| 1 | Surface excavation (n exc 30cm deep) and averaging 15 cm, getting out in hard/ dense type of soil all complete all as specified and directed. |
| 2 | Demolition of concrete in ground floors and pavings n exe 15 cm thickness (below or above ground level), complete all as specified and directed. |
| 3 | M&L for hardcore of gauge exc 63mm but n exc. 100 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rolled/ rammed to a true surface, complete all as specified and directed. |
| 4 | Excavation in trenches for foundation etc n exc 1.5m wide and n exc 1.5 m in depth in hard/ dense soil any type of soil complete all as specified and directed. |
| 5 | Returning filling in including spreading leveling, watering and well ramming in layers n exc 25cm thick complete all as specified and directed. |
| 6 | Removal of excavated material to a distance n exc 50 m and depositing at a level n exc 1.5 m above the starting point complete all as specified and directed. |
| 7 | M&L for PCC 1:4:8, type D-2, using 40mm graded crushed stone aggregate as in foundation, filling, sub base and mass concrete, complete all as specified and directed. |
| 8 | M&L for reinforced cement concrete M-30 (Design Mix) using 20mm graded crushed stone aggregate as in foundations, including rafts, footings, foundation beams, plinth beams, bases for columns, etc., basement slabs, under-reamed piles and mass concrete complete all as specified and directed. |
| 9 | M&L for reinforced cement concrete M-30 (Design Mix) using 20mm graded crushed stone aggregate as in columns, pillars, piers, posts and struts complete all as specified and directed. |
| 10 | M&L for reinforced cement concrete M-30 (Design Mix) using 20mm graded crushed stone aggregate as in beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and directed. |
| 11 | M&L for reinforced cement concrete M-30 (Design Mix) using 20mm graded crushed stone aggregate as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed. |
| 12 | All as per Srl Item No 11.00 as above but in chajjas complete all as specified and directed. |
| 13 | Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams, and similar work, vertical or to batter flat rough finished complete all as specified and directed. |
| 14 | Formwork to sides of pillars, posts, struts piers, columns and stanchions flat rough finished complete all as specified and directed. |
| 15 | Formwork to sides and soffits roof beams, lintels flat finished rough, complete all as specified and directed. |
| 16 | Formwork as in chajjas flat finished rough complete all as specified and directed. |
| 17 | M&L for TMT steel bars 10mm dia and over cut to length bent to shape reqd incl cranking bending spirally for hooping for columns hooking ends and binding with m.s wire annealed not less than 0.9mm dia complete all as specified and directed. |
| 18 | M&L for mild steel TMT bars of 6mm to 8mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia, complete all as specified and directed. |
| 19 | S&F for rolled mild steel framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. doors, etc. to be prepared for hanging or sliding with complete all as specified and directed. |
| 20 | M&L for 1.25mm thick mild steel, plain, black sheet in wall cladding, steel gates and similar work, cut to size, holes punched, including round headed screws, clout nails or rivets and fixed to wood or steel framing with plain 40 mm lap joints with riveted or welded seams, including bending or turning up, mitered angles, etc. as required complete all as specified and directed |
| 21 | M&L for brick work with sub class 'B' bricks in straight or curved on plan exc 6m mean radius, built in CM 1:4 complete all as specified and directed |
| 22 | M&L for rendering 10mm thick on fair faces of concrete surfaces in ceilings in cement mortar 1:3 and finished fair and even without using extra cement complete all as specified and directed. |
| 23 | M&L for rendering 15 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:6 and finished smooth and even without using extra cement complete all as specified and directed. |
| 24 | M&L for rendering 15 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:4 and incl. mixing water proofing where required @ 2% compound and finished fair and even without using extra cement complete all as specified and directed. |
| 25 | Supply only integral water proofing compound complete all as specified and directed. |
