| 1 | Note :- (i) The subject work is comparising of day to day complaint complaint nature of works. The contactors trade men should report to E/M complaint cell daily and take complaint from concren JE E/M and after attending complaint he should give feedback and return the complaint slip to concern JE E/M in the evening at 17.30 Hrs on same day. (ii) Tradesman deployed for work should wear proper uniform with full shirt and full Pant. Colour code will be decided by EIC. (iii) For any minor repair required in distribution system where the item under repair is to be replaced, contractor has to identify and recitified the fault without any extra cost. (iv) Contractor must ensure a stock of 25% of total qty as catered in CA or 25% of balance qty of the item as catered in CA (during currency of contract) at the MES provided store. If the contractor not provided said above, recovery shall be made as per Terms and Condition of the contract as specified in particular specification. However no ‘Advance on Account’ against this provision as material laying at site shall be admissible.(v) All LED lights/ flood lights shall be properly connected with earth dolly provided with fittings and earth connection.(vi) All LED lights have replacement warranty of 3 years from the date of completion of the contract, accordingly condition 46 of GCC (IAFW-2249) shall be amended to extent mention above. Contractor has to submitt warranty certificate from manufacturer . Payment of light fitting will be released after receiving of 3 year replacement warranty certificate.(vii) The LED lights will replaced by the contractor free of cost in the case of manufacturing defects and defects covered in standard warranty policy.(viii) The contractor shall submit the surge protection certificate and type test certificate LM 79, LM 80 for luminaries.(ix) All LED fitting shall be identified by printing or fixing sticker duly mentioned the CA number and date of completion.(x) For any change in product or change in catalogue No. etc due to technological up gradation, letter has to be obtained from the lighting company on their letter head signed by an official of National level.(xi) All T&P required at site for installation of light on Bldg/ hanger or at any location shall be arranged by contractor. |
| 2 | Rate quoated of all items here in below inclusive provision as under (a) Provision and maintenance of all tools, plants, equipment and safety gear required for tradesmen under this contract (b) Provision of communication facilities to supervisor and tradesmen. (d) Monitoring and management of complaints report from generation to execution of complaint including pending complaints. (e) Updating status of lodged complaints before change of eight hour shift. (f) Provision of motorized conveyance for deployment to all tradesmen under this contract. (g) Basic inputs to be noted from the complainants will be locality, Building No, Qtr No, Name and Rank of complaint and exact nature of complaint and mobile No/ telephone or based on inputs provided . |
| 3 | Excavating in trenches , n.exc 1.5 m wide and n.exc 1.5 m depth for foundation etc or for shafts, wells, cesspits ,manhole pier hole etc n.exc 10 sqm on plan and n.exc 1.5m in depth and getting out in any kind of soilNote : Manual excavation to be done. During excavation if any damage occured to existing cable any type/ water pipe line, it will be contractor responsibilty to get it repair and make functional by providing jointing kit etc without any extra cost. Contractor has to repair it within 24 hrs so that essential service can not be effected due to such damage.If contractor fails to repair it within 24 hrs penalty @ Rs 500/- will be charged to contractor. In this GE decision will be final, conclusive and binding. |
| 4 | Returning filling in including spreading levelling watering and well ramming in layers not exceeding 25 cm in thick using excavated hard/dense soil Complete all as specified and directed. |
| 5 | Removal of surplus soil to a distance not exceeding 50 m and depositing where directed by Engr-in-charge Complete all as specified and directed. |
| 6 | M&L Sand Cushioning (dry) in trenches for protection of UG Cables (below, above and around the UG Cable laid in Trenches) of 230mm Spread thickness and consolidated (punned) upto 180mm thickness, complete all as specified and as directed. (NOTE : For the purpose of Payment, Punned thick-ness of Sand Cushioning only shall be Measured and Paid ) |
| 7 | Supply and laying Flyash Bricks , locally available best quality (sub class \\"B\\" bricks) laid in trenches perpandicular to U/G cable for cable protection complete all as specified. |
