| 1 | Demolition of stone slabs of any description or thickness in floors, aprons, etc laid, bedded and pointed in any mortar and incl removing of debris complete all as specified and as directed. |
| 2 | S&F 18-20 mm thick kota stone as in floors over and including 15mm thick screed bed or bedding layer in cement mortar 1:6 and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing to achieve mirror finish and rounding chamfered edges where complete all as specified and as directed. |
| 3 | All as per item above but 16 to 18mm thick kota stone slab as in small wiidth in vertical surfaces like landings, risers,, treads, skirtings, dado, etc over and including 10mm thick backing coat in cement mortar 1:4 complete all as specified and as directed. |
| 4 | Mirror polishing on Kota stone/stone work where ever required to give high gloss finish complete all as specified and as directed. |
| 5 | M&L 16 to 18mm thick granite stone (of any type ) work (table rubbed and polished) in floors, staircase tread & risers of steps, cooking platform, window cill/jambs etc laid bedded over 15mm thick CM (1:4) bedding & pointed in white/coloured cement to match coloured tiles including Rounding, grinding and mirror polishing complete all as specified and as directed. (Note : Colour of granite shall be as approved by Engr-In-Charge) |
| 6 | Demolition of Brick or stone masonry built in cement mortar all as specified and directed.. |
| 7 | M&L for Pre-cast cement concrete block masonry with solid blocks type C1 (1:3:6) (using 20mm graded crushed stone aggregate) set in CM 1:6, exc. 10 cm in width and setting in mortar, complete all as specified and directed.. |
| 8 | M&L Brickwork with flyash bricks, straight or curved on plan to any radius in half brick thick walls, built in cement mortar 1:4 complete all as specified and as directed. |
| 9 | Demolition of cement concrete (Unreinforced) in ground floors and pavings n exc 15cm thickness (Below or above Ground level) including disposal of material up to 500mtr distance and complete all as specified and as directed. |
| 10 | M & L 75mm thick PCC 1:4:8 type D-2 (using 40mm graded crushed stone aggregate) as in sub base complete all as specified and as directed. |
| 11 | M&L for 75mm thick plain cement concrete in (1:3:6) type C1 using 20 mm graded crushed stone aggregate as in plinth protection finishing cement concrete surface even and smooth without using extra cement complete all as specified and directed. |
| 12 | M&L for providing false ceiling with anodised aluminium snap grid frame work for false ceiling with size of grid 605 x 605mm with aluminium main tee, cross tee size 25x25x1.6 mm and aluminium wall angle size 25x25x1.8 mm fixed to wall hanging from soffits\trusses\bracking using adjustable supporting hanger compressing of GI wire 4mm thick with locking clip including Providing and fixing Non asbestos designer E-Board 4mm thick in ceiling fixed to snap grid as per manufacturers instructions complete including Dismantling of wall and ceiling boards (fibre pulp insulation etc) or insulation boards / slabs /blankets any thickness, including cover fillets complete all as specified and as directed. |
| 13 | Taking down cement plaster on brick or stone masonry wall etc incl racking out joints haking for key, scrubbing down with water etc as in internal and external surfaces of walls etc incl removing of debrie complete all as specified and as directed. |
| 14 | M&L rendering 15mm thick in CM (1:6) on fair faces of brick work or concrete surfaces of walls including finished even and smooth without using extra cement complete all as specified and as directed. |
| 15 | M&L for rendering 5 mm thick on ceiling in CM 1:3 finished even and smooth without using extra cement including Taking down cement plaster from brick or stone walls, ceiling etc complete all as specified and as directed. |
| 16 | M&L rendering 15mm thick in CM (1:4) with water proofing compound on fair faces of brick work or concrete surfaces of walls finished even and smooth without using extra cement including Taking down cement plaster from brick or stone walls, ceiling etc complete all as specified and as directed. |
| 17 | M&L for painting to cement plaster surfaces with two coats of Cement base paint over a coat of alkali resistant primer after preparation of surfacecomplete all as specified and as directed. |
| 18 | M&L for preparing new plastered surfaces of wall and applying two coats of oil bound distemper over 0.8 mm thick wall care putty and a coat of alkali resistant primer complete all as specified and as directed. |
| 19 | M&L preparation of new plastered surfaces and applying three coats of white wash on ceiling surface complete all as specified and as directed. |
| 20 | S&F in repair rotational moulded polyethylene water storage tanks 500 litre capacity incl (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Pt-I including dismantling and taking down existing water tank complete all as specified and as directed. |
| 21 | S&F 25 mm dia gun metal globe or gate valves with iron wheel head screwed both ends for iron pipe as in repairs complete all as specified and as directed. |
| 22 | S&F Ball valves high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe and fixed (minimum weigth 455gms) 20mm bore complete all as specified and as directed. |
| 23 | S&F PVC (SWR) pipes of 110mm dia single socketed in any length including all fittings with rubber ring joints fixed to walls or in floors and tacking down including complete all as specified and as directed. |
| 24 | S&F PVC (SWR) pipes of 75mm dia single socketed in any length including all fittings with rubber ring joints fixed to walls or laid in trenches or in floors and tacking down including complete all as specified and as directed. |
