| 1 | Surface excavation not exceeding 30 cm deep and averaging 15cm deep and getting out in Hard/Dense soil complete all as specified and as directed by Engineer-in-Charge. |
| 2 | Excavating in trenches, not exceeding 1.5 m wide and not exceeding 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, cable, pipes etc. not exceeding 10 sqm on plan and not exceeding 1.5 m in depth and getting out in any type of soil complete all as specified and as directed by Engineer-in- charge. |
| 3 | Material and Labour for Excavating in post holes (or similar holes)each not exceeding 0.5 cum.getting out in hard/ dense soil,returning, filling in and ramming earth or broken rubble mixed with earth around,in layers not exceeding 25 cm in hard/dense soil complete all as specified and as directed by Engineer-in-Charge. |
| 4 | Material & Labour for PCC 1:3:6 , Type C2 , using 40mm graded stone aggregates as in foundations, filling and mass concrete complete all as specified and as directed by Engineer-in-Charge. |
| 5 | Material & Labour for PCC 1:4:8 , Type - D2, using 40mm graded stone aggregates as in foundations, filling and mass concrete complete all as specified and directed by Engineer-in-Charge. |
| 6 | Material & Labour for Brickwork with sub class ‘B’ burnt clay old size bricks, straight or curved on plan exc 6m mean radius built in cement mortar 1:6 complete all as specified and as directed by Engineer-in-Charge. |
| 7 | Material & Labour for PCC 1:2:4 type B1 using 20 mm graded stone aggregates as in lintel upto 1.5m clear span, cills, steps; seismic and other similar bends, plinth courses, string courses, lacing courses, parapets and railing upto 60 cm in height, copings, kneelers, apex stones, bed plates, water troughs and thelikeincluding weathering, slightly rounded or chamfered angles and throating complete all as specified and as directed by Engineer-in-Charge. |
| 8 | Material and labour for Rendering 15mm thick in Cement Mortar 1:4 , on fair faces of brick work or concrete surfaces of walls , finish even & smooth without using extra cement complete all as specified and directed by Engineer-in-Charge. |
| 9 | Material and labour for preparation of new surface of walls, with and including two coats of cement base paint ,over with and including one coat of alkali resistant priming paint complete all as specified and directed by Engineer-in-Charge. |
| 10 | Removing excavated material/soils to a distance not exceeding 50 mtr and depositing where directed at a level not exc.1.5 mtr above the starting point, complete all as spefied and as directed by Engineer-in-Charge. |
| 11 | Supply & Fixing Mild steel work as in tubular trusses and tubular post including special shaped washer etc.complete using ERW or induction butt welded tubes conforming IS:1161-1979 Grade St-240 complete all as spefied and as directed by Engineer-in-Charge. |
| 12 | `Supply & Fixing Mild steel work as in MS plates (plain or chequered)square cut or notched (forming holes with riveted,bolted welded attechment) Fe 410-w(Grade-E-250) quality-A complete all as spefied and as directed by Engineer-in-Charge. |
| 13 | Supply & Fixing Mild steel work as in Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) Fe 410 -W (Gde- E- 250) quality-A includingdistance pieces, cleats etc. complete all as speicied and as directed by Engineer in charge. |
| 14 | Material & Labour for preparation of newely steel surfaces of any description, over 10 cm in width or girth or otherwise described , with and including applying two coat of syntheic enamal paint over with and including one coat of red oxide zinc chrome primer complete all as spefied and as directed by Engineer-in-Charge. |
| 15 | Supply & Fixing Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified complete all as specified and directed by Engineer-in-Charge. |
| 16 | Supply & Fixing Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified complete all as specified and directed by Engineer-in-Charge. |
| 17 | Material & Labour for Hardcore of broken stone or boulders ,gauge not exceeding 63 mm, deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rammed to a true surface complete all as specified and as directed by Engineer-in-Charge.. |
| 18 | Material & Labour for 100mm thick plain cement concrete 1:3:6, Type C2 (using 40mm graded stone aggregates as in sub base of floor complete all as specified and as directed by Engineer-in-Charge. |
| 19 | Material & Labour for 100mm thick plain cement concrete 1:2:4,Type B2 ,using 40mm graded stone aggregates as in sub base of floor complete all as specified and as directed by Engineer-in-Charge. |
| 20 | Returning filling in, approved soft/loose soil, including spreading , levelling, watering and well ramming in layers, each layer not exceeding 25cm in any type of soil complete all as specified and as directed by Engineer-in- charge. |
| 21 | Material and Labour sand cushioning, with dry and clean fine river sand for underground cable 8 cm before laying cable and 15 cm after laying and punned to 18 cm after laying of cable complete all as specified. (Note:- Punned thickness shall be considered for payment purpose) |
