| 1 | DSR Item No.1.3Wiring for light point/ fan point/ exhaust fan point/ callbell point with 1.5 sq.mm FRLS/HFFR PVC insulatedcopper conductor single core cable in surface/recessed medium class PVC conduit, with modularswitch, modular plate, suitable GI box and earthingthe point with 1.5 sq.mm FRLS/HFFRPVC insulated copper conductor single core cable etc. as required. |
| 2 | Group-A |
| 3 | DSR Item No.1.15Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ Recessed steel/PVC conduit including dismantling as required. |
| 4 | Group A |
| 5 | DSR Item No.1.11Wiring for twin control light point with 1.5 sq.mmFRLS/HFFR PVC insulated copper conductor singlecore cable in surface / recessed medium class PVCconduit, 2way modular switch, modular plate, suitableGI box and earthing the point with 1.5 sq.mmFRLS/HFFR PVC insulated copper conductor singlecore cable etc. as required. |
| 6 | DSR Item No.1.17 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/recessed steel/ PVC conduit as required. |
| 7 | 3 x 1.5 sq. mm |
| 8 | 3 x 2.5 sq. mm |
| 9 | 3 x 4 sq. mm |
| 10 | DSR Item No.1.24Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 11 | 5/6 A switch |
| 12 | DSR Item No.1.27Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. |
| 13 | 6 Module (200mmX75mm) |
| 14 | 8 Module (125mmX125mm) |
| 15 | DSR Item No.1.26Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. |
| 16 | DSR Item No.1.21Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 17 | 25 mm |
| 18 | DSR Item No.1.33Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required. |
| 19 | DSR Item No.1.31Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. |
| 20 | DSR Item No.1.32Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. |
| 21 | DSR ITEM NO.2.10Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 22 | Single pole |
| 23 | Triple pole and neutral |
| 24 | Supplying and Erection of MCB TPN of 40 amp. The MCB TPN shall be installed in existing enclosure with suitable arrangement. The job includes cost of labour, incoming &outgoing connection, making hole and other petty material required to complete the job to the entire satisfaction of Engineer –in-charge of the work. The MCB TPN should be of Schneider/ Siemens/ Havells/ Hagar/ ABB/ Legrand/ Lauritz Knudsen make only |
| 25 | DSR Item No. 2.14Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 26 | Supply and erection of Sheet steelenclosure for RCCB/ MCB DP/ MCB TPN . The job includes cost of labour, making connection, making hole and other petty material required to complete the job to the entire satisfaction of Engineer in charge of the work.The MCB TPN should be of Schneider/ Siemens/ Havells/ Hagar/ ABB/ Legrand/ Lauritz Knudsen make only |
| 27 | DSR Item No.15.15Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required. |
| 28 | 63 mm dia (OD-63 mm & ID-51 mm nominal) |
| 29 | Labour charges for horizontal boring 1 Mtr. Below ground level including cost of 2 Nos. Pit digging and refilling complete in all respects upto entire satisfaction of the EIC of the work. |
| 30 | DSR item No. 15.16Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. |
| 31 | 63 mm dia (OD-63 mm & ID-51 mm nominal) |
| 32 | DSR item No. 5.1Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but without charcoal/ coke and salt ) as required. |
| 33 | DSR ITEM NO.5.6Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 34 | DSR ITEM NO.5.7Supplying and laying 6 SWG G.I. wire at 0.50 metre belowground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required. |
| 35 | DSR ITEM NO.5.8Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm) |
| 36 | DSR Item No. 7.4Supplying, installation, testing and commissioning of Astronomical time switch of following configuration to be mounted in feeder pillars / Lighting DBs for automatic switching On& OFF of street lights at sun set & sun rise or twilight (Auto ON, Auto OFF, Auto modes) with manual override facility with 12/24 hour display format with suitable battery and indication for relay status i/c programming at site complete as required. |
| 37 | 1 output per phase and suitable for single phase supply |
| 38 | DSR item no.2.4Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, dinbar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator). |
| 39 | 4 way (4 + 12), Double door |