| 26 | M&L for preparing newly plastered surfaces of ceilings and applying three coats of white wash complete all as specified and directed. |
| 27 | M&L for preparing new plastered surfaces and applying two coats of cement base paint on surfaces of walls complete all as specified and directed. |
| 28 | M&L for preparation of newly plastered surfaces of walls and applying two coats of oil emulsion distemper after preparation of surfaces complete all as specified and directed. |
| 29 | M&L for 25 mm thick PCC 1:2:4, type B-0, using 12.5mm graded crushed stone aggregate as in sub base floor finished even & fair without using extra cement complete all as specified and directed. |
| 30 | M&L for 100mm thick cement concrete 1:4:8, type D-2, using 40mm graded crushed stone aggregate as in sub base of floor, complete all as specified and directed. |
| 31 | S&F factory made uPVC white colour three track three panels sliding window with fly proof S.S wire mesh (Two nos glazed & one no. wire mesh panels) upto 1.50m height made of (big series) frame 116 x 45 mm & sash 46 x 62 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of window above 1.75 sqm) comprising of uPVC multichambered frame, with inbuilt roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitered cut and fusion welded at all corners, including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weatherproof silicon sealant over backer rod of required size and of approved quality, complete all as specified and directed Note: (i) Glass or wire mesh shall be measured and paid separately.(ii) For uPVC frame and sash extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. |
| 32 | M&L for machine cut kota stone slab 18 to 22 mm thick of size not less than 550mm x 550mm in floor, set and jointed in neat cement slurry with grey cement mixed with pigment to match the shade of the slab including rubbing and polishing (granite finish) over and including 15 mm thick screed bed in CM 1:4 complete all as specified and directed. |
| 33 | M&L for machine cut kota stone slab 18 to 22 mm thick ( kota stone shall be cut from size not less than 550mm x 550mm) in skirting , set and jointed in neat cement slurry with grey cement mixed with pigment to match the shade of the slab including rubbing and polishing (granite finish) over and including 10 mm thick rendering in CM 1:4, complete all as specified and directed. |
| 34 | M&L for Glazed coloured ceramic tiles in vertical surface 300x600x7mm thick set and joint in neat cement slury over 10mm thick plaster of CM 1:4 and pointed in white or colour cement to match, complete all as specified and directed. |
| 35 | M&L for 16 to 18 mm thick granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite over and including 15mm thick rendering in CM 1:4 complete all as specified and directed. |
| 36 | M&L for providing 75 mm thick cement concrete 1:3:6, type C-1, using 20mm graded crushed stone aggregate as in plinth protection laid in alternate bays (n. exc. 2 Sqm each) and finished even and smooth without using extra cement and providing joints throughout the thickness of the plinth protection filled with mastic filling comprising one part of bitumen 85/25 grade and three parts of sand by weight complete all as specified and directed. |
| 37 | M&L for preparation of new steel and iron surfaces exceeding 10 cms width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed. |
| 38 | S&F steel windows or ventilators, fixed type, with glazing bars complete all as specified and directed. |
| 39 | M&L for 4.8 mm thick frosted glass fixed to aluminium frame including rubber bead complete all as specified and directed. |
| 40 | S&F galvanised mild steel wire cloth 0.56mm nominal dia of wire and avg width of aperture1.18mm complete all as specified and directed. |
| 41 | M&L for cutting chases, pinning in making good to facing where required and pointing in CM 1:3 to edges of landing, steps, cills, sunshades, shelves, lintel etc. and cutting chases for concealed water tubing etc and making good cutting n. exc 10 cm girth, complete all as specified and directed. |
| 42 | S&F pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.60mm thick having zinc coating 150 grams per Sqm (Az 150) of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws, complete all as specified and directed. |
| 43 | S&F pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa having zinc coating 150grams/Sqm (Az-150) as in roof covering/cladding to wall, fixed with self tapping screws, complete all as specified and directed. |
