| 1 | Dismantling of wrought iron or mild steel work any description and fixed in any position complete all as specified and directed. |
| 2 | Excavating in post holes (or similar holes) each n exc 0.5 cu m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm in soft/loose soil complete all as specified and directed. |
| 3 | M&L for cement concrete type C2, 1:3:6 using 40 mm graded stone aggregate as in embedding of fencing post etc, complete all as specified and directed. |
| 4 | S&F for mild steel work in posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc., flat iron fillets (for securing wire mesh etc,.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 complete all as specified and directed. |
| 5 | Dismantling fencing wire mesh, any type complete all as specified and directed. |
| 6 | S&F in repairs galvanised 2 strand steel barbed wire 2.24 mm dia barbed with 2 mm dia barbs at 75 mm spacings and straining and fixing to any type of standard rails straining bolts including securing or type at crossings with and provision of galvanised mild steel wire staples or steel pins, etc complete all as specified and directed. |
| 7 | Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provision of binding wire complete all as specified and directed. |
| 8 | Supply only chain link fence of any size (oblong) of 3-4mm dia GI wire complete all as specified. |
| 9 | M & L preparation of new steel surfaces of any description exc 10 cm width or girth and applying two coat of synthetic enamel paint over red oxide complete all as specified and directed |
| 10 | S&F in repairs Concertina Coil 600 mm dia (at streatched position) made out of hot dipped galvanised steel wire coated with CLR and anti corrosive paint. Weight of each bundle is not less than 9.5 Kg and should have cover 6 RM of length and minimum rounds of circle is not less than 25 per 3 RM, fixed over barbed wire at point where coil touche the bottom of barbed wire with the help of hog rings (14 SWG) and in between 'Y' shape angle iron post complete all as specified and directed. |
| 11 | Dismantling Plain or corrugated steel sheeting including ridges, hips, and valleys, of any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and directed. |
| 12 | S&F of pre-painted galvalume aluminium zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in room covering/cladding to wall, including ridge cover fixed with self tapping screws etc all as specifed. |
| 13 | S & F Colored Polycarbonate Sheets 6mm thick (multi wall) including aluminium strip size 40x 3mm as in roof covering/ cladding to wall, fixed with self tapping screws as specified. |
| 14 | M & L for providing plain cement concrete type B-0, 1:2:4, (using 12.5 mm graded stone aggregate), as in copings, bed block for embedding hold fasts, kneelers, apex stones, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles & throating as directed including necessary form work as required complete all as specified and directed. |
| 15 | Fromwork to roof slab with projection including edges with rough finished surfaces of concrete complete all as specified and directed. |
| 16 | M & L for providing 25 mm thick pre-cast cement concrete louvers or RCC Jali made out of cement concrete 1:2:4 type B-0, using 12.5 mm graded stone aggregate and set in cement mortar 1:4 including all mouldings etc complete all as specified and directed. |
| 17 | Dismantling of stone slabs and tiles of any description or thickness in floors, platform, aprons etc laid bedded and pointed in any mortar complete all as specified and directed. |
| 18 | M & L for 20 mm thick granite (of any type and colour ) work (table rubbed and polished ) in steps, Jambs, pillars, window cills, cooking platform and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust and admixture of pigment to match with shade of granite complete all as specified and directed. |
| 19 | Rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations |
| 20 | M & L for providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footparth, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 30mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand complete all as specified and directed. |
| 21 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) and rubbish off the premises, all as specified and directed |
| 22 | M&L for Chequered cement concrete tiles 30cm x 30cm x 20-22mm thick, set, jointed and pointed in neat cement slurry with gray cement and pig mentss over 15mm thick screed bed 1:4 , set and jointed in neat cement slurry and pointed in white/coloured cement to match complete all as specifiedin floor, paving, path etc |
