| 1 | Excavation in trenches n .exc 1.5 mtr wide and not exec 1.5 mtr depth and getting out in looses/soft soil complete all as specified |
| 2 | Excavation in trenches exc 1.5 mtr wide and n exc 3.0 mtr depth and getting out in looses/soft soil complete all as specified |
| 3 | Returing filling in incl spreading leveling, watering and well ramming in layer not less than 25 cum each layer all as specified. |
| 4 | Removing excavated material to a distance not exc 50M and depositing where directed at a level n.exc 1.5 mtr above the starting point complete all as specified |
| 5 | M&L filling of dry sand under and around LT cable to provide sand cushioing and in sub stn ducts/trenches complete all as directed. |
| 6 | M/L for brick well burnt locally available sub class 'B' laid over sand cushioning to cable in trenches keeping width of brick parallel to the length of cable complete all as specified and directed. |
| 7 | M&L PCC 1:4:8 type D 2 using 40 mm graded stone aggregate for foundation of pole & stay complete all as directed |
| 8 | M&L PCC 1:3:6 type C 2 using 40 mm graded stone aggregate for filling of pole & stay complete all as directed |
| 9 | M&L PCC 1:2:4 type B2 using 20 mm graded stone aggregate for copining of pole complete all as directed |
| 10 | Taking out old unserviceable PCC/steel tubular poles 9 mtr long and supply and erection of steel tublar swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts, screws as specified type 410 SP-31 (9.0 mtr long) and shifting of conductors and insulators etc incl painting the exposed portion of the pole with two coats of aluminium paint over a coat of red oxide primer and internally through out plus embedded portion with two coats of black bituminous paint over a coat of red oxide primer. Marking of pole number with black paint in yellow circle all as specified and directed by Engr-in-Charge. |
| 11 | Taking out old UNSV cable of any size and supply, laying, jointing and testing of cable XLPE 16 sqmm 2 core insulated, armoured, heavy duty LT under ground cable 1100 Volts grade with aluminium conductor laid in trenches, on poles, through pipes, fixed to walls etc cross sectional area for following sizes, including taking down old, complete, all as specified and directed. |
| 12 | Taking out old UNSV cable of any size and supply, laying, jointing and testing of cable XLPE 16 sqmm 4 core insulated, armoured, heavy duty LT under ground cable 1100 Volts grade with aluminium conductor laid in trenches, on poles, through pipes, fixed to walls etc cross sectional area for following sizes, including taking down old, complete, all as specified and directed. |
| 13 | Taking out old UNSV cable of any size and supply, laying, jointing and testing of cable XLPE 25 sqmm 3.5 core insulated, armoured, heavy duty LT under ground cable 1100 Volts grade with aluminium conductor laid in trenches, on poles, through pipes, fixed to walls etc cross sectional area for following sizes, including taking down old, complete, all as specified and directed . |
| 14 | Taking out old UNSV cable of any size and supply, laying, jointing and testing of cable XLPE 35 sqmm 3.5 core insulated, armoured, heavy duty LT under ground cable 1100 Volts grade with aluminium conductor laid in trenches, on poles, through pipes, fixed to walls etc cross sectional area for following sizes, including taking down old, complete, all as specified and directed . |
| 15 | Taking out old UNSV cable of any size and supply, laying, jointing and testing of cable XLPE 50 sqmm 3.5 core insulated, armoured, heavy duty LT under ground cable 1100 Volts grade with aluminium conductor laid in trenches, on poles, through pipes, fixed to walls etc cross sectional area for following sizes, including taking down old, complete, all as specified and directed . |
| 16 | Taking out old UNSV cable of any size and supply, laying, jointing and testing of cable XLPE 70 sqmm 3.5 core insulated, armoured, heavy duty LT under ground cable 1100 Volts grade with aluminium conductor laid in trenches, on poles, through pipes, fixed to walls etc cross sectional area for following sizes, including taking down old, complete, all as specified and directed . |
| 17 | Taking out old UNSV cable of any size and supply, laying, jointing and testing of cable XLPE 95 sqmm 3.5 core insulated, armoured, heavy duty LT under ground cable 1100 Volts grade with aluminium conductor laid in trenches, on poles, through pipes, fixed to walls etc cross sectional area for following sizes, including taking down old, complete, all as specified and directed. |
| 18 | Supply and fixing of moulded case circuit breaker Four pole 400Amps 35 KA capacity 415V 50Hz with adjustable thermal and magnetic relay, Ics=100% Icu, 75% Icu incl taking out the old unserviceable complete all as specified and directed by Engr-in-Charge.. |
