serviceable pipes complete all as specified and directed. |
| 168 | Relaying/ re-fixing old 50mm bore GI tubing or in floor/ pillar/ wall in new or old position including taking up or down old serviceable pipes complete all as specified and directed. |
| 169 | Relaying/ re-fixing old 40mm bore GI tubing or in floor/ pillar/ wall in new or old position including taking up or down old serviceable pipes complete all as specified and directed. |
| 170 | Relaying/ re-fixing old 25mm bore GI tubing or in floor/ pillar/ wall in new or old position including taking up or down old serviceable pipes complete all as specified and directed. |
| 171 | M&L 80mm bore GI tubing, medium grade as in Trenches/ Floor/Pillar and connection in old or news position including fitting like socket/ Union/ Tee/ Reducer Nipple etc. including taking up or down old unserviceable pipes required complete all as specified and directed. |
| 172 | M&L 50mm bore GI tubing medium grade in Trenches/ Floor/Pillar and connection in old or news position including fitting like socket/ Union/ Tee/ Reducer Nipple etc. including taking up or down old unserviceable pipes required complete all as specified and directed. |
| 173 | M&L 40mm bore GI tubing medium grade in Trenches/ Floor/Pillar and connection in old or news position including fitting like socket/ Union/ Tee/ Reducer Nipple etc. including taking up or down old unserviceable pipes required complete all as specified and directed. |
| 174 | M&L 25mm bore GI tubing medium grade in Trenches/ Floor/Pillar and connection in old or news position including fitting like socket/ Union/ Tee/ Reducer Nipple etc. including taking up or down old unserviceable pipes required complete all as specified and directed. |
| 175 | S&F 100mm bore CI sluice valve PN - 1.6 IS : 14846-2000 with Spindle Iron (Heavy duty) Wheel head and both ends flanged and MS nut bolts and washers and pair of rubber/ fiber gasket and fixed in position including taking down old of existing unserviceable CI sluice valve compete all as specified and directed. |
| 176 | S&F 150mm bore CI sluice valve PN - 1.6 IS : 14846-2000 with Spindle Iron (Heavy duty) Wheel head and both ends flanged and MS nut bolts and washers and pair of rubber/ fiber gasket and fixed in position including taking down of existing unserviceable CI sluice valve compete all as specified and directed. |
| 177 | Refixing of Sluice valve 150mm bore after taking out, refacing of valve spindle , regrinding, including taking part and reassembling as per existing and complete scaling and proper functioning at site including replacement of nuts, bolts, washers and gasket as required at site including taking down of existing CI sluice valve complete all as specified and directed. |
| 178 | Refixing of Sluice valve 100mm bore after taking out, refacing of valve spindle , regrinding, including taking part and reassembling as per existing and complete scaling and proper functioning at site including replacemwent of nuts, bolts, washers and gasket as required at site including taking down of existing CI sluice valve complete all as specified and directed. |
| 179 | M&L 50mm bore gate valve gun metal class-II (Grade-II) PN-16 (IS : 778) screwed down high pressure with clutch handle screwed both ends for Iron pipe including taking out of old unserviceable gate valve complete all as specified and directed. |
| 180 | M&L 40mm bore gate valve gun metal class-II (Grade-II) PN-16 (IS : 778) screwed down high pressure with clutch handle screwed both ends for Iron pipe including taking out of old unserviceable gate valve complete all as specified and directed. |
| 181 | M&L 25mm bore gate valve gun metal class-II (Grade-II) PN-16 (IS : 778) screwed down high pressure with clutch handle screwed both ends for Iron pipe including taking out of old unserviceable gate valve complete all as specified and directed. |
