| 1 | S&F XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured heavy duty electric power cable 1100 volts with stranded aluminium conductor of size 10 Sqmm, 2 core laid in trenches or under road complete all as specified and as directed.Note:-Excavation and earth work shall be measured and paid separately |
| 2 | S&F XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured heavy duty electric power cable 1100 volts with stranded aluminium conductor of size 16 Sqmm, 4 core laid in trenches or under road complete all as specified and as directed. Note:-Excavation and earth work shall be measured and paid separately |
| 3 | S&F XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured heavy duty electric power cable 1100 volts with stranded aluminium conductor of size 35 Sqmm, 4 core laid in trenches or under road complete all as specified and as directed. Note:-Excavation and earth work shall be measured and paid separately |
| 4 | S&F XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured heavy duty electric power cable 1100 volts with stranded aluminium conductor of size 95Sqmm, 4 core laid in trenches or under road complete all as specified and as directed. Note:-Excavation and earth work shall be measured and paid separately |
| 5 | S & F XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured heavy duty electric power cable 1100 volts with stranded aluminium conductor of size 120 Sqmm, 4 core laid in trenches or under road complete all as specified and as directed. Note:-Excavation and earth work shall be measured and paid separately |
| 6 | S&F XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured heavy duty electric power cable 1100 volts with stranded aluminium conductor of size 150 Sqmm, 4 core laid in trenches or under road complete all as specified and as directed. Note:-Excavation and earth work shall be measured and paid separately |
| 7 | S&F XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured heavy duty electric power cable 1100 volts with stranded aluminium conductor of size 300 Sqmm, 4 core laid in trenches or under road complete all as specified and as directed. Note:-Excavation and earth work shall be measured and paid separately |
| 8 | M&L for cutting of existing bitumen road/ hard standing / PCC for laying of cable/protection pipe and making good the disturbed surfaces to match with the exisitng surface complete all as specified and directed |
| 9 | Excavation in trenches not exc 1.5 mtr wide and not exec 1.5 mtr in depth for foundation etc or for laying pipe lines and cables and getting out as in hard/dense soill complete all as specified and directed |
| 10 | Returning filling in including spreading leveling, watering and well ramming in layer not exe. 25 cm in soft/ loose soil complete all as specified and directed. |
| 11 | Removing excavated material to a distance not exc 50m and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified and directed |
| 12 | S&F Galvanised iron steel tubes, ISI marked light grade of size 50mm bore for cable protection along the poles under road under drains complete all as specified and directed |
| 13 | S&F Galvanised iron steel tubes, ISI marked light grade of size 80mm bore for cable protection along the poles under road under drains complete all as specified and directed |
| 14 | Taking down existing old ACSR from PCC/Steel poles complete all as specified and directed |
| 15 | Taking down existing old cross arms of MS channel or angle sections etc complete all as specified and directed |
| 16 | Dismantling of old insulators pin/shakle complete and keeping aside for removal complete all as specified and directed. |
| 17 | S&F duct pipe double wall ,corruugated HDPE 40mm dia outer dia conforming to IS:14930 (Part-II) of approved colour with fitting for cable protection complete all as specifid and as directed. |
| 18 | S&F duct pipe double wall ,corruugated HDPE 50mm dia outer dia conforming to IS:14930 (Part-II) of approved colour with fitting for cable protection complete all as specifid and as directed. |
| 19 | S&F duct pipe double wall ,corruugated HDPE 120mm dia outer dia conforming to IS:14930 (Part-II) of approved colour with fitting for cable protection complete all as specifid and as directed. |
