| 1 | M&L for servicing of split type AC 1/1.5/2 TR Capacity including cleaning of cooling coil, air filters/plasma filters etc, (Indoor unit), condenser, compressors, fan motor etc,(Out door unit) with vacuum cleaner OR cleaning solution including checking the serviceability of electrical/electronic circuits relays, wiring kit, thermostat switches knobs, Remote control unit including PCB, fan, blower, etc. & Rectification of water leakage problem due to formation of Ice, leakage of refrigerant keeping the AC unit in satisfactory working condition after necessary servicing complete all specified and directed by Engineer-in-Charge. |
| 2 | S&F in repairs Running capacitor 2.5 to 10 MFD. (Make:- Epcos/ Usha/ Keltron.) |
| 3 | S&F in repairs Running capacitor 36 to 50 MFD. (Make:- Epcos/ Usha/ Keltron.) |
| 4 | S&F in repairs Starting capacitor 80 -120 MFD. (Make:- Epcos/ Usha/ Keltron.) |
| 5 | S&F in repairs artic board universal Remote control compatible for split AC of Cap 1.5/2.0 TR of any make and model as per site requirement as directed by Engr-in-Charge. |
| 6 | Supply & fixing in repairs of suction and discharge valve set 15mm (5/8'') and 10mm (3/8\\") for Split AC 2 TR capacity complete all as directed by Engr-in-Charge. |
| 7 | Supply & fixing in repairs ofsuction and discharge valve set 6mm (1/4'') and 12mm (1/2'') for Split AC 1.5 capacity complete all as directed by Engr-in-Charge. |
| 8 | Supply & fixing in repairs of capillary tube for Split/ Window type AC of capacity 1.5/2 TR complete all as directed by Engr-in-Charge. |
| 9 | Supply & fixing in repairs of capillary filter for Split/ Window type AC of capacity 1.5/2 TR complete all as directed by Engr-in-Charge. |
| 10 | Disconnecting the unserviceable PCB compatible from Inverter/non-inverter Split type AC of capacity 1.5/ 2 TR and refixing after necessary repair for satisfactory functioning of the AC unit complete all as specified and directed by Engineer-in-charge. |
| 11 | Disconnecting from mains and taking out existing unserviceable sealed compressor unit from the split type Air Conditioner of Cap 1.5 Ton, of any make any type from any location and Supply , Installing and testing of new sealed unit compressor along with test certificate from manufacturer including cleaning and removing dust/dirt from the cooling coil condenser coil with necessary modification capillary tube etc & Charging of Gas R-22/R-32/R-410a and commissioning complete all as specified & directed by Engg-in-Charge. (Make:- Emerson /Tecumseh/ LG) |
| 12 | Disconnecting from mains and taking out existing unserviceable sealed compressor unit from the split type Air Conditioner of Cap 2 Ton, of any make any type from any location and Supply , Installing and testing of new sealed unit compressor along with test certificate from manufacturer including cleaning and removing dust/dirt from the cooling coil condenser coil with necessary modification capillary tube etc & Charging of Gas R-22/R-32/R-410a and commissioning complete all as specified & directed by Engg-in-Charge. (Make:- Emerson /Tecumseh/ LG) |
| 13 | Supply & fixing in repair copper wounded Indoor Air blower motor with blade of existing Split AC 1.5/2 TR capacity complete all as specified & as directed. Make-AUE/Speed King/Cool Master. |
| 14 | Supply & fixing in repairs of copper wounded condenser fan motor with blade of existing Split type AC of 1.5 TR & 2 TR capacity outdoor units complete all as specified & as directed. (Make-AUE/Crompton Greaves/Cool Master.) |
| 15 | Disconnecting the mains and taking out the unserviceable condenser coil of split type AC of capacity 1.5/ 2TR of any make from any location and supply, fixing and testing new condenser coil as per existing size & patterns for complete all as specified & as directed. (Make :- As per existing sample) |
| 16 | Supply & fixing in repairs of evaporator/cooling coil for split type Air Conditioner of capacity 1.5/ 2TR of existing make and size complete all as specified & as directed by Engr-in-Charge. |