| 182 | M&L 20mm bore gate valve gun metal class-II (Grade-II) PN-16 (IS : 778) screwed down high pressure with clutch handle screwed both ends for Iron pipe including taking out of old unserviceable gate valve complete all as specified and directed. |
| 183 | S&F of rotational moulded polyethylene water storage tank of capacity 1000 Ltrs (Cylindrical, vertical with closed threaded top lid 100% virgin food-grade plastic, four layered, UV stabilized, highly resistant to algae & bacterial growth, complete including provision of all inlet, outlet, overflow, and drain pipe fitting including dismanty the old unserviceable complete all as specified and directed. |
| 184 | S&F of rotational moulded polyethylene water storage tank of capacity 2000 Ltrs (Cylindrical , vertical with closed threaded, top lid 100% virgin food-grade plastic, four layered, UV stabilized, highly resistant to algae & bacterial growth, complete including provision of all inlet, outlet, overflow, and drain pipe fitting complete all as specified and directed. |
| 185 | S&F of high pressure PTMT ball float valve suitable for size of 25mm dia with epoxy coated aluminium rod & HD plastic ball screwed for iron pipe including GI fitting as required after taking out old unserviceable item complete all as specified and directed. |
| 186 | S&F of high pressure PTMT ball float valve suitable for size of 20mm dia with epoxy coated aluminium rod & HD plastic ball screwed for iron pipe including GI fitting as required after taking out old unserviceable item complete all as specified and directed. |
| 187 | M&L 0.90mx0.90mx0.9m brick massonary valve pit with brick in fly ash, old size brick in Cement Mortar (1:6) with 100mm thick Plain Cement Concrete work 1:4:8 type D2 using 40mm graded stone aggregate as in foundation, internal and external plaster at bottom of the pit along with valve pit cover made out MS angle iron 50mm x 50mm x 6mm frame work, MS plate cover made out of 40x6mm thick with locking arrangement fixed over the valve pit with Plain Cement Concrete 1:2:4 50mm the coping on brickwork, external surface shall be white work including a coat of synthetic enamel paint over a coat of red oxide primer complete including necessary frame work welding, drilling excavation, earthing, reling, filling etc complete all as specified and directed. |
| 188 | SCH A Part -IV (AIR-CONDITIONING & REFRIGERATION) |
| 189 | S&F 1.5 TR capacity split units indoor/ outdoor complete with cordless remote control unit and with in built air ioniser and plasma filter for better indoor air quality with minimum 3 star rating (BEE 2026 Norm) and ISEER of minimum 3.7 and annual energy conservation of approximately not greater than 1100 (Per 16 hr), cooling capacity rated at 5000 units-5500W, min 5 in 1 convertible cooling, inverter technology with rotory invertor compressor, refrigerant R-32, smart connectivity, 100% copper condenser coils, standard warranty typically includes 2 years compressor, 5 years of the PCB & 10 years on the compressor, outdoor unit & casing for 5 years, availability of BIS/ ISI mark certification (IS:1391 (Part-2), complete all as specified and directed. |
| 190 | S&F Voltage Stabilizer for automatic operation single phase naturally air cooled indoor type & desgined for input variation between 130V to 280V with output voltage stabilizer at 220V to 240V with accuracy of + and of capacity of 4 KVA, complete all as specified and directed. |
| 191 | S&F sub main wiring two single core, 4 sqmm nominal cross sectional area multistranded copper conductor FRLSH cable, PVC insulated unsheathed 1100 Volts grade drawing in and including suitable size PVC conduit (ISI marked)(medium grade), concealed, including one run 4 sqmm nominal cross sectional area multistranded copper conductor FRLSH cable, PVC insulated unsheathed 1100 Volts grade earth wire, complete all as specified and directed.[Note : Three run of 4.00 sqmm cable alongwith PVC conduit shall be measured and paid as one unit] |
