|
| 1 | Dismantling the existing tar (BT) road surface - Mechanical Means |
| 2 | Removing the Existing Paverblock M40 grade 80mm thick & 60mm thick in the rate including Removing and Stock to the Same Site and tranporting loading unloading and Labour Charges and Other tools etc.complete as per standard specification,. |
| 3 | Dismantling RCC by manual / by using deploying machineries (Drains) |
| 4 | Earth work excavation for foundation in Hard stiff clay, stiff black cotton, hard red earth, shales murram, gravel,stoney earth and earth mixed with small size boulders SS.20B and Sand, silt or other loose soil, wet sand,or silt not under water, light black cotton soil, sandy loam ordinary soil and to full depth as may be directed except in hardrock requiring blasting inclusive of shoring shuttering and baling out water and cleaning and levelling the site etc.,complete - Depth 0 to 2 m |
| 5 | Earth work excavation for foundation in Hard stiff clay, stiff black cotton, hard red earth, shales murram, gravel,stoney earth and earth mixed with small size boulders SS.20B and Sand, silt or other loose soil, wet sand,or silt not under water, light black cotton soil, sandy loam ordinary soil and to full depth as may be directed except in hardrock requiring blasting inclusive of shoring shuttering and baling out water and cleaning and levelling the site etc.,complete - 2 to 3 m Depth |
| 6 | Earth work excavation for foundation in Hard stiff clay, stiff black cotton, hard red earth, shales murram, gravel,stoney earth and earth mixed with small size boulders SS.20B and Sand, silt or other loose soil, wet sand,or silt not under water, light black cotton soil, sandy loam ordinary soil and to full depth as may be directed except in hardrock requiring blasting inclusive of shoring shuttering and baling out water and cleaning and levelling the site etc.,complete - 3 to 4 m Depth |
| 7 | Earth work excavation for foundation in Hard stiff clay, stiff black cotton, hard red earth, shales murram, gravel,stoney earth and earth mixed with small size boulders SS.20B and Sand, silt or other loose soil, wet sand,or silt not under water, light black cotton soil, sandy loam ordinary soil and to full depth as may be directed except in hardrock requiring blasting inclusive of shoring shuttering and baling out water and cleaning and levelling the site etc.,complete - 4 to 5 m Depth |
| 8 | Earth work excavation for foundation in Hard stiff clay, stiff black cotton, hard red earth, shales murram, gravel,stoney earth and earth mixed with small size boulders SS.20B and Sand, silt or other loose soil, wet sand,or silt not under water, light black cotton soil, sandy loam ordinary soil and to full depth as may be directed except in hardrock requiring blasting inclusive of shoring shuttering and baling out water and cleaning and levelling the site etc.,complete - 5 to 6 m Depth |
| 9 | Earth work excavation for foundation in Hard stiff clay, stiff black cotton, hard red earth, shales murram, gravel,stoney earth and earth mixed with small size boulders SS.20B and Sand, silt or other loose soil, wet sand,or silt not under water, light black cotton soil, sandy loam ordinary soil and to full depth as may be directed except in hardrock requiring blasting inclusive of shoring shuttering and baling out water and cleaning and levelling the site etc.,complete - 6 to 7 m Depth |
| 10 | Shoring, and strutting with sheet piles of size width 400 mm x height of 3m x thickness of 9mm as per IS 2314-1986 by driving on both sides of the trench from Ground Level up to the required depth and connecting the above sheet piles by horizontal strutting with sheet piles at an interval of 1.0m, fixing the sheet piles by connecting the horizontal strutting with casurina poles of 8cm to 10cm dia. at 1.50m interval and including removing the sheet piles after the pipelines are laid, jointed, tested, and stacking it safely for other uses. It includes the cost of sheet piles and casurina poles including labour charges for erecting the sheet piles, driving the sheet piles, removing the sheet piles, fixing Casurina poles, etc., complete and all other incidental charges for the depths - 0 to 3 m |