| 8 | Disconnecting & taking out defective under ground LT cable from trenches, pole, pipe, floor ,wall etc including bricks ,GI pipes and removing from work site of unserviceable material all as specified and directed.(Excavation/earth work shall be measured & paid separately under relevant item of this schedule) |
| 9 | Supply, Laying and testing cable LT XLPE sheathed,PVC insulated screened PVC bedded,galvanised steel strip of wire armoured electric power cable heavy duty with solid aluminium conductor 1100 volt grade, laid in trenches/surface of wall/in GI pipe along with pole for connection to OH lines,including brass cable glands,clamps,etc of 2 core 10 sqmm Complete all as specified and directed. |
| 10 | Supply, Laying and testing cable LT XLPE sheathed,PVC insulated screened PVC bedded,galvanised steel strip of wire armoured electric power cable heavy duty with solid aluminium conductor 1100 volt grade, laid in trenches/surface of wall/in GI pipe along with pole for connection to OH lines,including brass cable glands,clamps,etc of 4 core 10 sqmm Complete all as specified and directed. |
| 11 | supply laying or Fixing or Passing through Pipe, XLPE insulated, Armoured, Electric Power UG Cable (Heavy Duty) with Aluminium Conductor, 1100 Volt Grade, Nominal Cross-Sectional Area 16 sqmm 2 core and Testing, including Brass Compression Cable Gland, Terminal Lug, etc. complete all as specified and as directed Complete all as specified and directed. |
| 12 | Supply, Laying and testing cable LT XLPE sheathed,PVC insulated screened PVC bedded,galvanised steel strip of wire armoured electric power cable heavy duty with stranded aluminium conductor 1100 volt grade, laid in trenches/surface of wall/in GI pipe along with pole for connection to OH lines,including brass cable glands,clamps,etc of 4 core 16 sqmm Complete all as specified and directed. |
| 13 | Supply, Laying and testing cable LT XLPE sheathed,PVC insulated screened PVC bedded,galvanised steel strip of wire armoured electric power cable heavy duty with stranded aluminium conductor 1100 volt grade, laid in trenches/surface of wall/in GI pipe along with pole for connection to OH lines,including brass cable glands,clamps,etc of 3.5 core 25 sqmm. Complete all as specified and directed. |
| 14 | Supply, Laying, testing and connecting XLPE sheathed,PVC insulated screened PVC bedded,galvanised steel strip of wire armoured electric power cable heavy duty with stranded aluminium conductor 1100 volt grade of size 4 core 25 sqmm, laid in trenches/surface of wall/in GI pipe along with pole for connection to OH lines, including Brass Compression Cable Gland, Terminal Lugs, clamps, nut & bolts etc including taking down of old unserviceable cable all as specified. |
| 15 | Supply, Laying and testing cable LT XLPE sheathed,PVC insulated screened PVC bedded,galvanised steel strip of wire armoured electric power cable heavy duty with stranded aluminium conductor 1100 volt grade, laid in trenches/surface of wall/in GI pipe along with pole for connection to OH lines,including brass cable glands,clamps,etc of 3.5 core 50 sqmm. Complete all as specified and directed. |
| 16 | Supply, Laying and testing cable LT XLPE sheathed,PVC insulated screened PVC bedded,galvanised steel strip of wire armoured electric power cable heavy duty with stranded aluminium conductor 1100 volt grade, laid in trenches/surface of wall/in GI pipe along with pole for connection to OH lines,including brass cable glands,clamps,etc of 3.5 core 70 sqmm. Complete all as specified and directed. |
| 17 | Supply, Laying and testing cable LT XLPE sheathed,PVC insulated screened PVC bedded,galvanised steel strip of wire armoured electric power cable heavy duty with stranded aluminium conductor 1100 volt grade, laid in trenches/surface of wall/in GI pipe along with pole for connection to OH lines,including brass cable glands,clamps,etc of 3.5 core 95 sqmm. Complete all as specified and directed. |
| 18 | Supply, Laying and testing cable LT XLPE sheathed,PVC insulated screened PVC bedded,galvanised steel strip of wire armoured electric power cable heavy duty with stranded aluminium conductor 1100 volt grade, laid in trenches/surface of wall/in GI pipe along with pole for connection to OH lines,including brass cable glands,clamps,etc of 3.5 core 120 sqmm . Complete all as specified and directed. |
| 19 | S&F Galvanised Iron Pipe 40 mm Bore (dia) ‘Light Grade’ for protection of UG Cable, laid in Floors/ Road Crossing, fixing to Pole with Mild Steel Clamps, Nuts, Bolts, etc., complete all as specified and as directed. |
| 20 | S&F Galvanised Iron Pipe 50 mm Bore (dia) ‘Light Grade’ for protection of UG Cable, laid in Floors/ Road Crossing, fixing to Pole with Mild Steel Clamps, Nuts, Bolts, etc., complete all as specified and as directed. |
