|
| 1 | Taking down carefully copper/aluminum point wiring (Light/ fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc, stacking at site for reuse or removing materials to store for keeping in for taking credit and making good the disturbed surfaces / walls/ floors etc. |
| 2 | M&L for point wiring with 1.5 Sq. mm, multi-stranded copper conductor, single core,FRLSH PVC insulated and unsheathed cable for phase and neutral, including 1.5 Sq. mm PVC insulated unsheathed multistranded copper conductor single core cable as earth continuity conductor (in green color) connected to common earth dolly, Concealed wiring , GI terminal boxes 1.2mm thick fixed flush to wall surface, covered with & including 3 mm thick plastic laminated sheet top cover for mounting switch and sockets etc. complete all as specified and directed for following : - |
| 3 | One light point/exhaust fan point controlled by one switch or one ceiling fan point controlled by one switch & electronic type fan regulator. |
| 4 | One light point controlled by two Nos 5 Amps switch two way |
| 5 | One 3 pin 5 Amp switch & socket outlet on same board with other switches. |
| 6 | One 3 pin 5 Amp switch & socket outlet on Independant board. |
| 7 | One bell point controlled by one switch 5 Amps bell push. |
| 8 | All same as per item ser No 02 here-in-above but wiring using 2.5 sqmm multi-stranded copper conductor, single core,FRLSH, PVC insulated and unsheathed cableing(including concealed wiring and conduit into groove cutting ), including 2.5 Sq. mm PVC insulated unsheathed multistranded copper conductor single core cable as earth continuity conductor (in green color) connected to common earth dolly for 6 pin, 15/16 Amps socket outlet on independant board. |
| 9 | All same as per item ser No 02 here-in-above but wiring using 4.0 sqmm multi-stranded copper conductor, FRLSH,single core, PVC insulated and unsheathed cable,(including concealed wiring and conduit into groove cutting ) including 4.0 Sq. mm PVC insulated unsheathed multistranded copper conductor single core cable as earth continuity conductor (in green color) connected to common earth dolly for two pin earth metal clad plug & socket point for AC/Geysers. |
| 10 | S&F switch modular single pole one way 6 Amps 230 volt 1 module. |
| 11 | S&F switch modular single pole one way 16 Amps 230 volt 1 module. |
| 12 | S&F Socket modular 6 Amp 2/3 pin combined two module. |
| 13 | S&F Socket modular 6&16 Amp 2/3 pin combined two module. |
| 14 | S&F electronic fan regulator modular stepped type 120 watt, two module. |
| 15 | S&F modular Ceiling rose modular surface bakelite 65x50mm three terminal. |
| 16 | S&F modular Lamp holder insulated PVC/Polycarbonate/bakelite body, fixed on PVC round or squre box using necessay screw & gutti complete all as specified. |
| 17 | S&F modular electronic Bell Bul-Bul music, 230 volt, single phase. |
| 18 | S&F modular bell push, type, 6 Amps, 2 Module |
| 19 | S&F modular white or Ivory cover plate with frame 1 module |
| 20 | S&F modular white or Ivory cover plate with frame 2 module |
| 21 | S&F modular white or Ivory cover plate with frame 3 module |
| 22 | S&F modular white or Ivory cover plate with frame 4 module |
| 23 | S&F modular white or Ivory cover plate with frame 6 module |
| 24 | S&F modular white or Ivory cover plate with frame 8 module |
| 25 | M&L Point wiring complete with 1.5 Sqmm single core multi standard copper conductor PVC FLRS insulated unsheathed cable in and incl PVC casing capping / PVC Conduit with accessories existing pressed steel terminal boxes (sunk in wall) including new 3.00 mm thick plastic laminated sheet top cover with 1.50 Sqmm insulated unsheathed PVC covered copper conductor for common earth and connecting to earth dolly for :- |
| 26 | One light point controlled by one one way switch |
| 27 | One fan point controlled by one one way switch |
| 28 | One bell point controlled by one bell push switch |
| 29 | One socket out let 5 Amps on the same board |
| 30 | One socket out 3 pin 5 Amps on the independent board. |
| 31 | All as per item No 20.00 above but with 2.5 Sq mm single core multi standard copper conductor cable for 6 pin 15 Amps socket out let on independent board. |
| 32 | S&F switch flush type 5 Amp, 240 V single pole one way ISI Marked. |
| 33 | S&F switch socket combination 2 in 1,5 Amps flush type |
| 34 | S&F switch socket combination outlet 6 pin ,6/16 Amps flush type |
| 35 | Supply and fixing in repair of LED lights fitting 1x 20W, 220V,AC aluminium body decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete.make-philips, havells, crompton |
| 36 | Supply and fixing in repair of LED lights fitting 1x 10 W, 220V,AC aluminium body decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete.make-philips, havells, crompton |
| 37 | Supply and fixing in repair of LED surface round shape lights fitting 1x 10 W, 220V,AC aluminium body decorative box type with driver, with three core flexible copper conductor cable of suitable size from ceiling rose complete.make-philips,havells ,crompton |
| 38 | S&F Wall Mounted decorative luminaire fitting suitable for LED lamp B-22 Base 9 watt light fitting including inbuild LED light driver connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed. |
| 39 | S&F in repair Building security light fittings, with pressure die cast aluminium housing, suitable for 25 W LED, complete pre-wired, incl suitable bracket for fixing light on wall or any indicated locaction all as specified and as directed by Engr - in Charge complete all as per Havells Cat No: ENDURAPEARLSL25W or equivalent model approved makes. |