| 11 | Hire Charges for Dewatering using 3HP to 70HP diesel engine pumpset including Hire charges, cost of Diesel, Engine oil, pump operator, labour charges, conveyance of pumpset and fuel to site and back, loading, unloading and any other incidental charges etc., complete |
| 12 | Supplying and filling in foundation and basement with Crushed Stone Sand (M- Sand) in layers of not more than 15cm thick well rammed watered and compacted etc., complete complying with standard specification. |
| 13 | Plain Cement Concrete 1:3:6 (one cement, three crushed Stone Sand (M- Sand) and six coarse aggregates) using 20mm size ISS HBG metal including cost and conveyance of all materials to site and including for the mixing, laying and labour charges etc., complete as per standard specification |
| 14 | Plain Cement Concrete 1:2:4 (one cement, two Crushed Stone Sand (M- Sand) and four coarse aggregates) using 20mm size ISS HBG metal including cost and conveyance of all materials to site and including for the mixing, laying and labour charges etc., complete as per standard specification - @ Pipe Encasing at Subway Passing |
| 15 | Rough stone Dry Packing for Aprons and revetments using rough stones and the cost shall inclusive all materials and labour charges etc complete- 1cum S.I. 217 |
| 16 | Supplying, erecting shuttering with necessary supports for plinth beam with all cross bracing etc., complete ( RCC column footing plinth, beam and lintel sides ) - Below 1m for Thrust Blocks & PCC Encasing |
| 17 | Supplying, erecting shuttering with necessary supports for drains with all cross bracing etc., complete ( RCC Bottom Slab,Side Walls & Top Slab ) - Above 1m |
| 18 | Centering for soffits of RCC slabs of plane surface like lintels, beams ,etc.,including strutting 3m high using mild steel sheets of size 90cm X 60cm X and B.G 10 stiffened with M.S angles of size 25mm X 25mm X 3mm laid over silver Oak (C.W) joists of size 10cm X 6.5cm (spaced at about 90cm c/c )and supported dy casurina props of 10cm to 13cm dia (spaced of 75cm C/C) complying with standard specification and directed - 10 m 2 (P & D)Data 38-For Bottom Raft, Columns,Beams,Side walls & Slabs |
| 19 | Providing and laying in position Standardized Concrete Mix M-25 Grade in accordance with IS 456-2000 using 20mm and downgraded hard broken granite stone jelly for all RCC of works with minimum cement concrete 0f 350 kg/m3 and maximum water cement ratio of 0.55 including admixture ( Plaster / super plasticizer ) in recommended proportions as per IS : 9103 to accelerate, retard setting of concrete improve workability without imagining strength and durability with about (5.0cu.m) 7730 kg of 20mm machine crushed stone jelly and with about (3.3 cum) 5156 kg of 10-12mm machine crushed stone jelly and with about (4.79 cum) 7670 kg of sand, but excluding cost of reinforcement grill and fabricating charges centering and shuttering and also including laying vibrating with mechanical vibrators finishing curing etc. and providing fixtures like fan clamps in the RCC floor / roof slabs wherever necessary without claiming extra, etc,. Complete complying with standard specification and as directed by the departmental officers the coarse and fine aggregates to be used should comply with the requirements of IS Standards. (No separate payment will be made by the Department for the excess usage of materials). - For Proposed Drains Bottom Slab,Side Wall and Top Slab |
