| 1 | M&L for dewatering the sump and reservoir completely to make dry and cleaning of reservoir tank , removing sludge in semi -solid state or liquid state by manually or by pressure pump including necessary arrangement of pump, and removal of sludge, if any, to a distance exc. 1.50 Km but n. exc. 5.0 Km outside the MD land complete all as directed by Engr-in-Charge |
| 2 | M&L for chipping and cleaning of existing loose and damaged concrete surface or plaster surface carefully upto 60 mm thickness by low impact high frequency hammer or by manual chipping without damaging the existing concrete/surface including cleaning the surface by air jet and stacking & disposal of unserviceable materials outside the premises of MoD land etc complete all as specified and as directed by Engr-in-Charge. Make :Carlisle Syntec / Thermax Ltd, / Kryton Build Mat Pvt Ltd / SNI Infratech Pvt. Ltd |
| 3 | Taking down cement plaster on brick or stone walls etc including raking out joints, hacking for key, scrubbing down with water etc including removing debries directed for a distance max upto 500mm complete all as specified and directed. |
| 4 | M&L ready mix plaster 15mm thick in cement mortar 1:4 on fair faces of brick / concrete surfaces on walls, finished even and smooth without using extra cement complete all as specifed and as directed. |
| 5 | M&L ready mix plaster 20mm thick in cement mortar 1:4 mixed with and including integral water proof admixture Chemistik Chemicrete @ 200ml per bag of cement on fair faces of brick/concrete surfaces of wall, finished even and smooth and with moist curing complete all as specified and directed. |
| 6 | M&L ready mix plaster 10mm thick in cement mortar 1:3 mixed with and including integral water proof admixture Chemistik Chemicrete @ 200ml per bag of cement as in ceiling, finished even and smooth without using extra cement and with moist curing of the surface complete all as specified and directed. |
| 7 | M&L for providing and fixing welded MS wire mesh weighing not less than 1 kg/sqm on the prepared surface which should be cleaned and should be removed from dirt, fungus and all foreign material complete all as specified and directed |
| 8 | M&L for providing and applying jacketing around columns with Micro concrete M40 including all lifts, shuttering, drilling holes and fixing shear anchor as per specification complete all as specified and directed. Note:(i) Reinforcement shall be measured and paid separately.(ii) Rates including jacketing, formwork and micro concrete. |
| 9 | Dismantling wrought iron or mild steel work of any description not otherwise provided for, complete all as specified and directed. |
| 10 | S&F rolled mild steel work in joist, channel, angle or tee section, fixed indepently without connecting plates etc (cut to ordinary lengh i.e. withing 20mm of the length indicated ) including necssary welding and joints etc; steel confirming to Fe-410 Gde E-250 quality B complete all as specified and directed. |
| 11 | Dismantling expanded metal / welded wire fabric n.exc. 4 kg per sqm any thickness or mesh, fixed with steel or wood fillets, if any complete all as specified and as directed |
| 12 | S&F welded steel wire fabric n. exc. 4 kg per Sqm supplied and fixed complete to wood or steel members complete all as specified and as directed |
| 13 | Demolition of cement concrete of any type and in any position for below or above ground floors, complete all as specified and directed |
| 14 | M&L for PCC (1:3:6) type C-2 using 40mm graded agg as in 75mm thick as in plinth protection/footpath. finished even & smooth using extra cement and including WPC by weight 3% of total cement content complete all as specified and directed |
| 15 | M&L for PCC 1:2:4 type B-1 using 20mm graded stone aggregate as in coping, kneelers, apex, stones, bed plates, kerbs and likes including weathering, slightly rounded or chamfered angles and throating and including WPC by weight 3% of total cement content, complete all as specified and directed. |
| 16 | M&L applying two coats of synthetic enamel paint over a coat of red oxide, zinc chromate primer on new or previously untreated steel & iron surfaces of any description, not otherwise described, over 10cm width or girth including necessary preparation of surfaces complete all as specified and directed. |
| 17 | M&L steel deformed bars (TMT bars) 10mm dia & over in reinforcement, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends & binding with & including mild steel wire (annealed) not less than 0.9mmdia or securing with clips complete all as specified and directed. |
| 18 | M&L wire brushing, cleaning the surface from loose dirt, mortar dropping etc apply one coat of primer AC 10 pure acrylic seater allow to dry for 4-5 hrs. Thereafter, applying two coats of Chemistik ACP 100 (Anti-carbonation coating) all to cure for 72 hrs. complete all as per manufacturer specifications and as directed by Engr-in-Charge, Anti-carbonation coating having the following properties :-(a) Vapour permeability - < 0.13 ASTM D1653(b) Diffusion resistance Co2: Min : 22.00g/(sqm d)(c) Diffusion air layerthickness : Min 11.00/m Din (d) 53122 pt I adhesion min: 2.00 ASTM d-4541(e) Tensile strength Min 1.5 Mpa(f) ASTM D 2370 , allow to cure for 72 hrs. |