| 21 | S&F Galvanised Iron Pipe 80 mm Bore (dia) ‘Light Grade’ for protection of UG Cable, laid in Floors/ Road Crossing, fixing to Pole with Mild Steel Clamps, Nuts, Bolts, etc. complete all as specified and as directed. |
| 22 | M&L for 40mm dia Double Wall Corrugated (DWC) High density polyethylene pipes (HDPE) laid in trenches for cable protection complete all as specified and directed of following sizes. Complete all as specified and directed. |
| 23 | M&L for 50mm dia Double Wall Corrugated (DWC) High density polyethylene pipes (HDPE) laid in trenches for cable protection complete all as specified and directed of following sizes. Complete all as specified and directed. |
| 24 | M&L for 90mm dia Double Wall Corrugated (DWC) High density polyethylene pipes (HDPE) laid in trenches for cable protection complete all as specified and directed of following sizes. Complete all as specified and directed. |
| 25 | Supply & Fixing sheet moulding compound junction box IP 66 weather proof for outdoor installation with knockouts for cable entry suitable for terminating 2 Nos 4 x 10 to 16 Sqmm UG cable including MS clamp with nut and bolt and cable glandes - 2 Nos, and two way terminal all as specified and directed. |
| 26 | M & L Cable jointing kit for 1.1 KV grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 35 to 50 sqmm including dismantling old burnt cable joint termination. Complete all as specified and directed. |
| 27 | M & L Cable jointing kit for 1.1 KV grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 70 to 120 sqmm including dismantling old burnt cable joint termination Complete all as specified and directed. |
| 28 | M & L Cable jointing kit for 1.1 KV grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 185 to 240 sqmm including dismantling old burnt cable joint termination. Complete all as specified and directed. |
| 29 | S & F in repair MCCB 415V 3 phase 50 HZ 4 pole 63 Amps breaking capacity 16 KA complete all as specified and directed by Engr-in-Charge Complete all as specified and directed. |
| 30 | S & F in repair MCCB 415V 3 phase 50 HZ 4 pole 100 Amps breaking capacity 16 KA complete all as specified and directed by Engr-in-Charge Complete all as specified and directed. |
| 31 | S & F in repair MCCB 415V 3 phase 50 HZ 4 pole 200 Amps breaking capacity 36 KA complete all as specified and directed by Engr-in-Charge. |
| 32 | S & F in repair MCCB 415V 3 phase 50 HZ 4 pole 250 Amps breaking capacity 36 KA complete all as specified and directed by Engr-in-Charge. |
| 33 | S & F in repair MCCB 415V 3 phase 50 HZ 4 pole 400 Amps breaking capacity 36 KA complete all as specified and directed by Engr-in-Charge. |
| 34 | M&L for preparation of existing surface of LT Panel by srapping down peeled off old paint, cleaning etc of any size and applying Two coat of Siemens Grey Paint by using spray machine and Black paint on Angle Iron over a coat of red oxide primer complete all as specified and directed by Engr in Charge.Note:- Only external portion shall be painted. |
| 35 | Material and labour for earthing complete with Galvanised steel earth plate electrode 600x600x6 mm mm buried directly in ground (Earth pit not less than 2.25m below ground level) with top edge of the plate not less than 1.5m below normal ground level, connected to GI strip 25 x 4 mm as earth lead by means of bolt, nuts, check nuts and washers of galvanised iron or steel, upto 7.5m length, earth strip protected by and including 40 mm dia GI pipe (md grade) and connected to main test point or body of pole/pannel or lightening arrester of main controlling switch as directed including concrete pit in PCC (1:3:6) type C1 , Precast RCC (1:2:4) Type B1 cover slab of size 54x54x5 cm reinforced with 8 mm dia TMT bars @ 100 mm C/C both ways with one handle for lifting made out of 10 mm dia TMT bar embedded in precast cover slab, funnel, wire mesh, 20 mm bore GI Pipe (Medium Grade) for watering, Charcoal and salt in alternate layers of 15 cm (Compacted Thickness) around the earth electrode including necessary excavation, earth work in any type of soil and disposal of spoil to a distance n.exc 50 m and necessary testing complete all as shown in Electrical Plate No 3 of SSR Part-I. NOTE : 1. The unit rare includes for protectionh GI pipe of 40mm and watering pipe of 20mm bore including excavation for earth pit in any type of soil/disintegrate rock. 2. Contractor has to bring agriculture soil from outside of defence land and fill in earth pit to acheive desired result as the soil resisitivity is very high. 3. The cost of GI strip including protection pipe, from top of earth plate upto 7.5 meter above/below ground level is deemed to be included in the unit rate. 4. All the joints in GI strip and connectgion with earth plate to be welded through brazing and in addition by providing double brass nut bolt and washer. 5.Costing of welding and nut bolts are deemed to be included in the unit rate. Complete all as specified and directed. |