| 20 | Providing and laying in position Standardized Concrete Mix M-30 Grade in accordance with IS 456-2000 using 20mm and downgraded hard broken granite stone jelly for all RCC of works with minimum cement concrete 0f 400 kg/m3 and maximum water cement ratio of 0.45 including admixture ( Plaster / super plasticizer ) in recommended proportions as per IS : 9103 to accelerate, retard setting of concrete improve workability without imagining strength and durability with about (5.0cu.m) 7730 kg of 20mm machine crushed stone jelly and with about (3.3 cum) 5156 kg of 10-12mm machine crushed stone jelly and with about (4.79 cum) 7670 kg of sand, but excluding cost of reinforcement grill and fabricating charges centering and shuttering and also including laying vibrating with mechanical vibrators finishing curing etc. and providing fixtures like fan clamps in the RCC floor / roof slabs wherever necessary without claiming extra, etc,. Complete complying with standard specification and as directed by the departmental officers the coarse and fine aggregates to be used should comply with the requirements of IS Standards. (No separate payment will be made by the Department for the excess usage of materials).-Drainage Pumping Station Bottom Raft,Beams,Side Walls and Roof Slab |
| 21 | Erection & Installation of Precast/Prestressed Concrete elements in correct & final position with proper line level and plumb at site making all arrangements (i.e cranes, push-pull jacks & all another Tools & Plants for lifting Placing & alignment of elements, within erection tolerance as per IS 15916 as per approved shop drawings and all complete as per the direction of Engineer-in-Charge but excluding the cost of sim pads, non shrink grout and steel works i.e hangers. - Precast Slabs on DPS |
| 22 | Restoring the tar road surface by spreading Sand filling, filling gravel and WMM over a layer of 30 cm thick gravel and providing premix carpet with seal coat type 'A' including cost of all materials etc. complete 10m2 |
| 23 | Restoring the Cement Concrete road of cutting the cement concrete road, Sand filling 10cm thick, C.C 1:5:10, C.C 1:2:4 10cm thick Plastering 1:3 20mm thick at tarpad of expension joint using etc., including cost of all materials etc. complete 10m2 |
| 24 | Suppling and fabricating and placing in position MS (or) R.T.S. bar for reinforcement to all RCC works as per the design given including cost of steel and binding wire also in all floors. |
| 25 | Providing weep holes in Brick masonry/Plain/Reinforced concrete wall/return wall with 100 mm dia PVC pipe, extending through the full width of the structure with slope of 1V :20H towards drawing face. Complete as per drawing and Technical specifications |
| 26 | Laying of a geotextile (200 GSM) filter between pitching and embankment slopes on which pitching is laid to prevent escape of the embankment material through the voids of the stone pitching/cement concrete blocks as well as to allow free movement of water without creating any uplift head on the pitching as per Tech Specifications in Section 700 & 2504 MORTH |
| 27 | Providing and laying filter media with granular crushed aggregates as per specification to a thickness of not less than 600 mm with smaller size towards the soil and bigger size towards the wall and providing over the entire surface behind abutment, wing wall, return wall to the full height, compacted to firm condition complete as per drawing and technical specification Clause 1204.3.8 MORD / 710.14 of IRC, 78 & 2200 MORTH |
| 28 | Refilling with excavated soil (other than sand) complying with the standard specification for filling in foundation and basement |
| 29 | Disposal of surplus earth including loading and conveyance within a distance of 5 km (basic cost of earth is zero) including loading charges and Conveyance Charges of 5 kms distance. |
| 30 | Providing and fixing Bitumen Pad for Expansion joint in between pavement slabs to 12mm thick and fixed as shown in the drawing including cost and conveyence of expansion joints including shalimar pad and joint sealent etc, complete as per standard specification |
| 31 | Providing Iron Barricading of size 2.50 m width and 1.75 m height using 40x40x4 mm angle for outer frame supports, 25 x 25 x 3 mm angle for inner frame supports and 20 gauge thickness MS sheet for name board (as per drawing) including cutting, welding, fabrication charges and one coat of primer and 2 coats of enamel paint of approved quality work detail/ caution sign, providing necessary interlocking arrangements with adjoining units, fixing danger flags, danger lights, reflectors, fixing stickers etc, including watching during night and placing the barricading units as directed at the sites |