| 40 | DSR Item no. 2.24Supplying and fixing Cable End Box (Loose Wire Box) suitable for following triple pole and neutral, sheet steel, MCB distribution board, 415 Volts, on surface/ recess, complete with testing and commissioning etc.as required. |
| 41 | For 4 way, Double door TPN MCBDB |
| 42 | DSR item no. 8.10LED Batten light (System lumen efficacy ≥120 <135 lm/Watt) Supplying, installation, Testing & Commissioning of LED surface mountedBatten light of following body material and construction as per IS : 10322with driver (Replaceable) as per the requirement with Driver efficiency>85% ,Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temprange -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV withShort & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80,Flicker free, (flicker should be below 5 %), life time (LED,Driver & electricalcircuitry), of minimum 50000 Burning Hours with , 70% of initialLumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K/6000°K/6500°K (As per ANSI Bin), SDCM(Standard Deviation ColorMatching) <3, Maximum power consumption should not more than thespecified rating and Fixture shall be of relevant BIS standard and trademark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/Embossing/ Screen printing on housing. complete in all respect i/cconnections with 1.5 sq mm FRLS, PVC insulated copper conductorsingle core cable and earthing etc. as required with Minimum 5 year OEMwarranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80Test report from NABL lab for all testing required for LED fixtures asper BIS shall be submitted. Shape size and CCT shall be as approved byEngineer-in-Charge as per requirement. (Thermal management: heat sinkof aluminum housing such that LED junction temperature shall not riseabove 90°C).Powder Coated CRCA Sheet Body (Thickness >0.50 mm) |
| 43 | 18-22 watt |
| 44 | DSR item no.8.2LED Down lighter (SMD Type) (System lumenefficacy ≥120<135lm/Watt)Supplying, installation, Testing & Commissioning ofLED Recessed/surface Down lighter (Round/square/ Rectangular) SMD type of following bodymaterial with PMMA and prismatic diffuser andconstruction as per IS : 10322 with driver as perthe requirement with Driver efficiency >85%,Operating voltage AC 140-270 Volt, frequency50/60 hz, Operating temp range -5 0C to 40 0Ccentigrade, internal surge protection of 2.5 KVwith Short & Open circuit protection ,THD < 10%,P. F.≥0.95, IP20, CRI >80, UGR (Unified GlareRating) <19, Flicker free (flicker should be below 5%), life time (LED, Driver & electrical circuitry), lifetime of minimum 50000 Burning Hours with 70%of initial Lumen maintained till life ends, CCT3000°K / 4000°K / 5700°K /6500°K (As perANSI Bin), SDCM(Standard Deviation ColorMatching) <3, Maximum power consumptionshould not more than the specified rating andFixture shall be of relevant BIS standard.Manufactures Word Mark/ Name Engraved/Embossing/ Screen printing on housing Completein all respect i/c external connections with 1.5 sqmm FRLS/HFFR, PVC insulated copper conductorsingle core cable and earthing etc. as required withMinimum 5 year OEM warranty. System lumenefficacy ≥120 <135 lm/Watt output . LM79 & LM80Test report and all testing required for LEDfixtures as per BIS shall be submitted.. Shape sizeand CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management:heat sink of aluminium housing such that LEDjunction temperature shall not rise above 90°C).Powder coated die cast /Extruded aluminiumBody including trim . |
| 45 | 22 watt(Square type) |
| 46 | Supply and fixing of G.I box of size 200 mm x 150 mm suitable for accommodate the following accessories along with Modular switch with modular plate and cover for switches in recess / surface etc as required for Computer Point with 4 Nos. 5/6 Amp. Modular type switch and 4 Nos. 3 pin 5/6 Amp. Modular type socket outlet. The job includes the cost of making interconnections with suitable copper wire, painting of box with approved paint and other petty material required to complete the job to the entire satisfaction of Engineer-in-Charge at site. |
