| 1 | Supplying, laying and testing cable XLPE Insulated screened PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor, 1100 volts grade of size 4 core, 10 sqmm including taking down of old unserviceable cable complete all as specified and as directed. |
| 2 | Supplying, laying and testing cable XLPE Insulated screened PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor, 1100 volts grade of size 4 core, 16 sqmm including taking down of old unserviceable cable complete all as specified and as directed. |
| 3 | Supplying, laying and testing cable XLPE Insulated screened PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor, 1100 volts grade of size 3.5 core, 70 sqmm including taking down of old unserviceable cable complete all as specified and as directed. |
| 4 | Supplying, laying and testing cable XLPE Insulated screened PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor, 1100 volts grade of size 3.5 core, 120 sqmm including taking down of old unserviceable cable complete all as specified and as directed. |
| 5 | M&L for cutting the tar macadam road / hard standings for laying cable and excavating not exe. 60cm wide and n. exc 75cm depth and getting out all as directed including filing back, consolidating etc complete and finishing it with 200mm thick PCC 1:4:8, type D-2 (using 40mm graded crushed stone aggregates) complete all as specified and directed |
| 6 | S&F galvanised iron pipes 40mm dia,. light grade, with all fitting and fixed complete to poles/route/drains etc and ceillings or laid in floors complete all as specified and directed |
| 7 | S&F Double wall corrugated HDPE Pipe IS-16205, outer dia 75mm for cable protection in wall/under gorund laying of UG cables including SNAP-FIT Coupler and all fittings as required at site complete all as specified and as directed |
| 8 | S&F Double wall corrugated HDPE Pipe IS-16205, outer dia 40mm for cable protection in wall/under gorund laying of UG cables including SNAP-FIT Coupler and all fittings as required at site complete all as specified and as directed |
| 9 | M&L for earthing and testing complete with galvanized iron earth plate electrode 60cm x 60 cm x 6mm thick buried directly in ground vertically to a depth not less than 2.25 M below normal ground level with top edge of earth plate at a depth not less than 1.5 M below normal ground level connected to and including GI strip 32x6mm as earth lead by means of bolts and nuts, check nuts and washers etc made of GI & connected to equipment and earthing test point , earth dolly all as shown in elect plate No 3 of SSR Pt-I including all necessary earth work, excavation PCC chamber cover with handle (PCC 1:2:4) and 20mm dia GI watering pipe and 40 mm dia light grade GI for protection of earth strip, wire mesh, funnel, charcoal dust & common salt, etc., complete all as specified and directed |
| 10 | Supplying, laying, and fixing 3-core 10 sqmm multi-stranded XLPE copper conductor cables, 1100V grade, conforming to IS:694, drawn through heavy-duty rigid PVC conduit of size 63 mm (conforming to IS:9537 Part III) with necessary accessories such as bends, elbows, junction boxes, and suitable saddles fixed at specified intervals, including cutting chases in walls/floors where required, making good the surface, and testing the complete installation to the satisfaction of the Engineer-in-Charge. The rate shall include all materials, labour, tools, and plants required for the proper execution of work complete all as specified and directed |
| 11 | S&F 3 core flat multistranded copper cable 10 sqmm for submersible pump set/Centrifugal mono bloc pump sets including necessary connection and testing complete all as specified and as directed. |
| 12 | S&F 3 core flat multistranded copper cable 6 sqmm for submersible pump set/Centrifugal mono bloc pump sets including necessary connection and testing complete all as specified and as directed. |
| 13 | S&F in repairs MCCB 3 Pole .415 V. fixed type, 25 to 100 Amps with breaking capacity 16 KA complete all as specified and directed |
| 14 | S&F in repairs MCCB 4 Pole .415 V. fixed type, 63 Amps with breaking capacity 16 KA complete all as specified and directed |
| 15 | Supply, installation, testing and commissioning of MU-G20 Fully Automatic Star-Delta (FASD) Starter suitable for starting 3-phase induction motors, complete with main contactor, star contactor, delta contactor, thermal overload relay, timer, control MCB, indicating lamps, and push buttons, housed in powder-coated CRCA sheet steel enclosure, suitable for 415V ±10%, 50Hz AC supply, conforming to relevant IS/IEC standards complete all as specified and directed . |
