| 1 | Construction of embankment with approved material obtained from borrow pits with all lifts and leads, transporting to site by manual means within a lead of 5kms, spreading, grading to required slope and compacting to meet requirement of table 300-2 & clause 305 of MoSRT&H Specifications for Road & Bridge works (4th Revision)and as per the direction of engineer in charge. |
| 2 | Construction of embankment with approved materials deposited at site from roadway cutting and excavation from drain and foundation of other structures graded and compacted to meet requirement as per MORD technical Specification Clause 301 and direction of the Engineer in Charge (excluding cost of excavation and transportation to site). |
| 3 | Construction of granular sub-base by providing close graded granular sub base Grading III material as per table 401-1, spreading in uniform layer with moter grader on prepared surface, mixing by mix in place method with rotavator at OMC ,and compacting with vibratory roller to achieve the desired density complete as per clause 401 of MoSRT&H Specification for Road & Bridge works (4 th Revision) |
| 4 | Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including pre mixing the material with water at OMC in mechanical mix plant, carriage of mixed material by tipper to site, laying in uniform layers with paver in subbase/base course on well prepared surface and compacting with vibratory roller to achieve the desired density as per Clause 406 of MoSRT&H Specifications for Road & Bridge works (4th Revision). |
| 5 | Construction of Un-reinforced,plain cement concrete pavement M-30 grade over a prepared sub base with 43 grade using brande cement @ 350 kg per cum,coarse and fine aggregate conforming to IS 383, maximum size of coarse aggregate not exceeding 25 mm, mixed in a batching and mixing plant as per approved mix design, transported to site, spread, compacted finished in a continuous operation including provision of contraction, expansion, construction and longitudinal joints, joint filler, separation membrane, sealant primer, joint sealant, debonding strip, admixtures as approved, finishing to lines and grages as per drawing and as per Clause 602 of MoSRT&H specifications for Road & Bridge Works and as per as per specification & direction of the Engineer-in-Charge. |
| 6 | Earth work in excavation of foundation & plinth in hard soil including levelling the bed etc complete as per the direction of Engineer in charge. |
| 7 | Excavation for roadwork in soil with hydraulic excavator of 0.9 cum bucket capacity including cutting and loading in tippers, trimming bottom and side slopes, in accordance with requirements of lines, grades and cross sections, and transporting to the embankment location within all lifts and lead upto 1000m |
| 8 | Providing and filling manually with selected sand in layers not exceeding 200mm thick including watering and compacting with all leads and lifts etc. For finished item of work as per Specification. |
| 9 | Unit cost of NP3 hume pipes including cost of labour for laying hume pipes (900 mm dia.)and as per the direction of Engineer in charge.HPC 1000 mm Dia |
| 10 | Plain cement concrete of M-15 grade having maximum compressive strength of 150 kg./cm2 ( test to be conducted) on 150 mm. cubes tested at 28 days including curing (tests conducted in accordance with IS-456 & IS-516) & conforming to clause-302 of IRC 21/1987 using clean crusher broken hard granite coarse aggregate of 40 mm. size down grade of approved quality to be protested in the laboratory) obtained from approved quarry the proportion mix, grading conforming to relevant ISI/IRC codes pre-approved including arranging of reinforcement as per approved drawing including hoisting, lowering concrete in layers not exceeding 150 mm. thick each compacting with vibrator watering & curing for 28 days centering shuttering & finishing the exposed surface smooth providing grooves & beads where necessary including cost, conveyance royality & taxes of all labour machineries etc. required for the work complete in all respects including dismantling the centering & shuttering as per specification & direction of Engineer-in-Charge. (Foundation) |
| 11 | Upto Bed Level |
| 12 | Construction of precast RCC railing of M25 Grade, aggregate size not exceeding 12 mm, true to line and grade, tolerance of vertical RCC post not to exceed 1 in 500, centre to centre spacing between vertical post not to exceed 2000 mm, leaving adequate space between vertical post for expansion, complete as per approved drawings and technical specifications. |
