| 1 | APPENDIX 1 |
| 2 | Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared |
| 3 | Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil |
| 4 | Extra for every additional lift 1.5 m or part there of in excavation / banking excavated or stacked materials.All kinds of soil |
| 5 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 6 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 7 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. up tot floor five level excluding cost of centering, shuttering, finishing and reinforcement :1:1.5:3( 1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 8 | Reinforced cement concrete work in beams, suspended floors, roofs, having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floor five level excluding the cost of centering, shuttering, finishing and reinforcement, with1:1.5:3 (1 cement : 1.5 coarse sand (Zone III) derived from natural sources: 3 graded stone aggregate 20 mm nominal size derived from natural sources). |
| 9 | Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more |
| 10 | Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete |
| 11 | Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc. |
| 12 | Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform |
| 13 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished welded type tubes |
| 14 | Providing corrugate G.S. sheet roofing including vertical/ curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete ( up to any pitch in horizontal / vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.1.00 mm thick with zinc coating not less than 275 gm/m2 |
| 15 | Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge.80 mm thick C.C. paver block of M-30 grade with approved color design and pattern. |
| 16 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in:Cement mortar 1:4 ( 1 cement : 4 coarse sand) |
| 17 | 12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand) |
| 18 | White washing with lime to give an even shade:New work (three or more coats) |
| 19 | Finishing walls with water proofing cement paint of required shade:New work (Two or more coats applied @ 3.84 kg/10 sqm) |
| 20 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade:New work (Two or more coats applied @ 1.43 ltr/ 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm) |
| 21 | Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels / subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI-212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineerin- charge. The product performance shall carry guarantee for 10 years against any leakage.For vertical surface two coats @0.70 kg per sqm |
| 22 | Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels / subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI-212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineerin- charge. The product performance shall carry guarantee for 10 years against any leakage.For horizontal surface one coat @1.10 kg per sqm. |
| 23 | Providing and fixing in position Pre-cast R.C.C. manhole cover and frame of required shape and approved quality. L D - 2.5Rectangular shape 600x450 mm internal dimensions |
| 24 | Constructing masonry chamber 30x30x50 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for stop cock, with C.I. surface box 100x100x75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4 mix (1 cement : 2 coarse sand: 4 graded stone aggregate 20 mm nominal size), i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design:With common burnt clay F.P.S (non modular) bricks of class designation 7.5 |
| 25 | Supplying stacking and placing in position Stone Aggregate (Single Size):20mm |
| 26 | Supplying,stacking and placing in position Stone Aggregate (Single Size):12.5 |
| 27 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m. |
| 28 | providing and fixing uPVC pipes including fixing the pipe with clamps at 1.00 m spacing. This included jointing of pipes with one step uPVC solvent cement and testing of joints complete as per direction of Engineer in charge |
| 29 | Providing and fixing uPVC pipes including fixinf the pipewith clamps/clips at 1.00 m spacing .This included jointing of pipes with one step uPVC solvent Cement and testing of joints as per direction of Engineer in charge-90mm dia 10kgf/cm2 |
| 30 | Providing and fixing uPVC pipes including fixing the pipe with clamps /clips at 1.00 m spacing .This included jointing of pipes with one step uPVC solvent cement and testing of joints complete as per direction of Engineer in Charge 25mm dia 10kgf/cm2 |
| 31 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 4.0 mm thickness (weight not less than 10kg/sqm) |
| 32 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 4.0 mm thickness (weight not less than 10kg/sqm) |
| 33 | For shutters of doors, windows & ventilators including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/ neoprene gasket required (Fittings shall be paid for separately)Anodised aluminium ( anodised transparent or dyed to required shade according to IS : 1868, Minimum anodic coating of grade AC 15) |