| 32 | Towards the hire charges for providing temporary approach platforms to the residences near execution site including the cost of fabrication, placing properly across the drains removing the same after the work is complete etc as directed by Engineer in charge. The approach platform will be made of 2.40mx1.20m - 6mm MS sheet fabricated with 50mm dia B-class MS pipe-3.6m at bottom longitudinal and 3 Nos MS flat 25mmx6mm cross direction and both side of hand rail with 50mm dia 1 No of horizontal and 2 Nos of Vertical support including fixing MS flat drilled and suitable for joining with bolts and nuts including cost of materials, welding, painting etc complete |
| 33 | Construction of Modular type RWH Structure capacity of 4.32 cu.m by using infiltration modules of size 800 x 800 x 360 mm and side wall with infiltration modules of size 800 x 360 x 25 mm including earthwork excavation in bitumen / concrete roads surface to a size of 1200 x 1200 x 3000 mm and providing base plate, Geo - textile 400mm - 200 micron, Fine filter media 12mm thickness, Coarse filter media 20mm thickness, FRP of 700x700mm (clear opening 600x600mm) (Grating cover with Frame-Medium duty 10MT), including all labour charges, carting away and drilling borewell 150mm dia upto a depth of 3.0m with 125mm dia Blue slotted PVC pipe., complete.(Model 6) |
| 34 | Construction of cast -in- situ Silt Catch Pit of inner size 600 X 600 x 600 mm including necessary earth work excavation including providing foundation in PCC 1:4:8 under walls 150mm thick and cutting the existing storm water drain of size 300 x 150mm for fixing 2 Nos of 160mm dia PVC pipe on the storm water drain mouth, with RCC cast in situ wall of size 120mm in RCC 1:1.5:3 with steel of 16.41 kg including Supply fixing Ductile Iron Grating with frame load bearing capacity 25MT grade C-250,Heavy Duty as per BS EN 124 standard weight of the cover with frame is 54kgs ( Hinged type), Frame outer 725mm x 725mm, Height 75mm - completing the finishing work etc., cost per each number. |
| 35 | Supplying, fabricating, erecting structural steel work for roofing welded or bolted type using MS channels, angles, plates and round bars etc. conforming to IS specification including primer coating and enamal painting as per Design given by the departmental officers etc, complete as per standard specification - Gratings for Drain & L angle and Trash Rack for DPS |
| 36 | Manufacture, Supply, Delivery and Installation of Automatically Worked S.S 304 Flap Gate, Wall Mounted, single faced, flush bottom closing type Material Construction : Gate Frame SS 304, Shutter/Door SS 304,Seating Faces EPDM Rubber,Hinge Pin SS 304 excluding taxes etc., complete finished item of work (Approved Make) - Size :- 1500 x 1500 mm |
| 37 | Earth work deploying earth moving machinery for desilting channel and forming bund on either side and depositing the earth on banks including jungle clearance etc complete.Desilting of Storm water Drains - For Existing Drains (having width up to 3m) |
| 38 | Earth work deploying earth moving machinery for desilting channel and forming bund on either side and depositing the earth on banks including jungle clearance etc complete.Desilting of Storm water Drains - For Thepakulam Pond Network (having width of 3m -10m) & For Kirdumal Channel (having width of 3m -10m) |
| 39 | Manufacture,Supply & Fixing of 900mm x 900mm Ductile Iron manhole cover with frame load bearing capacity 1.5 MT grade A-15 Light Duty as per BS EN 124 standard weight of the cover with frame is 95 KG ( Hinged type) MS 26, Frame outer 1020 x 1020, Height 50 mm etc., complete and as directed by the departmental officers. |
| 40 | Manufacture,Supply & Fixing of 900mm x 900mm Ductile Iron manhole cover with frame load bearing capacity 40MT grade D-400 Extra Heavy Duty as per BS EN 124 standard weight of the cover with frame is 170 KG ( Hinged type) MS 29, Frame outer 1065 x 1065, Height 100 mm etc., complete and as directed by the departmental officers. |