| 16 | Supply, installation, testing and commissioning of MU-G30 Fully Automatic Star-Delta (FASD) Starter suitable for starting 3-phase induction motors, complete with main contactor, star contactor, delta contactor, thermal overload relay, timer, control MCB, indicating lamps, and push buttons, housed in powder-coated CRCA sheet steel enclosure, suitable for 415V ±10%, 50Hz AC supply, conforming to relevant IS/IEC standards complete all as specified and directed |
| 17 | Excavation in trenches not exceeding 1.5m depth and not exc 1.5m wide and getting out in hard / dense soil for laying cable/erecting poles complete all as specified and directed. |
| 18 | Returning and filling in soil including spreading levelling watering and well ramming in layers not exceeding 25cm thick complete all as specified and directed. |
| 19 | Removing excavated soil to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed. |
| 20 | Supply, installation, testing and commissioning of glycerine-filled dial type pressure gauge suitable for water service, range 0–10 kg/cm² (0–10 bar), minimum 100 mm dial size, SS case, brass wetted parts with ½” BSP(M) bottom entry, complete with siphon (pigtail), isolating ball valve, nipples, unions and mounting bracket, including cutting/drilling hole in the existing delivery pipe, welding/fixing suitable GI socket/tee, connecting suitable GI pipe up to the pressure gauge and making all leak-proof connections complete all as specified and directed. |
| 21 | Supply, installation, testing and commissioning of lever operated 65 mm dia butterfly valve (wafer type), suitable for water supply pipeline, having CI/DI body, stainless steel disc and shaft, EPDM/NBR seat, complete with lever arrangement, nuts, bolts, rubber gaskets, fitting between existing flanges, including dismantling of old fittings, alignment, tightening, testing and commissioning complete all as specified and as directed. |
| 22 | Supply, installation, testing and commissioning of lever operated 80 mm dia butterfly valve (wafer type), suitable for water supply pipeline, having CI/DI body, stainless steel disc and shaft, EPDM/NBR seat, complete with lever arrangement, nuts, bolts, rubber gaskets, fitting between existing flanges, including dismantling of old fittings, alignment, tightening, testing and commissioning complete all as specified and as directed. |
| 23 | Supply, installation, testing and commissioning of lever operated 100 mm dia butterfly valve (wafer type), suitable for water supply pipeline, having CI/DI body, stainless steel disc and shaft, EPDM/NBR seat, complete with lever arrangement, nuts, bolts, rubber gaskets, fitting between existing flanges, including dismantling of old fittings, alignment, tightening, testing and commissioning complete all as specified and as directed. |
| 24 | Supply, laying and fixing UPVC pipes 65mm bore including all fittings such as bends, tees, elbows, reducers, sockets, unions etc., jointing with approved solvent cement, cutting, threading wherever required, testing and commissioning complete all as specified and as directed. |
| 25 | M&L for providing precast cement concrete type B1, 1:2:4 (using 20mm graded crushed stone aggregates) as in landings, cover slabs (for man holes etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces, string courses, copings. kneelers, apex stones, pier caps, columns, posts, boundary pillars, bed plates, pintle blocks, ancho-rage blocks, bonders (for stone wallin). corbels, brackets, etc. (of any section indicated), with plain fair faces, including cham fers, weatherings, throat- ing etc. and setting in mortar complete with joints to match complete all as specified and as directed. |
| 26 | M&L for mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and bindingwith and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified asnd as directed. |
| 27 | S&F in repairs framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings including two coats of synthetic enamel paint and one coat of red oxide primer and also fastening and fixing cconfirming to Fe 410-W (Gde E- 250) quality A complete all as specified and as directed. |
| 28 | Taking up Cast iron water main of size 150mm dia including all fittings for spigot and socket ends and lead joints including burning out lead joint and recovering lead complete all as specified as directed. |