| 20 | Supply and fixing LT panel pillar box cubical type of comprising size (Panel box size), with bus bar chamber having 4 wire 415 Volts, factory made dust proof vermin proof for out door use made out of CRCA sheet 3.15 mm thick powder coated, machine pressed, both side opening with double door (front & rear) in two shalves with provision of rubber beadings and locking system, danger Notice board infront and rear sides including insulated aluminium bus bar of 375 Amp capacity, 4 strip mounted on porcelain insulator, bus bar chamber shall be provided with inspection covers, each MCCB/ cubical switch shall have be independent opening , panel shall be mounted on angle iron frame and legs made from angle of size 50x50x6mm , frame and legs duly spray painted internally and externally with two coats of synthetic enamel paint over a coat of red oxide primer, legs grouted in PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) complete including all connections/control wiring incoming/out going with suitable size of copper conductor cable, Foundation is not less than 30 cm below ground level and not less than 45 cm above ground level, legs of panels will be grouted in centre of PCC foundation centre place will be open for connection of Under ground cables with cable glands including provision of following :- |
| 21 | INCOMINGMCCB 250 Amps Adjustable 36 KA-01 No.OUT GOING (a) MCCB 160 Amps 4 POLE 36 KA -01 No.(b) MCCB 25 Amps Adjustable, 25 KA, 4 Pole -07 Nos(c) MCB SPN 32 Amp -01 No.(d) LED indicating lamps ( R,Y,B) one set-01 No.(e) Volt meter 0-500 V digital with selector switch-01 No.(f) Ampere meter 0-375 Amp with selector switch-01 No. |
| 22 | Supply and fixing LT panel pillar box cubical type of comprising size (Panel box size), with bus bar chamber having 4 wire 415 Volts, factory made dust proof vermin proof for out door use made out of CRCA sheet 3.15 mm thick powder coated, machine pressed, both side opening with double door (front & rear) in two shalves with provision of rubber beadings and locking system, danger Notice board infront and rear sides including insulated aluminium bus bar of 225 Amp capacity, 4 strip mounted on porcelain insulator, bus bar chamber shall be provided with inspection covers, each MCCB/ cubical switch shall have be independent opening , panel shall be mounted on angle iron frame and legs made from angle of size 50x50x6mm , frame and legs duly spray painted internally and externally with two coats of synthetic enamel paint over a coat of red oxide primer, legs grouted in PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) complete including all connections/control wiring incoming/out going with suitable size of copper conductor cable, Foundation is not less than 30 cm below ground level and not less than 45 cm above ground level, legs of panels will be grouted in centre of PCC foundation centre place will be open for connection of under ground cables with cable glands including provision of following:- |
| 23 | INCOMINGMCCB 160Amp Adjustable thermal setting 36 KA, FP - 01 No.OUTGOING(a) MCCB 40 Amp Adjustable thermal setting 25 KA, FP-01 No.(b) Bus bar -01 No.(c) MCCB 25 Amp Adjustable thermal setting 16 KA, FP - 7 Nos (d) MCB SPN 32 Amps -01 No.(e) Street light three phase timer-singal PH module, 24 hours program, programmable every 15min, backup of 100 hrs,current capacity16Amp -1 No.(f) LED indicating lamps ( R,Y,B) one set-01 No.(g) Volt meter 0-500 V digital with selector switch-01 No.(h) Ampere meter 0-225 Amp with selector switch-01 No. |
| 24 | Supply and fixing LT panel pillar box cubical type of comprising size (Panel box size), with bus bar chamber having 4 wire 415 Volts, factory made dust proof vermin proof for out door use made out of CRCA sheet 3.15 mm thick powder coated, machine pressed, both side opening with double door (front & rear) in two shalves with provision of rubber beadings and locking system, danger Notice board infront and rear sides including insulated aluminium bus bar of 100 Amp capacity, 4 strip mounted on porcelain insulator, bus bar chamber shall be provided with inspection covers, each MCCB/ cubical switch shall have be independent opening , panel shall be mounted on angle iron frame and legs made from angle of size 50x50x6mm , frame and legs duly spray painted internally and externally with two coats of synthetic enamel paint over a coat of red oxide primer, legs grouted in PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) complete including all connections/control wiring incoming/out going with suitable size of copper conductor cable, Foundation is not less than 30 cm below ground level and not less than 45 cm above ground level, legs of panels will be grouted in centre of PCC foundation centre place will be open for connection of Under ground cables with cable glands including provision of following :- |
| 25 | INCOMING:MCCB 63 Amp Adjustable 25 KA, FP - 01 No.OUTGOING:(a) MCCB 25Amp Adjustable 16 KA, 4 pole - 02 Nos(b) MCCB 16 Amp fixed thermal magnetic 16 KA, 4 Pole - 02 Nos(c) LED indicating lamps ( R,Y,B) one set-01(d) Volt meter 0-500 V digital with selector switch-01 No.(f) Ampere meter 0-100 Amp with selector switch-01 No. |