| 192 | S&F in repairs epoxy powder coated sheet metal enclosure for DBs, double door (when MCBs to be used), Single pole and neutral 240V, 12 ways with mounting fitted with bus bar, DIN channel, neutral link and incoming contact complete all as specified and directed. |
| 193 | S&F testing complete XLPE armoured cable 16 sqmm 4 core, 1100 volts grade, heavy duty cable, ISI marked passing through pipe, with PVC insulated aluminium conductor served with and inner sheathing of PVC tape armoured with galvanized steel wire or tape and overall PVC sheathed, complete all as specified and directed.[Note : Total Qty : 85.00 (Part-IV) + 65.00 (Part-V) = 150.00] |
| 194 | Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m depth and getting out in hard/ dense soil, complete all as specified and directed. |
| 195 | Supply and lay for dry river sand filling for cable protection with at layer of 8cm deep before laying and 15cm covering above the top edge of cable after laying, complete all as specified and directed.[Note : (a) Total Qty : 7.00 (Part-IV) + 161.00 (Part-V) = 168.00(b) Punned thickness shall be measured] |
| 196 | M&L sub class B bricks locally available of size 25 x 12.5 x 7.5 cm laid dry width wise across the line of cable in trenches for protection of UG cable, complete all as specified and directed.[Note : Total Qty : 0.80 (Part-IV) + 15.94 (Part-V) = 16.74] |
| 197 | S&F in repairs GI pipe, Light grade, 40mm bore of size for road cross/ cutting on wall floor drain etc, complete all as specified and directed. |
| 198 | SCH A Part -V (EXTERNAL ELECTRIFICATION) |
| 199 | Dismantling steel poles/struts, any size, complete all as specified and directed. |
| 200 | Dismantling Insulators like Pin type, disc type for HT from existing Electric Poles of any description and any size, complete all as specified and directed. |
| 201 | Dismantling of ACSR or AAC conductors, complete all as specified and directed. |
| 202 | Dismantling of cross arms of MS channel or angle iron sections etc complete all as specified and directed. |
| 203 | Taking down/out unserviceable or serviceable UG Cables of any Cross Sectional Area and Connections including Bricks, GI Pipes, etc. of any descriptions, laid in Trenches and/or fixing with Walls/Poles including Segregating of Serviceable Materials viz Bricks, Cables, GI Pipes, etc. and keep in Safe custody for re-use, complete all as specified and directed.[NOTE : Earth Work shall be Measured and Paid for separately under relevant Items]. |
| 204 | M&L testing cable in trenches or passing through pipe, XLPE insulated, heavy duty, galvanised steel strip or wire armoured electric LT cable with stranded aluminium conductor for 1100 volts grade cross sectional area 10 sqmm 4 core, complete all as specified and directed. |
| 205 | M&L testing cable in trenches or passing through pipe, XLPE insulated, heavy duty, galvanised steel strip or wire armoured electric LT cable with stranded aluminium conductor for 1100 volts grade cross sectional area 25 Sqmm 3.5 Core complete all as specified and directed. |
| 206 | M&L cable in trenches or passing through pipe, XLPE insulated, heavy duty, galvanised steel strip or wire armoured electric LT cable with stranded aluminium conductor for 1100 volts grade cross sectional area 70 Sqmm 3.5 Core complete all as specified and directed. |
| 207 | M&L in testing cable in trenches or passing through pipe, XLPE insulated, heavy duty, galvanised steel strip or wire armoured electric LT cable with stranded aluminium conductor for 1100 volts grade cross sectional area 95 Sqmm 3.5 Core complete all as specified and directed. |