| 13 | RCC of design mix of M-25 grade having specified characteristics compressive strength/ target mean strength of 300kg./cm2 in design mix with minimum quantity of cement as specified in IRC Code of 150 mm. cubes at 28 days curing after mixing & tests conducted in accordance with relevant clauses of IS 456/IS 516/IRC 216/1987/IRC-78/1983 using crusher broken granite course aggregate of 20mm. .sizes & proportion as specified in clause-302.6.2 of IRC 21/1987 & IS-10262 & subject to mix design in conformity with the grading & proportion of different materials for concrete as specified in the relevant codes of approved quality, obtained from approved quarry & using minimum quantity of cement confirming to codal provision including hoisting, lowering & laying concrete in layers not exceeding 15cm thick compacting with vibrators watering & curing for 28 days including water tight steel centering , shuttering & form works finishing the exposed surface smooth providing beads & grooves wherever necessary including cost, conveyance royalties and all other taxes of all materials with all leads & lifts, cost of all labour T&P & machineries etc. required for the work including dewatering if necessary, complete in all respects as per direction of the Engineer-in-Charge but excluding cost, conveyance of tor steel & binding wire & labour charges for straightening, cutting, bending, binding welding & tying the grills lapping spacing etc. where ever necessary & hoisting & placing in position ( to be paid separately as required for RCC works)Raft. Below Bed Level |
| 14 | Abutment & Pier (Above Bed) |
| 15 | Deck slab |
| 16 | RCC of design mix of M-30 grade having specified characteristics compressive strength/ target mean strength of 300kg./cm2 in design mix with minimum quantity of cement as specified in IRC Code of 150 mm. cubes at 28 days curing after mixing & tests conducted in accordance with relevant clauses of IS 456/IS 516/IRC 216/1987/IRC-78/1983 using crusher broken granite course aggregate of 20mm. .sizes & proportion as specified in clause-302.6.2 of IRC 21/1987 & IS-10262 & subject to mix design in conformity with the grading & proportion of different materials for concrete as specified in the relevant codes of approved quality, obtained from approved quarry & using minimum quantity of cement confirming to codal provision including hoisting, lowering & laying concrete in layers not exceeding 15cm thick compacting with vibrators watering & curing for 28 days including water tight steel centering , shuttering & form works finishing the exposed surface smooth providing beads & grooves wherever necessary including cost, conveyance royalties and all other taxes of all materials with all leads & lifts, cost of all labour T&P & machineries etc. required for the work including dewatering if necessary, complete in all respects as per direction of the Engineer-in-Charge but excluding cost, conveyance of tor steel & binding wire & labour charges for straightening, cutting, bending, binding welding & tying the grills lapping spacing etc. where ever necessary & hoisting & placing in position ( to be paid separately as required for RCC works) Wearing Coat |
| 17 | Supply of HYSD bars confirming to grade S-415 cutting bending, binding, lapping, splicing, welding etc. (conforming to ISI specification) & jointing if necessary by lapping & tying the grills & placing in position as required for RCC works as per the approved design, hoisting, lowering & laying position including cost & conveyance of tor steel & binding wires of 18 to 20 gauge(as to be approved by the Deptt.) etc. complete (weight of binding wire shall not be considered for payment at all which will be borne by the contractor (standard CO-efficient of different sizes of the steel shall be considered & welding & lapping should confirm to relevant clause of IRC-21/1987) |
| 18 | Back filling behind Abutments ,Wing walls & Return walls complete as per drawing &technical specification etc complete. |
| 19 | Providing gravel backing to revetments including cost, conveyance and royalty, taxes of all materials to the site, all labour, T & P complete as per direction of the Enginer-in-Charge. |
| 20 | Providing & laying filter media with granular crushed aggregates as per specification to a thickness of not less than 600mm with 40mm metal providing over the entire surface behind abutment, wing wall, return wall etc. complete. |
