| 1 | Annual Maintenance of Water Works Campus |
| 2 | 13.88:Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. |
| 3 | 13.98.1:Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade:One or more coats on old work |
| 4 | 13.99.1:Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :One or more coats on old work |
| 5 | 13.43.1:Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer |
| 6 | 14.72:Providing and fixing double scaffolding system (cup lock type) on the exterior side, upto seven story hight made with 40 mm dia. M.S. tube 1.5 m centre to centre, horizontal & vertical tubes joining with cup & lock system with M.S. tubes, M.S. tube challies, M.S. clamps and M.S. staricase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for the required duration as approved and removing it there after. The scaffolding system shall be stiffened with bracings, runners, connection with the building etc wherever required for inspection of work at required location with essential safety features for the workmen etc. complete as per directions and approval of Engineer- in Charge. The elevational area of the scaffolding shall be measured for payment purpose. The payment will be made once irrespective of duration of scaffolding. Note:- This item to be used for maintenance work judicially, necessary deduction for scaffolding in the existing item to be done . |
| 7 | 15.56:Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. |
| 8 | 13.1.2:12 mm cement plaster of mix:1:6 (1 cement : 6 fine sand). |
| 9 | 15.23.1:Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead.For thickness of tiles 10 mm to 25 mm |
| 10 | 11.37:Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete |
| 11 | 8.31:Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in- Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. |
| 12 | 11.41.2:Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600 x 600 mm. |
| 13 | 14.1.1:Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground within 50 meters lead:With cement mortar 1:4 ( 1 cement : fine sand) |
| 14 | 14.5.1:Renewing glass panes, with putty and nails wherever necessary including racking out the old putty :Float glass panes of thickness 4 mm (weight not less than 10kg/sqm) |
| 15 | 13.112.1:Finishing walls with Premium Acrylic Smooth exterior paint with Siliconeadditives of required shadeOld work (Two or more coats applied @ 1.43 ltr/ 10 sqm) over existing cementpaint surface |
| 16 | 9.113:Providing and fixing bright finished 100 mm mortice lock with 6 levers without pair of handles of approved quality for aluminium door, with necessary screws etc complete as per direction of Engineer- in- charge. |
| 17 | 100.98.1028:Engaging Mason ( average). |
| 18 | 100.98.1008:Engaging Coolie. |
| 19 | 100.98.1009:Engaging Fitter ( grade 1). |
| 20 | 100.98.1035:Engaging sewer man. |
| 21 | 100.98.1029:Engaging Carpenter (average) |
| 22 | OD245799/2025-2026:Engaging Electrician |
| 23 | 100.98.1032:Engaging Technician. |
| 24 | 2.31:Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared |
| 25 | 50.9.15.5:Providing and fixing iron hooks and eyes: 100 mm |
| 26 | 50.9.15.1:Supplying and fixing 200 mm Aluminium aldrop |
| 27 | 50.2.33.5:Cutting branches of trees overhanging above any structures of girth between 40cm to 60cm including stacking of serviceable materials and disposal of unserviceable material, cost of labour, hire charges of rope and pully etc without making any damages to nearby structures etc complete. |
| 28 | 50.2.33.6:Cutting branches of trees overhanging above any structures of girth between 60cm to 90cm including stacking of serviceable materials and disposal of unserviceable material, cost of labour, hire charges of rope and pully etc without making any damages to nearby structures etc complete |
| 29 | 50.2.33.7:Cutting branches of trees overhanging above any structures of girth between 90cm to 120cm including stacking of serviceable materials and disposal of unserviceable material, cost of labour, hire charges of rope and pully etc without making any damages to nearby structures etc complete. |
| 30 | 50.2.33.8:Cutting branches of trees overhanging above any structures of girth beyond 120cm including stacking of serviceable materials and disposal of unserviceable material, cost of labour, hire charges of rope and pully etc without making any damages to nearby structures etc complete. |
| 31 | 50.14.1.1:Removing and refixing door shutters after necessary repairs for easy opening and closing etc complete as per the direction of site Engineer-in-charge. |