| 36 | Supply,designing ,install, testing & commission 3 phase and neutral, 415 volts outdoor type, CPRI type tested having certification of IEC-61439 , factory made , dust and vermin proof, cubical type LT panel of size 1.20m x 0.45m x 1.20m, with canopy fabricated from 3.00 mm thick CRCA sheet for outer shell and 2 mm thick for non load bearing with angle iron frame of 50 x 50 x 6 mm, double door, front and back openable type, double door system, hinged opening, rubber lining, locking arrangement, with anticorrosive coating and finally epoxy polyester power coating with pure polyster Siemens grey structural RAL-7032 shade, protection class IP-66 fully compartmentalize design with 4 Nos of bus bar made of copper 400 Amps rated (electrical grade aluminium complying with the requirements of latest BIS, colour coded), busbar extensions for cable connections of electrolytic grade . The busbars and Interconnecting links shall be insulated with heat shrinkable PVC sleeve with RYB & black colour coding. The bus bars shall be supported on unbreakable, non-hygroscopic SMC insulated pre-wired with suitable size of copper strip/copper wire with colour code for connecting out going MCCB/MCB's, including suitable aluminium earth strips conforming to IS with danger notice plate, necessary cable glands, cable connection with proper lugs, making electrical connection and circuit wiring for street light auto ON/OFF control timer by using desired electrical parameters PCC foundation and pedestal for fixing pillar feeder box/LT Panel with PCC 1:3:6, 15 cm thick in foundation, brick (Fly ash) / PCC block work in CM 1:6, rendering 1:6 on exposed surface and 100 mm thick PCC 1:3:6 type C1 using 20 mm graded stone aggregate as in padding on top and grounting bolts etc for panel. The platform shall be of 450 mm height above ground level all as specified with supply and fixing the following accessories including taking out the existing one : |
| 37 | (A) IncomingMCCB 250 Amps rating, FP ,415 V, AC, 50 HZ, adjustable thermal anf fixed magnetic setting Ics-100 % Icu , service breaking capacity 36 KA --- 01 Nos(B) Outgoing(b) MCCB 100 Amps rating, FP ,415 V, AC, 50 HZ, adjustable thermal anf fixed magnetic setting Ics-100 % Icu , service breaking capacity 16 KA --- 04 Nos.(c) (b) MCCB 63 Amps rating, FP ,415 V, AC, 50 HZ, adjustable thermal anf fixed magnetic setting Ics-100 % Icu , service breaking capacity 16 KA --- 01 Nos.(d) Digital voltmeter 0-500 volt with selector switch -01 No e) Digital amp meter 0-100 Amp with set of current transformer of suitable rating and selector switch -01 No (f) Indicator lamp (RYB) LED type - 01 set(g) Control MCB 2.0 Amps SP- 03. Nos Note:- (i) All MCCB/MCB should be of approved Make (ii) Drawing of LT panel and make of items shall be get approved from GE before ordering the panel.(iii) Cost of lugs for cable and cable gland etc also included in unit rate of panel.(iv) The rating bus bar to out going MCCB / MCB`s shall not be less than 1.5 times the rated current of individual out going feeders/ MCCB. (v) Spreader terminals and Phase barriers to be provided with all MCCB`s (vi) Rate of panel include refixing of all cables in panel which are dismantle & taking out from old unserviceable panel. |
| 38 | All as per BOQ Item No 36.00 here-in-before but of size 1.00m x 1.00m x 0.45m with the following incoming and outgoing accessories :-(A) IncomingMCCB 200 Amps rating, FP ,415 V, AC, 50 HZ, adjustable thermal anf fixed magnetic setting Ics-100 % Icu , service breaking capacity 36 KA --- 01 Nos. (B) Outgoing(b) MCCB 100 Amps rating, FP ,415 V, AC, 50 HZ, adjustable thermal anf fixed magnetic setting Ics-100 % Icu , service breaking capacity 16 KA --- 02 Nos.(c) MCCB 63 Amps rating, FP ,415 V, AC, 50 HZ, adjustable thermal anf fixed magnetic setting Ics-100 % Icu , service breaking capacity 16 KA --- 02 Nos(e) Digital voltmeter 0-500 volt with selector switch -01 No (f) Digital amp meter 0-100 Amp with set of current transformer of suitable rating and selector switch -01 No (g) Indicator lamp (RYB) LED type - 01 set(h) Control MCB 2.0 Amps SP- 03. Nos |
