| 1 | Supply, laying or passing through pipe LT, XLPE insulated, galvanised steel strip or wire armoured electric power cable conforming to IS:7098 (Pt-I)-1988, heavy duty with stranded aluminium conductor 1100 Volts grade of size 400 Sqmm 3.5 core with necessary fixing arrangements such as lugs, glands and terminal etc including connecting/testing after taking out unserviceable LT UG cable from trenches/ pole complete all as specified and directed.NOTE: Excavation, earth work shall be measured and paid for separately. |
| 2 | Supply, laying or passing through pipe LT, XLPE insulated, galvanised steel strip or wire armoured electric power cable conforming to IS:7098 (Pt-I)-1988, heavy duty with stranded aluminium conductor 1100 Volts grade of size 300 Sqmm 3.5 core with necessary fixing arrangements such as lugs, glands and terminal etc including connecting/testing after taking out unserviceable LT UG cable from trenches/ pole complete all as specified and directed.NOTE: Excavation, earth work shall be measured and paid for separately. |
| 3 | Supply, laying or passing through pipe LT, XLPE insulated, galvanised steel strip or wire armoured electric power cable conforming to IS:7098 (Pt-I)-1988, heavy duty with stranded aluminium conductor 1100 Volts grade of size 240 Sqmm 3.5 core with necessary fixing arrangements such as lugs, glands and terminal etc including connecting/testing after taking out unserviceable LT UG cable from trenches/ pole complete all as specified and directed.NOTE: Excavation, earth work shall be measured and paid for separately. |
| 4 | Supply, laying or passing through pipe LT, XLPE insulated, galvanised steel strip or wire armoured electric power cable conforming to IS:7098 (Pt-I)-1988, heavy duty with stranded aluminium conductor 1100 Volts grade of size 150 Sqmm 3.5 core with necessary fixing arrangements such as lugs, glands and terminal etc including connecting/testing after taking out unserviceable LT UG cable from trenches/ pole complete all as specified and directed.NOTE: Excavation, earth work shall be measured and paid for separately. |
| 5 | Supply, laying or passing through pipe LT, XLPE insulated, galvanised steel strip or wire armoured electric power cable conforming to IS:7098 (Pt-I)-1988, heavy duty with stranded aluminium conductor 1100 Volts grade of size 120 Sqmm 3.5 core with necessary fixing arrangements such as lugs, glands and terminal etc including connecting/testing after taking out unserviceable LT UG cable from trenches/ pole complete all as specified and directed.NOTE: Excavation, earth work shall be measured and paid for separately. |
| 6 | Supply, laying or passing through pipe LT, XLPE insulated, galvanised steel strip or wire armoured electric power cable conforming to IS:7098 (Pt-I)-1988, heavy duty with stranded aluminium conductor 1100 Volts grade of size 95 Sqmm 3.5 core with necessary fixing arrangements such as lugs, glands and terminal etc including connecting/testing after taking out unserviceable LT UG cable from trenches/ pole complete all as specified and directed.NOTE: Excavation, earth work shall be measured and paid for separately. |
| 7 | Supply, laying or passing through pipe LT, XLPE insulated, galvanised steel strip or wire armoured electric power cable conforming to IS:7098 (Pt-I)-1988, heavy duty with stranded aluminium conductor 1100 Volts grade of size 70 Sqmm 3.5 core with necessary fixing arrangements such as lugs, glands and terminal etc including connecting/testing after taking out unserviceable LT UG cable from trenches/ pole complete all as specified and directed.NOTE: Excavation, earth work shall be measured and paid for separately. |
| 8 | Supply, laying or passing through pipe LT, XLPE insulated, galvanised steel strip or wire armoured electric power cable conforming to IS:7098 (Pt-I)-1988, heavy duty with stranded aluminium conductor 1100 Volts grade of size 50 Sqmm 3.5 core with necessary fixing arrangements such as lugs, glands and terminal etc including connecting/testing after taking out unserviceable LT UG cable from trenches/ pole complete all as specified and directed.NOTE: Excavation, earth work shall be measured and paid for separately. |
| 9 | Excavation in trenches in hard/ dense soil not exceeding 1.5 mtr wide and not exceeding 1.5 meter in depth for taking out and laying UG cable and getting out, excavated earth, forming bottom surfaces to required level complete all as specified and directed. |
| 10 | Returning filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm in soft/loose soil complete all as specified and as directed. |
| 11 | Removing excavated material (soil) n.exc 50 m and depositing where as directed at a level n.exc 1.5 m above the starting point complete all as specified and as directed. |
| 12 | Supply & Fix 50 mm dia galvanized iron tube light grade for cable protection, supporting to poles, plinth protections, road crossing, trenches, footpath etc including clamps, nut, bolt and washers etc after taking out unserviceable pipe complete all as specified and directed. |
| 13 | Material and Labour for 80 mm dia galvanized iron tube light grade for cable protection, supporting to poles, plinth protections, road crossing, trenches, footpath etc including clamps, nut, bolt and washers etc after taking out unserviceable pipe complete all as specified and directed. |
| 14 | Cutting the existing bituminous road/cement concrete surface to the required width and depth for laying UG cable/pipe and making good the disturbed surface of road/path to even surface to match with existing level of road using cement concrete and removing and depositing the debris to a place complete all as specified and as directed. NOTE: Plain Cement concrete shall be measured and paid separately under relevant items of BOQ. |
| 15 | Material and Labour for 100mm thick plain cement concrete 1:2:4 type B2 using 40mm graded granite stone aggrgate as floor and other similar type of work, laid in panels and finishing cement concrete surface even and smooth Without using extra cement, complete all as specified and as directed. |
| 16 | Supply and laying double wall corrugated pipe (DWC) conforming to IS 19430 Part - I of size 180 mm outer dia and 152 mm inner dia complete all as specified and as directed |
| 17 | Supply and laying double wall corrugated pipe (DWC) conforming to IS 16098-2 of size 120 mm outer dia and 103.5 mm inner dia complete all as specified and as directed |
| 18 | Supply and laying double wall corrugated pipe (DWC) conforming to IS 19430 Part - I of size 50 mm outer dia and 38 mm inner dia complete all as specified and as directed |
| 19 | M & L Cable route indicator comprising of CI wiser of size 100mm dia embossed as LT power cable fixed to MS angle iron of size 50x50x6mm graded stone aggregate of block size 300x300x450mm including two coats of aluminium paint over a coat of aluminium red oxide primer including neceessay earth work complete all as specified and directed. |
| 20 | Schedule of Credit (Minus) Rs.52100.00 NOTE: Bidder shall insert credit amount of Rs. 52100.00 as rate in Green field under Col-13. Please Enable Macros to View BoQ information |