| 1 | INSULATORS |
| 2 | Supplying and erection of galvanised ‘D’ iron clamps complete with shackle insulator (75 mm X 90 mm), G.I bolts, nuts and washers, coach screws etc. as required for LT lines. |
| 3 | Supplying and erection of 100 mm X 80 mm pin insulator complete with G. I. Spindle and nuts etc. as required for LT lines. |
| 4 | Supplying and erection of 11 KV pin insulator complete with large steel head G.I. pin, nuts, washers etc. as required. |
| 5 | Supplying and erection of 33 KV pin insulator complete with large steel head G.I. pin, nuts, washers etc. as required. |
| 6 | Supplying and erection of 11 KV disc insulator with galvanised insulator fittings, ball and socket type and complete with galvanised strain clamps, bolts, nuts, washers etc. as required. |
| 7 | Supplying and erection of a set of three 11 KV disc insulator for 33 KV over head lines with galvanised insulator fittings, ball and socket type and complete with galvanised strain clamps, bolts, nuts, washers etc. as required. |
| 8 | LIGHTNING ARRESTOR |
| 9 | Supplying and erection of three piece nonlinear resistor type lightning arrestor suitable for 3 wire, 11 KV overhead lines with rated voltage 9 KV (rms) with a nominal discharge current rating of 5 KA and complete with galvanised clamping arrangement, G.I. bolts, nuts, washers etc. as required. |
| 10 | Supplying and erection of single piece nonlinear resistor type lightning arrestor suitable for 3 wire, 33 KV overhead lines with rated voltage 30 KV (rms) with a nominal discharge current rating of 10 KA (station class) and complete with galvanised clamping arrangement, G.I. bolts, nuts, washers etc. as required. |
| 11 | Providing and fixing of lightning conductor finial, made of 25mm dia 300 mm long, G.I. tube, having single prong at top, with 85mm dia 6 mm thick G.I. base plate including holes etc.complete as required. |
| 12 | FUSES |
| 13 | Supply and erection of 200A horn gap fuse set with post insulators suitable for 3 wire, 11 KV overhead lines. |
| 14 | Supply and erection of horn gap fuse set with post insulators suitable for 3 wire, 33 KV overhead lines. |
| 15 | Supply and erection of drop out fuse set suitable for 3 wire, 11 KV overhead lines. |
| 16 | Supply and erection of drop out fuse set suitable for 3 wire, 33 KV overhead lines. |
| 17 | Providing of 11Kv DO Operating Rod (FRP) with min. 18 ft length |
| 18 | Providing of 33Kv DO Operating Rod (FRP) with min. 18 ft length |
| 19 | Providing and fitting of fuse element of required current rating for DO Fuse. |
| 20 | Providing of requisite tinned copper fuse wire |
| 21 | SWITCHES |
| 22 | Providing and fitting of 11 KV 200A 3-ph Gang operated Air Break Switch complete with operating mechanism |
| 23 | Providing and fitting of 33 KV 400A 3-ph Gang operated Air Break Switch |
| 24 | Providing and fitting of following Air Break switch accessories |
| 25 | Providing and fixing of Air Break Switch Handle |
| 26 | Providing and fixing of 'DANGER' plate of standard size for 440V/ 11KV/ 33KV. |
| 27 | EARTHING |
| 28 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and 20mm GI (medium class) watering pipe 2.7 meter long, funnel etc. with charcoal/ coke and salt as required. |
| 29 | Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required. |
| 30 | Supplying and laying 25mm X 5mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. |
| 31 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required. |
| 32 | Providing and fixing 25 mm X 5 mm G.I strip on surface or in recess with GI saddles and allied fittings for connections etc. as required. |
| 33 | TRANSFORMERDismantling of 33/0.4 kv or 11/0.4 kv transformer by way of disconnecting of all HT & LT connections, opening of top lid, draining out of T.oil and its safe placement for further refilling, taking out of coils after removal of core assembly, etc. job also includes detaching of core HV/LV coils. |
| 34 | Upto 50 kva |
| 35 | > 50 kva upto 100 kva |
| 36 | > 100 kva upto 250 kva |
| 37 | Greater than 250 kva upto 630 kva |
| 38 | Complete assembling of 33/0.4 kv or 11/0.4 kv transformer after cleaning of tank, fitting of coil assembly in the tank. Job furtheer includes closing of the transformer lid by way of fitting of existing nuts/bolts and gaskets, insulators, etc. Refilling of T.oil upto required level in tank. Reconnecting of HT/LT connections and testing. |
| 39 | Upto 50 kva |
| 40 | > 50 kva upto 100 kva |
| 41 | > 100 kva upto 250 kva |
| 42 | Greater than 250 kva upto 630 kva |
| 43 | Providing new CRGO lamination to the core in place of damaged core wherever necessary including cost of materials and labour |
| 44 | Providing and fitting of finished new electrolytic grade copper wire windings with insulation in place of damaged windings including allied costs such as varnish (Becks or any other reputed make), drying etc. (Both HV & LV) per Kg of winding. |