| 26 | Supply and fixing LT panel pillar box cubical type of comprising size (Panel box size), with bus bar chamber having 4 wire 415 Volts, factory made dust proof vermin proof for out door use made out of CRCA sheet 3.15 mm thick powder coated, machine pressed, both side opening with double door (front & rear) in two shalves with provision of rubber beadings and locking system, danger Notice board infront and rear sides including insulated aluminium bus bar of 472Amp capacity, 4 strip mounted on porcelain insulator, bus bar chamber shall be provided with inspection covers, each MCCB/ cubical switch shall have be independent opening , panel shall be mounted on angle iron frame and legs made from angle of size 50x50x6mm , frame and legs duly spray painted internally and externally with two coats of synthetic enamel paint over a coat of red oxide primer, legs grouted in PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) complete including all connections/control wiring incoming/out going with suitable size of copper conductor cable, Foundation is not less than 30 cm below ground level and not less than 45 cm above ground level, legs of panels will be grouted in centre of PCC foundation centre place will be open for connection of Under ground cables with cable glands including provision of following :- |
| 27 | INCOMING:MCCB 315 Amp Adjustable 36ka ,4 pole -1 No.OUTGOING:(a) MCCB 200 Amp Adjustable 36 KA, 4 pole - 1No.(b) MCCB 25 Amp Adjustable 16 KA,4 pole - 05 Nos.(c) MCB SPN 32 Amp -01 No.(d) LED indicating lamps ( R,Y,B) - 01 set(e) Volt meter 0-500 V digital with selector switch-01 No.(f) Ampere meter 0-472 Amp with selector switch-01 No. |
| 28 | Supply and fixing LT panel pillar box cubical type of comprising size (Panel box size), with bus bar chamber having 4 wire 415 Volts, factory made dust proof vermin proof for out door use made out of CRCA sheet 3.15 mm thick powder coated, machine pressed, both side opening with double door (front & rear) in two shalves with provision of rubber beadings and locking system, danger Notice board infront and rear sides including insulated aluminium bus bar of 300 Amp capacity, 4 strip mounted on porcelain insulator, bus bar chamber shall be provided with inspection covers, each MCCB/ cubical switch shall have be independent opening , panel shall be mounted on angle iron frame and legs made from angle of size 50x50x6mm , frame and legs duly spray painted internally and externally with two coats of synthetic enamel paint over a coat of red oxide primer, legs grouted in PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) complete including all connections/control wiring incoming/out going with suitable size of copper conductor cable, foundation is not less than 30 cm below ground level and not less than 45 cm above ground level, legs of panels will be grouted in centre of PCC foundation centre place will be open for connection of under ground cables with cable glands including provision of following :- |
| 29 | INCOMING:MCCB 200 Amp Adjustable 36 KA, 4 pole - 1 No. OUTGOING(a) MCCB 100 Amp Adjustable 25 KA, 4 pole - 1 No. (b) MCCB 25 Amp Adjustable 16 KA, 4 pole - 07 Nos. (c) MCB SPN 32 Amp -01 No.(d) Street light three phase timer-singal ph module,24 hours program, programmable every 15min, backup of 100 hrs,current capacity16 Amp -1 No.(e) LED indicating lamps ( R,Y,B) -01 set(f) Volt meter 0-500 V digital with selector switch-01 No.(g) Ampere meter 0-300 Amp with selector switch-01No. |
| 30 | Supply and fixing LT panel pillar box cubical type of comprising size (Panel box size), with bus bar chamber having 4 wire 415 Volts, factory made dust proof vermin proof for out door use made out of CRCA sheet 3.15 mm thick powder coated, machine pressed, both side opening with double door (front & rear) in two shalves with provision of rubber beadings and locking system, danger Notice board infront and rear sides including insulated aluminium bus bar of 150 Amp capacity, 4 strip mounted on porcelain insulator, bus bar chamber shall be provided with inspection covers, each MCCB/ cubical switch shall have be independent opening , panel shall be mounted on angle iron frame and legs made from angle of size 50x50x6mm , frame and legs duly spray painted internally and externally with two coats of synthetic enamel paint over a coat of red oxide primer, legs grouted in PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) complete including all connections/control wiring incoming/out going with suitable size of copper conductor cable, Foundation is not less than 30 cm below ground level and not less than 45 cm above ground level, legs of panels will be grouted in centre of PCC foundation centre place will be open for connection of Under ground cables with cable glands including provision of following :- |
| 31 | INCOMING:MCCB 100 Amp Adjustable 25 KA, 4 pole - 1 No. OUTGOING:(a) MCCB 25 Amp Adjustable 16 KA, 4 pole - 02 Nos.(b) MCCB 16 Amp fixed 16 KA, 4 pole - 02 Nos. (c) MCB SPN 32 Amp -01 No.(d) LED indicating lamps ( R,Y,B) -01 set(e) Volt meter 0-500 V digital with selector switch-01 No.(f) Ampere meter 150 Amp with selector switch-01No. |
| 32 | S&F feeder pillar box cubical type of comprising size (Panel box size), with bus bar chamber having 4 wire 415 Volts, factory made dust proof vermin proof for out door use made out of CRCA sheet 3.15 mm thick powder coated, machine pressed, both side opening with double door (front & rear) in two shalves with provision of rubber beadings and locking system, danger Notice board infront and rear sides including insulated aluminium bus bar of 300 Amp capacity, 4 strip mounted on porcelain insulator, bus bar chamber shall be provided with inspection covers, each MCCB/ cubical switch shall have be independent opening , panel shall be mounted on angle iron frame and legs made from angle of size 50x50x6mm , frame and legs duly spray painted internally and externally with two coats of synthetic enamel paint over a coat of red oxide primer, legs grouted in PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) complete including all connections/control wiring incoming/out going with suitable size of copper conductor cable, Foundation is not less than 30 cm below ground level and not less than 45 cm above ground level, legs of panels will be grouted in centre of PCC foundation centre place will be open for connection of Under ground cables with cable glands including provision of following :- |
| 33 | (a) MCCB 200 Amp Adjustable 36 KA, 4 Pole (Incoming) - 01 No.(b) LED indicating lamps ( R,Y,B) one set-01(c) Volt meter 0-500 V digital with selector switch-01No.(d) Ampere meter 0-300 Amp with selector switch-01 No. |
| 34 | M&L for cable route indicator with a welded/riveted disc of inch dia and engraved with cable with cable route markar made out of angle iron 40X40X40mm thick dug in ground with in and including PCC 1:3:6 type C1 (using 20mm graded stone aggtegates) & necessary earth work complete all as specified and directed |
| 35 | S&F in replacement loop in loop out box with transparent lid IP 65 weather proof of suitable size fixed to pole / wall with suitable FI clam 20X3mm nuts,bolts and washers incl provision of 01 no miniature circuit breker (MMCBs) SPN 'C' SERIES,240 VOLTS 10KA 06 Amps and incl suitable for 1 No 50/16 sqmm x 3.5/4 core XLPE outgoing cable complete all as specified and directed |
| 36 | M&L for connection the street light point from loop in loop out box by using a two runs of singal core 1.5 sqmm.PVC insulated sheathed FR Copper conductor cable including PVC conduit/ floxole pipe of suitable dia along with one run of 1.5 sqmm FR copper cable for earth continuity conductor as earth lead for street light complete all as specified and directed |
| 37 | M&L for earthing to Panel / equipments / panels etc with & including galvanised mild steel earth plate electrode of size 60 cm x 60 cm x 6 mm thick buried vertically in ground (earth pit not less than 2.25 m below normal ground level) with top edge of the earth plate at a depth not less than 1.5 m below ground level, the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15 cm on all sides, connected to & including galvanized mild steel strip 32x6 mm as earth lead, including nuts, bolts, check nuts & washers of galvanized iron or steel and riveted/welded to earth plate at one end and other end of strip connected to Panel / equipment body / test point with two Nos nuts bolts or welding with steel structure, GI earth strip encased in and including 40mm bore GI light grade pipe with all fittings from upper edges of earth plate upto 7.5 metre above ground level fixed with and including 25x3mm flat iron clamps , bolts, nuts and washer and also including providing watering pipe 20mm bore GI pipe medium grade from earth pit to top of electrode and including funnel, wire mesh, copper lugs etc complete with earth pit in PCC 1:3:6 type C1 using 20mm graded crushed stone aggregate and 40mm thick RCC (1:2:4 type B1) cover complete all as specified and shown in electrical plate No 3 of SSR Part-I including necessary excavation and earthwork in any type of soil, returning, filling in approved soil and disposal of surplus soil to a distance not exc 50m complete all as specified and as directed. Please Enable Macros to View BoQ information |