| 40 | M&L for Sub main wiring as per IS, single core FRLSH PVC insulated flexible multistranded copper conductor,FRLSH, 1.1 KV grade drawn through & including PVC grey conduit heavy duty with necessary accessories (like bend, juction boxes etc) including taking down old unsv submain wiring complete all as specified for Two runs of 2.5 Sq.mm main Phase-Neutral supply cable alongwith one run of single core 2.5 Sq.mm for continuous earth wire in green color. |
| 41 | M&L for Sub main wiring as per IS, single core FRLSH PVC insulated flexible multistranded copper conductor,FRLSH, 1.1 KV grade drawn through & including PVC grey conduit heavy duty with necessary accessories (like bend, juction boxes etc) including taking down old unsv submain wiring complete all as specified for Two runs of 4.0 Sq.mm main Phase-Neutral supply cable alongwith one run of single core 4.0 Sq.mm for continuous earth wire in green color. |
| 42 | M&L for Sub main wiring as per IS, single core FRLSH PVC insulated flexible multistranded copper conductor,FRLSH, 1.1 KV grade drawn through & including PVC grey conduit heavy duty with necessary accessories (like bend, juction boxes etc) including taking down old unsv submain wiring complete all as specified for Two runs of 6.0 Sq.mm main Phase-Neutral supply cable alongwith one run of single core 6.0 Sq.mm for continuous earth wire in green color. |
| 43 | M&L for Sub main wiring as per IS, single core FRLSH PVC insulated flexible multistranded copper conductor,FRLSH, 1.1 KV grade drawn through & including PVC grey conduit heavy duty with necessary accessories (like bend, juction boxes etc) including taking down old unsv submain wiring complete all as specified for four runs of 10.0 Sq.mm main Phase-Neutral supply cable alongwith one run of single core 10.0 Sq.mm for continuous earth wire in green color. |
| 44 | Supply and replace sheet metal enclosure distribution board for 415volts, 4 way horizontal type, single door, triple pole and neutral with 200 Amps rated neutral copper bus bar for housing MCB and fixed flush in wall surface, and tested on completion complete including taking out old all as directed.Make -L&T ,Legrand,havells |
| 45 | Supply and replace sheet metal enclosure distribution board for 230volts, 12 way horizontal type, single door, tsingle pole and neutral with 200 Amps rated neutral copper bus bar for housing MCB and fixed flush in wall surface, and tested on completion complete including taking out old all as directed.Make -L&T ,Legrand,havells |
| 46 | M&L for MCB TPN/FP, 100 Amps 415 volts, 10 kA rupturing capacity providing in DB complete including connection & testing all as specified. Make -L&T ,Legrand,havells |
| 47 | Supply and fixing MCB single pole 6-32 Amps, 240 volts, 10 kA rupturing capacity providing in DB complete including connection & testing all as specified.Make -L&T ,Legrand,havells |
| 48 | Supply and fixing MCB SPN/DP (single pole and neutral) 32 Amps, 240 volts, 10 kA rupturing capacity providing in DB complete including connection & testing all as specified.Make -L&T ,Legrand,havells |
| 49 | Supply and fixing in repair of VTPN Distribution Box suitable for 415V, 3 Phase, 4 Wire system, complete with 100 Amp, 4 Pole MCCB (Thermal Magnetic Release) having minimum 25 kA breaking capacity, CRCA powder coated wall mounted enclosure (IP-42/IP-54), TPN copper busbar system (adequately rated & insulated), Neutral link, Earth bar, RYB phase indication lamps with control MCB, internal wiring, gland plate for cable entry (top/bottom), earthing studs, all hardware & accessories – complete as required. |
| 50 | Labour only for attending complaints of unserviceable ceiling fans, exhaust fans and its allied electrical repairs at domestic area of AF station Jodhpur (Outer and Inner domestic area) carrying out necessary repairs at site by replacing unserviceable spares or taking down carefully unserviceable ceiling fan/Exhaust fan by disconnecting electrical connections, unsecrewing from position, dismantling blades and removing fan and blade to workshop for carry out necessary repairs or deposit unrepairable fans/ex-fans to E/M Store yard for safe coustody all as directed and specified. All connecting wiring shall be PVC insulated single core stranded copper condutor of size 0.5 sqmm with proper color coding drawn through heat insulation sleeves of suitable size.Note : Necessary spare parts required to repair at site shall be measured and paid separately under relavant items. Necessary deposit receipt shall be provided to users for taken down fan/exhuast fan as per prescribed printed format to be arranged by contractor. Contractor shall arrange necessary transportaion to bring the taken down ceiling/exhaust fans for repair/replacement. Please Enable Macros to View BoQ information |
| 51 | Labour only for attending complaints of unserviceable ceiling fans, exhaust fans and its allied electrical repairs at domestic area of AF station Jodhpur (Outer and Inner domestic area) carrying out necessary repairs at site by replacing unserviceable spares or taking down carefully unserviceable ceiling fan/Exhaust fan by disconnecting electrical connections, unsecrewing from position, dismantling blades and removing fan and blade to workshop for carry out necessary repairs or deposit unrepairable fans/ex-fans to E/M Store yard for safe coustody all as directed and specified. All connecting wiring shall be PVC insulated single core stranded copper condutor of size 0.5 sqmm with proper color coding drawn through heat insulation sleeves of suitable size.Note : Necessary spare parts required to repair at site shall be measured and paid separately under relavant items. Necessary deposit receipt shall be provided to users for taken down fan/exhuast fan as per prescribed printed format to be arranged by contractor. Contractor shall arrange necessary transportaion to bring the taken down ceiling/exhaust fans for repair/replacement. Please Enable Macros to View BoQ information |