|
| 1 | Supply and fixing of LED Street light Fitting with mandatory driver set having die cast aluminium body with toughened glass/ UV stabilized PC Cover and lenses suitable for 45 Watt to 50 Watt confirming to IP 66 and IK07 and above protection having Company LOGO Engraved including labour, Connection wire and cables, GI Bracket, two set of iron clamps as required with 5 years warrantee/ guarantee with replacement as per direction of the Engineer in charge complete in all respects having Specifications as : – ”5400-6000 System Lumen, High Power LED with lenses , 120 L,m/w, PF > 0.95, THD < 10% at full load, CRI> 70, Polled Driver Set in metal housing (Not Circuitry), Phase to Phase Protection at 440 V & > 300 V over voltage auto cut and restart feature, 4 KV internal Surge Protection.” CAT – AAA (S.I No. 23.14 PWD Schedule 2024) |
| 2 | Supply and fixing of LED Street light Fitting with mandatory driver set having die cast aluminium body with toughened glass/ UV stabilized PC Cover and lenses suitable for 60 Watt to 72 Watt confirming to IP 66 and IK07 and above protection having Company LOGO Engraved including labour, Connection wire and cables, GI Bracket, two set of iron clamps as required with 5 years warrantee/ guarantee with replacement as per direction of the Engineer in charge complete in all respects having Specifications as : – ”7200-8640 System Lumen, High Power LED with lenses , 120 L,m/w, PF > 0.95, THD < 10% at full load, CRI> 70, Polled Driver Set in metal housing (Not Circuitry), Phase to Phase Protection at 440 V & > 300 V over voltage auto cut and restart feature, 4 KV internal Surge Protection.” CAT – AAA (S.I No. 23.15 PWD Schedule 2024) |
| 3 | Supply and fixing of LED Street light Fitting with mandatory driver set having die cast aluminium body with toughened glass/ UV stabilized PC Cover and lenses suitable for 75 Watt to 90 Watt confirming to IP 66 and IK07 and above protection having Company LOGO Engraved including labour, Connection wire and cables, GI Bracket, two set of iron clamps as required with 5 years warrantee/ guarantee with replacement as per direction of the Engineer in charge complete in all respects having Specifications as : – ”9000-10800 System Lumen, High Power LED with lenses , 120 L,m/w, PF > 0.95, THD < 10% at full load, CRI> 70, Polled Driver Set in metal housing (Not Circuitry), Phase to Phase Protection at 440 V & > 300 V over voltage auto cut and restart feature, 4 KV internal Surge Protection.” CAT – AAA (S.I No. 23.16 PWD Schedule 2024) |
| 4 | Supply and fixing of LED Street light Fitting with mandatory driver set having die cast aluminium body with toughened glass/ UV stabilized PC Cover and lenses suitable for 100 Watt to 130 Watt confirming to IP 66 and IK07 and above protection having Company LOGO Engraved including labour, Connection wire and cables, GI Bracket, two set of iron clamps as required with 5 years warrantee/ guarantee with replacement as per direction of the Engineer in charge complete in all respects having Specifications as : – ”13200-15600 System Lumen, High Power LED with lenses , 120 L,m/w, PF > 0.95, THD < 10% at full load, CRI> 70, Polled Driver Set in metal housing (Not Circuitry), Phase to Phase Protection at 440 V & > 300 V over voltage auto cut and restart feature, 4 KV internal Surge Protection.” CAT – AAA (S.I No. 23.17 PWD Schedule 2024) |
| 5 | Supply and fixing of LED Street light Fitting with mandatory driver set having die cast aluminium body with toughened glass/ UV stabilized PC Cover and lenses suitable for 140 Watt to 150 Watt confirming to IP 66 and IK07 and above protection having Company LOGO Engraved including labour, Connection wire and cables, GI Bracket, two set of iron clamps as required with 5 years warrantee/ guarantee with replacement as per direction of the Engineer in charge complete in all respects having Specifications as : – ”16800-18000 System Lumen, High Power LED with lenses , 120 L,m/w, PF > 0.95, THD < 10% at full load, CRI> 70, Polled Driver Set in metal housing (Not Circuitry), Phase to Phase Protection at 440 V & > 300 V over voltage auto cut and restart feature, 4 KV internal Surge Protection.” CAT – AAA (S.I No. 23.18 PWD Schedule 2024) |
| 6 | Supply and fixing of LED Street light Fitting with mandatory driver set having die cast aluminium body with toughened glass/ UV stabilized PC Cover and lenses suitable for 160 Watt to 175 Watt confirming to IP 66 and IK07 and above protection having Company LOGO Engraved including labour, Connection wire and cables, GI Bracket, two set of iron clamps as required with 5 years warrantee/ guarantee with replacement as per direction of the Engineer in charge complete in all respects having Specifications as : – ”19200-21000 System Lumen, High Power LED with lenses , 120 L,m/w, PF > 0.95, THD < 10% at full load, CRI> 70, Polled Driver Set in metal housing (Not Circuitry), Phase to Phase Protection at 440 V & > 300 V over voltage auto cut and restart feature, 4 KV internal Surge Protection.” CAT – AAA (S.I No. 23.19 PWD Schedule 2024) |
| 7 | Supply & fixing of factory wired intergal LED flood light luminaries with die cast aluminum housing built with driver set suitable for 100Watt. To 120Watt confirming to IP 66 and IK07 and above protection having Company LOGO Engraved including labour, Connection wire and cables, GI Bracket, two set of iron clamps as required with 5 years warrantee/ guarantee with replacement as per direction of the Engineer in charge complete in all respects having Specifications as : – ”12000-14400 System Lumen, High Power LED with lenses , 120 L,m/w, PF > 0.95, THD < 10% at full load, CRI> 70, Polled Driver Set in metal housing (Not Circuitry), Phase to Phase Protection at 440 V & > 300 V over voltage auto cut and restart feature, 4 KV internal Surge Protection.” CAT – AAA (S.I No. 23.24 PWD Schedule 2024) |
| 8 | Supply & fixing of factory wired intergal LED flood light luminaries with die cast aluminum housing built with driver set suitable for 140Watt. To 150Watt confirming to IP 66 and IK07 and above protection having Company LOGO Engraved including labour, Connection wire and cables, GI Bracket, two set of iron clamps as required with 5 years warrantee/ guarantee with replacement as per direction of the Engineer in charge complete in all respects having Specifications as : – ”16800-18000 System Lumen, High Power LED with lenses , 120 L,m/w, PF > 0.95, THD < 10% at full load, CRI> 70, Polled Driver Set in metal housing (Not Circuitry), Phase to Phase Protection at 440 V & > 300 V over voltage auto cut and restart feature, 4 KV internal Surge Protection.” CAT – AAA (S.I No. 23.25 PWD Schedule 2024) |
| 9 | Supply & fixing of factory wired intergal LED flood light luminaries with die cast aluminum housing built with driver set suitable for 170Watt. To 200Watt confirming to IP 66 and IK07 and above protection having Company LOGO Engraved including labour, Connection wire and cables, GI Bracket, two set of iron clamps as required with 5 years warrantee/ guarantee with replacement as per direction of the Engineer in charge complete in all respects having Specifications as : – ”20400-24000 System Lumen, High Power LED with lenses , 120 L,m/w, PF > 0.95, THD < 10% at full load, CRI> 70, Polled Driver Set in metal housing (Not Circuitry), Phase to Phase Protection at 440 V & > 300 V over voltage auto cut and restart feature, 4 KV internal Surge Protection.” CAT – AAA (S.I No. 23.26 PWD Schedule 2024) Please Enable Macros to View BoQ information |