| 47 | DSR item no.8.16 LED Flood Light, powder coated pressure die cast aluminium (System lumen efficacy ≥120 and <135 lm/Watt)Supplying, installation, Testing & Commissioning of FloodLight, powder coated pressure die cast aluminium body withbuilt in or separate driver as per the requirement with Driverefficiency >85%, Input voltage: Input voltage: 140-270 Volt AC,freq 50/60 hz, Operating temp range -5 deg to 50 degcentigrade, internal surge protection of 5 KV L,N,E as per IEC61000-4-5, Driver efficiency >85%,THD< 10% as per IEC61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltageand over voltage protection,EMI-EMC as per CISPR-15,lenses for beam angle 30 deg-120deg as per the application andthe project requirementdeg, suitable tilt able fitting, life time(LED,Driver& electrical circuitary) of minimum 50000 BurningHours with 70% of initial Lumen maintained till life ends asper LM80 extrapolation IES TM-21-11 report, CCT 3000°K /4000°K / 5700°K /6500°K (As per ANSI Bin),SDCM(Standard Deviation Color Matching) <5, Maximumpower consumption should not more than the specified ratingand Fixture shall be of relevant BIS standard complete in allrespect i/c external connections with 1.5 sq mmFRLS/HFFR, PVC insulated copper conductor single corecable and earthing etc. as required with Minimum 5 year OEMwarranty. System lumen efficacy ≥120 and <135 lm/Wattoutput . LM79 & LM80 Test report and all testing required forLED fixtures as per BIS shall be submitted.. Shape size andCCT shall be as approved by Engineer-in-Charge as perrequirement. (Thermal management: heat sink of aluminiumhousing such that LED junction temperature shall not rise above90°C). |
| 48 | 200 watt |
| 49 | DSR item no.8.13LED Street light fixture, powder coated pressuredie cast aluminium body (System lumen efficacy≥120 <135 lm/Watt)Supplying, installation, Testing & Commissioning of Street light LED fixture powder coated pressure die cast aluminum body with driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -15 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2 , P. F.≥0.95, IP-66,IK-10, CRI >80, under voltage and over voltage protection, EMIEMC As per CISPR 15 , lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C). |
| 50 | 90 watt |
| 51 | Supply and erection of ceiling fan 48”.The job include carriage, erection, testing and commissioning and making connection with copper wire from the adjacent light point and other petty material labour etc. as required to complete the job to the entire satisfaction of Engineer-in-charge. The ceiling fan should be Bajaj/ Usha/ Crompton/ Orient/ Havells make only. |
| 52 | DSR item no.1.25Supplying and fixing two module stepped type electronic fanregulator on the existing modular plate switch box includingconnections but excluding modular plate etc. as required. |
| 53 | Supply, Erection, Testing and commissioning of Thermo Plastic cable Jn. Box IP55 of size 130x180x77 mm deep approximate with 4 nos. thermal block suitable for 1 no. incoming and 3 nos. outgoing cables. The terminal block shall be made of Hansel make with terminal link or its equivalent make Wago/ Elmex/ Siemens/ Syntax/ Everest only and cable junction box of make Hansel/ Legrand/ Syntax or its equivalent to IP55. The job includes all labour and petty material to required complete the job to the entire satisfaction of the Engineer in Charge. |
| 54 | S/E of M.S. bracket (‘L’ shape) made from 40mmx40mmx 5mm thick angle iron to be installed on existing parapet / wall with the help of suitable size of Fastener etc. for erection of metal halide flood light fitting. The job includes cost of painting of bracket with superior quality of paint and other all petty material etc. as required to complete the job. |
| 55 | Supply and laying of PVC insulated PVC sheathed Aluminum conductor cable of 1.1 KV grade as per IS 7098 (Part-I) 1988 (amended up to date) of the following sizes to be laid direct on surface with the help of M.S. clamp of suitable thickness. The job include the cost of making connections with suitable size of Al. Lugs / thimbles, testing, commissioning etc. as required to the entire satisfaction of Engineer In Charge. The cable should be ofPolycab / Havells / Finolex / RR Kabel/ KEI/ RPG/ Universal/ Grandlay make only. |
| 56 | Size 16 Sq.mm 4 core PVC Al. Un.Arm. Cond. Cable |
| 57 | Size 16 Sq.mm 4 core PVC Al. Arm. Cond. Cable |
| 58 | Size 70 Sq.mm 3.5 core PVC Al. Arm. Cond. Cable |
| 59 | Size 35 Sq.mm 3.5 core PVC Al. Arm. Cond. Cable |
