| 1 | NOTE:-(i) The bidders/contractors are advised to read tender document & all corrigendum / amendments and General conditions of contracts before entrying/quoting the rates.(ii) It is highlighted that the certain condition of General Condition of Contracts (IAFW-2249) has been modified as per direction of MoD i.e. inclusssion of Performance Security, deletion of Risk & Cost Provisions and increase in defect liability period all as per tender documents. The tenderers should keep in mind while quoting their offer. (iii) (Applicable for all items/parts):- The bidders/contractors are advised to refer Notes on BOQ/SCH'A' before entry/quoting the rates. |
| 2 | Demolition of brick work or stone/boulder masonry, built in cement mortar including all quions, arches, pillers etc complete all as specified and as directed. |
| 3 | Demolition of stone slab or tiles of any description or thickness in floors or aprons etc (laid bedded and pointed in any mortar) complete all as specified and as directed. |
| 4 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed. |
| 5 | Taking down cement plaster of any description built in cement mortar on brick or stone walls etc including racking out joints, hacking for Key, scrubbing down with water etc. complete all as specified and as directed. |
| 6 | Demolition of cement concrete (reinforced) of any description and any position not otherwise specifically provided for (reinforcement cut as required to facilitate demolition) and removal of rubbish from the site complete all as specified and as directed. |
| 7 | Demolition of reinforced cement concrete in roofs, floors (other than ground floors), beams staircases, landing, chajjas and similar suspended work (reinforcement to be cut as required to facilitate demolition) complete all as specified and as directed. |
| 8 | Demolition of cement concrete of (unreinforced) any description and any position not otherwise specifically provided for and removal of rubbish from the site complete all as specified and as directed. |
| 9 | Demolition of cement concrete (unreinforced) in ground floors and paving not exceeding 15cm thick (below or above ground level) and removal of rubbish from the site complete all as specified and as directed. |
| 10 | Dismantling posts or struts (wood, steel or R.C.C.) any section, including taking out embedded portion from Concrete, brick work, masonry, etc. and making good to disturbed ground as in natural ground/ concrete level complete all as specified and as directed. |
| 11 | Dismantling fencing wire mesh, any type (Galvanised/ Steel barbed wire) complete all as specified and as directed. |
| 12 | Excavation in trenches not exceeding 1.50m wide and not exceeding 1.50m in depth for foundations or for shafts, wells, cesspits, manholes, pier holes etc. not exceeding 10Sqm on plan and not exceeding 1.50m in depth and getting out in soft/loose soil complete all as specified and as directed. |
| 13 | Excavation in post holes (or similar holes) each not exceeding 0.5 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around in layers not exceeding 25 cm, watering and removing surplus soil to a distance not exceeding 50m and making good disturbed surface in any type of soil complete all as specified and as directed. |
| 14 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm on soft/loose soil complete all as specified and as directed. |
| 15 | Removing excavated materials not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and as directed. |
| 16 | Material and labour for hardcore of gauge not exceeding 63mm, deposited, spread and levelled in layers not exceeding 15cm thick, watered and rammed to a true surface complete all as specified and as directed. |
| 17 | Material and labour for providing cement concrete 1:4:8 type D-2 (using 40 mm graded crushed stone aggregate) as in foundation, filling and mass concreting complete all as specified and as directed. |
| 18 | Material and labour for providing cement concrete 1:3:6 type C-2 (using 40 mm graded crushed stone aggregate) as in foundation, filling and mass concreting complete all as specified and as directed. |
| 19 | Material and labour for PCC (1:3:6) type C2 (using 40mm graded stone aggregate) as in surface channel, drains and like etc. complete all as specified and as directed. |
| 20 | Material and labour for PCC 1:2:4, type B-1 (using 20mm graded stone aggregate) as in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, including necessary use and waste of formwork complete all as specified and as directed. |
| 21 | Material and labour for reinforced cement concrete 1:2:4 type B1 (Nominal Mix) (using 20mm graded stone aggregate) as in as in column, pillars, piers, posts and struts complete all as specified and as directed. |
| 22 | Material and labour for providing precast cement concrete (1:2:4), type B-1, (using 20mm graded aggregate) as in landings, cover slabs(for manholes, etc.), chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces set in cement mortar (1:4) including necessary use and waste of form work complete all as specified and directed.Note: Reinforcement shall be measured and paid seperately under respective item. |
| 23 | Material and labour for 100mm thick PCC (1:4:8) type D2 (using 40mm graded stone aggregate) as in sub base floring and finish the surface fair and even complete all as specified and as directed. |
| 24 | Material and labour for 40mm thick PCC (1:2:4) type B1 (using 20mm graded stone aggregate) in alternative panel as in sub base floring and finish the surface even and smooth without using extra cement complete all as specified and as directed. |