| 41 | Plastering with cement mortar 1:3, 12 mm ,thick in all floors mixed with Water Proofing Compound including cost and conveyance of all materilas to site and labour charges etc,complete as per standard specifications (S.I.306) - Sump inside |
| 42 | Manufacture as per company’s standard specification supply and delivery of PVC mould CI Steps for Sump including cost of materials packing as per company’s standards, loading, transportation, unloading and stacking at site of work etc, complete but excluding all taxes. |
| 43 | Supply and delivery of Ductile Iron Class PN10 Flanged pipes as per IS 8329/2000 including transportation charges to stockyard excluding unloading anywhere in Tamilnadu. - 300 mm Dia - 4.0 m Length |
| 44 | Supply and delivery of Ductile Iron Class PN10 Flanged pipes as per IS 8329/2000 including transportation charges to stockyard excluding unloading anywhere in Tamilnadu. - 300 mm Dia - 1.0 m Length |
| 45 | Ductile Iron Socket/Spigot Pipes For Class K9 As Per Is 8329/2000 including loading,unloading and transportation charges anywhere in Tamilnadu. - 600 mm |
| 46 | Ductile Iron Socket/Spigot Pipes For Class K9 As Per Is 8329/2000 including loading,unloading and transportation charges anywhere in Tamilnadu. - 700 mm for Encasing |
| 47 | Supply and delivery of Ductile Iron Specials as per as per IS 9523/2000 including transportation charges anywhere in Tamilnadu. - TEEs 600 x 300 mm |
| 48 | Supply and delivery of Ductile Iron Specials as per as per IS 9523/2000 including transportation charges anywhere in Tamilnadu. - Bend 11.25° - 600 mm dia Socket |
| 49 | Supply and delivery of Ductile Iron Specials as per as per IS 9523/2000 including transportation charges anywhere in Tamilnadu. - TEEs 600 x 600 mm |
| 50 | Supply and delivery of Ductile Iron Specials as per as per IS 9523/2000 including transportation charges anywhere in Tamilnadu. - Bend 90° - 300 mm dia |
| 51 | Supply and delivery of Ductile Iron Specials as per as per IS 9523/2000 including transportation charges anywhere in Tamilnadu. - Bend 90° - 600 mm dia , All Flanged |
| 52 | Supply and delivery of Ductile Iron Specials as per as per IS 9523/2000 including transportation charges anywhere in Tamilnadu. - Bend 90° - 600 mm dia , All Socket |
| 53 | Supply and delivery of Ductile Iron Specials as per as per IS 9523/2000 including transportation charges anywhere in Tamilnadu. - Flanged to Spigot / Socket - 600mm |
| 54 | Supply and delivery of Ductile Iron Specials as per as per IS 9523/2000 including transportation charges anywhere in Tamilnadu. - Flanged Bend 90° - 600 mm Dia |
| 55 | Supply and delivery of Ductile Iron Specials as per as per IS 9523/2000 including transportation charges anywhere in Tamilnadu. - DI End Caps - 600 mm Dia |
| 56 | Supply and delivery of Ductile Iron Specials as per as per IS 9523/2000 including transportation charges anywhere in Tamilnadu. - Dismantling Joints - 300mm Dia |
| 57 | Supply and delivery of Ductile Iron Specials as per as per IS 9523/2000 including transportation charges anywhere in Tamilnadu. - Dismantling Joints - 600mm Dia |
| 58 | CI Sluice Valves Non Raising Spindle Types To Pressure Rating Of 1.6 Pn To Be Used In Pump Houses (Long Body/ Long Face To Face) Conforming To Is And With 5 Years Warranty including transportation charges anywhere in Tamilnadu. - 300 mm |
| 59 | Non Return Valves Double Flanged (Dual Plate Check Valve) Conforming to IS and With 5 Years Warranty including transportation charges anywhere in Tamilnadu. - 300 mm |
| 60 | Lowering of D.I Pipes and specials in the trenches and laying to proper grade andalignment and as directed by the TWAD Officers. - 300 mm |
| 61 | Lowering of D.I Pipes and specials in the trenches and laying to proper grade and alignment and as directed by the TWAD Officers. - 600 mm |
| 62 | Lowering of D.I Pipes and specials in the trenches and laying to proper grade and alignment and as directed by the TWAD Officers. - 700 mm For Encasing |