| 39 | M & L Painting of steel pole (swan neck type or straight type) up to 12 mtr height with cross arms, clamp of any length and shape for LT overhead line/ for street light with two coat of aluminium paint after scraching out old paint, cleaning and exiting surface rust free, preparation of the existing surface, including marking pole numbers in a 15 cm dia yellow circle with number writting with black syenthic paint/ Stricker, including painting strips in alternate from top of coping upto 1.50m height with three strips of black syenthatic paint & two strips of Yellow/ Sky blue paint (as per existing pattern) through out the circumference of pole, including removing extra wall papdi ,peel off wall papdi by sand paper and making good with putty as per existing thickness and applying one coat of white washing on PCC copping of pole and re-numbering of pole with approved size of letter ( Example - P- 001) with synthetic enamel paint of white colour background and black colour lettering complete all as specified and as directed. |
| 40 | M & L Painting of concrete up to 12 mtr height coat of weather coat paint after scraching out old paint, cleaning and exiting surface preparation of the existing surface, including marking pole numbers in a 15 cm dia yellow circle with number writting with black syenthic paint/ Stricker, including painting strips in alternate from top of coping upto 1.50m height with three strips of black syenthatic paint & two strips of Yellow/ Sky blue paint (as per existing pattern) through out the circumference of pole, including painting to angle iron cross arms channels clamps and street light brackets with aluminium paint including removing extra wall papdi ,peel off wall papdi by sand paper and making good with putty as per existing thickness and applying one coat of white washing on PCC copping of pole and re-numbering of pole with approved size of letter ( Example - P- 001) with synthetic enamel paint of white colour background and black colour lettering complete all as specified and as directed. |
| 41 | M&L for manual boring under road crossing and laying pipe across the road for laying cables complete all as specified and as directed. |
| 42 | M & L for relaying of LT UG Cable connecting XLPE sheathed,PVC insulated screened steel strip of wire armoured electric power cable heavy duty with stranded aluminium conductor 1100 volt grade of any size, laid in trenches/surface of wall/in GI pipe along with pole for connection to OH lines,including Brass Compression Cable Gland, Terminal Lugs,clamps,nut & bolts etc all as specified |
| 43 | Taking down defective street / security/flood lights/post top/high mast lanterns or any other external lights from its original position fixed on pole / building structure, opening the cover and testing all the compenents / parts, wiring etc, identifying and replacing the defective components like electronic driver (in case of LED lights), Bulb holder, connector, connection wires/ cable, carrying out necessary repair work and reassembling the same including refixing the serviceable fittings to its original position by providing new nut & bolts, copper lugs and replacement of connection cable if required including cleaning of creepers on/around the pole/light fitting/Gate light fitting etc all as directed by Engr-in-charge . Note: (i) The rate against the above mentioned item is deemed for cost of labour and allied expenses only. (ii) Cost of spares like electronic driver, LED lamp lamp holder, connector, connection wire, MCB, timer spares etc) will be measured & paid separately under respective items of Sch 'A' here-in-below as supply only. |
| 44 | Supply only the followings (To be measured only when incorporated against item No 42.00 here-in- before). Complete all as specified and directed. |
| 45 | FRLS PVC insulated copper conductor, Three core, for street light from box to Street light of 1.5 sqmm size complete. Complete all as specified and directed. |
| 46 | FRLS PVC insulated copper conductor, Three core, for street light from box to Street light of 2.5 sqmm size complete. Complete all as specified and directed. |
| 47 | M&L Street Light Fittings Bracket, fabricated from GI Pipe 40mm Bore (dia), Light Grade, 1.00 meter long, bend to required shape and fixing with and including Mild Steel Flat Iron Clamps 40X5mm of suitable Length, 2 No. Nuts, Bolts, Washers, etc., to Pole, applying Painting with One Coat of Red Oxide Zinc Chrome Primer and over Two Coats of Aluminium Paint to Mild Steel Works including Taking down old unserviceable Street Light Fittings Bracket, complete all as specified and as directed. Please Enable Macros to View BoQ information |
| 48 | M&L Street Light Fittings Bracket, fabricated from GI Pipe 40mm Bore (dia), Light Grade, 1.00 meter long, bend to required shape and fixing with and including Mild Steel Flat Iron Clamps 40X5mm of suitable Length, 2 No. Nuts, Bolts, Washers, etc., to Pole, applying Painting with One Coat of Red Oxide Zinc Chrome Primer and over Two Coats of Aluminium Paint to Mild Steel Works including Taking down old unserviceable Street Light Fittings Bracket, complete all as specified and as directed. Please Enable Macros to View BoQ information |