| 21 | Finishing wall surface with waterproof cement paint of aproved shade 2 coats including watering, curing,cost of all materials & labour etc. |
| 22 | Providing Rough Stone dry packing / pitching in approns and revetments for slope protection including cost and conveyance of all materials to site etc. complete (15cm and above)and as per the direction of Engineer in charge. |
| 23 | Providing weepholes in brick masonry/stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing |
| 24 | Providing and fixing of typical informatory sign board with Logo as per MORD specifications and drawing. Three MS Plates of 1.6 mm thick, top and middle plate duly welded with MS flat iron 25mm x 5m size on back on edges. The lower plate will be we be welded to 2 nos. 75mmX75mm of12 SWG sheet tubes posts duly embeded in cement concrete M-15 grade block of 450mm X450mmmm X600mm ,600mm below ground level. The top most diamond plate will be welded to middle plate by 47mmX 47mm of 12 SWG steel plate tube. All M.S will be stove embelded on both sides .Lettering and printing arrows border etc. will be painted with ready mixed synthetic enamelpaint of superior quality in required shade andcloure.All sections of framed posts and steel tube will be painted with primer and two coat of epoxy paint as per drawing clause 1701 and Annexure 1700.1 |
| 25 | Providing and fixing of typical Citizen Information board as per MORD specification and drawing. Three MS plates of 50 x 5 mm. thick, back plate duty welded with 75 mm dia steel tubes back on edges as per drawings. The upper and lowe plate will be welded with MS flat iron frame of 50mm x 5 mm. The steel tubes dully embeded in cement concrete M-15 grade blocksw of 600mm x 600 mm x 750 mm below ground level. All MS will be stove enameled on both sides. Lettering and printing arrows, border etc. will be painted with redimixed synthetic enamel paint of superor quality in required shade and colour. All selection of framed posts and steel tubes will be painted with primer and two coats of epoxupaint as per drawing Clause 1701 and Annexure - 1700.1. |
| 26 | Providing and erecting direction and place identification retro-reflectorized sign as per IRC 67made of high intensity grade sheeting vide Clause 801.3, fixed over Aluminium sheeting 2mm thick supported on a mild steel single/double angle iron post 75 x 75 x 6 mm firmly fixed to the ground by means of properly designed foundation with M 15 grade concrete 45 x 45 x 60 cm, 60 cm below ground level as per drawing and technical specfication Clause 801 of of specification for road & bridge works (5th revision) & as directed by Engineer in charge.90 cm Equilateral traingle |
| 27 | 60 cm Circular |
| 28 | 80 cm x 60 cm rectangular |
| 29 | 90 cm high octagon |
| 30 | Direction Marking |
| 31 | Hazard Marker |
| 32 | Providing and erecting Informatory retro-reflectorised sign as per IRC-67-2012 made of class-B retro-reflective sheeting of high intensity prismatic grade sheeting as per ASTMD4956-09type-III and IV strictly conforming to clause 6.7of IRC67-2012 and vide clause 801.3, fixed over aluminium sheeting, 2.00mm thick as per clause 6.5.2 of IRC:67-2012 or A.C.P (Aluminium Composite Panel) used for sign boards with a thermo plastic core of blow density polythylene (LDPE) between two thick sheets of aliminium with over all thickness of 4mm and aliminium thichness of 0.5mm on both sides supported on mildsteel square post 80mmx80mmx3mm, 2nos and 3nos horizontal and 1no vertical extra supporting member of M.Sangle of size 50mmx50mmx6mm firmly fixed to the ground by means properly designed foundation withM-15 grade cement concrete 45cmx45cmx75cm, 60cm below ground level of as per approved drawing including cost, conveyance, royality, taxes of all materials, labour, T&P, excavation, curingetc. complete,under supervision of Engineer-In-Charge.Size-12'X8'(3657mm x 2438mm Rectangle) |
| 33 | Providing and fixing of road stud 100x100mm, diecast in fibre, resistant to corrosive effect of salt and grit, fitted with lens reflectors, installed in concrete or asphaltic surface by suitable bituminous grout or epoxy |
| 34 | Provision for Road sinage masonary structure for citizen information board,painting of 200 m & k.m stone etc complete and as per the direction of engineer in charge.Ordinary Kilometer stone |
| 35 | 200 mm stone |
| 36 | Semi-reflectorised Sign Boards |
| 37 | 200 mm dia RCC guard post. Please Enable Macros to View BoQ information |