| 1 | Providing and fixing of 12.5 mtr High mast, 9 mtr Mini High mast, 8 mtr long GI pole in ward no-15 at Zone-1 under limit of Municipal Corporation Gurugram |
| 2 | Supply and erection of 2.5 sqmm 3 core unard FRLS PVC insulated ISI Marked copper conductor cable complete as per entire satisfication of engineer in charge.Make RR / Havells / Polycab/Grandley. 2.5 Sq. mm 3 Core Cable. |
| 3 | Providing trench less boring below existing road / pavement including laying of 65 mm dia GI pipe B class required to complete the job in all respect |
| 4 | Restoring the road cut, in level with the existing road surface, including preparation of subgrade laying and relaying of soiling and laying and consolidation of wearing coats to water bound macadam specification and laying 20mm thick premix carpet, on top including cost of tack and sealcoat complete in all respects... |
| 5 | Providing trench less cuttting by Hydraulic Drilling Device boring/ Manual OR through some suitable alternate method with insertion of HDPE Pipe including supply, Delivery of HDPE pipe at work site and laying of 50mm internal diameter HDPE pipe inside road for road corssing of cable by Hydraulic Drilling Device without opening of the road top surface, laid at a depth of at least 900mm below the road surface from the feeding point to the feeder pillar box in median (OR) from feeder pillar to respective street light pole including cost of all accessories for road crossing for laying of cables.. |
| 6 | Digging of pucca road in required width for laying of cable/pipe complete in all respect upto the entire satisfaction of Engineer-in-charge.. |
| 7 | Supply and Erection of Timer Contractor, DP, MCB mounted on Bakelite sheet and Installed in water proof CRCA Sheet 18 SWG duly painted with powder coated paint Box of Size 12``x15``x5`` duly lockable including Input and Out Put Connectors Bakelite/Porclein of 63A Rating and neccessary service cable up to 10 mtr complete with internal copper wiring and installing the same on pole/pedestal with suitable means at height desired by Engineer in charge to aviod theft upto entire satisfication of engineer incharge with following specification. Timer :-Quartz Analog 24 Hour Operation (G.E/LandT/Siemens/Indoasian/CandS) Contractor :- 3Pole 32A, 415Volt. (Schnider/LandT/Siemens/Indoasian/CandS) DPMCB :- 40A 2pole. (G.E/LandT/Siemens/Schnider/CandS).. |
| 8 | Erection Testing and commissioning of Three phase CCMS panel petty material required for installation of ccms panel i.e clamp,nut and bolts,thimble ,wire etc complete in all material required for installation on PCC pole or Pedstal. complete in all material required for installation on PCC pole or Pedstal. |
| 9 | Providing and fixing of 4G/5G Sim Card and recharse fees per month for street lights CCMS panel Compelte in all respect required for proper operation of CCMS panel. 500 Nos x 60 |
| 10 | Supply and eraction of 9 meter long high mast IS, 2062 E250A single saction 3mm thick sheet GI sheet, top dia 150mm bottom dia 360mm hot dip galvanized thickness of galvanized 70 micron as per IS 2629 opening door at base 900x305mm closed, fitting, door with ALLEN KEY thickness and diameter of base plate 25 mm, 520mm, (O.D) IS 2062 E250A size of anchor plate and thickness 3 mm with uniform PCD of 460mm (IS 2062 E250A, no of arm 6nos. double drum type, permanent oil bath lubrication arrangment, 500kg loading capacity still core , 3 plus 2 nos. ropes , braking capicity load 1750 kg for core PVC insulatted 2.5 squre mm coper wire with 6nos foundation bolts length 850mm dia meter 24mm input supply 3 phase 415 balts and motor required as per capicity and Supply and erection of RCC foundation 1.5.3 of size 0.7 M x 0.7M × 1.8 M with minimum 8 Nos. 12 mm dia longitudinal MS reinforcement rods with rings of 8mm dia not more than 200 mm C.C. for fixing the High Mast with all labour and material required of complete in all respect ( design of high mast, bracket, light fiting as per attached drawing ) |
| 11 | Defect liablity period for Replacement of burnt/faulty cables of various sizes 25 X 4 core and 50x4 core cable, HDPE pipe, felxible wire, MCB, MCCB, Earthing, etc., SPMCB, EPMCB, contractor, wiring and other item required for CCMS panel and Installation of material supplied by the M/s Surya Co. as per rate contract term and Condition i.e SPMCB, EPMCB, contractor, wiring etc and other item required for CCMS panel and maintaining the connectivity of CCMS panel with the GMDA/other portal through sim and removing of fault in ccms panel for 1st and 2nd year free of cost complete in all respect of 3rd year @6% of capital cost |
| 12 | Defect liablity period for Replacement of burnt/faulty cables of various sizes 25 X 4 core and 50x4 core cable, HDPE pipe, felxible wire, MCB, MCCB, Earthing, etc., SPMCB, EPMCB, contractor, wiring and other item required for CCMS panel and Installation of material supplied by the M/s Surya Co. as per rate contract term and Condition i.e SPMCB, EPMCB, contractor, wiring etc and other item required for CCMS panel and maintaining the connectivity of CCMS panel with the GMDA/other portal through sim and removing of fault in ccms panel for 1st and 2nd year free of cost complete in all respect of 4th year @7% of capital cost |
| 13 | Defect liablity period for Replacement of burnt/faulty cables of various sizes 10x3core,e and 25X 4 core cable SPMCB, EPMCB,contractor, wiring and other item required for CCMS panel and Installation of material supplied by the M/s Surya Co. as per rate contract term and Condition i.e SPMCB, EPMCB, contractor, wiring etc and other item required for CCMS panel and maintaining the connectivity of CCMS panel with the GMDA/other portal through sim and removing of fault in ccmspanel for 1st and 2nd year free of cost |
| 14 | Supply and erection of Sword type single Arm GI bracket with Big Ball on top and small Ball Complete in all respect including nut and bolts required for installation with suitable size of GI pole. . |
| 15 | Providing and fixing of 12.5 mtr High mast, 9 mtr Mini High mast, 8 mtr long GI pole in ward no-15 at Zone-1 under limit of Municipal Corporation Gurugram Please Enable Macros to View BoQ information |