| 34 | Providing and fixing M.S. Grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.Fixed to openings/ wooden frames with rawl plugs screws etc |
| 35 | Providing and fixing factory made uPVC door frame made of uPVC extruded sections having an overall dimension as below (tolerance ±1 mm), with wall thickness 2.0mm (±0.2 mm), corners of the door frame to be jointed with galvanized brackets and stainless steel screws, joints mitred and plastic welded. The hinge side vertical of the frames reinforced by galvanized M.S. tube of size 19 x 19 mm and 1 mm (± 0.1 mm) wall thickness and 3 nos. stainless steel hinges fixed to the frame complete as per manufacturer's specification and direction of Engineer-in-chargeExtruded section profile size 48x40 mm |
| 36 | Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared |
| 37 | Brick work in C.M 1:5 mix using 2nd class ground moulded chamber burnt bricks with including cost |
| 38 | Extra for every additional lift 1.5 m or part there of in excavation / banking excavated or stacked materials.All kinds of soil |
| 39 | Extra for every additional lift 1.5 m or part there of in excavation / banking excavated or stacked materials.Ordinary or hard rock |
| 40 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 41 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 42 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. up tot floor five level excluding cost of centering, shuttering, finishing and reinforcement :1:1.5:3( 1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 43 | Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete |
| 44 | Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc. |
| 45 | Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more |
| 46 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished welded type tubes |
| 47 | Providing corrugate G.S. sheet roofing including vertical/ curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete ( up to any pitch in horizontal / vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.1.00 mm thick with zinc coating not less than 275 gm/m2 |
| 48 | Item Shifted to Sub head 14 as item 14.73 Item Shifted to head 14 as item 14.74 Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works |
| 49 | Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge.80 mm thick C.C. paver block of M-30 grade with approved color design and pattern. |
| 50 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in:Cement mortar 1:4 ( 1 cement : 4 coarse sand) |
| 51 | 12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand) |
| 52 | White washing with lime to give an even shade:New work (three or more coats) |
| 53 | Finishing walls with water proofing cement paint of required shade:New work (Two or more coats applied @ 3.84 kg/10 sqm) |
| 54 | Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels / subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI-212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineerin- charge. The product performance shall carry guarantee for 10 years against any leakage.For vertical surface two coats @0.70 kg per sqm |
| 55 | Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels / subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI-212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineerin- charge. The product performance shall carry guarantee for 10 years against any leakage.For horizontal surface one coat @1.10 kg per sqm. |
| 56 | Providing and fixing in position Pre-cast R.C.C. manhole cover and frame of required shape and approved quality. L D - 2.5Rectangular shape 600x450 mm internal dimensions |
| 57 | Providing and fixing G.I. chain link fabric fencing of required width in mesh size 50x50 mm including strengthening with 2 mm dia wire or nuts , bolts and washers as required complete as per the direction of Engineer-in- charge.Made of G.I. wire of dia 4 mm |
| 58 | Constructing masonry chamber 30x30x50 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for stop cock, with C.I. surface box 100x100x75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4 mix (1 cement : 2 coarse sand: 4 graded stone aggregate 20 mm nominal size), i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design:With common burnt clay F.P.S (non modular) bricks of class designation 7.5 |
| 59 | Supplying stacking and placing in position Stone Aggregate (Single Size):20mm |
| 60 | Supplying,stacking and placing in position Stone Aggregate (Single Size):12.5 |
| 61 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m. |
| 62 | Providing and fixing uPVC pipes including fixing the pipe with clamps /clips at 1.00 m spacing .This included jointing of pipes with one step uPVC solvent cement and testing of joints complete as per direction of Engineer in Charge 160mm dia 10kgf/cm2 |