| 32 | 50.14.1.2:Removing and refixing window shutters after necessary repairs for easy opening and closing etc complete as per the direction of site Engineer-in-charge |
| 33 | 50.18.7.3.2:Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 25 mm dia 10Kgf/ cm2- Internal work- Exposed on wall |
| 34 | 50.18.7.4.2:Providing and fixing PVC, pipes fittings including fixing the pipe with clamps at 1.00 m spacing. this includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 32 mm dia 6 Kgf/cm2 - internal work- Exposed on wall |
| 35 | 50.18.7.5.1:Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 40 mm dia 10 Kgf/cm2- Internal work- exposed on wall |
| 36 | 50.18.7.6.2:Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing . This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 50 mm dia 6 Kgf/cm2 - Internal work- Exposed on wall |
| 37 | 50.18.8.9.2:Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes with one step PVC Solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 110 mm pipe 4 kgf/cm2 |
| 38 | 17.2.1:Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required:W.C. pan with ISI marked white solid plastic seat and lid |
| 39 | 17.18.1:Providing and fixing P.V.C. low level flushing cistern with manually controlled device (handle lever) conforming to IS: 7231, with all fittings and fixtures complete.10 litre capacity - White |
| 40 | 17.7.7:Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:White Vitreous China Flat back wash basin size 450x300 mm with single 15 mm C.P. brass pillar tap |
| 41 | 18.17.1:Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :25 mm nominal bore |
| 42 | 18.17.2:Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :32 mm nominal bore |
| 43 | 18.17.3:Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :40 mm nominal bore |
| 44 | 18.17.4:Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :50 mm nominal bore |
| 45 | 18.17.1A:Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :20 mm nominal bore |
| 46 | 18.18.1:Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete:15 mm nominal bore |
| 47 | 18.18.2:Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete:20 mm nominal bore |
| 48 | 18.18.3:Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete:25 mm nominal bore |
| 49 | 18.53.1:Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS: 893115 mm nominal bore |
| 50 | 18.21.1.1:Providing and fixing uplasticised PVC connection pipe with brass unions:30 cm length15 mm nominal bore |
| 51 | 18.50.1:Providing and fixing C.P brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms.15 mm nominal bore |
| 52 | 18.54.2:Providing and fixing PTMT bib cock of approved quality and colour.15 mm nominal bore, 122 mm long, weighing not less than 99 gms |
| 53 | 9.57.1:Providing and fixing ISI marked IS : 1341 oxidised M.S. pressed butt hingeswith necessary screws etc. complete. (Copper oxidized as per IS 1378).125x65x2.12 mm |
| 54 | 9.59.2:Providing and fixing ISI marked oxidised M.S. single acting spring hinges withnecessary screws etc. complete. (Copper oxidized as per IS 1378).125 mm |
| 55 | 9.85:Providing and fixing bright finished brass. casement window fastener with necessary screws etc. complete. |
| 56 | 9.68.2:Providing and fixing oxidised M.S. casement stays (straight peg type) withnecessary screws etc. complete. (Copper oxidized as per IS : 1378).250 mm weighing not less than 150 gms. |
| 57 | 6.1.2:Brick work with common burnt clay F.P.S (non modular) bricks of class designation 7.5 in foundation and plinth in:Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 58 | 4.1.4:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (1 Cement : 2 coarse sand (zone-III) derived from natural sources : 4 gradedstone aggregate 40 mm nominal size derived from natural sources) |
| 59 | 4.1.5:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 60 | 14.75A:Cleaning of terrace/loft water storage tank (inside surface area) upto 2000 litre capacity at all heights with coconut brushes, duster etc., removal of silt, rubbish from the tank and cleaning the tank with fresh water disinfecting with bleaching powder @ 0.5gm per litre capacity of tank including marking the date of cleaning on the side of tank body with the help of stencil and paint and disposing of malba all complete as per direction of Engineer-in-Charge. (The old date already written on tank should be removed with paint remover or black paint and if date is not written with the stencil or old date is not removed deduction will be made @ Rs. 0.10 per litre) (if during cleaning any GI fittings or ball cock is damaged that is to be repaired by contractor at his own cost and nothing extra will be paid on this account) |
