| 1 | DSR Item No.1.24 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 2 | 5/6 A switch |
| 3 | 3 pin 5/6 A socket outlet |
| 4 | 15/16 A switch |
| 5 | 6 pin 15/16 A socket outlet |
| 6 | DSR 8.10 LED Batten light (System lumen efficacy ≥120 <135 lm/Watt) Supplying, installation, Testing & Commissioning of LED surface mounted Batten light of following body material and constructionas per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range -5 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80 , Flicker free (flicker should be below 5 %), life time (LED, Driver & electrical circuitary), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained tilllife ends,CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulatedcopper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output. LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall besubmitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).Powder Coated CRCA Sheet Body (Thickness > 0.50 mm)18- 22 Watt |
| 7 | 18-22 watt |
| 8 | DSR Item no. 8.15 (2025)LED Flood Light, powder coated pressure die castaluminium (System lumen efficacy 105 <120 lm/Watt)Supplying, installation, Testing & Commissioning of FloodLight, powder coated pressure die cast aluminium body withbuilt in or separate driver as per the requirement with Driverefficiency >85%, Input voltage: Input voltage: 140-270 VoltAC, freq 50/60 hz, Operating temp range -5 deg to 50 degcentigrade, internal surge protection of 5 KV L,N,E as per IEC61000-4-5, Driver efficiency >85%,THD < 10% as per IEC61000-3-2 , P. F.≥0.95, IP-66,IK-10, CRI >70, under voltageand over voltage protection,EMI-EMC as per CISPR -15,lenses for beam angle 30 deg-120deg as per the application andthe project requirementdeg., suitable tilt able fitting, life time(LED,Driver & electrical circuitary) of minimum 50000 BurningHours with 70% of initial Lumen maintained till life ends asper LM80 extrapolation IES TM-21-11 report, CCT 3000°K /4000°K / 5700°K /6500°K (As per ANSI Bin) ,SDCM(Standard Deviation Color Matching) <5, Maximumpower consumption should not more than the specified ratingand Fixture shall be of relevant BIS standard complete in allrespect i/c external connections with 1.5 sq mmFRLS/HFFR, PVC insulated copper conductor single corecable and earthing etc. as required with Minimum 5 year OEMwarranty. System lumen efficacy 105 <120 lm/Watt output.LM79 & LM80 Test report and all testing required for LEDfixtures as per BIS shall be submitted.. Shape size and CCTshall be as approved by Engineer-in-Charge as per requirement.(Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). |
| 9 | 100 watt |
| 10 | DSR 9.1 Brush Less DIrect Current (BLDC) fan with remote Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal( Aluminum alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, remote (prefreably mobile app based) for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistancemore than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Ceiling Fan compliant to IS 374:2019 fan Supply, earthing etc. complete as req.1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum) |
| 11 | Supply and Erection of B.L Holder on the existing junction box/ wooden block including making the connection etc as required. The job includes the all labour and petty material charges required to complete the job to the entire satisfaction of E.I.C. of work. Approved makes: Anchor/ Goldmedal/ Lauritz Knudsen / Havells make only. |
| 12 | S/E of LED Bulk Head Luminaries weather proof frosted light with PMMA/ PC reflector and silicon gasket to be installed on surface. The LED fitting should have minimum system Lumen output minimum 1000 Lumen at 100 lm/ watt (minimum) and the driver of the fitting should be workable on 140-260 Volt. The colour temperature of LED should be minimum 5000 degree Kelvin. The fitting should be of Philips/ Bajaj/ Wipro/ Havells/ Jaquar/ Crompton/ Panasonic/ Surya/ LT/ Trilux make only. The fitting should be of IP-65/66. The LED should have a life of 50000 burning Hours. The fitting should have THD<15% and power factor 0.9 or above. The job includes the cost of testing, commissioning and making connection with copper wire from adjacent light point, other petty material and labour etc. as required to complete the same to the entire satisfaction of Engineer In Charge. |
| 13 | S/E of MS bracket (F shape) made from 40mmx40mmx5mm thick angle iron to be installed on existing parapet/ wall with the help of suitable size of nuts/ bolts etc for erection of flood light/ street light fittings. the job includes cost of painting of bracket with superior quality of paint and other all petty material etc as required to complete the job. |
| 14 | S/L of PVC insulated sheathed al. conductor unamored cable 10 sq.mm 2 core flat with 8 SWG GI wire on existing surface with suitable clamps/ hanger etc including making connection and petty material etc as required. The cable should be of Polycab / Havells / Finolex / RR Kabel/ KEI/ RPG/ Universal/ Grandlay make only. |
| 15 | Supply and Erection of Cement Collar and Jn. Box at the base of the pole with the detailed specification as given below.: |
| 16 | Jn. Box Construction: |
| 17 | Supply & fixing of OEM made Junction box IP-66/67 made out of Polycarbonate with Glass fiber reinforced of size 205x255x112 (mm) (minimum) with 5 Nos. OEM made connectors/ terminal blocks. The Jn. Box and connectors/ terminal blocks should be supplied by OEM. The terminal blocks/ connectors should be of Hensel / Wago / Elmax / Siemens make only and junction box shall be of Hensel make KF 2525 G or its equivalent Clipsal / Legrand / Rittal / Schneider / ABB make only. The Junction box shall be fire retardant and self extinguishing. The gasket material shall be polyurethane and the gasket shall be internally embedded. The job includes all labour and petty material required to complete the job to the entire satisfaction of the Engineer in Charge of work. |
| 18 | Cement Collar: |
| 19 | The box shall be enclosed in a Cement Collar made from Cement Concrete 1:2:4 with outside dia 16” as required at site. |
| 20 | The collar shall be embedded in the ground upto 6” shall stand 9” above ground shall have height equal to PVC Junction box and 6” top over the box. |
| 21 | The collar shall be provided with 2 Nos. DWC Pipes of 50mm dia 45cm long each to facilitate the entry of cables in the Jn. Box. |
| 22 | The collar shall be plastered, properly finished and painted with 2 coats of exterior apex of superior quality. |
| 23 | The item includes other petty material to complete the job including new thimbles & making connections. |
| 24 | The job includes all labour and petty material inclusive of putty required to complete the job to the entire satisfaction of the Engineer In Charge of the work. |
| 25 | Supply & Erection of 3 mm thick white glazed bakelite sheet on existing M.S. box. The job includes the cost of sheet and making holes & cutting and fixing with screws as required to complete the job. The bakelite should be of Superhylam/ Formica/ Greenlam (ISI marked) make only. Please Enable Macros to View BoQ information |