| 25 | Material and labour for plastic dividing strips 38mm wide and 1.5mm thick, inserted in position for design of the PCC floor complete all as specified and as directed. |
| 26 | Material and labour required extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends etc. complete all as specified and as directed. |
| 27 | .-Ditto- all as per item No 25.00 above but add or deduct for each 25mm girth or part there of over or under 30cm and -ditto-. |
| 28 | Material and labour for brick work with sub class `B` bricks, old size, straight or curved on plan exceeding 6m mean radius built in cement mortar (1:6) complete all as specified and as directed. |
| 29 | Material and labour for brick work with sub class `B` bricks, old size, straight or curved on plan exceeding 6m mean radius built in cement mortar (1:4) complete all as specified and as directed. |
| 30 | Materials and labour for half brick thick brick work with old size sub class 'B' bricks straight or curved on plan to any radius built in cement mortar (1:4) complete all as specified and as directed. |
| 31 | Material and labour for flat formwork to sides of pillars,posts,struts,piers,columns and stanchions with rough finished flat surface complete all as specified and as directed. |
| 32 | Material and labour for mild steel TMT bars 10mm dia and over, cut to length bent to shape required, including cranking bending spirally for hooping for columns , hooking ends and binding with and including mild steel wire (annealed) not less than 0.90mm dia or securing with clips complete all as specified and as directed. |
| 33 | Material and labour for mild steel TMT bars 6 to 8mm dia, cut to length bent to shape required, including cranking bending spirally for hooping for columns , hooking ends and binding with and including mild steel wire (annealed) not less than 0.90mm dia or securing with clips complete all as specified and as directed. |
| 34 | Material and labour for mild steel TMT bars 5mm dia and over and upto and including 10mm dia, cut to length bent to shape required, including cranking bending spirally for hooping for stirrups, spacers, binders and binding with and including mild steel wire (annealed) not less than 0.90mm dia or securing with clips complete all as specified and as directed. |
| 35 | Materials and labour for mild steel fencing posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 complete all as specified and as directed. |
| 36 | Material & Labour for Mild steel screw bolts 5mm to 10mm dia of neck (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, exceeding 5cm and not exceeding 10cm long complete all as specified and as directed. |
| 37 | Supply and fixing 4mm dia galvanised steel wire, 100x100mm mesh, made up into mattresses or cages, lapped, wired and laid in position, including closing after filling and fixing with bolt complete all as specified and as directed. |
| 38 | Fixing only Chain link fencing 4mm dia galvanised steel wire,100x100mm mesh, made up into mattresses or cages, lapped, wired and laid/fixed in position, including line wires, any mesh, any size,any type of standards rails straining bolts etc including provisioning of binding wires complete all as specified and directed. |
| 39 | Supply and fixing galvanised. 2 strand, steel barbed wire 2.24mm dia. barbed with 2mm dia. barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. as in repair complete all as specified and as directed. |
| 40 | Material and labour for precast Cement Concrete chequered tiles of size 200 x 200 x 25mm thick as in floor, set and jointed in neat cement slurry and pointed with cement laid over and including 20mm thick screed bed in CM (1:4) complete all as specified and as directed. |
| 41 | Material and labour for antiskid vitrified paving tiles of size 300 x 300 x 10mm thick as in floor, set and jointed in neat cement slurry and pointed with cement laid over and including 20mm thick screed bed in CM (1:4) complete all as specified and as directed. |
| 42 | Material and labour for providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footparth, parks, lawns, drive ways or light traffic parking etc. of required strength, thickness & size/shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand complete all as specified and as directed. |
| 43 | Material and labour for Granite work (of any type) 20 mm thick (table rubbed and polished) in slab, jambs, platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with granite shade complete all as specified and as directed. |
| 44 | Materials and labour for 15 mm thick rendering on brick work in cement mortar (1:4) and finished the surfaces even and smooth without using extra cement complete all as specified and as directed. |
| 45 | Materials and labour for 15 mm thick rendering on fair faces of brick work or concrete surface in cement mortar (1:4) with using water proofing coumpound and as per manufacturer specification and finished the surfaces even and smooth without using extra cement complete all as specified and as directed.Note : WPC will be measured and paid separately. |
| 46 | Supply only liquid integral water proofing compound conforming to IS-2645 complete all as specified and directed. |
| 47 | Material and labour for preparation of old plastered surfaces by brooming down or steel wire brushing, scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots and applying one coat of cement base paint on walls complete all as specified and as directed. |
| 48 | Materials and labour for preparation of old plastered surfaces of wall and applying one coat of white wash complete all as specified and as directed. |
| 49 | Material and labour for applying two coats of cement base paint over a coat of alkali resistant primer including preparation of newly plastered surfaces of wall complete all as specified and as directed. |