| 44 | S&F rolled mild steel work in roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. of Fe-410-W (Grade-E-250) quality-A, complete all as specified and directed. |
| 45 | S&F for rolled mild steel in plates channels (plain or chequered), square cut or notched (ordinary and counter sunk) forming holes, without any attachment, Fe 410-W (Gde- E- 250) quality-A, complete all as specified and directed. |
| 46 | S&F mild steel rag or lewis bolts, screwed one end, with hexagonal or square nuts and washers, the other end enlarged and jagged or lewised, exc 30cm long and 12mm dia. of neck, complete all as specified and directed. |
| 47 | M&L for PCC 1:3:6, Type C-2, using 40mm graded crushed stone aggregate as in surface channels and drains complete all as specified and directed . |
| 48 | Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitered/ stopped ends etc., complete all as specified and directed. |
| 49 | S&F false ceiling with semi perforated 12 mm thick micro tegular edged at all heights with GRG (glass fiber reinforced gypsum) false ceiling tiles of size 595x595mm of approved texture, design and pattern having moisture content less than 2%, humidity resistance of 99%, NRC 0.5 to 0.75 as per IS 8225-1987, non- combustile as per BS475 (part-4) -1970 and light code description unit rate No.429 SUB HEAD:26.0 new technologies and material reflectance of 85% (minimum) to be laid in true horizontal level suspended on interlocking metal T-Grid of hot dipped galvanised iron section of 0.33mm thick (galvanised @ 120 gms per sqm including both sides) comprising of main -T runners of size 15x32mm of length 3000mm, cross T of size 15x32mm of length 1200mm and secondary intermediate cross-T of size 15x32mm of length 600 mm to form grid module of size 600x600mm, suspended from ceiling using galvanised mild steel items (galvanising @80 gms per sqm) i.e. 50mm long, 8 mm outer diameter M-6 dash fasteners, 6mm dia fully threaded hanger rod upto 1000mm length and L-Shape level adjuster of size 85x25x2mm. Galvanised iron perimeter wall angle of size 24x24x0.4mm of length 3000mm to be fixed on periphery wall /partition with the help of plastic rawl plugs at 450 mm center to center and 40 mm long dry wall wood screws, complete all as specified and directed. |
| 50 | M&L for machine pressed rubber moulded precast coloured concrete interlocking paver block, any shape and size conforming to IS 15658-2006, ISI marked of 80 mm thickness, grade M-40 with grey cement and pigments over and including a layer of sand cushioning, 25 mm thick complete all as specified and directed. |
| 51 | M&L for PCC 1:2:4, type B-1, using 20mm graded crushed stone aggregate as in coping and the like including weathering slightly rounded or chamfered angles & throating etc., including necessary form work complete all as specified and directed. |
| 52 | M&L for rough cast plaster including 15mm thick rendering in CM 1:3 on brick wall or concrete concrete surfaces complete all as specified in SSR Part - I clause 14.22 complete all as specified and directed. Note : Rough cast finish to be as below :- After applying the under coat of cement mortar 1:3 and while it is still in plastic state the rough cast mixture consisting of crushed stone or fine gravel agg (which is generally of size between 6 to 12mm depending on the texture required) mixed with coarse sand and cement in the ratio of 1:1:1 shall be applied and finished even. The mix of cement and sand shall be made slightly wetter than normal for rendering to ensure that larger agg are thoroughly covered. |
| 53 | Excavating in post holes (or similar holes) each not exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm, watering, and removing surplus soil to a distance not exc 50m and making good surface, work in soft/loose soil, complete all as specified and directed. |
| 54 | M&L for PCC 1:2:4, Type B-2, using 40mm graded crushed stone aggregate as in foundations, filling and mass concrete, complete all as specified and directed. |
| 55 | S&F steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to IS 1161-1979 grade St.-240 complete all as specified and directed. |
| 56 | S&F 11-15mm dia of shank mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, n. exc. 5cm long, complete all as specified and directed. |
| 57 | M&L for preparation of new painted steel surfaces of any description not other wise described over 10cm width or girth and applying two coats of synthetic enamel paint, complete all as specified and directed. |