| 19 | Supply and fixing of moulded case circuit breaker Four pole 250Amps 35 KA capacity 415V 50Hz with adjustable thermal and magnetic relay incl taking out the old unserviceable complete all as specified and directed by Engr-in-Charge.. |
| 20 | Supply and fixing of moulded case circuit breaker Four pole 200Amps 25 KA capacity 415V 50Hz with adjustable thermal and magnetic relay incl taking out the old unserviceable complete all as specified and directed by Engr-in-Charge.. |
| 21 | Supply and fixing of moulded case circuit breaker Four pole 160Amps 25 KA capacity 415V 50Hz with adjustable thermal and fixed magnetic relay incl taking out the old unserviceable complete all as specified and directed by Engr-in-Charge.. |
| 22 | Supply and fixing of moulded case circuit breaker Four pole 125Amps 35 KA capacity 415V 50Hz with adjustable thermal and fixed magnetic relay incl taking out the old unserviceable complete all as specified and directed by Engr-in-Charge.. |
| 23 | Supply and fixing of moulded case circuit breaker Four pole 100Amps 25 KA capacity 415V 50Hz with adjustable thermal and fixed magnetic relay incl taking out the old unserviceable complete all as specified and directed by Engr-in-Charge.. |
| 24 | Supply and fixing of moulded case circuit breaker Four pole 100Amps 16 KA capacity 415V 50Hz with adjustable thermal and fixed magnetic relay incl taking out the old unserviceable complete all as specified and directed by Engr-in-Charge.. |
| 25 | Supply and fixing of moulded case circuit breaker Four pole 63Amps 25 KA capacity 415V 50Hz with adjustable thermal and fixed magnetic relay incl taking out the old unserviceable complete all as specified and directed by Engr-in-Charge. |
| 26 | M & L for GI tube light grade galvanised with all fittings laid along the pole/in trenches / under road or floor of 40 mm bore including removing the rusted old one complete all as specified and directed. |
| 27 | M & L for GI tube light grade galvanised with all fittings laid along the pole/in trenches / under road or floor of 50 mm bore including removing the rusted old one complete all as specified and directed. |
| 28 | M & L for GI tube light grade galvanised with all fittings laid in trenches / under road or floor of 80 mm bore including removing the rusted old one complete all as specified and directed. |
| 29 | M/L for replacement of Earthing complete with GI earth plate 60x60cmx6mm thick electrode and 4mm dia GI wire as earthing lead.burried directly in ground ( earth pit not less then 2.25 metres deep below ground level ) with top edge of the plate not less then 1.5 metres below normal ground level. connected to GI wire earth lead 4 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 of SSR Part-I and incl earth work,PCC pit and RCC cover,watering pipe 20 mm dia light grade,funnel,wire mesh,protection pipe 15 mm dia light grade up to 7.5 mtr length of earth wire,charcoal dust and salt etc and connected to earthing test point all as specified and as directed by Engr-in-charge. |
| 30 | M & L for earth continuity conductor using GI strip 32 x 6 mm as earthing lead complete all as directed incl taking down the old unserviceable complete. |
| 31 | Supply and installation of on load change over switch in sheet metal enclosure of capacity 63 Amps, 4 pole complete all as specified and directed. |
| 32 | S & F in replacement of Integral LED street light luminaires complete comprising of epoxy powder coated housing, enclosed with glass cover in front 50W mounted on MCPCB suitable for 50 mm dia pipe in gress protection IP-66 complete all as specified and as directed . |
| 33 | S & F in replacement of Integral LED street light luminaires complete comprising of epoxy powder coated housing, enclosed with glass cover in front 90W mounted on MCPCB suitable for 50mm dia pipe in gress protection IP-66 complete all as specified and as directed. |
| 34 | S & F in replacement of Integral LED street light luminaires complete comprising of epoxy powder coated housing, enclosed with glass cover in front 60W mounted on MCPCB suitable for 50mm dia pipe in gress protection IP-66 complete all as specified and as directed . |
| 35 | S & F in replacement of Integral LED street light luminaires complete comprising of epoxy powder coated housing, enclosed with glass cover in front 70W mounted on MCPCB suitable for 50mm dia pipe in gress protection IP-66 complete all as specified and as directed . |