| 63 | Jointing the C.I/ D.I Double flanged pipes and specials with rubber insertion to with IS-638(1979) and M.S. bolts and nuts of IS 1364-1 (2002), including cost of jointing materialssuch as bolt and nuts Rubber insertion andlabour charges etc., complete. - 300 mm |
| 64 | Jointing the C.I/ D.I Double flanged pipes and specials with rubber insertion to with IS-638(1979) and M.S. bolts and nuts of IS 1364-1 (2002), including cost of jointing materialssuch as bolt and nuts Rubber insertion andlabour charges etc., complete. - 600 mm |
| 65 | Jointing C.I/ D.I-S/S pipes and specials with rubber gaskets (tyton joint) including cost of lubricants. (including cost of jointing materials ) - 600mm |
| 66 | Supply, installation, testing and commissioning of Heavy Duty Submersible LT Pumpset with Non Clog Impeller, 415 V 50Hz (+/-3%) , 3φ Phase AC, liquid Submergence (Compling to IC4A1W0 of IS 6362) (NJ.) installed in Sump with vertical orientation,Autocoupling with Integral Bend(With Autocoupling PIN)+ Foundation bolt - 45KW Flow 0.265 Cum/s @ 10 m Head, |
| 67 | 11 kV Four Pole Structure Assembly:SITC of 11 kV double pole 12 meter high structure made of 6\\" X 3\\" 'I\\" section girder, 4\\" X 2\\" channels, clamps, nuts, bolts, stay wires including earthing system with following accessories duly connected with ACSR conductors as per approved drawing & in compliance with requirement of IEC.(a) 11 kV, 200 A drop out fuses with Synthetic Resin Bonded Paper (SRBP) tubes: 2 Set (01 piece per phase / circuit).(b) 11 kV, 400 A G.O.D. switch complete with earth switch, insulators, operating handle with galvanised pipe, square bar: 2 Set.(c) 11 kV lightning arrestor with clamps: 3 Nos.(d) 11 kV Disc Insulators (70KN): 9 Nos. (e) 11 kV Pin Insulators (5KN): 6 Nos. (f) 20 mm dia. GI. Stay Set Complete: 2 Set - 11 kV Four Pole Structure Assembly |
| 68 | SITC of outdoor type, three phase, oil immersed, distribution transformer of copper double wound, vector group - Dyn11, HV delta connected & LV star connected with neutral brought out connected to provide separate earthing terminals, bushing / cable box on HV side and cable box on LV side suitable for cables or bus duct as per requirement with standard fittings, conforming to IS: 1180 (Part-1) / 2014 with its latest amendment including first fill of transformer oil & following accessories.(a) Oil conservator with filling holes with cap and prismatic oil level gauge.(b) Silica Gel dehydrating breather charged with silica gel(c) Oil drain cum sampling valve with plug(d) Oil filter valve(e) Lifting Eyes / Hooks / Lugs(f) Two earthing terminal(g) Diagram and rating plate(h) Air release plug(i) Explosion vent with diaphragm(j) Thermometer pocket(k) Four bi-directional plain roller with base channel with hauling holes(l) Fixed / Separate type radiator banks(m) Off circuit externally operated tapping switch (For rating < 1000 kVA)(n) 100 mm stem type oil temperature indicator (For rating < 500 kVA)(o) Bucholtz relay with shut off valve (For rating ≥ 500 KVA)(p) 150 mm dial type oil temperature indicator with Alarm / Trip contact (For rating ≥ 500 kVA)(q) 150 mm dial type winding temperature indicator with Alarm / Tip contact (For rating ≥ 1000 kVA)(r) Marshalling box (For rating ≥ 500 kVA)(s) 150 mm dia. magnetic type oil gauge (For rating ≥ 1600 kVA)(t) Inspection cover & Jacking lugs (For rating ≥ 1600 kVA)For transformer having oil storage capacity for 2000 liters and higher, nitrogen injection fire protection system (NIFPS) is to be providedmaximum totoal Loses 2.14 kW at 50% of load 5.83 Kw at 100% load,Impedence 5.0 - 11/0.415,400 KVA Transformer, Efficieny level -1 |
| 69 | Accessories for Plinth Mounted Transformer such as HT & LT Cable Entry Boxes, Copper Extension for Cable End Termination for HT & LT sides, Bucholz Relay, Marshaling Box, Wheels, Channels etc., for 400 KVA |