| 50 | Material and labour for preparation of new steel surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamal paint over a coat of red oxide zinc chrome primer complete all as specified and as directed. |
| 51 | Material and labour for preparation of new steel surfaces of any description not exceeding 10 cm width or girth and applying two coats of black bituminous paint complete all as specified and as directed. |
| 52 | Material and labour for Cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-l smooth finished, and reforming benching as required for 150mm dia of pipe complete all as specified and as directed. |
| 53 | Material and labour for PCC 1:3:6, type C2, (using 40mm graded stone aggregate) as in concrete bed to drain pipes including packing under, and haunching against the sides of pipes after they are laid and tested for 150mm bore of pipe complete all as specified and as directed.Note: Pipes shall be measured and paid seperately. |
| 54 | Dismantling 150mm bore cast iron or reinforced concrete drain pipes including all fittings, jointed in cement mortar and taking out of trenches/wall, if required complete all as specified and as directed. |
| 55 | Supply, laying and testing of 150 mm internal diameter of double wall corrugated (DWC) high density polyethylene pipes (HDPE) and stiffness class SN-8 with ISI marked (with valid CML No.) with and including all fittings and jointing material for sewerage line and laid in trenches as specified in IS-16098-2013 Part-2 complete all as specified and as directed. |
| 56 | Supply and fixing as in replacement 110 mm dia PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to wall with suitable size of MS flat iron clamp complete all as specified and as directed. |
| 57 | Supply and fixing as in replacement 75 mm dia PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to wall with suitable size of MS flat iron clamp complete all as specified and as directed. |
| 58 | Supply and fixing 110 mm bore PVC (SWR) bends any radius with oval access door complete all as specified and directed. |
| 59 | Supply and fixing 75 mm bore PVC (SWR) bends any radius with oval access door complete all as specified and directed. |
| 60 | Supply and fixing 110 mm bore, PVC (SWR) branch pieces, single (single ‘Y’) equal or unequal complete all as specified and as directed. |
| 61 | Supply and fixing 75 mm bore PVC (SWR) vent cowl complete all as specified and as directed. |
| 62 | Supply and fixing 75mm dia, PVC (SWR) floor trap, plain with grating including jointing with solvent cement complete all as specified and as directed. |
| 63 | Supply and fixing 125/110 mm dia, PVC (SWR) gully trap, including jointing with solvent cement complete all as specified and as directed. |
| 64 | Material, labour, Tools and Plants for cleaning of sewage line of any dia/bore including manhole using the cleaning devices as per rule 5 and protective gear and safety devices as per rule 4 of the Prohibition of Employment as Manual Scavengers and their Rehabilitation Rules, 2013 and removing blockage if any complete all as specified and as directed. |
| 65 | Material, labour, Tools and Plants for Cleaning of manholes and removing sludge from manholes of any size and depth and depositing the sludge and spreading in low lying areas and covering with loose soil, as per rule 5 and protective gear and safety devices as per rule 4 of the Prohibition of Employment as Manual Scavengers and their Rehabilitation Rules, 2013 and removing blockage if any complete all as specified and as directed. |
| 66 | Material, labour, Tools and Plants for cleaning of blockage of wash basin, floor trap, nahani trap, gully trap (GT), kitchen, bath etc. (carrying sullage) in any length up to the first manhole by any means (using chemical or any mechanical device) & flushing with water as per as per rule 5 and protective gear and safety devices as per rule 4 of the Prohibition of Employment as Manual Scavengers and their Rehabilitation Rules, 2013 and removing blockage if any complete all as specified and as directed. |
| 67 | Material, labour, Tools and Plants for cleaning/desludging of septic tank/soak well of any capacity and size users using the cleaning devices with sewage suction truck as per rule 5 and protective gear and safety devices as per as per rule 5 and protective gear and safety devices as per rule 4 of the Prohibition of Employment as Manual Scavengers and their Rehabilitation Rules, 2013 and removing blockage if any complete all as specified and as directed. |
| 68 | Material and labour for complete removal of plants with roots from walls/shafts of any storey high building by using copper sulphate, acid or salt or by any other method and making hole of size 15x15x15 cm and filling with PCC (1:2:4) type B0 (using 12.5mm graded stone aggregate) and making good the disturbed surfaces with existing complete all as specified and as directed. |
| 69 | Removal of unwanted grass, plants and vegitations by cutting shrubs, bushes etc around septic tanks, soakage well, drain etc thoroughly by wire brushing including flushing with water and remove from site not less than 50 mtr from starting point complete all as specified and as directed. |
| 70 | Material, labour, Tools and Plants for cleaning/de-silting of loose mud, rubbish etc from drain bed including removal of all vegetation growth thoroughly and wire brushing including flushing with water so as to achieve smooth flow of water in drain of bed width up to 60 cm and depth etc complete all as directed. Please Enable Macros to View BoQ information |