| 22 | Supply and laying Best quality, locally available, sub class ‘B’ burnt clay bricks (Old Size) for cable protection cover, laid flat and dry in trenches over the cable , perpendicular to the direction of cable complete all as specified and as directed by Engineer-in-Charge. |
| 23 | Supply and laying or fixing or laid in trenches/ ducts/ through pipes/ in floors / under roads/ hard standing /along poles and testing LT cable XLPE, PVC insulated screened, bedded, galvanised steel strip or wire armourd cable (heavy duty) 1100 volt grade with aluminium conductor having cross sectional area 25 Sqmm 3.50 core conforming to IS-7098 (Part-I -1988) complete all as specified and as directed by Engineer-in-Charge. (Excavation and earth work, sand cushioning & GI pipe shall be measured and paid for separately) |
| 24 | Supply and complete installation including fixing , testing and trial running for minimum 07 days and commissioning Electric Multibin Organic Waste Composting Machine of capacity 100 kg per day fully automatic suitable for processing Biodegradeable waste with the fwg requirements with the following Technical Specifications for Micro-organisms based 24 hrs system(i) Per Day Processing Capacity- 100 Kg per Day.(ii) Composting System – 24 Hrs Micro organism Based Composting Machine.(iii) Operation and Processing – Fully automatic and within 24 hours.(iv) Input – Segregated Organic Waste.(v) Treatable items – Fruits, Furit peels, Vegetables, Vegetable peels, Fish, Fish bones, Chicken bones, Bread, Curries, garden waste.(vi) Output - Dry Organic manure / Soil Additive / Compost.(vii) Untreatable items – Coconut shells, Metal waste, Plastic, glass, big bones, large shells, petrochemicals.(viii) Power Supply – 440/50Hz.(ix) Composting tank material – Stainless Stell (SS – 304) .(x) Inbuilt Shredder Machine – Blades – En-8 Harden ( Material ) – Double Shaft Shredder Machine.(xi) Main Tank Shaft & Blades – SS High Quality Shaft with superior quality mixing with clock anti-clock system.(xii) Motor Gear Box – Planetary Gear Box.(xiii) Blower – SS High Quality Blower to remove vapour from tank – SS 304.(xiv) Handles and Locks – Standard handles and locks with good aesthetics.(xv) Control Panel – All control panel parts should be of standard brands.(xvi) Over Load Protection – Motor and Blower should have overload and current protection.(xvii) Compost Removal – After 2 – 3 Days.(xviii) Outside housing – Mild steel with pure polyester powder coating suitable for outside use and with crane lifting facility.(xix) Waste input and compost removal provision – Separate door of high quality stainless steel for waste input and compost removal.(xx) Waste Inlet Door – Stainless Steel ( SS – 304 )(xxi) Waste Outlet Door – Stainless Steel ( SS- 304 )Contd to item no. 24.00 here-in- after Please Enable Macros to View BoQ information |
| 25 | Supply and complete installation including fixing , testing and trial running for minimum 07 days and commissioning Electric Multibin Organic Waste Composting Machine of capacity 100 kg per day fully automatic suitable for processing Biodegradeable waste with the fwg requirements with the following Technical Specifications for Micro-organisms based 24 hrs system(i) Per Day Processing Capacity- 100 Kg per Day.(ii) Composting System – 24 Hrs Micro organism Based Composting Machine.(iii) Operation and Processing – Fully automatic and within 24 hours.(iv) Input – Segregated Organic Waste.(v) Treatable items – Fruits, Furit peels, Vegetables, Vegetable peels, Fish, Fish bones, Chicken bones, Bread, Curries, garden waste.(vi) Output - Dry Organic manure / Soil Additive / Compost.(vii) Untreatable items – Coconut shells, Metal waste, Plastic, glass, big bones, large shells, petrochemicals.(viii) Power Supply – 440/50Hz.(ix) Composting tank material – Stainless Stell (SS – 304) .(x) Inbuilt Shredder Machine – Blades – En-8 Harden ( Material ) – Double Shaft Shredder Machine.(xi) Main Tank Shaft & Blades – SS High Quality Shaft with superior quality mixing with clock anti-clock system.(xii) Motor Gear Box – Planetary Gear Box.(xiii) Blower – SS High Quality Blower to remove vapour from tank – SS 304.(xiv) Handles and Locks – Standard handles and locks with good aesthetics.(xv) Control Panel – All control panel parts should be of standard brands.(xvi) Over Load Protection – Motor and Blower should have overload and current protection.(xvii) Compost Removal – After 2 – 3 Days.(xviii) Outside housing – Mild steel with pure polyester powder coating suitable for outside use and with crane lifting facility.(xix) Waste input and compost removal provision – Separate door of high quality stainless steel for waste input and compost removal.(xx) Waste Inlet Door – Stainless Steel ( SS – 304 )(xxi) Waste Outlet Door – Stainless Steel ( SS- 304 )Contd to item no. 24.00 here-in- after Please Enable Macros to View BoQ information |