| 61 | OD245794/2025-2026:Cleaning 100mm line with cleaning rod- Cleaning the silt deposited inside the sewer line of 100mm dia with the help of sewer cleaning equipment and scrappers fitted in nylon wire inserted from one manhole to next removing floated matters and silt collected in the lower manhole conveying and carrying the same in suitable places as directed by deptl officers including cost of oil, carbolic soap, phenyl and hire charges for the bucket and other tools etc. complete |
| 62 | OD245792/2025-2026:Cleaning 150mm line with cleaning rod- Cleaning the silt deposited inside the sewer line of 150mm dia with the help of sewer cleaning equipment and scrappers fitted in nylon wire inserted from one manhole to next removing floated matters and silt collected in the lower manhole conveying and carrying the same in suitable places as directed by deptl officers including cost of oil, carbolic soap, phenyl and hire charges for the bucket and other tools etc. complete |
| 63 | OD245795/2025-2026:Cleaning 200mm line with cleaning rod- Cleaning the silt deposited inside the sewer line of 200mm dia with the help of sewer cleaning equipment and scrappers fitted in nylon wire inserted from one manhole to next removing floated matters and silt collected in the lower manhole conveying and carrying the same in suitable places as directed by deptl officers including cost of oil, carbolic soap, phenyl and hire charges for the bucket and other tools etc. complete |
| 64 | OD245791/2025-2026:Manhole cleaning up to 3 m depth- Cleaning the manhole at main line and branches up to a depth of 3 m including removing the silt and other floated matters and destroying the debries at convenient places as directed by departmental officers |
| 65 | 16.83:Taking out existing CC interlocking paver blocks from footpath/ central verge, including removal of rubbish etc., disposal of unserviceable material to the dumping ground, for which payment shall be made separately and stacking of serviceable material within 50 metre lead as per direction of Engineer-in-Charge. |
| 66 | OD245793/2025-2026:Laying 80 mm thick factory made cement concrete interlocking paver block of M - 30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and EXCLUDING 50 mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in-charge |
| 67 | 50.17.1.4:Supplying and fixing CP Health faucet good quality including cost of materials and labour charges etc. complete as per the direction of site engineer-in-charge. |
| 68 | 17.28.2.1:Flexible pipe32 mm dia |
| 69 | 26.28.3:Chipping of unsound/weak concrete material from slabs, beams, columns etc.with manual Chisel and/ or by standard power driven percussion type or ofapproved make including tapering of all edges, making square shoulders ofcavities including cleaning the exposed concrete surface and reinforcementwith wire brushes etc. and disposal of debris for all lead and lifts all completeas per direction of Engineer-In-Charge25 mm average thickness |
| 70 | OD245800/2025-2026:Providing and Replacement of Flush Tank Syphon Kit Full Se |
| 71 | 13.115:Varnishing with flatting varnish of approved brand and manufacture one or more coats on old work. |
| 72 | 100.47.1.4:Leak rectification work in 63mm uPVC (Class 2 to 6) pipeline including detecting and locating leak, earthwork excavation in all kinds of soil for exposing leak portion of the pipe including tar cutting / concrete cutting, cutting the pipe diametrically perpendicular to the axis of pipeline without causing any damages to the remaining portion, dismantling and lifting the pipe from trenches, smoothening the cut ends, conveying the new pipe to the site, cutting and lowering new pipe into the trenches, placing in position, aligning the pipe to line and level and jointing the new pipe with the existing pipe with solvent cement or any available joint and testing the pipeline by operating the valves concerned, and rectifying the defects if noticed and without causing any damages to the existing utilities and refilling the trenches using excavated earth in layers not exceeding 20cm depth including consolidating each layers by ramming, watering, charges for removing surplus soil from work site, including hire for tools and plant, conveyance of tools and materials, bailing out water, providing caution boards, lighting, watching, ribbon fencing, traffic controlling etc., complete as per the direction of Departmental officers including the cost of pipe and uPVC specials; uPVC Pipes and specials shall be of good quality and conforming to relevant standards: All Socketed Jointing. |