| 25 | Dismantling, floor, hearth or wall tiling including cement mortar bedding but not backing and removing rubbish off the premises including disposal of material up to 500mtr distance and complete all as specified and as directed. |
| 26 | M & L for 25mm thick PCC 1:2:4 type B-0 (using 12.5mm graded crushed stone aggregate) finished fair and even as in sub base flooring complete all as specified and as directed. |
| 27 | M&L for non skid ceramic coloured tiles 7 to 8 mm thick (Square / rectangular) area of each tiles exc 0.11 Sqm but n. exc 0.18 Sqm in floors etc set and jointed in neat cement slurry and pointed in coloured cement to match including 15mm thick screed bed of CM (1:6) bedding complete all as specified and as directed. |
| 28 | M&L for non skid ceramic coloured tiles 7 to 8 mm thick (Square / rectangular) area of each tiles exc 0.11 Sqm but n. exc 0.18 Sqm in skirting etc set and jointed in neat cement slurry and pointed in coloured cement to match including 10mm thick screed bed of CM (1:4) bedding complete all as specified and as directed. |
| 29 | M&L for non skid ceramic coloured tiles 7 to 8 mm thick (Square / rectangular) area of each tiles exc 0.18 Sqm but n. exc 0.38 Sqm in floors etc set and jointed in neat cement slurry and pointed in coloured cement to match including 15mm thick screed bed of CM (1:6) bedding complete all as specified and as directed. |
| 30 | M&L for non skid ceramic coloured tiles 7 to 8 mm thick (Square / rectangular) area of each tiles exc 0.18 Sqm but n. exc 0.38 Sqm in skirting etc set and jointed in neat cement slurry and pointed in coloured cement to match including 10mm thick screed bed of CM (1:4) bedding complete all as specified and as directed. |
| 31 | M&L Glazed ceramic tiles in vertical surface 350x 250x 7 mm/ 450X 350X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match over and including 10mm thick rendering layer in cement mortar 1:4 complete all as specified and as directed. |
| 32 | M & L Non skid ceramic tiles 7 to 8mm thick (square/rectangluar) area of each tile exc 0.06 Sqm but n.exc 0.11 Sqm, in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15mm thick screed bed in CM 1:6 complete all as specified and as directed. |
| 33 | M&L for vitrified tiles dark shade 10mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm as in floors etc. set and jointed in neat cement slurry and pointed in white/ coloured cement, laid over and including cement screed bed 15mm thick in cement mortar 1:6 complete all as specified and as directed. |
| 34 | All as per item No 33 above but as in skirting / dados etc. including backing coat 10mm thick in cement mortar 1:3, complete all as specified and as directed. |
| 35 | M&L for vitrified tiles dark shade 10mm thick (square/ rectangular) polished, area of each tiles exceeding 0.42 Sqm not exceeding 1.00 Sqm as in floors etc. set and jointed in neat cement slurry and pointed in white/ coloured cement, laid over and including cement screed bed 15mm thick in cement mortar 1:6, complete all as specified and as directed. |
| 36 | All as per item No 35 above but as in skirting / dados etc. including backing coat 10mm thick in cement mortar 1:3, complete all as specified and as directed. |
| 37 | S&F in repairs vitreous China squatting pan, `Orissa' pattern, size 580 x440 mm white, with integral foot rests (excluding flushing cistern and flush pipe) complete all as specified and as directed. |
| 38 | S&F in Repairs fancy type bib taps CP brass chromium plated with capstan head, screwed down, screwed for 15 mm bore iron pipe cocomplete all as specified and as directed. |
| 39 | S&F in Repairs Stop valves ,brass chromium plated, fancy type with capstan head screwed down, high pressure, screwed both ends for 15 mm bore iron pipe or for unions complete all as specified and as directed. |
| 40 | S&F in repairs 125 mm dia brass chromium plated shower rose with swivel joints incl concealed stop cock complete all as specified and as directed. |
| 41 | S&F 25 mm bore CPVC pipes SDR 11 pipes & Plain CPVC SDR 11 fittings and fixed complete to walls and ceiling or laid in floors including taking down existing GI/CPVC complete all as specified and as directed. |
| 42 | S&F in repairs of CPVC pipes 20 mm dya SDR 11 & plian CPVC SDR 11 fittings in wall /ceiling or laying in floors taking down existing GI /CPVC pipes complete all as specified and as directed. |
| 43 | S&F in repairs PVC low level flushing cistern 10 ltrs capacity white , with inlet ball valve , float and handle including brackets , Flush pipe of polythylene of low or high density or PVC 32 mm dia , PVC connection 15mm size with PTMT nuts of length 450mm complete all as specified and as directed. |
| 44 | Demolition of cement concrete in any desscription and any position paving exc 15 cm thickness below and above ground level complete all as specified and as directed. |
| 45 | Taking down the plaster incl existing treatment in sunken portion , washing down with water and applying 15mm tick plaster in CM 1:4 with 3% WPC all around incl floors and applying Shaliu Urethane BTD two coats @ 1.5 Kg/Sqm each Coat (Apply 2nd Coat after 6 Hrs) over a coat of Shali Pime WP @ 200gm/sqm and Provide 40mm GI Spout Pipe complete all as specified and as directed.(Note : Supply of water proofing compound will be measured and paid separately.) |
| 46 | Supply only integral water proofing compound complete all as specified and as directed. |
| 47 | M&L for PCC 1:4:8 type D-2 using 40 mm graded stone aggregate as in filling of sunken portion etc complete all as specified and as directed. Please Enable Macros to View BoQ information |