| 208 | M&L testing cable in trenches or passing through pipe, XLPE insulated, heavy duty, galvanised steel strip or wire armoured electric LT cable with stranded aluminium conductor for 1100 volts grade cross sectional area 150 Sqmm 3.5 Core complete all as specified and directed. |
| 209 | M&L testing cable in trenches or passing through pipe, XLPE insulated, heavy duty, galvanised steel strip or wire armoured electric LT cable with stranded aluminium conductor for 1100 volts grade cross sectional area 185 Sqmm 3.5 Core complete all as specified and directed. |
| 210 | Re-Laying/Fixing or Passing through Pipe, XLPE insulated, Armoured, Electric Power UG Cable (Heavy Duty) with Aluminium Conductor, 1100 Volt Grade, Nominal Cross-Sectional Area 10 Sqmm 4 Core including Brass Compression Cable Gland, Terminal Lug, etc. complete all as specified and directed |
| 211 | Re-Laying/Fixing or Passing through Pipe, XLPE insulated, Armoured, Electric Power UG Cable (Heavy Duty) with Aluminium Conductor, 1100 Volt Grade, Nominal Cross-Sectional Area 16 Sqmm 4 Core including Brass Compression Cable Gland, Terminal Lug, etc. complete all as specified and directed. |
| 212 | Re-Laying/Fixing or Passing through Pipe, XLPE insulated, Armoured, Electric Power UG Cable (Heavy Duty) with Aluminium Conductor, 1100 Volt Grade, Nominal Cross-Sectional Area 25 Sqmm 3½ Core including Brass Compression Cable Gland, Terminal Lug, etc. complete all as specified and directed. |
| 213 | Re-Laying/Fixing or Passing through Pipe, XLPE insulated, Armoured, Electric Power UG Cable (Heavy Duty) with Aluminium Conductor, 1100 Volt Grade, Nominal Cross-Sectional Area 50 Sqmm 3½ Core including Brass Compression Cable Gland, Terminal Lug, etc. complete all as specified and directed. |
| 214 | Re-Laying/Fixing or Passing through Pipe, XLPE insulated, Armoured, Electric Power UG Cable (Heavy Duty) with Aluminium Conductor, 1100 Volt Grade, Nominal Cross-Sectional Area 70 Sqmm 3½ Core including Brass Compression Cable Gland, Terminal Lug, etc. complete all as specified and directed. |
| 215 | Taking down/out unserviceable GI / HDPE Pipes of any descriptions, laid in trenches and/or fixing with Walls/Poles complete all as specified and directed. |
| 216 | S & F 50 mm High density polyethylene pipe (HDPE) of pressure rating 6 kgf/cm2 fixed complete to walls, ceilings or in floors etc. complete all as specified and directed . |
| 217 | S&F Galvanised Iron Pipe 80mm Bore (dia) ‘Light Grade’ for protection of UG Cable, laid in Floors/ Road Crossing, fixing to Pole with Mild Steel Clamps, Nuts, Bolts, etc., complete all as specified and directed. |
| 218 | S&F Galvanised Iron Pipe 50mm Bore (dia) ‘Light Grade’ for protection of UG Cable, laid in Floors/ Road Crossing, fixing to Pole with Mild Steel Clamps, Nuts, Bolts, etc., complete all as specified and directed. |
| 219 | S&F Galvanised Iron Pipe 100mm Bore (dia) ‘Light Grade’ for protection of UG Cable, laid in Floors/ Road Crossing, fixing to Pole with Mild Steel Clamps, Nuts, Bolts, etc., complete all as specified and directed. |
| 220 | Labour only for Horizontal Boring by HDD machine for Passing Protection Pipe up to 80mm Bore (dia), under Road /Foot Path, not exc. 10.00 mtr in a Single Length, complete all as specified and directed.[Note : Pipe to be measured separately.] |
| 221 | M&L Straight Through Cable Joint Kit including Jointing Materials for making Joints of UG Electric Cable 1100 Volt Grade Heavy Duty with PVC/XLPE insulated Aluminium Stranded Conductor, Nominal Cross-Sectional area 10 Sqmm to 16 Sqmm, 4 Core and Testing complete all as specified and directed. |