| 73 | 100.47.1.5:Leak rectification work in 75mm uPVC (Class 2 to 6) pipeline including detecting and locating leak, earthwork excavation in all kinds of soil for exposing leak portion of the pipe including tar cutting / concrete cutting, cutting the pipe diametrically perpendicular to the axis of pipeline without causing any damages to the remaining portion, dismantling and lifting the pipe from trenches, smoothening the cut ends, conveying the new pipe to the site, cutting and lowering new pipe into the trenches, placing in position, aligning the pipe to line and level and jointing the new pipe with the existing pipe with solvent cement or any available joint and testing the pipeline by operating the valves concerned, and rectifying the defects if noticed and without causing any damages to the existing utilities and refilling the trenches using excavated earth in layers not exceeding 20cm depth including consolidating each layers by ramming, watering, charges for removing surplus soil from work site, including hire for tools and plant, conveyance of tools and materials, bailing out water, providing caution boards, lighting, watching, ribbon fencing, traffic controlling etc., complete as per the direction of Departmental officers including the cost of pipe and uPVC specials; uPVC Pipes and specials shall be of good quality and conforming to relevant standards: All Socketed Jointing. |
| 74 | OD245805/2025-2026:Supplying pumps of good quality ISI make, servicing and maintenance of pump sets, fixing of automatic cut off valves etc. as per the direction of departmental officers |
| 75 | OD245804/2025-2026:Servicing and maintenance of Air Conditioners |
| 76 | OD245796/2025-2026:Supplying & Fixing 20W LED Tube light Philips/Havels |
| 77 | OD245797/2025-2026:Supplying and fixing 1200mm Ceiling fan make off Havels/crompton |
| 78 | OD245798/2025-2026:Supplying Pedestal fan make off Havels/crompton |
| 79 | OD245808/2025-2026:Sweeping and cleaning floors and rooms of the KWA Guesthouse Old block, New block, Dblock including lobby, corridors ,staircase using standard cleaning liquid material(Lizol/Domex approved by the departmental officer) and wipe out floors on daily basis including cleaning carpet,door mat, Separating,transporting and disposing of bio waste and plastic waste to corporation approved licensed agencies, as per the direction of departmentalofficers and strictly according to Green protocol guidelines .(750m2) .Waste should be cleared from the Guest House Premises. |
| 80 | OD245807/2025-2026:Cleaning Closet ,washbasin,tiled wall and Floors of toilets in the KWA Guest house usingstandard cleaning liquid material (Harpic/Domex or equally good make as per the approval of departmental officers) not local make, refreshing daily with deodorants ,Providinggood quality hand wash of standard companies not local make, Air pocket, hair oil sachet and good quality shampoo sachet,, hair oil sachet etc and wipe out floors on daily basis including cleaning as per the direction of responsible departmental officescarpet,door mat,Separating ,transporting and disposing of bio waste and plastic waste as per thedirection of departmental officers.(750m2) .Waste should be cleared from the Guest HousePremises strictly as per green protocol guidelines to licensed corporation agencies like Harithakarmasena only.. |
| 81 | OD245810/2025-2026:Sweeping and cleaning the premises of the KWA Guest house and MD Quarters and the near by quarters premises, tunnel entrance portion behind IB etc. as per the direction of departmental officers, other buildings inside the IB campus buildings including Separating ,transporting and disposing of bio waste and plastic waste as perthe direction of departmental officers.(750m2) .Waste should be cleared from the Guest HousePremises. , garbages debris form the premises etc twice in day for one year including cost oflabour hire charges of equipments conveyance etc. All waste disposal should be strictly based on green protocol guidelines and the waste should be handed over to only corporation licensed agencies like Harithakarma sena strictlyas per the directions of the responsible departmental officer. |
| 82 | OD245813/2025-2026:Washing windows curtain cloths including cost for labour for removing from rods carefully andre fixing after washing and ironing hire charges of tools and equipments, conveyance,current,laundry etc, complete once in three months as instruction of departmental officers |