| 29 | Taking up or down steel tubing along with fittings such as tee, bends etc fixed to walls and ceilings or laid in floos/trenches and connections incl removal from site of 40mm dia pipe complete all as specified as directed. |
| 30 | Taking up or down steel tubing along with fittings such as tee, bends etc fixed to walls and ceilings or laid in flours/trenches and connections incl removal from site of 25mm dia pipe complete all as specified as directed. |
| 31 | Supplying, laying and testing 150mm nominal dia ductile iron pipe , spigot and socket including rubber joints class K-7 complete all as specified and as directed. Note :- Specials and fittings will be measured and paid separately. |
| 32 | S&F GI tubing medium grade 40mm bore pipes with all new connections and fittings such as tees, bends, elbows, short pieces, connector back nuts, diminishing pieces, caps, plugs, unions, etc., laid in trenches complete all as specified and as directed |
| 33 | S&F GI tubing medium grade 25mm bore pipes with all new connections and fittings such as tees, bends, elbows, short pieces, connector back nuts, diminishing pieces, caps, plugs unions etc fixed complete to walls and ceilings or laid in floors complete all as specified and as directed |
| 34 | S&F Ductile iron fittings such as bends (any type, radius and angle) tapers any type (straight, bend, increasing, decreasing or double socket etc) tee pieces single branch ‘Y’ junction, double branch, cross (all socket or socket and spigot or flanged and socket etc) color, caps and plugs suitable for DI pipe upto 150 mm dia complete all as specified and as directed. |
| 35 | M&L for modification of existing sluice valve operation arrangement by extending valve spindle/wheel head to required height using suitable size Galvanised Iron (GI) pipe, including fabrication, coupling, welding/threading, fixing and alignment for operation of valve from top level of valve chamber, complete all as specified and as directed. The work also includes cutting, reshaping and making suitable opening in existing valve chamber cover/door for smooth operation, finishing edges, applying anti-corrosive paint to disturbed portions and making good complete all as specified and directed. |
| 36 | M&L for construction of brick massonry valve pit chamber of inner dimension 100cmx100cmx100cm suitable for sluice valves upto 200mm size, including PCC 1:4:8 type D-2 for foundation, brick work in CM(1:6), rendering 15mm thick in CM(1:4), coping in PCC 1:2:4, type B-1, incl necessary earth work, MS sheet cover of thickness 3.15mm on 50x50x6.0 mm angle iron framework duly painted with two coats of synthetic enamelled paint over a coat of red oxide primer with making provision of locking arrangement including demolition of old valve pit complete all as specified and as directed. |
| 37 | S&F in repairs cast iron sluice valve PN 1.6 with both ends flanged confirming to the IS 14846 with brass spindle and iron wheel head flanged inclding new rubber gaskets, bolts and nuts etc including dismantling of existing unserviceable one for the 150mm dia pipe complete all as specified and directed |
| 38 | S&F in repairs cast iron sluice valve PN 1.6 with both ends flanged confirming to the IS 14846 with brass spindle and iron wheel head flanged inclding new rubber gaskets, bolts and nuts etc including dismantling of existing unserviceable one for the 100mm dia pipe complete all as specified and directed |
| 39 | S&F in repairs cast iron sluice valve PN 1.6 with both ends flanged confirming to the IS 14846 with brass spindle and iron wheel head flanged inclding new rubber gaskets, bolts and nuts etc including dismantling of existing unserviceable one for the 200mm dia pipe complete all as specified and directed |
| 40 | S&F in replacement Gun metal, globe or gate valves with iron wheel head, screwed both ends for iron pipe fixed of 50mm dia sizes complete all as specified and directed |
| 41 | S&F in replacement Gun metal, globe or gate valves with iron wheel head, screwed both ends for iron pipe fixed of 40mm dia sizes complete all as specified and directed |
| 42 | S&F in replacement Gun metal, globe or gate valves with iron wheel head, screwed both ends for iron pipe fixed of 25mm dia sizes complete all as specified and directed |