| 45 | Providing and fitting of finished new electrolytic grade copper strip windings with insulation in place of damaged windings including allied costs such as varnish (Becks or any other reputed make), drying etc. (Both HV & LV) per Kg of winding. |
| 46 | Credit Value of scrap copper to be deducted. |
| 47 | Providing and fitting of finished new aluminium wire windings with insulation in place of damaged windings including labour costs etc. (Both HV & LV) per Kg of winding. |
| 48 | Providing and fitting of finished new aluminium strip windings with insulation in place of damaged windings including labour costs etc. (Both HV & LV) per Kg of winding. |
| 49 | Credit Value of scrap Aluminium to be deducted. |
| 50 | Rewinding with re-insulation of existing copper conductors (HV) by way of providing and replacement of inter-layer insulation - per kg of winding. |
| 51 | Rewinding with re-insulation, ducting of existing copper conductors (LV) by way of providing and replacement of inter-layer insulation - per kg of winding. |
| 52 | Rewinding with re-insulation of existing aluminium conductors (HV) by way of providing and replacement of inter-layer insulation - per kg of winding. |
| 53 | Rewinding with re-insulation of existing aluminium conductors (LV) by way of providing and replacement of inter-layer insulation - per kg of winding. |
| 54 | Providing and fitting of Hot dipped galvanised MS nuts, bolts and washers of assorted sizes |
| 55 | Supply of Neoprene Rubberized Gasket Sheet |
| 56 | 3mm thick |
| 57 | 5mm thick |
| 58 | 6mm thick |
| 59 | Providing and fitting of LV (1.1 KV) porcelain bushings of rating: |
| 60 | 250 A |
| 61 | 630 A |
| 62 | 1000 A |
| 63 | 2000 A |
| 64 | Providing and fitting of HV porcelain bushings of rating: |
| 65 | 250 A, 17.5KV |
| 66 | 630 A, 17.5KV |
| 67 | 1000 A, 17.5KV |
| 68 | 2000 A, 17.5KV |
| 69 | 250 A, 36KV |
| 70 | 630 A, 36KV |
| 71 | 1000 A, 36KV |
| 72 | 3150 A, 36KV |
| 73 | Providing and fitting of metal part stem with allied fittings of transformer bushings (HV/ LV) as under: |
| 74 | Brass |
| 75 | Aluminium |
| 76 | Copper |
| 77 | Cost of 20 mm2 ACSR Conductor |
| 78 | Cost of 30 mm2 ACSR Conductor |
| 79 | Cost of 50 mm2 ACSR Conductor |
| 80 | 35 mm2 AB HT Cable (3x35 +1x35) XLPE 3C+ Earth |
| 81 | 50 mm2 AB HT Cable (3x35 +1x35) XLPE 3C+ Earth |
| 82 | 35 mm2 AB LT Cable (3x50 +1x35) XLPE (1.1 Kv, 3+1C, Al) |
| 83 | 50 mm2 AB LT Cable (3x50 +1x35) XLPE (1.1 Kv, 3+1C, Al) |
| 84 | 70 mm2 AB LT Cable (3x70 +1x35) XLPE (1.1 Kv, 3+1C, Al) |
| 85 | Heat shrinkable outdoor cable termination kit upto 70 mm (3 core) |
| 86 | Mid span Straight through joining kit for 1.1KVA ABC upto 120 sqmm |
| 87 | GI V cross-arm with top bracket including clamp |
| 88 | GI channel X- arm including clamps and braces |
| 89 | PG clamps for 50 mm2 ACSR conductor |
| 90 | Providing of transformer oil conforming to IS 335 (Preferred make: Power oil/ Indian Oil Servo/ HPCL) |
| 91 | Filtration of existing/ reclaimed T-oil on site at suitable temperature (inclusive of all logistics and charges for filtration plant, etc)(Process loss maximum of 5% allowed) |
| 92 | Impregnation /heat treatment to winding assembly of of 3 phase 415 V by way keeping it in an electric oven |
| 93 | 25 KVA |
| 94 | 63 KVA |
| 95 | 75 KVA |
| 96 | 100 KVA |
| 97 | 150 KVA |
| 98 | 175 KVA |
| 99 | 200 KVA |
| 100 | 250 KVA |
| 101 | Hiring charges of Electrician (for troubleshooting/ revamping of existing electrical fitting, etc. exclusive of specified works): |
| 102 | Hiring charges of Labourer for support of electrician |
| 103 | Mechanical transportation, loading, unloading and handling of various items such as H.T Transformers, coil assemblies, welding tools & plant, etc. using appropriate means of transport as under: |
| 104 | Private car, auto-rickshaw or similar with 1.0 km lead |
| 105 | Extra per kilometer for lead >1.0 kms upto 5.0 kms |
| 106 | Extra per kilometer for lead >5.0 kms upto 10.0 kms |
| 107 | Extra per kilometer for lead >10.0 kms upto 20.0 kms |
| 108 | Extra per kilometer for lead >20.0 kms upto 25.0 kms (Maximum) |
| 109 | Load carrier auto, mini van or similar with 1.0 km lead |
| 110 | Extra per kilometer for lead >1.0 kms upto 5.0 kms |
| 111 | Extra per kilometer for lead >5.0 kms upto 10.0 kms |
| 112 | Extra per kilometer for lead >10.0 kms upto 20.0 kms |
| 113 | Extra per kilometer for lead >20.0 kms upto 25.0 kms (Maximum) |
| 114 | Mini truck like Tata mobile, Bolero Camper or similar with 1.0 km lead |
| 115 | Extra per kilometer for lead >1.0 kms upto 5.0 kms |
| 116 | Extra per kilometer for lead >5.0 kms upto 10.0 kms |
| 117 | Extra per kilometer for lead >10.0 kms upto 20.0 kms |
| 118 | Extra per kilometer for lead >20.0 kms upto 25.0 kms (Maximum) Please Enable Macros to View BoQ information |