| 63 | providing and fixing uPVC pipes including fixing the pipe with clamps at 1.00 m spacing. This included jointing of pipes with one step uPVC solvent cement and testing of joints complete as per direction of Engineer in charge |
| 64 | providing and fixing uPVC pipes 63 mm dia including fixing the pipe with clamps at 1.00 m spacing. This included jointing of pipes with one step uPVC solvent cement and testing of joints complete as per direction of Engineer in charge |
| 65 | Providing and fixing uPVC pipes including fixing the pipe with clamps /clips at 1.00 m spacing .This included jointing of pipes with one step uPVC solvent cement and testing of joints complete as per direction of Engineer in Charge 25mm dia 10kgf/cm2 |
| 66 | supplying of worms for sludge drying beds 1.10kg/sqm is 600 kg |
| 67 | supplying of specially designed crates / container for holding filter media including light weight coco husk size (2-16)mm and bio media including mixture of vermi compostcocopeat and bacterial culture with special worms per designed quantity including sprinklers transportation and fixing inposition as directed etc complete |
| 68 | Supplying and installation of earthing pit with G.I earth pipe 1.50 meter long, 40 mm dia including accessories, and providing masonary enclosure with copper plate of 20''X20'' having locking arrangement and watering pipe etc. with erthing chemical, charcoal/coke and salt as required. |
| 69 | Supplying and drawing following sizes of FRLS PVC insulated coper conductor in the existing surface/ recessed steel/ PVC conduit as required. 3 X 2.5 sq.mm (For Pumps and Machines) |
| 70 | Supplying and drawing following sizes of Armoured insulated aluminium conductor, four core cable in the existing surface/ recessed steel/ PVC conduit as required. 4 X 4 sq.mm (For Street Light) |
| 71 | Supplying and drawing following sizes of FRLS PVC insulated coper conductor 1.5 sq.mm 3 core & Shielded cable. 0.50 Sq.mm (For Flow Meter) (Excluding Conduit Pipe) |
| 72 | Supplying and drawing following sizes of galvanized 2.5 mm thick wire for earthing for individual equipment, motors and street lights. |
| 73 | Supplying and Installation of Control Panel including Starters for equipments, Moters and Street lights - Indoor sheet steel clad, cubicle type, dust and vermin proof (IP 52 indoor Panel), motor control venture, conforming to IS: 8623:1977, together with components as per attached list. Provide Suitable seprate earthing. Make of Switch- Siemens / L & T/ Eq. Control Panel Box with DOL Starters 8 Nos |
| 74 | Cabling- Electrical cabling shall be provided from control panel to various units of Sewage treatment plant. Copper /Al unarmored. |
| 75 | Supplying and Installation of Plant area lighting- LED light with Pole- 50 Watt LED Bulb (IP 66 enclosure) and MCB box with steel tubular swaged pole 5 m height and standard diameter and thickness with pole cap, base plate in foundation. (One Pole with two Light enclosure) |
| 76 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including 40 mm conduit. |
| 77 | Supplying and Installation of Eletromagnetic Flow Meter at Outlet (EFM-3) 2.5 inch Make- SFIC Micromag, Body- MS Fule bore with TEFLON LONNING Output- 4-20 mA/RS 485 l/p-230 AC Remote Mounting with 5 m cable flanged type |
| 78 | Sewage Pumps - Supplying Non-clog Submersible Pump suitable for sewage/ Liquid waste application with standard MOC Pump flow - 1.00 Cu.m/hr head 15 m. Bio Sludge Withdrawal Pump |
| 79 | Sewage Pumps - Supplying Non-clog Submersible Pump suitable for sewage/ Liquid waste application with standard MOC Pump flow - 3.06 Cu.m/hr head 28 m. Filter Feed Pumps |
| 80 | Sewage Pumps -Supplying Non-clog Submersible Pump suitable for sewage/ Liquid waste application with standard MOC Pump flow - 3.06 Cu.m/hr head 12 m. Treated Water Uplift Pump |
| 81 | Sewage Pumps -Supplying Non-clog Submersible Pump suitable for sewage/ Liquid waste application with standard MOC Pump flow - 3.06 Cu.m/hr head 15 m. Raw Sewage Lifting Pumps |
| 82 | BUTTERFLY VALVE (MANUAL) with C.I body SS Disc. Nitrate Rubber Seal & O-ring PN 16 pressure reting as specified |
| 83 | NON RETURN VALVE with Dual Plate of C.I body SS plates vulcanized NBR seal flanged end & PN 16 pressure rating as specified |
| 84 | Supplying and Installation of Screen Chamber SS 304 on site,Type- Readymade Screen Chamber MoC – SS 304, Spacing between bars – 6-10 mm. Screen Size - 0.30 X 1.20 m |
| 85 | Agitator for Anoxic Tank - Supplying Agitator with suitable capacity of 50 RPM, type-flange mounting. |
| 86 | Air Blower - Supplying and insatallation of Air Blower of capacity 106 m3/hr, discharge pressure - 0.5 kg/cm2 with motor |
| 87 | Air Grid for EQT and STP Tank |
| 88 | Media - MBBR Media of Effective Specific surface area - 250-450 m2/m3, Material of construction - Stabilized PP |
| 89 | Media - Tube Settler Media |
