| 1 | Supplying and drawing following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in the existing surface / recessed steel / PVC conduit as required.a) 3 x 1.5 sq.mm |
| 2 | b) 3 x 4 sq.mm |
| 3 | Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc as required.a) 3 Module (100mmX75mm) |
| 4 | Supplying and fixing following modular switch / socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.a) 5/6 amp switch |
| 5 | b) 3 pin 5/6 amp socket outlet |
| 6 | c) 15/16 amp switch |
| 7 | d) 6 pin 15/16 amp socket outlet |
| 8 | e) 25A modular SP MCB \\"C\\" curve |
| 9 | Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.a) 3 Module |
| 10 | b) 6 Module |
| 11 | c) 8 Module |
| 12 | d) 12 Module |
| 13 | Supplying and fixing following way, single pole and neutral, sheet, steel, MCB distributions board, 240 volts, on surface/recess, complete with tinned copper busbar, neutral busbar, earth bar, din bar, detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)a) 16way Double door |
| 14 | Supplying and fixing of following ways surface/recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting CBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)a) 4 way (4 + 12), Double door |
| 15 | b) 8 way (4 + 24), Double door |
| 16 | Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.a) Single pole |
| 17 | Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.a) 40 amp |
| 18 | b) 63 amp |
| 19 | Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release an terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.a) 125 A, 16 KA,TPMCCB |
| 20 | b) 100 A, 16 KA,TPMCCB |
| 21 | Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. |
| 22 | Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required. |
| 23 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required. |
| 24 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required. |
| 25 | Supplying and fixing of pole box (195mmx135mmx90/100 deep) made out hot moulded SMC with 01no 16amp 3pole connector, din channel and 01 No. 6 Amp SPMCB complete with connections earthing testing etc as reqd. |
| 26 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.a) Upto 35 sq. mm |
| 27 | b) Above 35 sq. mm and upto 95 sq. mm |
| 28 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.a) Upto 35 sq. mm (clamped with 1mm thick saddle) |
| 29 | b) Above 35 sq. mm and upto 95 sq. mm (clamped with25x3mm MS flat clamp) |
| 30 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.a) 3 X 10 sq. mm (22mm) |
| 31 | b) 4 X 25 sq. mm (28mm) |
| 32 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc..direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.a) 63 mm dia (OD-63 mm & ID-51 mm nominal) |
| 33 | Supply, installation, testing and commissioning of panel board with dust & vermin proof IP-42 protection compartmentalized indoor type cubical panel board made out of not less than 1.6 mm thick CRCA sheet, the sheet steel member shall be stiffened by angle iron framed. The depth of cubical panel shall not be less than 300 mm and suitable sizes earth strip shall be provided around the cubical panel. The cubical panel shall be of suitable size to incorporate following switchgear i/c connections, powder coating of approved colour and shades complete etc. as reqd. Panel should be fixed on CC foundation/ angle iron frame work. 400A, 25KA, 4P incomer MCCB-1 No.100A 4P 25KA outgoing MCCB-02 Nos.125A 4P 25KA outgoind MCCB-05 Nos. 25/32A DP 10KA MCB- 3 NosCT's 400/5A class-1.0 15VA-03 NosDigital MFM -1 NoR,Y,B Phase Indicating Lamp-03Nos600A TPN, Aluminium Bus BarExtended Rotating Handle & Spreader -08 Nos |
| 34 | Supply, installation, testing and commissioning of panel board with dust & vermin proof IP-42 protection compartmentalized indoor type cubical panel board made out of not less than 1.6 mm thick CRCA sheet, the sheet steel member shall be stiffened by angle iron framed. The depth of cubical panel shall not be less than 300 mm and suitable sizes earth strip shall be provided around the cubical panel. The cubical panel shall be of suitable size to incorporate following switchgear i/c connections, powder coating of approved colour and shades complete etc. as reqd. Panel should be fixed on CC foundation/ angle iron frame work. 200A, 25KA, 4P incomer MCCB-1 No.100A 4P 25KA outgoing MCCB-01 No.125A 4P 25KA outgoind MCCB-01 No. 25/32A DP 10KA MCB- 3 NosCT's 200/5A class-1.0 10VA-03 NosDigital MFM -1 NoR,Y,B Phase Indicating Lamp-03Nos350A TPN, Aluminium Bus BarExtended Rotating Handle & Spreader -03 Nos |
| 35 | Disamntling of existing panel with suitable mechanical means at site and repair the same and store the electrical panel as per instruction of site engineer complete etc as reqd. |
| 36 | Installation, Testing and Commissioning of pre-wired, fluorescent fitting / compact fluorescent/ LED fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS/HFFR PVC insulated, copper conductor, single core cable and earthing etc. as required. |
| 37 | Supply and fixing of 15/16Amp 3pin top plug including connection complete as reqd. |
| 38 | Dismantling manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge :a) bituminous road |
| 39 | Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
| 40 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level a) 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size de rived from natural sources) |
| 41 | Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer -in - charge. a) Nominal concrete 1:4:8 or leaner mix (including equivalent design mix) |
| 42 | Taking out existing CC interlocking paver blocks from footpath/ central verge, including removal of rubbish etc., disposal of unserviceable material to the dumping ground, for which payment shall be made separately and stacking of serviceable material within 50 metre lead as per direction of Engineer-in-Charge. |
| 43 | Credit Material Assorted : SP /DP MCB upto 63 A |
| 44 | Assorted : SP/TPDB MCB DB |
| 45 | Assorted : cable |
| 46 | Assorted : panel |
| 47 | Assorted : Copper wire with insulation Please Enable Macros to View BoQ information |