| 23 | S&F exterior tiles of superior quility 300x300/400x400x10-12MM thick of approved size/design/shade set and jointed in neat cement slurry & pointed in white or coloured cement to match as in floor over and including 20mm thick screed bed in cm 1:4 complete all as specified and directed. |
| 24 | S&F 75x50mm single rebated factory made 100% solid WPC prelem both side (Wood Polymer Composit) door frame from 100% lead free ( Single & extruded process) material with dencity not less then 780kg /Cum all as specified and directed. |
| 25 | S&F in repairs made of 18mm thick solid WPC density@550kg/cum, designed board with CNC cuttings white color as in view cutter fixed with stapled screw & accessories fittings etc complete all as specified and directed. |
| 26 | M & L for providing pre-cast cement concrete in door or window cills, lintel, bressumers, bed plat, apex stone, pintle blocks, bonders (For stone masonry) and similar items with plain faces including chamfers, weathering, throating etc. in cement concrete 1:2:4 type B-1, using 20 mm graded stone aggregate and setting in cement mortar 1:6 complete all as specified and directed. |
| 27 | Demolition of brick work built in cement mortar including all quoins, arches, pillars etc. complete all as specified and directed. |
| 28 | M&L brick work with fly ash bricks, straight or curved on plan exc 6m mean radius, built in radius built in cement mortar 1:6 all as directed by the Engr-in-Charge. |
| 29 | M & L for preparation of surface of walls and rendering/plaster by using readymix mixture of thickness 12 mm to 15 mm with white cement based polymer modified selfcuring mortar including water proofing compound as per manufacturer's instructions complete all as specified and directed. Note : Cost of WPC shall be deemed inclusive in quoted unit rate. |
| 30 | M & L for preparation of surface of walls and rendering/plaster by using readymix mixture of thickness 12 mm to 15 mm with white cement based polymer modified selfcuring mortar including water proofing compound as per manufacturer's instructions including taking down cement or cement lime plaster from brick or stone walls etc. including raking out joints, hacking for keys, scrubbing down with water etc. including removing of rubbish off the premises complete all as specified and directed. Note : Cost of WPC shall be deemed inclusive in quoted unit rate. |
| 31 | M&L for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces complete all as specified and directed. |
| 32 | M & L for preparation of newly plaster surfaces of wall and applying two coat of cement base paint complete all as specified and directed. |
| 33 | M & L for preparation of old plaster surfaces of wall and applying two coat of cement base paint complete all as specified and directed. |
| 34 | Demolition of Reinforced Cement Concrete works of any description and in any position not otherwise specifically provided . |
| 35 | M & L for providing pre-cast cement concrete landing, cover slabs, chullah hoods, chajjas, shelves and similar items with plain faces in cement concrete 1:2:4 type B-1, using 20 mm graded stone aggregate and setting in cement mortar 1:6 complete all as specified and directed. |
| 36 | M & L for mild steel TMT bars 10 mm dia and over, cut to length, bent to shape required including cranking, bending spirally for hooping for columns and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed. |
| 37 | M&L for reinforced cement concrete 1:11/2:3 (Nominal mix) using 20 mm graded aggregates as in slabs supported on walls, beams, column etc complete all as specified and directed. |
| 38 | Excavation in trenches, n exc 1.5 m wide and n exc 1.5m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sqm on plan and n exc 1.5 m in depth and getting out in soft/loose soil complete all as specified and directed. |
| 39 | M&L for cement concrete type B1 1:2:4 (20mm graded aggregate ) as in surface channels and drains complete all as specified and directed |
| 40 | Extra for forming fair finished drain or channel 60 cm inner girth in cement concrete using extra cement including necessary forms mould mitred /stopped ends etc complete all as specified and directed. |
| 41 | Returning filling in including spreding leveling watering and well ramming in layers not exc 25 Cm in soft/loose soil complete all as specified and directed. |
| 42 | Removal of excavated material n.exc 50 m and depositing where dircted at a level not exc 1.5 mtr above the strating point complete all as specified and directed. Please Enable Macros to View BoQ information |