| 36 | Taking down after disconnection of old UNSV of street/security/road/post top light fitting and supply and fixing of LED based energy saving & environment friendly long life versatile luminaire made in pressure die cast housing and heat sink with aluminium extruded with IP-65 of 30 watt complete with front toughened glass cover including connection with 2.5 sqmm 3 core PVC insulated copper wire complete all as specified. |
| 37 | Tking down after disconnection of Old UNSV of high mast light fittings and supply and fixing in replacement of LED based energy saving & enviorment friendly long life versatile flood light Lumos IP-65 of 200 W complete with front glass cover complete as specified. . |
| 38 | M & L for earth continuity conductor /main earthing lead fixed to wall/batten or recess/chases or buried in ground or drawn in conduit /pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 6mm dia galvanised iron or steel wire. |
| 39 | M & L for Painting of steel tubular pole 9.0 mtr long, by applying one coat of alluminium paint after scraping / brushing and cleaning the rust on pole and cross arms . Alluminium painting will be done on pole above 1.5 Mtr hight from ground level and balance 1.5 mtr from ground level will be painted by alternate layer of black and white enammelled paint ( 30 cms each) Pole Nos will be written on pole by black paint in yellow circle of 150mm dia all as directed by Engr in charge. |
| 40 | Taking down u/s ceiling fan any size or sweep after disconnecting, dismantling and removal to trade workshop for repair, complete all as specified and directed |
| 41 | Opening the unserviceable/burnt fan 1200/1400 mm sweep and cutting of old burnt copper winding and rewinding the same with super enamelled copper winding wire of suitable gauge including insulating material such as paper cotton sleeves, varnish, reassembling, testing and connecting for satisfactory run, complete all as specified and directed. |
| 42 | Supply and replacing of Ball bearing of the ceiling fan (any sweep) as per existing size incl greasing/oiling, complete all as specified and directed. Make:- SKF/ NBC or Equivalent |
| 43 | Supply and replacenment gun metal bushes of surface size for ceiling fan/ceiling fan incl necessary mechanical work, complete all as specified and directed. |
| 44 | Supply and replacing of cord cable, three core 0.5 Sqmm PVC insulated copper conductor cable for connecting ceiling fan, complete all as specified and directed. . |
| 45 | Supply and replacing electronic step type fan regulator 240 Volt, 50 C/S, five step, suitable for 1200/1400mm sweep ceiling fan,complete all as specified and directed. . |
| 46 | Supply and Fix Capacitor of of 2.5 MFD for ceiling fan, complete all as specified and directed. |
| 47 | Supply and Fix Capacitor of 4 Mfd for exhaust fan, complete all as specified and directed. |
| 48 | M & L for replacement ceiling fan blade set of three heavy duty suitable for 1200/1400mm sweep of suitable approved make as direcetd by Engr-in-Charge. |
| 49 | Supply and Fix PVC canopy for ceiling fan 1200/1400mm sweep complete for various makes/model of fan, complete all as specified and directed. |
| 50 | M & L for Disconnecting and taking down exhaust fan and blades any size or sweep after dismantling and removal to trade workshop for repair, complete all as specified and directed. |
| 51 | M & L for strip opening and cutting of old burnt copper winding of exhaust fan and rewinding of exhaust fan motor of sweep 450mm with super enamelled copper winding wire of suitable gauge including insulating material such as paper cotton sleeves, varnish, re-assembling, testing and connecting for satisfactory run, complete all as specified and directed. |
| 52 | All as per srl item No. 51 here-in-before, but of 300mm sweep. |
| 53 | M & L for Ball bearing of exhaust fan of any size/make as per the existing, complete all as specified and directed. Make: SKF/NBC or equivalent make. |
| 54 | M & L for painting the exhaust fan including louvers of size 300/450mm sweep with two coats of synthetic enamel paint after cleaning and making the surface of oil/dust free, complete all as specified and directed. |
| 55 | M & L for servicing of Geyser by disconnecting the electric and water supply connections, dismantling the geysers of any size, type & capacity and opening the top and bottom cover, thermostat, heating element, safety valve, vent pipe, separating inner & outer tank, removing glass wool insulation complete and keeping aside for re-use after de-scaling of inner tank by liquid chemical and with pressure water jet and assembling back the geyser including re-installation on wall with studs, nuts & bolts complete and testing after reconnecting electric and water connections, complete all as specified and directed. |