| 222 | M&L Straight Through Cable Joint Kit including Jointing Materials for making Joints of UG Electric Cable 1100 Volt Grade Heavy Duty with PVC/XLPE insulated Aluminium Stranded Conductor, Nominal Cross-Sectional area 25 Sqmm to 50 Sqmm, 3½ Core and Testing complete all as specified and directed. |
| 223 | All as per item No. 5.024 above but of Nominal Cross-Sectional area exc. 70-120 Sqmm, 3½ Core and Testing complete all as specified and directed. |
| 224 | S&F HDPE DWC (Double Walled Corrugated) of Diameter 25 mm including disconnection and connection of cable near panel/OH for pipe fixing including joints complete all as specified and directed. |
| 225 | S&F HDPE DWC (Double Walled Corrugated) of Diameter 40 mm including disconnection and connection of cable near panel/OH for pipe fixing including joints complete all as specified and directed. |
| 226 | S & F HDPE DWC (Double Walled Corrugated) of Diameter 50 mm including disconnection and connection of cable near panel/OH for pipe fixing including joints complete all as specified and directed. |
| 227 | S & F HDPE DWC (Double Walled Corrugated) of Diameter 100 mm including disconnection and connection of cable near panel/OH for pipe fixing including joints complete all as specified and directed. |
| 228 | M&L earthing complete with MS galvanized plate of size 60cmx60cmx6mm as earth electrode , buried directly in ground (earth pit not less than 2.25 mtrs deep below ground level) with top edge of the plate not less than 1.5 mtrs below normal ground level, connected to galvanised iron strip 32×6mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron/welding or steel all as shown in electrical plate No 3 in SSR Part I of 2009 connected to earthing test point all as specified complete with excavation & earth work, PCC pit with 50mm thick RCC cover/CI /MS cover having suitable handle (10mm MS Rod) 20mm dia GI medium grade watering pipe with GI funnel with wire mesh 40mm bore GI pipe medium grade ISI marked) for protection of earth lead conductor and testing on completion complete all as specified and directed. |
| 229 | Supply, commissioning and testing Outdoor type LT Distribution Panel, Double door type, weather proof, CPRI approved, Seven tank treatment powder coated factory made LT Panel board, totally enclosed, dust and vermin proof openable from front & back side, canopy headed, Cable alley at both sides, connected with suitable size MS angle iron frame, for main distribution Panel, fabricated with CRCA sheet 3.15mm thick sheet including IP - 54 protection, installed on concrete base made of PCC (1:3:6) type C1 using 20mm graded aggregate ,including self locking arrangement including taking down/ dismantling old unserviceable LT panels complete all as specified and directed.BUS BAR CHAMBER(a) Sheet steel bus bar chamber having front hinged covers with a set of electrolytic grade high conductivity TP&N solid aluminium bus bars, rated 400 Amps supported at required intervals sleeved with heat shrinkable PVC sleevings. The bars shall be colour coded at required intervals for identification - SET OF 4 : 1 No.INCOMER(a) MCCB 250 Amps, 415 volt, 36 KA Breaking capacity 4 pole adjustable thermal & magnetic setting duly connected to bus bar -01 Nos.(b) Manual Change over switch 250 Amp, 415 V: 01 NosOUTGOING FEEDERS(a) MCCB 100 Amps, 415 volt, 16 KA Breaking capacity 4 pole duly connected to bus bar : 03 Nos. |
| 230 | items No. 5.031 (Contd….)(b) MCCB 25 Amps, 415 volt, 16 KA Breaking capacity 4 pole duly connected to bus bar -02 Nos.(c) MCCB 16 Amps, 415 volt, 16 KA Breaking capacity 4 pole duly connected to bus bar -01 Nos.INDICATING DEVICES(a) LED Indicating lamps for Main Supply indicating R', Y' B' - Set of 3.(b) Digital Voltmeter (96mmx96mm) 0-500 Volt with selector switch of 10Amps -1No. (c) Current Transformer having Ratio 200/5 - SET OF 3.(d) Digital Ammeter 0 to 500 Amps with selector switch - 1 No.(e) Control MCB 2.0 Amps SP - 3 No. |