| 43 | S&F in repairs Cast iron swing check type Non-Return Valve (NRV), size 100mm dia, flanged ends as per IS:5312 (Part I), PN 1.6 (16 kg/cm²) pressure rating, with bronze/GM seat and disc, including rubber insertion gaskets, nuts, bolts, washers, testing to required pressure after installation complete all as specified and directed |
| 44 | S&F in repairs Cast iron swing check type Non-Return Valve (NRV), size 80 mm dia, flanged ends as per IS:5312 (Part I), PN 1.6 (16 kg/cm²) pressure rating, with bronze/GM seat and disc, including rubber insertion gaskets, nuts, bolts, washers, testing to required pressure after installation complete all as specified and directed |
| 45 | S&F in replacement Foot valve ball type(flanged) threaded NRV type with strainer of size 150 mm dia complete all as specified and as directed. |
| 46 | S&F in replacement Foot valve ball type(flanged) threaded NRV type with strainer of size 100 mm dia complete all as specified and as directed. |
| 47 | S&F in replacement Foot valve ball type(flanged) threaded NRV type with strainer of size 80 mm dia complete all as specified and as directed. |
| 48 | Supplying, installing, testing and commissioning of LT feeder pillar box AC 415 V , 50 HZ 3 Phase 4 wire of suitable size for accomodating the following accessories totally enclosed self supporting structure / cubicle , fully compartmentalized type , suitable for outdoor use , with bottom cable entry with suitable cable glands structure made out of 3.15 mm thick CRCA steel sheet with angle iron frame work and legs of ISA 50X50X5 mm , with four legs grouted to PCC (1:2:4) type B1 , foundation block with suitable mounting arrangement for bus bars voltmeter, ammeter , changeover switch and MCCBs , hinged doors at front with suitable locking arrangement , Provision of louvers at sides , structure treated under 8 - tank metal treatment process and duly powder coated, complete all as specified and directed:- |
| 49 | BUSBAR :-(i) Aluminium bus bar 125 Amps , supported on non hygroscopic fibres and brass screws for mounting -4 NosINCOMER(a) MCCB of 4 pole of capacity 63 amps with breaking capacity of 16 KA fixed thermal and fixed magnetic setting - 01 NoOUTGOING (a) 3 Phase DOL Starter along with OV/UV Protection,Current and Voltage metering,digital display, indicators, suitable MCB, Push Buttons Which are suitable for 1 HP pump - 06 Nos(b) 3 Phase DOL Starter along with OV/UV Protection,Current and Voltage metering,digital display, indicators, suitable MCB, Push Buttons Which are suitable for 5 HP pump - 02 Nos(c) S&F 'B' curve MCB TPN/FP 16 to 32 Amps rating, 50 Hz, 415 V with rupturing capacity 10 KA - 03 Nos (d) Digital Metering Unit with ammeter, Voltmeter and Phase Indicator with Selector Switch - 01 No(e) Indicator lamp LED type - 01 Nos (Set of Three) |
| 50 | S&F in replacement Rotameter of range 200–2000 LPH with necessary fittings, alignment, testing and commissioning complete all as specified and directed |
| 51 | Taking down unserviceable Air Flow Meter of range 0–300 m³/hr with necessary fittings, testing and commissioning complete all as specified and directed. |
| 52 | Supply, installation, testing and commissioning ROF (Rate of Flow) Indicator, meter type counter-weight with float arrangement, suitable for flow measurement up to 150 Cum/Hr, including all accessories such as mounting brackets, guide wires, float assembly, counter weight mechanism, fasteners, alignment, calibration, etc., including removing old existing rate of flow indicator complete all as specified and as directed |
| 53 | Supply, installation, testing and commissioning of Loss of Head (LOH) Indicator, motorized/counter-weight type with float arrangement, suitable for measuring head loss up to 2.5 m range, including mounting supports, mechanical fittings, alignment, calibration, necessary connections, fixing to filter/pipeline system, labour, tools & tackles including removing old existing loss of head indicator complete all as specified and as directed Please Enable Macros to View BoQ information |
| 54 | Supply, installation, testing and commissioning of Loss of Head (LOH) Indicator, motorized/counter-weight type with float arrangement, suitable for measuring head loss up to 2.5 m range, including mounting supports, mechanical fittings, alignment, calibration, necessary connections, fixing to filter/pipeline system, labour, tools & tackles including removing old existing loss of head indicator complete all as specified and as directed Please Enable Macros to View BoQ information |