| 19 | M&L for filling all visible cracks joints in floor slab etc with Chemistik Conjoint-50 (Polymeric joint sealeant) by first priming with Chemistik Primer 10. Thereafter, apply one bond coat of Chemistik EP TAC 404 (Epoxy Tac Coat) prior to laying M-15 concrete in 30mm thickness laid to level to finish. Allow to moist cure for 7 days complete all as per manufacturer specifications and as directed by Engr-in-Charge. |
| 20 | M&L applying on new concrete or plastered surfaces one coat of Chemistik CW 100 G (tank waterproof coating) ,allow to cure for 72 hrs. Thereafter, applying three coats of Chemistik Epoxy Slurry mortar heavy duty tank coating at an interval of 4-6 hrs between each coat complete all as per manufacturer specifications and as directed by Engr-in-Charge |
| 21 | M&L providing the following treatment to water reservoir complete all as per manufacturer specifications and as directed by Engr-in-Charge :- (i) Wire brushing, cleaning the surfaces of walls, removing loose dirt, dust, gravel etc on external top and side wall surfaces. (ii) Fill all cracks, joints with Chemistik Primer 10 and filling the same with Chemistik Conjoint-50 (Polymeric joint sealant) , allow to cure for 72 hrs.(iii) Apply one coat of Chemistik CW-100G (Tank water proof caoting) allow to cure to 24 hrs. (iv) Apply two coats of Chemistik ACP 100 (Anti-carbonation paint) allow to cure for 72 hrs . Anti carbonatnion coating to have following properties:- (a) Vapour permeability - < 0.13 ASTM D1653(b) Diffusion resistance Co2: Min : 22.00g/(sqm d)(c) Diffusion air layerthickness : Min 11.00/m Din (d) 53122 pt I adhesion min: 2.00 ASTM d-4541(e) Tensile strength Min 1.5 Mpa(f) ASTM D 2370 , allow to cure for 72 hrs. |
| 22 | M&L for scaling / volumetric marking with thick paint on internal surfaces of static water tank including all necessary preparation complete all as directed by Engr-in-Charge |
| 23 | M&L for applying Epoxy Resin Based Concrete Bonding Agent for proper bonding between old surface with micro-concrete/new surface. The bonding agent shall be a two component solvent free epoxy supplied as ready to use at site. The product shall have a minimum pot life of 120 Min at 35°C and an open time of atleast 4-6 Hours @ 30°C up to which new concrete can be poured. It shall develop a minimum compressive strength of 40 MPa and a bond Strength of 11 MPa, complete all as directed by Engr-in-Charge. Make: Carlisle Syntec / Thermax Ltd / Kryton Build Mat Pvt Ltd / SNI Infratech Pvt. Ltd |
| 24 | M&L for applying ready to mix cement polymer plaster with high quality polymer additives (Polymer plaster) with 4 MPa compressive strength of required thickness over the entire cleaned surfaces including all tools and tackles, etc. in damaged areas in 40 to 50 mm thickness including leveling profliling etc complete all as directed by Engr-in-Charge. Make:- Krishna Conchem, STP or equivalent |
| 25 | M&L for removing of peepful tress or any type trees / vegetations (Exceeding dia of trunk 3 inch) with root from wall, roof slab, over head tank portions, shafts, rain water pipe portions etc, and applying acid or suitable chemical to the affected area to arrest further growth and making good damaged portions with PCC 1:2:4 type B-0, complete all as directed by Engr-in-Charge |
| 26 | Supply only water proofing liquid compound as URP complete all as specified and directed by Engr-in-Charge. |
| 27 | Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m depth for foundation etc or for shafts, wells cesspits manholes pier holes etc not exceeding 10 sqm on plan and not exceeding 1.5m depth in hard / dense soil etc complete all as specified and directed |
| 28 | Returning, filing in, excavated soil including spreading, levelling, watering and well ramming in layers not exceeding 25cm etc complete all as specified and directed |
| 29 | Removal of excavated soil not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting points etc complete all as specified and directed |
| 30 | M&L for concrete bed 1:3:6 type C-2 as in drain pipes including packing under, and haunching against the side of pipes after they are laid and tested in 150mm bore of pipe, complete all as specified and directed. |
| 31 | M&L for SGSW drain pipes laid in trenches of 150 mm internal diameter of pipe and jointed including demolition and breaking up drain pipe (salt glazed ware, AC or reinforced concrete ) set in cement mortor as specified complete all as specified and directed. |
| 32 | M&L for SGSW drain pipes laid in trenches of 200 mm internal diameter of pipe and jointed as including demolition and breaking up drain pipe (salt glazed ware, AC or reinforced concrete ) set in cement mortor specified complete all as specified and directed. |
| 33 | M&L for reinforced concrete pipes, class NP-2, laid and jointed with collars of 150 mm bore of pipe including demolition and breaking up drain pipe (salt glazed ware, AC or reinforced concrete ) set in cement mortor specified complete all as specified and directed. |
| 34 | M&L for reinforced concrete pipes, class NP-2, laid and jointed with collars of 200 mm bore of pipe including demolition and breaking up drain pipe (salt glazed ware, AC or reinforced concrete ) set in cement mortor specified complete all as specified and directed. |