| 90 | Piping and accessories - All interconnescting plumbing material with required accessories and feetings such as elbow, tee ,valaves etc UPVC Piping Fitting. |
| 91 | MS piping for air blower line from Air blower |
| 92 | Rotameter - at outlet of Filter Feed Pump |
| 93 | Pressure Guage - 2.5\\", 0-7 kg/cm2, SS 304 |
| 94 | Level Switch - Float Type - for TANK- EQT, FFT, TWST |
| 95 | Supplying and Installation of Pressure Sand Filter Capacity (Normal-Maximum) – 3.06 m3/hr,Operating pressure - 2 Kg/cm², Shell diameter x HOS- 24” x 72” Vessel Material- FRP, Make- Pentair/Equivalent |
| 96 | Supplying and Installation Activeted carban filter Capacity (Normal-Maximum) – 3.06 m3/hrOperating pressure- 2 Kg/cm², Shell diameter x HOS- 24” x 72” Vessel Material- FRP, Make- Pentair/Equivalent |
| 97 | NaOCl Chlorinator Pump Diaphragm Type / peristaltic type / Solenoid / Max Flow Rate Upto 10 LPH Power Source Electric - Phase Single Material PP / PTFE (Teflon) / Voltage 230 Volt / Frequency 50Hz / Mixing Tank of 100 Ltrs capacity- 1 No / Dosing Pump- 2 Nos |
| 98 | G.I earth pipe 1.50 meter long, 40 mm dia including accessories, and providing masonary enclosure with copper plate of 20''X20'' having locking arrangement and watering pipe etc. with erthing chemical, charcoal/coke and salt as required. |
| 99 | Supplying and drawing following sizes of FRLS PVC insulated coper conductor in the existing surface/ recessed steel/ PVC conduit as required. 3 X 2.5 sq.mm (For Pumps and Machines) |
| 100 | Supplying and drawing following sizes of Armoured insulated aluminium conductor, four core cable in the existing surface/ recessed steel/ PVC conduit as required. 4 X 4 sq.mm (For Street Light) |
| 101 | Supplying and drawing following sizes of FRLS PVC insulated coper conductor 1.5 sq.mm 3 core & Shielded cable. 0.50 Sq.mm (For Flow Meter) (Excluding Conduit Pipe) |
| 102 | Supplying and drawing following sizes of galvanized 2.5 mm thick wire for earthing for individual equipment, motors and street lights. |
| 103 | Supplying and Installation of Control Panel including Starters for equipments, Moters and Street lights - Indoor sheet steel clad, cubicle type, dust and vermin proof (IP 52 indoor Panel), motor control venture, conforming to IS: 8623:1977, together with components as per attached list. Provide Suitable seprate earthing. Make of Switch- Siemens / L & T/ Eq. Control Panel Box with DOL Starters 6 Nos |
| 104 | Supplying and Installation of Plant area lighting - LED light with Pole - 50 Watt LED Bulb (IP 66 enclosure) and MCB box with steel tubular swaged pole 5 m height and standard diameter and thickness with pole cap, base plate in foundation. (One Pole with two Light enclosure) |
| 105 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including 40 mm conduit. |
| 106 | BUTTERFLY VALVE (MANUAL) with C.I body SS Disc. Nitrate Rubber Seal & O-ring PN 16 pressure reting as specified |
| 107 | NON RETURN VALVE with Dual Plate of C.I body SS plates vulcanized NBR seal flanged end & PN 16 pressure rating as specified |
| 108 | Supplying and Installation of Eletromagnetic Flow Meter at Outlet (EFM-3) 2.5 inch Make- SFIC Micromag, Body- MS Fule bore with TEFLON LONNING Output- 4-20 mA/RS 485 l/p-230 AC Remote Mounting with 5 m cable flanged type |
| 109 | Supplying and Installation of Screen Chamber SS 304 on site,Type- Readymade Screen Chamber MoC – SS 304, Spacing between bars – 6-10 mm, Screen size- 0.50 X 1.00 m |
| 110 | Sewage Pumps -Supplying Non-clog Submersible Pump suitable for sewage/ Liquid waste application with standard MOC Pump flow- 1.375Cu.m/hr head 10 m. |
| 111 | Grit Pumps -Supplying Non-clog Submersible Pump suitable for Sludge/Grit removal application with standard MOC Pump flow- 1.25 Cu.m/hr head 6 m. |
| 112 | Supplying and Installation of Pressure Sand Filter Capacity (Normal-Maximum) – 1.25 m3/hr,Operating pressure- 2 Kg/cm², Shell diameter x HOS- 14” x 65” Vessel Material- FRP, Make- Pentair/Equivalent |
| 113 | Supplying and Installation Activeted carban filter Capacity (Normal-Maximum) – 1.25 m3/hr Operating pressure- 2 Kg/cm², Shell diameter x HOS- 14” x 65” Vessel Material- FRP, Make- Pentair/Equivalent |
| 114 | NaOCl Chlorinator Pump Diaphragm Type / peristaltic type / Solenoid / Max Flow Rate Upto 10LPH Power Source Electric - Phase Single Material PP / PTFE (Teflon) / Voltage 230 Volt / Frequency 50Hz / Mixing Tank of 100 Ltrs capacity- 1 No / Dosing Pump- 2 Nos |
| 115 | Supplying of worms for Sludge drying beds 1.10 kg/Sq.m is 600kg |
| 116 | Supplying of Specially designed crates/container for holding Filter media includingLightweight coco husk size (2-16mm)and Bio media including mixture of Vermicompost, cocopeat and bacterial culture with special worms per designed quantityincluding sprinklers ,transportation and fixing in position as directed etc. complete Please Enable Macros to View BoQ information |