| 58 | M&L for removing excavated material (soils), exc. 250 m but n exc. 500 m and depositing where directed, complete all as specified and directed. |
| 59 | M&L for lacquer finish chequered cement concrete tiles 30cmx30cmx25mm thick, set, jointed and pointed in neat cement slurry in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15mm thick screed bed in C.M 1:4, complete all as specified and directed. |
| 60 | M&L for hardcore of broken stone or boulders of gauge n exc 63mm, deposited, spread and leveled layes n.exc. 15 cm thick, watered and rammed to a true surface, complete all as specified and directed. |
| 61 | M&L for sand filling 25mm thk, under floors or in foundations including watering and consolidation, complete all as specified and directed. |
| 62 | M&L for taking down cement of cement lime plaster of any description on brick or stone walls etc including ranking out joints hacking for key scrubbing down with water etc complete all as specified and directed. |
| 63 | M&L for preparing new surfaces of walls, plastered or unplastered and applying two coat of oil bound distemper over 2 mm thick putty complete all as specified and directed. |
| 64 | M&L for preparing new surfaces of walls, plastered or unplastered and applying two coats of cement based paint complete all as specified and directed. |
| 65 | Demolition of brickwork or stone/ boulder masonry, built in lime mortar including all quoins, arches, pillars , etc, but excluding ashlar facings, dressed stone-work and precast concrete articles (Demolition) complete all as specified and directed. |
| 66 | M&L for brickwork with subclass `B` bricks, in straight or curved on plan exc 6m mean radius, built in CM 1:6, complete all as specified and directed. |
| 67 | M&L for cutting out concrete blocks, slabs, brickwork or stone masonry (in alternate course), forming toothings and bonding new work in CM 1:4 into old work, including new materials entering old wall PCC 1:2:4, type B-1, using 20mm graded crushed stone aggregate, complete all as specified and directed. |
| 68 | Demolition of concrete of any description and in any position not otherwise specifically provided for complete all as specified and directed. |
| 69 | Demolition of reinforced cement concrete in roofs, floors, beams, chajjas, stair cases, landings and similar suspended work (reinforcement cut as required to facilitate demolition) complete all as specified and directed. |
| 70 | M&L for taking down chowkhat or frame with shutter (without taking off shutters from the frame) area exc 1.50 sqm but not exc 4 Sqm each & removing to store complete all as specified and directed. |
| 71 | M&L for dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed. |
| 72 | M&L for vitrified ceramic tiles light Shade 9/10mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36sqm, in floor etc. set 15mm thick CM 1:4 screed bed and pointed in white or coloured cement to match, complete all as specified and directed. |
| 73 | M&L for Vitrified ceramic tiles light Shade 10mm thick (square/rectangular) polished, area of each tiles not exceeding 0.36sqm, in Skirting etc. set and jointed in neat cement slurry over 10mm thick CM 1:4 and pointed in white or coloured cement to match, complete all as specified and directed. |
| 74 | M&L for 18-20 mm thick granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like in CM 1:4 including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and directed. |
| 75 | Dismantling wall and ceiling boards (fiber, pulp, insulation etc) or insulation boards/ slabs/ blankets, any thickness including cover fillets & electrical wiring, fittings, fitments if any and making good complete all as specified and directed. |
| 76 | M&L for X-ray room anti radiation hermetic (SS-304) stainless steel sliding door of size 900x2100mm of 2mm thick lead lined 40 mm thick shutter door blade and wall frame, incl SS lever handle, sliding track, canopy & wall covering for standard wall thickness with view panel of size 0.30 x 0.30 mtr, complete all as specified and directed. |
| 77 | M&L for concealed point wiring 1.5 Sqmm (nominal cross sectional area) with colour coding multistranded copper conductor cable, PVC insulated (FRLS-H) and unsheathed cable and including drawn through PVC conduit 25mm size with all fittings and accessories, terminated to PVC board of suitable size for housing/mounting the switches/sockets including 1.5 Sqmm PVC insulated unsheathed multistranded copper conductor cable earth wire connected to common earth dolly for one light point control by one, one way switch, complete all as specified and directed. |