| 35 | M&L for Pre-cast cement concrete Tyep B1 (1:2:4) 20 mm graded aggregate block masonry with solid blocks, exc. 10 m in width and setting in CM 1:4 including demolition of old PCC block masonary complete all as specified and diretced |
| 36 | M&L Brickwork with subclass‘B’ bricks, straight or curved on plan exc. 6m mean radius built in cement mortar 1:6 including demolition of old brick work complete all as specified and directed. |
| 37 | M&L for walling of random rubble,uncoursed well bonded, bedded and solidly hearted built in cement mortar 1:6 including demolition of old stone masonary work complete all as specified and diretd |
| 38 | M&L for rendering on fair faces of brick work or concrete surface of wall 15mm thick in CM 1:4 and to be finished even and smooth with out using extra cement complete all as specified and directed |
| 39 | M&L for rendering on fair faces of brick work or concrete surface of wall 15mm thick in CM 1:6 and to be finished even and smooth with out using extra cement complete all as specified and directed |
| 40 | M&L for Precast cement concrete 1:2:4 type B1 using 20 mm graded stone aggregate as in landings, cover slab (for manholes etc) and similar work including necessary form work and set in CM 1:6 including demolition of Old Cement Conctete reinforced in ground Floor complete all as specified and directed. |
| 41 | Mild Steel TMT bar 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders cut to length bent to shape required including cranking, bending spirally for hoping for columns hooking ends and binding with & including Mild Steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed |
| 42 | S&F in repair to precast moulded reinforced cement concrete facorty made precast moulded and vibo compacted manhole covers with necessary handles of sizes 900x450x100mm medium duty confirming to IS -12592-2002 placed in position wherever required complete all as specified and directed. Note :- Manhole cover shall be of \\"BMC Pattern\\" precast slab as in RMC M30 has to be purchase from approved manufacturer. |
| 43 | S&F in repair to Heavy duty precast moulded Steel Fiber reinforeced cement concrete facorty made precast moulded and vibo compacted manhole covers with necessary handles of sizes 600x600x50mm thick arounded with steel strip 50x1.25mm reinforced as per manufacturers design in manufactured process laid over existing drain complete all as specifed and directed by Engr-in-Charge. Make of SFRC Manhole / Drain Cover and frame / M/S PS Concrete / M/S KK Manhole / SS. Note :- Contractor shall provide PV alongwith manufacturer test certificate of SFRC Cover. |
| 44 | M&L for extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred / stopped ends etc. complete all as specified and directed. |
| 45 | M&L for Cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (½ round or ¾ section) in cement concrete 1:2:4 type B-1 smooth finished ,and reforming benching as required for 150 mm internal dia of pipe complete all as specified and directed. |
| 46 | M&L for Cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (½ round or ¾ section) in cement concrete 1:2:4 type B-1 smooth finished and reforming benching as required for 200 mm internal dia of pipe complete all as specified and directed. |
| 47 | M&L for sucking out sewage water through sewage tanker from the man hole/ septic tank/ soakage well in different location and disposal (5000 ltrs capacity) by using high pressure super sucker machine vehicle mounted jetting cum suction unit to be capable of air lefting of dense waste/ sludge like mud slurry, small stones, debries, grit etc., from sewer lines, through vaccum mode and capable of jetting sewer lines of dia 150mm to 450mm including skilled driver and operator for supervising of cleaning of sewage line and also remove sludge / silt / mud / debries etc., out side the MD land complete all as directed by Engr-in-charge. |
| 48 | M&L for cleaning of choked sewer line by diesel running vehicle mounting hydraulic operated high pressure suction cum jetting sewer cleaning machine fitted with pump having minimum 4000 litres suction capacity and water jetting tank capacity including skilled operator, supervising engineer etc., for cleaning and partial desilting of manholes and dechoking of sewer lines. Dechoking and flushing of sewer line from one manhole to another by high pressure jetting system of 2200 PSI for sewer line of any dia. Foul material shall be disposed off at authorized dumping site declared by local administration outside the Ministry of defence land complete all as directed by Engr-in-charge. Please Enable Macros to View BoQ information |
| 49 | M&L for cleaning of choked sewer line by diesel running vehicle mounting hydraulic operated high pressure suction cum jetting sewer cleaning machine fitted with pump having minimum 4000 litres suction capacity and water jetting tank capacity including skilled operator, supervising engineer etc., for cleaning and partial desilting of manholes and dechoking of sewer lines. Dechoking and flushing of sewer line from one manhole to another by high pressure jetting system of 2200 PSI for sewer line of any dia. Foul material shall be disposed off at authorized dumping site declared by local administration outside the Ministry of defence land complete all as directed by Engr-in-charge. Please Enable Macros to View BoQ information |