| 70 | SITC of LV MCC Panel totally enclosed, dust & bermin proof, indoor type, minimum degree of protection - IP 52 as per IS: 2147, operation on 3-Phase, 4 Wire, 415V, 50Hz, Neutral effectively grounded, with instrumentation compartments accomodating LED type indicating lamps, control contactors as per IS: 13947, CT of accuracy class- I as per IS: 2705, relays, meters & control MCBs, air insulated electrolitic grade Aluminum bus bar for three phase & neutral system with incomming breaker- microprocessor base MCCB with trip free mechanism, current limiting type as per IS: 8828, momentary contact type push buttons, equipment fittings, bus bars, cable boxes, cable gland, incoming & ougoing cable connection for 1100V grade, Aluminium/ Copper conductor XLPE / PVC insulated & PVC sheathed armoured cable, 10% spare terminals, power wiring using 1100V grade, FRLS insulated copper conductor wires conforming to IS: 694 & 8130, cable compartments / alleys of minimum 300 mm size, GI / Al earth bus bar for entire length. MCC shall be fabricated from cold rolled, coled annealed (CRCA) sheet steel & minimum thickness of various members shall be as follows:Base Frame / Channel / Gland Plate: 3 mm, Load Bearing Members / Doors: 2 mm and Internal Partitions: 1.6 mm and 4 No's of 63A / 60A ,4 Pole MCCB, one No of 315 A 4 Pole MCCB outcomers for LT aux panel |
| 71 | Control Panel (Each) Indoor Panel (Standard) for Pump |
| 72 | Supply installation testing and commissioning of 3 phase and neutral 415V free standing floor mounted indoor LT panel made out of No.16 gauge CRCA sheet steel after 7 tank process and painting with powder coating. The panel shall consists of suitable rating TPN Alluminium busbar, 200A 4 Pole, 36kA MCCB, Cu bus bar, 6 No's 63A / 60A 4 Pole MCCB, 6 no's of 16 A Single pole MCB, 6 Np's of 6A Single pole MCB igital meter,CT Digital Ammeter,Analog selector,Analog LED indicator lamps, Analog LT current transformer,Capacitor bank |
| 73 | Supply, laying in RCC trench, jointing, testing, commissioning of 11kV, U/G XLPE Aluminium conductor 3C X 95 Sqmm, confirming to relevant & latest IEC, Indian standards and State electricity regulations. The work shall be inclusive of suply ,instalation ,testing commisioning of all accessories required for laying of 11kV cable as end termination kits, straight through joint kits (suitable for 3C X 300 Sqmm aluminium cables) as per the site condition, the cable length should be variesCABLES-11kV, 3C X185 Sqmm, XLPE, Aluminium conductor Armored cables |
| 74 | CABLE TERMINATIONS-Heat shrinkable end termination kit (indoor type) for 11kV, 3C X 240 Sqmm, XLPE, Aluminium conductor Armored cables |
| 75 | Supply, laying in RCC trench/Cable tray/Pipe, jointing, testing, commissioning of 415V, XLPE Aluminium / Copper conductor , confirming to relevant & latest IEC, Indian standards and State electricity regulations. The work shall be inclusive of supply ,installation ,testing commisioning of all accessories required for laying of 415 kV cable as end termination kits, straight through joint kits as per the site condition, the cable length should be variesCABLES-415V, 3.5C X 400 Sqmm, XLPE, Aluminium conductor Armored cables |
| 76 | 415V, 3.5C X 70 Sqmm, XLPE, Aluminium conductor Armored cables |
| 77 | 415V, 4C X 10 Sqmm, XLPE, Copper conductor Armored cables |
| 78 | CABLE TERMINATIONS-Cable Gland suitable for 3.5 core 400 sq.mm. UG Cable |
| 79 | Cable Gland suitable for 3.5 core 70 sq.mm. UG Cable |
| 80 | Cable Gland suitable for 2 core 10 sq.mm. UG Cable |
| 81 | Supply & laying GI ladder type cable tray Hot Dip16 SWG Cable Tray with 150mm width and 50mm height - 150(W) x 50(H) |
| 82 | Supply & laying GI ladder type cable tray Hot Dip16 SWG Cable Tray with 150mm width and 50mm height - 300(W) x 50(H) |
| 83 | Automatic Power Factor Capacitor Panel 150 KVAR |
| 84 | Wiring with 2x1.5 sq.mm. PVC insulated single core unsheathed FRLS copper conductor cable of 1100V grade in suitable heavy gauge MS conduit pipe on wall and ceiling with MS accessories with MS switch Box and 5A FT switch with painting of suitable colour continuous earthwire connection of 1.5sq.mmcopperwire for light point / fan point (for electronic regulator) |