| 83 | OD245806/2025-2026:Cleaning of ceiling,Pedestal and wall mounted fans and lights ,window glass, ventilator, glassand aluminium nova pan partitions window grills, etc once in a month.. including cost ofcleaning materials such as liquids, glass cleaner, hire charges of ladder and equipmentwhere ever required etc.. complete. |
| 84 | OD245801/2025-2026:Sweeping and Cleaning the terrace and sunshade of the guest house and clearing the waste strictly as per green protocol guidelines through licensed agencies of Corporation like Harithakarmasena etc. as per the direction of departmental officers. |
| 85 | OD245803/2025-2026:Changing bed sheet and pillow covers when new comer arrives including washing and ironingthe changed bed sheet and pillow cover in laundry |
| 86 | OD245802/2025-2026:Collecting, separating ,transporting of bio waste and non bio waste and disposing through the Corporation licensed agencies like 'Harithakarmasena' etc. only as per the direction of departmental officers. Bio gas plant feed (only) may be fed to the installed biogas plant if the plant is in working condition only and as per the capacity of the plant as per the direction of respective departmental officers. Waste should be cleared from the Jalabhavan Premises and should be handed over to the Haritha karmasena of corporation office or any other approved agency for collecting waste(Payment will be based on production of valid receipt from licenced corporation agency(like Haritha karmasena) |
| 87 | OD245809/2025-2026:Collection, cleaning drying etc. of all non biodegradable waste from all over the campus and disposal to licenced agency of corporation(like harithakarma sena) as per the direction of departmental officers and green protocol guidelines except scrap materials which can fetch scrap value. such materials are to be disposed off to various other Government agencies or such agencies as directed by the departmental officers etc. complete. |
| 88 | OD245812/2025-2026:Supplying and fixing ,dismantling existing worn out wiring, rewiring, Regulator, Capacitor, Modular switches, Sockets, Modular plate, Cables including cost of all materials and labour charges as per the direction of departmental officers. |
| 89 | 50.6.1.4:Solid block masonry using pre cast solid blocks (Factory made) of size 30x20x20cm or nearest available size confirming to IS 2185 part I of 1979 for foundation and plinth with thickness 20cm and above in: CM 1:6 ( 1 cement : 6 coarse sand ) etc complete |
| 90 | 100.7.1:Bailing out water with 5HP engine and pump set including conveyance to the site, erecting, dismantling and taking back of engine and pump, cost of fuel lubricating oil and other stores pay of staff etc., complete. |
| 91 | 100.47.2.2:Leak rectification work in 110mm uPVC (Class 2 to 6) pipeline including detecting and locating leak, earth work excavation in all kinds of soil for exposing leak portion of the pipe including tar cutting / concrete cutting, cutting the pipe diametrically perpendicular to the axis of pipeline without causing any damages to the balance portion, dismantling and lifting the pipe from trenches, smoothening the cut ends, conveying the new pipe, cutting and lowering new pipe into the trenches, placing in position, aligning the pipe to line and level and jointing the new pipe with the existing pipe with solvent cement or repairable joint and testing the pipeline by operating the valves concerned, and rectifying the defects if noticed and refilling the trenches in layers not exceeding 20cm depth including consolidating each layers by ramming, watering, charges for removing surplus soil from work site, without causing any damages to the existing utilities, including hire for tools and plant, conveyance of tools and materials, bailing out water, providing caution boards, lighting, ribbon fencing, watching, traffic control etc., complete as per the direction of Departmental officers, including the cost of pipe & specials but excluding the cost of C.I.R. Joints; uPVC Pipes and specials shall be of good quality and conforming to relevant standards: Socket & C.I.R. Jointing. |
| 92 | OD289197/2025-2026:Supplying and fixing 32mm PVC Valve |
| 93 | OD289201/2025-2026:Suppply and Fixing 25mm PVC valve |
| 94 | OD289603/2025-2026:Providing and fixing Aluminium door closer(ARCHIS B-16) includingnecessary fittings, labour charges etc . |
| 95 | 2.6.1:Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge.All kinds of soil |
| 96 | OD289604/2025-2026:Providing and fixing Aluminium door stopper including necessary fittings, labour charges etc . Please Enable Macros to View BoQ information |