| 78 | All as per Srl item No 77.00 above but for one 3 pin socket oulet 5 amps, on independent board, complete all as specified and directed. |
| 79 | All as per Srl item No 77.00 above but for one 3 pin socket oulet 5 amps, on same board with other switches, complete all as specified and directed. |
| 80 | All as per Srl item No 77.00 above but for one 3 pin 15 Amps power point on independent board with 2.5 Sqmm size FRLS-H PVC insulated unsheathed multistranded copper conductor cable and with 2.5 Sqmm FRLS-H PVC insulated unsheathed multistranded copper conductor as earth wire, complete all as specified and directed |
| 81 | S&F switch piano flush single pole, one way 5 Amp ( ISI marked) complete all as specified and directed. |
| 82 | S&F switch piano flush single pole, one way 15 Amp ( ISI marked) complete all as specified and directed. |
| 83 | S&F socket (ISI Marked) 2 in 1, 3 pin 5/6 amps flush type complete all as specified and directed. |
| 84 | S&F socket 2 in 1, 5 pin 5 and 15 amps (ISI marked) flush type universal complete all as specified and directed. |
| 85 | S&F ceiling rose, 3 phase, PVC polycarbonate, insulated body (ISI Marked) complete all as specified and directed. |
| 86 | S&F LED inverter battern tube light along with fixture, 1x 20 watt, (4 Feet) wall mounted LED battern, with diffuser, complete including electrical connection with copper cable from ceiling rose to fittings and including taking down existing fittings and all fixing arrangements complete all as specified and directed. Make: Cat part of HPL: HPLLEDINVT5BPC20CW/ Havells/ Schneider or equivalent as approved. |
| 87 | M&L for lamp holder (Angle) PVC/Polycarbonate type with back plate suitable for batten fittings complete all as specified and directed. |
| 88 | S&F LED 15 watt complete all as specified and directed. |
| 89 | S&F LED building security light 35 watt, 230V AC outdoor type with high pressure die cast aluminium housing and heat resistance complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65 protection fixed on wall complete including electrical connection with copper cable from ceiling rose to fittings and all fixing arrangements complete all as specified and directed. |
| 90 | S & F MCB, SPN (single pole and neutral) 40 Amps for inductive load connected through cable lugs of suitable size complete all as specified and directed. Make: L&T/ Legrand/ Schneider or equivalent as approved. |
| 91 | S&F sheet metal enclosure MCB DB 4 way SPN double door suitable for 240 V, 200 amps rated bus bar/ DIN rail, fixed and flushed on walls including cutting Knitch and making good disturbed surfaces complete all as specified and directed. Make: L&T/ Legrand/ Schneider or equivalent as approved. |
| 92 | S&F MCB, SP (single pole) 05 to 32 Amps, 10 kA, B curve for inductive load connected through cable lugs of suitable size complete all as specified and directed. Make: L&T/ Legrand/ Schneider or equivalent as approved. |
| 93 | S&F MCB, SPN (single pole and neutral) 32 Amps for inductive load connected through cable lugs of suitable size complete all as specified and directed. Make: L&T/ Legrand/ Schneider or equivalent as approved. |
| 94 | M&L for XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 6 sqmm 2 core complete all as specified and directed. |
| 95 | Supply and laying PVC corrugated heavy duty suitable for under ground cable including with all fittings 40mm dia complete all as specified and directed. |
| 96 | M&L for earthing complete with galvanised steel earth plate electrode 60×60cm× 6mm thick, buried directly in ground (earth pit not less than 2.25 meters deep below ground level) with top edge of the plate not less 'than 1.5 meters below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion including galvanised strip protected by 32 mm bore light grade galvanised iron pipe and earth and connected to test point as directed including funnel, watering pipe 20 mm bore light grade galvanised iron wire mesh charcoal and common salt in alternate layers of 15 cm compacted thickness all arround the GI electrode with concrete pit in PCC 1:3:6, type C-1, including necessary excavation in soft/ loose soil and disposal of soil to a distance not exc 50m and necessary testing complete connected to earthing test point, complete all as specified and directed. Please Enable Macros to View BoQ information |