| 85 | Wiring with 2x1.5 sq.mm. PVC insulated SC unsheathed FRLS copper conductor cable of 1100V grade in suitable heavy gauge MS conduit pipe on wall and ceiling with MS accessories with switch box with 5A FT switch in flush with wall and covered with hylum sheet of 3mm thick with painting of suitable colour with continuous earthwire connection of 1.5 sq.mm copper wire for light point / fan point (for electronic regulator) |
| 86 | Wiring with 2x4 sq.mm. PVC insulated SC unsheathed FRLS copper cable conductor cable of 1100V grade in suitable heavy gauge MS conduit pipe on wall and ceiling with MS accessories with 150mmx100mmx75mm MS switch box for 15A 3 pin non interlocking CS plug with painting of suitable colour with continuous earthwire connection by 4 sq.mm copper wire for open power plug point |
| 87 | Wiring with 2x1.5 sq.mm. PVC insulated Sc unsheathed FRLS copper conductor of 1100V grade in suitable PVC rigid pipe on wall and ceiling with PVC accessories and with TW switch box and 5A FT switch with painting of suitable colour for open PVC light point / fan point (for electronic regulator) (4 points per coil) |
| 88 | Wiring with 2x1.5 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100V grade in suitable PVC rigid pipe on wall and ceiling with PVC accessories and with TW switch box and 5A Ft switch with painting of suitable colour for open PVC light point / fan point (for electronic regulator) (5 points per coil) |
| 89 | Supply and run of 1 of No.8 SWG GI wire for earth connection |
| 90 | Supply and run of 25mmx3mm tinned copper flat with necessary clamps / supports on wall / floor / ground for earth connection |
| 91 | Supply and fixing of fancy glass shade and 15 W LED Bulb |
| 92 | Supply and fixing of single box type 4'40 W fluorescent fitting complete with copper choke and condensor with TW round blocks on wall or ceiling with flu tube with PVC unsheathed FRLS copper leads from terminals to the fitting |
| 93 | Supply and fixing of 1200mm (48\\") sweep AC ceiling fan complete with stepped electronic 300W regulator with 1metre down rod with fan clamp with side plates and cross arm of size 450mm (18\\") |
| 94 | Supply and fixing of 375mm (15\\") sweep (light duty) AC exhaust fan complete without provision of holes in the wall |
| 95 | Supply and fixing of 5A/15A 3 pin combined flush type wall socket with 15A flush type switch concealed in suitable MS box flush with wall with painting |
| 96 | Earthing as per the ISI specification with an earth electrode of 2.10 metre Class 'B' GI pipe of dia not less than 40mm with copper earth plate of size 125mmx50mmx6mm with necessary funneling arrangements with necessary masonry work and with 38mm RCC cover slab for the brick masonry |
| 97 | Supply and fixing of 4'40W twin street light fluorescent fitting complete with copper choke and condensor with 19mm dia GI pipe (Class 'B') with 1No. 19Mm GI bend complete on the existing post / wall with 16A aerial fuse unit on MS plate with PVC unsheathed FRLS copper leads with MS clamps and aluminium painting with fluorescent tubes |
| 98 | Lightning Arrestor Station type 9KV/11KV |
| 99 | 2KVA, 230 V single phase UPS System with One hour inbuilt battery backup |
| 100 | Diesel Generator Set with acoustic enclosure conforming to CPCB IV+ Norms and BIS Specifications With AMF Panel 320 KVA |
| 101 | ESHS Capacity Building, Stakeholder Engagement, Monitoring & Health (Lump Sum, inclusive of all mobilization, instruments, NABL-accredited testing, consumables, travel, permits, reporting and taxes) — Execute and document the following per ESMP/ESHS & CPCB/TNPCB/MoHFW norms, with geo-tagged photos, calibration/chain-of-custody and quarterly compiled reports:Workshop on E&S safeguards and on-job training as identified. (one time) |
| 102 | Consultations / GRC |
| 103 | Air quality monitoring (3 locations) quarterly |
| 104 | Surface water quality monitoring (2 locations) quarterly |
| 105 | Ground water quality monitoring(2 locations) quarterly |
| 106 | Soil quality monitoring(2 locations) quarterly |
| 107 | Noise quality monitoring(3 locations) quarterly |
| 108 | Wind speed and direction(3 locations) quarterly |
| 109 | Health camp, occupational health and prevention of Covid 19 |
| 110 | GST 18% Please Enable Macros to View BoQ information |