| 231 | Supply, commissioning and testing Outdoor type LT Distribution Panel, Double door type, weather proof, CPRI approved, Seven tank treatment powder coated factory made LT Panel board, totally enclosed, dust and vermin proof openable from front & back side, canopy headed, Cable alley at both sides, connected with suitable size MS angle iron frame, for main distribution Panel, fabricated with CRCA sheet 3.15mm thick sheet including IP - 54 protection, installed on concrete base made of PCC (1:3:6) type C1 using 20mm graded aggregate ,including self locking arrangement including taking down/ dismantling old unserviceable LT panels complete all as specified and directed.BUS BAR CHAMBER(a) Sheet steel bus bar chamber having front hinged covers with a set of electrolytic grade high conductivity TP&N solid aluminium bus bars, rated 400 Amps supported at required intervals sleeved with heat shrinkable PVC sleevings. The bars shall be colour coded at required intervals for identification - SET OF 4, 1 No.INCOMER(a) MCCB 200 Amps, 415 volt, 36 KA Breaking capacity 4 pole adjustable thermal & magnetic setting duly connected to bus bar -01 Nos.(b) Manual Change over switch 200 Amp,415 V: 01 NosOUTGOING FEEDERS(a) MCCB 63 Amps, 415 volt, 16 KA Breaking capacity 4 pole duly connected to bus bar-02 Nos. |
| 232 | items No. 5.033 (Contd….)(b) MCCB 40 Amps, 415 volt, 16 KA Breaking capacity 4 pole duly connected to bus bar-04 Nos.(c) Astronomical Timer Switch 1 outlet 16 A-250V,vertical dial N/O contact,power supply 230V,50/60Hz,three position override switch \\"ON-AUTO-OFF\\" on front panel-01 Nos,(d) 25A ,2 NO Contactor 3 phase, with 230V coil-01 Nos, 32 A MCB TPN-01Nos with suitable relay and other accessoris and wiring if any required with min 1 Sqmm copper conductor cable and instrument wiring with 1.5 Sqmm fine, terminal blocks.INDICATING DEVICES(a) LED Indicating lamps for Main Supply indicating R', Y' B' - Set of 3.(b) Digital Voltmeter (96mmx96mm) 0-500 Volt with selector switch of 10Amps -1No. (c) Current Transformer having Ratio 250/5 - SET OF 3.(d) Digital Ammeter 0 to 500 Amps with selector switch - 1 No.(e) Control MCB 2.0 Amps SP - 3 No. |
| 233 | Supply, commissioning and testing Outdoor type LT Distribution Panel, Double door type, weather proof, CPRI approved, Seven tank treatment powder coated factory made LT Panel board, totally enclosed, dust and vermin proof openable from front & back side, canopy headed, Cable alley at both sides, connected with suitable size MS angle iron frame, for main distribution Panel, fabricated with CRCA sheet 3.15mm thick sheet including IP - 54 protection, installed on concrete base made of PCC (1:3:6) type C1 using 20mm graded aggregate ,including self locking arrangement including taking down/ dismantling old unserviceable LT panels complete all as specified and directed.BUS BAR CHAMBER(a) Sheet steel bus bar chamber having front hinged covers with a set of electrolytic grade high conductivity TP&N solid aluminium bus bars, rated 250 Amps supported at required intervals sleeved with heat shrinkable PVC sleevings. The bars shall be colour coded at required intervals for identification - SET OF 4 : 1 No.INCOMER(a) MCCB 125 Amps, 415 volt, 16 KA Breaking capacity 4 pole adjustable thermal and magnetic setting duly connected to bus bar-01 Nos.OUTGOING FEEDERS(a) MCB TPN 25 Amps C series, 10 KA - 03 Nos duly connected to bus bar(b) MCB TPN 16 Amps C series, 10 KA - 03 Nos duly connected to bus bar |
| 234 | items No. 5.035 (Contd….)INDICATING DEVICES(a) LED Indicating lamps for Main Supply indicating R', Y' B' - Set of 3.(b) Digital Voltmeter (96mmx96mm) 0-500 Volt with selector switch of 10Amps -1No. (c) Current Transformer having Ratio 125/5 - SET OF 3.(d) Digital Ammeter 0 to 500 Amps with selector switch - 1 No.(e) Control MCB 2.0 Amps SP - 3 No. |