| 56 | Supply and fiixing of Heating element for geyser of cap 1.5KW, AC 230 Volts, 50 Hz (as per sample), complete all as specified and directed. Make:- Micron/ Bajaj/ Havells |
| 57 | Supply and fiixing Heating element for geyser of cap 2.0KW, AC 230 Volts, 50 Hz (as per sample), complete all as specified and directed. Make:- Micron/Bajaj/havells |
| 58 | Supply and fiixing thermostat for Geyser of capacity 25/50/100 ltr (long size) with temperature setting adjustment range from 40 to 85°C, ISI Marked, complete all as specified and directed. Make:- Philips/ Bajaj/ Venus |
| 59 | Supply and fiixing Geyser Syphon Assembly Set suitable for 25 ltr capacity geyser, fixed in replacement, complete all as specified and directed. |
| 60 | All as per item Srl No. 59.00 above but for 50 Ltr capacity. |
| 61 | All as per item Srl No. 59.00 above but for 100 Ltr capacity. |
| 62 | S & F Rubber gasket for water heater storage type of any capacity fixed, in replacement and suitable as per the existing, complete all as specified and directed |
| 63 | Taking down old unserviceable plug top from geyser connection and Supply and Fixing in replacement plug top 15/16 Amps for Geyser, complete all as specified and directed. Make:- Havells/ Anchor/ Leader/ Plaza. |
| 64 | S & F PVC sheathed three core copper conductor flexible wire of size 2.5 Sqmm for connecting geyser, complete all as specified and directed. |
| 65 | S & F sheet metal enclosure with 2 pin and earth plug and socket complete with and including MCB 20 Amps 240 volts heavy duty. Make:-Hager/Legrand/Siemens. |
| 66 | Supply and replacement of safety valve for geyser of 25/35/50 litre capacity, complete all as specified and directed |
| 67 | Supply and replacement of non return valve 15mm dia for geyser of 25/50 litre capacity, complete all as specified and directed. |
| 68 | Supply and replacement of heavy duty PVC connector 600mm long 15mm dia with PTMT nut for geyser of 25/50 litre capacity, complete all as specified and directed. |
| 69 | M & L for disconnecting and taking out geyser of capacity 25 litre and replacement of copper/SS inner tank and refilling of glass wool, refixing, connecting and testing, complete all as specified and directed. |
| 70 | All as per item Srl No. 69.00 above but for 50 Ltr capacity. |
| 71 | All as per item Srl No. 69.00 above but for 100 Ltr capacity. |
| 72 | Taking down old unserviceable and supply & fixing stop cock brass 15mm dia not less than 200 grams, complete all as specified and directed. |
| 73 | M & L for preparation of surface of Geyser of capacity 25/50/100 Ltr by scarping, removing old paint etc and applying two coats of synthetic enamel paint over one coat of red oxide primer,complete all as specified and directed. |
| 74 | Supply and fixing of geyser Bolt 120mm Long with nut & washers, complete all as specified and directed |
| 75 | Servicing and overhauling of refrigerator of 165 to 200 ltr capacity of various make and model incl transporting to workshop & back complete. |
| 76 | Taking out the burnt/ unserviceable compressor from the refrigerator of 165 to 200 ltr capacity and supply & fixing the same as per the existing complete all as specified and directed. |
| 77 | M & L for replacement of thermostat for refrigerator of 165 to 200 ltr capacity. |
| 78 | M & L for replacement of thermal relay for refrigerator of 165 to 200 ltr capacity. |
| 79 | M & L for charging of refrigerant R134A and testing for proper cooling and leakage complete for refrigerator and deepfreezers of any capacity complete all as specified and directed. |
| 80 | Taking out the burnt/ unserviceable compressor from the refrigerator of 210 to 320 ltr capacity and supply & fixing the same as per the existing complete all as specified and directed. |
| 81 | M & L replacement of thermostat for refrigerator of 210 to 320 litre capacity. |
| 82 | M & L for replacement of thermal relay for refrigerator of 210 to 320 litre capacity. |
| 83 | Servicing and overhauling of defreezer of 210 to 400 ltr capacity of various make and model incl transporting to workshop complete. |
| 84 | Taking out the burnt/ unserviceable compressor from the defreezer of 210 to 320 ltr capacity and supply & fixing the same as per the existing complete all as specified and directed. |
| 85 | M & L for replacement of thermostat for defreezer of 210 to 320 litre capacity. |
| 86 | M & L for replacement of thermal relay for defreezer of 210 to 320 litre capacity. |
| 87 | Supply and fix electric water heater, storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece including old unserviceable geyser deposited to MES/EM store yard complete all as specified and directed by Engineer in Charge. |