| 60 | Size 120 Sq.mm 3.5 core PVC Al. Arm. Cond. Cable |
| 61 | Supply and Laying of PVC Armored Aluminum conductor cable in existing pipe/trench. This also includes making connections, testing, commissioning, all labour and petty material required to complete the job. The cable should be ISI marked of Polycab / Havells / Finolex / RR Kabel/ KEI/ RPG/ Universal/ Grandlay make only. The job includes all labour and petty material required to complete the job to the entire satisfaction of the E.I.C of the work. |
| 62 | Size 16 Sq.mm 4 core PVC Al. Arm. Cond. Cable |
| 63 | Supply and erection of Contactor T AC3 70 AMP RATING AND 100 AMPS RATING FOR AC1 unit suitable for 3 phase switching on/off. The job includes cost of 1 no. 3 phase MNX 70 CS97076 with built in SURGE SUPPRESSOR for coil of 220 Volt 50/60 Hz Rating L&T MNX/ Siemens 3TF/ ABB AX series. The contactor shall be installed on existing bakelite sheet with help nut and bolt. The job includes making incoming and outgoing connection with suitable copper wire and other petty material require to complete the job to the entire satisfaction of Engineer- in- charge. |
| 64 | Fabrication, Supplying, Installation, Testing and Commissioning of indoor type double door Electric Control Panel of cubical construction conforming to IEC 61439 (Part I & Part II), floor mounted type, fabricated out of 2 mm thick CRCA sheet, compartmentalized with hinged lockable doors, dust and vermin proof, powder coated of approved shade. The panel shall be fabricated with 16 SWG CRCA sheet steel for load bearing surfaces and 16 SWG for non-load bearing surfaces and shall be powdered coated from inside after proper nine tank chemical treatment process and outside Siemens Grey (RAL7035). The base frame of panel shall be painted with black. The panel have suitable capacity TPN Aluminum bus bars of electrolytic grade E91 with cross section 1 x 25 x 10 mm per phase & 1 x 25 x 10 mm for neutral, earthing studs, DMC/ SMC bus bar supports, base frame of MS channel 100mm x 50mm x 6mm size, having switchgears and accessories , internal wiring with 2.5 sq.mm PVC insulated single core cable or as per load, common copper earth bar of size 25 x 5 mm over the entire width of panel and 2 nos. earth studs, cable entry from the top & bottom, cable gland plates, numbering, labeling etc. complete in all respect, suitable for operation on 415 V, 3 phase, 50 Hz. AC supply with protection class IP 42 as required. The panel should be provided with lifting hook, locks, hinges, nut bolts etc. in order to bear the load of the panel during installation of the panel. Each feeder shall have engraved anodized AL nameplates with each feeder details & rating. The feeder name plate panel name plate and manufacturers name plate shall be secured by screws and also the panel should have MV danger notice plate. The panel should have continuous earth bus of Aluminum run at the bottom of the panel. The panel shall have removable gland plates at top/bottom and bus bars/cable entry shall be from top/bottom as required. The SLD should be marked on the panel. The RYB phase indicator should be of ABB/ESS-BEE/Schneider make only. The job includes the cost of MCCB’s accessories, interconnection with solid connection, carriage and installation of cubical panel at site to the entire satisfaction of Engineer in charge. The cubical panel should be of ABB/Legrand/Schneider make only. The outdoor type double door Electric Control Panel should have provision of following switchgear and accessories:- (Note:- (Note: All MCCBs shall be with ROM, Spreader terminals) |
| 65 | Part-A (Block A & B) (Sub main panel for power load) |
| 66 | INCOMING |
| 67 | Space for 1 no 63/100 amp MCCB 4 pole in the panel |
| 68 | BUS BAR |
| 69 | Supply and erection of TPN Aluminum bus bars of electrolytic grade E91 (having 100% Neutral) of minimum of 63/100 Amps. Capacity with heat shrinkable colored sleeves and i/c DMC/SMC bus bar supports at required intervals complete for cross section, size supports & their spacing etc. for withstanding fault level of 31 MVA for 1 Sec. The current density of aluminum bus shall be 1 Amp/sq. mm.- 1 Set. |
| 70 | OUTGOING |
| 71 | Space for MCB TPN 32 Amp:-4 Nos. |
| 72 | Part-B (Block A & B) (Sub main panel for light load) |
| 73 | INCOMING |