| 17 | Supply and fixing in repairs of 1.5TR capacity split type Air Conditioner outdoor kit including, copper condenser coil, fan motor, chassis, base plate, including initial charging of gas complete all as specified & as directed by Engr-in-Charge. (Make:- Bluestar/Hitachi/Voltas) |
| 18 | Supply and fixing in repairs of 2TR capacity split type Air Conditioner outdoor kit including, copper condenser coil, fan motor, chassis, base plate, including initial charging of gas complete all as specified & as directed by Engr-in-Charge. (Make:- Bluestar/Hitachi/Voltas) |
| 19 | Taking down unserviceable indoor unit of split type AC of any make and supply & fixing new indoor unit complete kit suitable for 1.5 TR capacity including remote complete all as directed by Engr-in-Charge. (Make:- Bluestar/Hitachi/Voltas) |
| 20 | Taking down unserviceable indoor unit of split type AC of any make and supply & fixing new indoor unit complete kit suitable for 2 TR capacity including remote complete all as directed by Engr-in-Charge. (Make:- Bluestar/Hitachi/Voltas) |
| 21 | Supply & fixing heavy duty copper pipe 12 mm (1/2\\") dia/ bore complete including nitrile rubber insulation, brazing, welding, nuts, bolts and screws of required size including taking down old unserviceable one complete all as specified and directed by Engr-in-Charge. Make Godrej / Malaysia / Johnson or equivalent. |
| 22 | Supply & fixing heavy duty copper pipe 6mm (1/4\\") dia/ bore complete including nitrile rubber insulation, brazing, welding, nuts, bolts and screws of required size including taking down old unserviceable one complete all as specified and directed by Engr-in-Charge. Make Godrej / Malaysia / Johnson or equivalent. |
| 23 | Supply & fixing heavy duty copper pipe 15mm (5/8\\") dia/ bore complete including nitrile rubber insulation, brazing, welding, nuts, bolts and screws of required size including taking down old unserviceable one complete all as specified and directed by Engr-in-Charge. Make Godrej / Malaysia / Johnson or equivalent. |
| 24 | Supply & fixing heavy duty copper pipe 10mm (3/8\\") dia/ bore complete including nitrile rubber insulation, brazing, welding, nuts, bolts and screws of required size including taking down old unserviceable one complete all as specified and directed by Engr-in-Charge. Make Godrej / Malaysia / Johnson or equivalent. |
| 25 | Taking down unserviceable insulation for copper pipe, supply and fixing new insulation for copper pipes suitable for Split AC of capacity from 1.5 to 2.0 TR all as specified and directed by Engineer-in-charge. |
| 26 | M&L for replacement of PVC pipe 20mm dia heavy duty with all fittings (bend, elbow, tee) etc including fixing with clamp on wall or floor for AC drain pipe with drain cap complete as directed. Make Astral / Prince and equivalent. |
| 27 | S&F of Air filter sheet for 2.0/ 1.5/1.0 Ton AC including taking down old U/S one complete all as specified and directed by Engr-in-Charge. |
| 28 | Supply and filling refrigerant gas R-22/R-32/R-404a/R-407c/410a in window /Split Type AC unit of capacity 1.5/2 TR and in compressors of Cold storage units of any capacity as per OEM specification including detecting the leakage of gas at any location and rectifying the defect to stop the leakage by gas welding or by any other means including cutting and brazing of copper tubes testing and commissioning complete in satisfactory working condition.Make : Mefron/Floron/Refron. Note :- The rates quoted by the contractor for topping up/ filling of refrigerant gas shall deemed to include leakage detection, rectification of leakage by brazing, nitrogen pressure testing, etc. |
| 29 | Taking down unserviceable contactor and supply and fixing new contactor single phase suitable for Split AC 1.5 to 2.0 TR all as specified as directed by Engineer in-charge. Please Enable Macros to View BoQ information |
| 30 | Taking down unserviceable contactor and supply and fixing new contactor single phase suitable for Split AC 1.5 to 2.0 TR all as specified as directed by Engineer in-charge. Please Enable Macros to View BoQ information |