| 88 | M & L for painting to the outer surfaces of refrigerator of size 165 to 320 litre with two coats of synthetic enamel paint after cleaning the surface oil/dust free and making the surfaces smooth by filling putty where required, complete all as specified and directed. |
| 89 | M & L for repair to unserviceable/burnt stabilizer of 3 KVA to 5 KVA capacity, rewinding the same with super enamelled copper winding wire of suitable gauge including insulating material such as paper cotton sleeves, varnish, reassembling, replacement of knobs, LED's etc. and making fully functional on load as connected to Refrigerator/Deep freezer/AC, complete all specified and directed by Engr- in-charge. |
| 90 | All as per item Srl No. 89.00 above but for stablizer of 1 KVA capacity. |
| 91 | M & L for repair to unserviceable/burnt piller heater of capacity 1000/1500/2000 watt, single phase 230volts by replacing the heater rod,blower motor, switches including wiring etc. complete all specified and directed by Engr- in-charge. |
| 92 | M & L for painting the exhaust fan including louvers of size 300/450mm sweep with two coats of synthetic enamel paint after cleaning and making the surface of oil/dust free, complete all as specified and directed. |
| 93 | S&F in replacement PVC cable copper conductor multi strandrad flexible 23/.0076 twin core and making connections from ceiling rose to fan complete all as directed. Make :Plaza/ Finolex. |
| 94 | S&F Fresh air fan motor of capacity 1/6 HP 230 volts, 50 Hz, AC supply suitable for 250/200 mm size Fresh air fan as per sample complete all as spd and directed. |
| 95 | Supply only exhaust fan motor capacity 1/4 HP 230 volts suitable for 230 mm size exhaust fan complete all as directed. |
| 96 | Repair /Supply and fixing Exhaust fan 300 mm sweep(steel Body) , 1250 RPM, non metallic resin body, single phase 240 volts AC 50 Hz and connecting up complete including louvers and provision of copper cable 3 core of size 0.5 sqmm for connection from ceiling rose to fan complete all as specified and as directed. |
| 97 | S&F fresh Air fan 200mm sweep with louvers including connecting with suitable size of copper conductor from ceiling rose to fan complete all as specified and directed. Make: Havells/Bajaj/CG. |
| 98 | Supply and fix inner Steel tank for geysers of capacity 50 ltr as per existing of approved make complete all as directed. |
| 99 | Supply & Fix inner Steel tank for geysers of capacity 25/35 ltr as per existing of approved make complete all as directed |
| 100 | Supply and Fix top cover for geysers (confirming to IS) suitable for any makes/capacity/type of geysers installed at site duly painted (spray) in two coats with enameled (Deco) paint of colour & shade as directed. |
| 101 | Supply and Fix bottom cover for geysers (Confirming to IS) suitable for any make/capacity/type of geysers installed at site duly painted (spray) in two coats with enameled (Deco) paint of colour & shade as directed complete with inspection plate in two pieces. |
| 102 | S&F factory made epoxy powder coated Distribution Board SPN-12 ways (SPN MCB DB) with metal door (IP-43 protection) fabricated from minimum 1.6mm thick CRCA sheet and fixed flush to wall and suitable for universal mounting and including 200 Amp rated copper bus bar, neutral bar, standard DIN rail, Earth bar and cable ties for cable management, top and bottom removeable gland plates with knockouts and suitable for one SPN- MCB 25/40 Amp as incomer and 10 SP MCBs outgoing complete all as specified and conforming to IS : 8623. |
| 103 | S&F factory made epoxy powder coated Distribution Board SPN-8 ways (SPN MCB DB) with metal door (IP-43 protection) fabricated from minimum 1.6mm thick CRCA sheet and fixed flush to wall and suitable for universal mounting and including 200 Amp rated copper bus bar, neutral bar, standard DIN rail, Earth bar and cable ties for cable management, top and bottom removeable gland plates with knockouts and suitable for one SPN- MCB 25/40 Amp as incomer and 10 SP MCBs outgoing complete all as specified and conforming to IS : 8623. |
| 104 | S&F MCB SP 6-32 Amps 240 volts curve 'C' series 10 KA 50 HZ complete all as specified and directed. |
| 105 | Supply & Fix MCB SPN 40- 63 Amps, 240 Volts, 10 KA capacity C' curve . |
| 106 | Disconnecting the electric supply from the mains, transporting the window/split type air conditioner 2.0 Ton capacity from original location to workshop to carry out the servicing complete and re-fixing at the original position after repairs and making the ACs fully functional and testing for satisfactory working, complete all as specified and directed. |
| 107 | Notes :- Amount of Credit Schedule for Schedule 'A' Part-ll shall be deducted from total quoted amount of BOQ to arrive at the contract sum. Please Enable Macros to View BoQ information |