| 235 | M& L steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-31 (9.00 metres long) complete all as specified & directed.[Note : Original manufacturer's test certificate to be submitted to Engr-in-Charge before claiming payment] |
| 236 | S&F LED street light fitting 100 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics,efficacy 110/120 LPW, complete with IP 65/66 protection complete all as specified and directed. |
| 237 | S&F Cable Junction Box 155X210X92 mm in size, made out of thermoplastic, having IP 66 protection for outdoor installation fixed with 4 way bakelite cable terminals including 03 Nos polymide gland with check nut (M-32 -02 No & M-25 -01 No) fixed on poles with Aluminium clamps of size 25x3mm, nuts, bolts, washers etc. including taking out of old unserviceable cable junction box complete all as specified and directed.[Make : Cat No. DK-1616G of HENSEL or similar in other branded make as specified in list of makes in PS herein after] |
| 238 | Supply and passing through steel tubler pole/service connection, 1100 volts grade multicore,FR, round insulated copper conductor and sheathed flexible cable,multistranded, three core of nominal cross sectonal area 1.5 Sq mm,for connection of security light from junction box through pole /conduit with all terminals complete all as specified and directed. |
| 239 | S&F single arm bracket made of 40mm dia 1.0mtr long for security light ,with mounting MS clamp of flat iron size 25X5 mm of suitable length 02 pairs including nut bolts etc of suitable size and painting to MS clamp with two coats of aluminium paints over a coat of red oxide metal primer complete all as specified and directed. |
| 240 | M&L Plain Cement Concrete (1:2:4) type B1 (using 20 mm graded stone aggregate) as in coping for pole including form work and finishing the surfaces even and smooth,dismantling etc complete all as specified and directed. |
| 241 | M&L Plain Cement Concrete 1:3:6 type C2 (using 40 mm graded stone aggregate) as in foundation for pole etc complete all as specified and directed. |
| 242 | S&F street light panel CRCA sheet steel duly phosphatized and powder coated with 7 tank process,wall/pole mounted/floor mounted,degree of protection IP 54,pre-wired,liberal terminal space,louvers provided on both sides for proper heat heat dissipation,manufactured by an ISO 9001 certified company,door locking by panel lock and provided for pad locking available,with auto/manual selection switch,astronomical programmable time switch( Operating voltage 220-240 Volt AC),three phase,MCB TPN 63 Amp(coil voltage 240 Volt AC) ,Power Contactor 65 Amp,TP,Astronomical timer,terminal blocks,maximun load 12KW, complete all as specified and directed.[Make Havells Cat No.IHXTS0912A or similar make in brand or as mentioned in list of makes in PS here in after] |
| 243 | S&F LED Flood light fitting 200 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics,efficacy 110/100 LPW, complete with IP 66 protection complete all as specified and directed. |
| 244 | S&F in replacement post top lantern LED type 20 watt 230 watt volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp complete all as specified and directed. |
| 245 | S&F LED Solar street light fitting 36 Watt high lumen greater than 50000hrs & CRI nominal 0.70 pressure die cast aluminium IP-66 enclosures including galvanized steel pole in built,lithium ion battery provide energy & backup upto 3 days when there is little or no sun, polycrystalline silicon solar panel, charge controller with dusk down sensor dimming facility, standalone autonomy 3 days complete all as specified and directed.(Excavation & earth work shall be measured separately) Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail