| 1 | Dismantling single layer of Mangalore pattern tiles/lamiinated tiles in roofing/ ceiling complete all as specified and as directed . |
| 2 | Material & labour for rendering 15 mm thick on concrete surfaces in cement mortar 1:3 using water proofing compound as per manufacturers instruction complete and finishing the surface even and smooth without using extra cement including taking down old plaster complete all as specified and as directed. Note :- water proofing compound will be meausred and paid seprately. |
| 3 | Material & labour for two coats Dr Fixit roof seal classic water proofing coat at rate of application of 2.00 to 2.25 Sqm/Litre/each coat over a coat of self priming at the rate of application of 9-10 sqm/litre/coat or equivalent make as approved b GE complete as per manufacturer instruction and as directed. Note: Item shall be executed through authorised applicator of Dr fixit and contractor has to submit necessary documents of applicators duly authorised by Dr Fixit/ approved equivalent make with similar specification. |
| 4 | Supply only Liquid water proofing compound complete all as specified and as directed.Make: ROFFEE HYPROOF of Roffee construction chemicals pvt.ltd/ Conplast PROLAPIN 421 IC of FOSROC chemicals/Pidilite LW+ or equivalent make as approved by GE. |
| 5 | Taking down cement plaster on brick/ PCC block wall or stone walls etc. including racking out joints hacking for key scrubbing down with water etc. complete all as specified and as directed. |
| 6 | Material & labour for Rendering 15mm thick on fair faces of brick work or stone work concrete surfaces in CM (1:4) in patches or narrow widths complete all as specified and as directed. Note: Item is required to be done in narrow widths and patches at height upto 10 m from GL, rate quoted is deemed to be included for all necessary scaffolding and safety measures required to do works at the above heights |
| 7 | Material & labour for preparation of new/old surfaces and applying two coats of Dr Fixit Rain coat select at rate of application of 2-2.50 sqm /litre/coat Dr fixit prime seal diluted with water by vol in the ratio 2:1 (2 parts primer and one part water) and allowing the primer coat to dry for 2-3 hours on external wall/ Chajja/ Roof projection etc complete all as specified and as directed. (Make : Dr Fixit or approved equivalent make with similar specification) Note: Item shall be executed through authorised applicator of Dr fixit and contractor has to submit necessary documents of applicators duly authorised by Dr Fixit |
| 8 | Material & labour for cement mortar fillets/ reapers at spacing as per size of manglore tiles in CM 1:2 for fixing manglore tiles all as specified and as directed including demolition of damaged fillets/reapers |
| 9 | Material & labour for roof tiles mangalore pattern interlocking tiles any size as directed laid dry complete all sepecified and as directed. |
| 10 | Re-fixing roof tiles mangalore pattern interlocking tiles complete all sepecified and as directed. Note:Servicable tiles obtained from item no 01 shall be reused. |
| 11 | Material & labour Ceiling tiles for Mangalore pattern tile roofing, laid dry all as specified and as directed. |
| 12 | Refixing of ceiling tiles of magalore pattern roofing tiles laid dry all as specified and as directed. |
| 13 | Material & labour for Ridge or hip tiles to suit Mangalore pattern of roofing tiles, bedded and jointed in lime mortar 1:3 or cement mortar 1:6 complete all sepecified and as directed. |
| 14 | Re-fixing Ridge or hip tiles to suit Mangalore pattern of roofing tiles, bedded and jointed in lime mortar 1:3 or cement mortar 1:6 complete all sepecified and as directed. Note:Servicable tile obtained from item no 01 will be reused. |
| 15 | Material & labour for preparation of old/new MP roof tile including Ridge/Hip tiles surfaces by cleaning the tiles and applying two coats of antifungal tile guard paint of approved colour complete all as per manufacturer's instructions and all as specified and as directed. |
| 16 | Demolition of plain cement Concrete (unreinforced) of any description and in any position not otherwise specifically provided for complete all as specified and as directed including disposing of debris at dumping locations earmarked within INA premises. |
| 17 | Material & labour for PCC 1:2:4 type B0 (using 12.5 mm graded stone aggregate as in coping, roof kerbs etc compelet all as specified and as directed. Note : Item is required to be executed on roof at height upto 10 m above GL , rate quoted is deemed to be included for all necessary scaffolding and safety measures and formwork required. |
| 18 | Material & labour for scrapping down the existing treatment on walls by rubbing,washing etc and applying two coats of acrylic emulsion interior grade over a coat of primer over three coats of putty mixed with Dr Fixit 302 Super Latex over a coat of Asian paints smart care damp proof as thick paste all as specified by manufacturer. |
| 19 | Material & labour,10mm thick rendering in CM 1:3 on roof with liquid water proofing compound surfaces finished even and smooth without using extra cement, complete all as specified and as directed. Note:- Liquid water proofing compound shall be measured and paid separately |
| 20 | Material and Labour preparation of roof surface by throughly wire brushed, washed, dried up, cleaned of all the foreign matter and dust, and applying bitumenous primer @ 250 gms/sqm, and then laying 4mm thick APP modified bituminous membrane with non woven polyester matt as reinforcement weighting not less than 4.00Kg per sqm, laid on primed surface with torch application method by providing overlap minimum 100mm on logitudinal and 150mm on transerve direction. All angles and similar projections should be sealed well with extra care to ensure full bondage, all joints and changes in direction should be curved with cement mortar 1:3 mixed with SBR Latex @ 200ml/bag of cement all as specified and as directed. |
| 21 | Material & labour for applying one coat of solar reflective aluminium paint over APP roof membarane including preparation of old/new roof surfaces complete all as specified and as directed. |
| 22 | Taking up or down PVC Spout pipes, 25 or 32 mm bore complete all as specified and as directed. |
| 23 | Supply & fix 32mm outer dia CPVC pipes SDR 11 laid and fixed on RCC roof with necessary PCC/CM as required as in spout pipes all as specified and as directed. |
| 24 | Supply & fix 25mm outer dia CPVC pipes SDR 11 laid and fixed on RCC roof with necessary PCC/CM as required as in spout pipes all as specified and as directed. |
| 25 | Demolition of Stone slabs and tiles of any description or thickness in floors, aprons etc.all as specified and as directed. |
| 26 | Dismantling of Plain or corrugated steel / PVC sheeting of any gauge, thickness, including Nainital or similar pattern roof coverings all as specified and as directed. |
| 27 | Supply & fix 0.50mm thick Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of approved colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified complete all as specified and as directed at any height. The rates shall be inclusive of necessaty scoffolding also. |
| 28 | Supply & fix 0.5 mm thick Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of approved colour having tensile strength of 550 Mpa as in roof covering/cladding to wall,ridge etc. fixed with self tapping screws , rivetting with existing roof sheets/ valley gutters, bolting on to parepat walls etc complete as specified and as directed at any height. The rates shall be inclusive of necessary scoffolding also. |
| 29 | Dismantling wrought iron or mild steel work/Aluminium sections of any description not otherwise provided complete all as specified and as directed. |
| 30 | Supply & fix MS steel tubes conforming to I.S 1161-2014 grade Yst-240 or hollow steel sections for structural use conforming to IS 4923-2017 grade Yst 240 as in trusses ,purlins,rafters ,brackets,posts etc including cleats complete all as specified and as directed. |
| 31 | Material & labour for preparation of new steel surface and applying two coats of Apcolite Rust shield PU enamel paint over two coats of true care yellow metal primer of asian paints or equivalent in Berger ,Nerolac paint Ltd as approved as per manufacturer instructions complete all as specified and as directed. Please Enable Macros to View BoQ information |