| 74 | Space for MCB TPN 40 Amp:-1 No. |
| 75 | BUS BAR |
| 76 | Supply and erection of TPN Aluminum bus bars of electrolytic grade E91 (having 100% Neutral) of minimum of 40 Amps. Capacity with heat shrinkable colored sleeves and i/c DMC/SMC bus bar supports at required intervals complete for cross section, size supports & their spacing etc. for withstanding fault level of 31 MVA for 1 Sec. The current density of aluminum bus shall be 1 Amp/sq. mm.- 1 Set. |
| 77 | OUTGOING |
| 78 | Space for MCB TPN 32 Amp:-4 Nos. |
| 79 | Part-C (Block A) (Main panel for power load) |
| 80 | INCOMING |
| 81 | Space for 1 No. 250 Amps. 4 pole MCCB in the panel |
| 82 | BUS BAR |
| 83 | Supply and erection of TPN Aluminum bus bars of electrolytic grade E91 (having 100% Neutral) of minimum of 250 Amps. Capacity with heat shrinkable colored sleeves and i/c DMC/SMC bus bar supports at required intervals complete for cross section, size supports & their spacing etc. for withstanding fault level of 31 MVA for 1 Sec. The current density of aluminum bus shall be 1 Amp/sq. mm.- 1 Set. |
| 84 | OUTGOING |
| 85 | Space for 6 nos 63/100 amp MCCB 4 pole in the panel |
| 86 | Part-D (Block A) (Main panel for light load) |
| 87 | INCOMING |
| 88 | Space for 1 No. 200 Amps. 4 pole MCCB in the panel |
| 89 | BUS BAR |
| 90 | Supply and erection of TPN Aluminum bus bars of electrolytic grade E91 (having 100% Neutral) of minimum of 250 Amps. Capacity with heat shrinkable colored sleeves and i/c DMC/SMC bus bar supports at required intervals complete for cross section, size supports & their spacing etc. for withstanding fault level of 31 MVA for 1 Sec. The current density of aluminum bus shall be 1 Amp/sq. mm.- 1 Set. |
| 91 | OUTGOING |
| 92 | Space for 6 nos 63/100 amp MCCB 4 pole in the panel |
| 93 | Part-E (Block B) (Main panel for power load) |
| 94 | INCOMING |
| 95 | Space for 1 No. 250 Amps. 4 pole MCCB in the panel. |
| 96 | BUS BAR |
| 97 | Supply and erection of TPN Aluminum bus bars of electrolytic grade E91 (having 100% Neutral) of minimum of 250 Amps. Capacity with heat shrinkable colored sleeves and i/c DMC/SMC bus bar supports at required intervals complete for cross section, size supports & their spacing etc. for withstanding fault level of 31 MVA for 1 Sec. The current density of aluminum bus shall be 1 Amp/sq. mm.- 1 Set. |
| 98 | OUTGOING |
| 99 | Space for 8 nos 63/100 amp MCCB 4 pole in the panel. |
| 100 | Part-F (Block B) (Main panel for Light load) |
| 101 | INCOMING |
| 102 | Space for 1 No. 200 Amps. 4 pole MCCB in the panel. |
| 103 | BUS BAR |
| 104 | Supply and erection of TPN Aluminum bus bars of electrolytic grade E91 (having 100% Neutral) of minimum of 250 Amps. Capacity with heat shrinkable colored sleeves and i/c DMC/SMC bus bar supports at required intervals complete for cross section, size supports & their spacing etc. for withstanding fault level of 31 MVA for 1 Sec. The current density of aluminum bus shall be 1 Amp/sq. mm.- 1 Set. |
| 105 | OUTGOING |
| 106 | Space for 8 nos 63/100 amp MCCB 4 pole in the panel. |
| 107 | DSR item no.2.2 Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. |
| 108 | 100 A,30KA,FPMCCB |
| 109 | 200 A,36KA,FPMCCB |
| 110 | 250 A,50KA,FPMCCB |
| 111 | S/E of LED Bulk Head Luminaries weather proof frosted light with PMMA/ PC reflector and silicon gasket to be installed on surface. The LED fitting should have minimum system Lumen output minimum 1000 Lumen at 100 lm/ watt (minimum) and the driver of the fitting should be workable on 140-260 Volt. The colour temperature of LED should be minimum 5000 degree Kelvin. The fitting should be of Philips/ Bajaj/ Wipro/ Havells/ Jaquar/ Crompton/ Panasonic/ Surya/ LT/ Trilux make only. The fitting should be of IP-65/66. The LED should have a life of 50000 burning Hours. The fitting should have THD<15% and power factor 0.9 or above. The job includes the cost of testing, commissioning and making connection with copper wire from adjacent light point, other petty material and labour etc. as required to complete the same to the entire satisfaction of Engineer In Charge. |
| 112 | DSR item no.4.1Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required. |
| 113 | 200 mm width X 50 mm depth X 1.6 mm thickness Please Enable Macros to View BoQ information |