| 1 | For Shifting of HT/LT over head/Underground line from Nai Sarak Tel wala T/F to Musafir khana T/F Daal mandi for road widening work by PWD, Varanasi under Deposit Scheme |
| 2 | Labour and Errection Charges |
| 3 | Carriage of 3x185 sq mm XLPE Cable from store to site including loading & Unloading |
| 4 | Cartage of other materials from central store Rajatalab to Site including loading & Unloading |
| 5 | Cartage of LT Cable from rajatalab store to site including loading & Unloading |
| 6 | Laying of 11 KV cable D/C 3x185 sq mm XLPE cable by digging of kachcha/pakka road using brick, stone & sand by open trench mathod |
| 7 | Laying of double CKT 11KV 3x185sq.mm XLPE In RCC Duct provided by PWD |
| 8 | Making, jointing and looping of 11 KV XLPE O/D Cable Box 3*185 sq mm alongwith hoisting on DP. Cable loop shall be properly laid protected by patiya on top to cover the cable. |
| 9 | Making and jointing of 11 KV XLPE S/T Cable Box 3*185 sq mm |
| 10 | Laying of LT XLPE Cable AL. 3.5x95/150sq.mm in RCC Trench provided by PWD |
| 11 | Laying of LT XLPE Cable AL. 3.5x240sq.mm in RCC Trench provided by PWD |
| 12 | Laying of LT XLPE Cable AL. 3.5x150sq.mm by digging of Kachcha/pakka road by open Trench method in HDPE pipe |
| 13 | Laying of LT XLPE Cable AL. 3.5x25 sq.mm in 50 mm HDPE pipe |
| 14 | Digging , Laying & providing connection of Three Phase four wire Cu LT armoured PVC cable (4x10 Sq.mm) in PVC Pipe. |
| 15 | Digging, Laying & providing connection of Single Phase two wire Cu LT armoured PVC cable (2x6 Sq.mm) in PVC pipe |
| 16 | Erection of Plinth & installation of Outdoor type LT Disribution Boards (A-type) and Distribution feeder pillar Box ( B Type) |
| 17 | Erection of Foundation & Support Structure & installation of Distribution Service Piller Box (Type c) with grouting |
| 18 | Chemical earthing of Outdoor type LT Disribution Boards (A-type)and Distribution feeder pillar Box ( B Type)(80 mm dia,3 M long) using GI Strip |
| 19 | Earthing of Distribution Service Piller Box by MS earthing rod of 20x2500 mm. and 6 SWG GI wire etc. together with fixing arrangement as per TS. (C-Type) |
| 20 | Dismentling of Old & Used 9 Mtr ST Pole |
| 21 | Dismentling of Old & Used DB |
| 22 | Dismentling of Old & Used LT line AB cable |
| 23 | Cartage of dismantled material and pole from Site to rajatalab store including loading & Unloading |
| 24 | De-Centralised Materials. |
| 25 | 11KV 3x185sq.mm O/D H.S. type cable jointing Kit |
| 26 | Cable Jointing kit H&S, 11KV, 3x185 sq.mm S/T |
| 27 | Alu. Lug 185 sq.mm |
| 28 | D clamp for 11mtr STP |
| 29 | Hording Hanging Clamp |
| 30 | G.I. pipe 100mm dia |
| 31 | MS N&B of size with washar |
| 32 | LT XLPE Cable AL. 3.5x25sq.mm |
| 33 | Three Phase four wire Cu LT armoured PVC cable (4x10 Sq.mm.) |
| 34 | Single Phase two wire Cu LT armoured PVC cable (2x6 Sq.mm.) |
| 35 | Supply & Erection of Cable jointing kit straight through for 3.5x95 Sq. mm. XLPE Cable |
| 36 | Supply & Erection of Cable jointing kit straight through for 3.5x240 Sq. mm. XLPE Cable |
| 37 | Supply of Outdoor type LT Disribution Boards with a rupturing capacity of 50KA at 415V or as called for individual items (CPRI Approved manufacturer), openable in front and back suitable for 3 plase, 4 wire, 50Hz AC supply and an ambient temperature of 45 deg. C. The Cubicle should be weather proof, dust proof, vermin Proof and enclosure protection shall be IP-55 as per IS 2147-1962 and IS: 8623. The panels/switches boards shall be fabricated out of 14-SWG CRCA sheet steel and provided with 16 SWG hinged doors including suitable foundation. MAIN LT PANEL AT SUB STATION- 1000 & 630 KVA (Type A-1)Incomer- 1 No. 1250 Amp. TP MDO ACB with Inbuilt MPR Release with On/Off Indicating LightMetering on Incomer - 1 Set of Digital Ammeter with ASS - 1 Set of Digital Voltmeter with VSS - 1 Set of LED type Phase Indicating Light (22.5 mm.) with Control MCBsOutgoing - 7 Set of 400 Amp. TP MCCB with Spreader & Extended handle - 2 Set of 100 Amp. TP MCCB with Spreader & Extended handle(Installation of LT Distribution Boards for LT underground system (Type-A, B & C)) |
| 38 | Supply of 6 – way Distribution feeder pillar, TP & N , 3 phase ,415 v , 315 Amps incoming rating type suitable for outdoor installation , in accordance with Technical Specification |
| 39 | Supply of 3-ph 415 V , Distribution Service Piller for LT. 100 Amp Incoming 4 nos 32 Amp, TPN 12 Nos 16 Amp SPN.Rating Feeder Type Distribution Service Piller suitable for Outdoor Installation. |
| 40 | Supply of 120 mm HDPE pipe PN6,PE80 |
| 41 | Supply of 50 mm HDPE pipe PN6,PE80 |
| 42 | Supply of PVC pipe Heavy Gauge 50 mm dia. Inc all necessaory Assesories for LT 1-ph & 3-ph Cosumers with laying & Restoration |
| 43 | Supply & Erection of Cable end termination using Al. Lugs of suitable size along with all accessories |
| 44 | Supply of Cable gland of suitable size along with all accessories |
| 45 | For Temporary Shifting of LT over head line from Nai Sarak Tel wala T/F to Musafir khana T/F Daal mandi for road widening work by PWD, Varanasi under Deposit Scheme |
| 46 | Labour and Errection Charges |
| 47 | Carriage of ST pole from Rajatalab store to site including loading & unloading |
| 48 | Carriage of ABC Conductor and other material from store of site including loading and unloading |
| 49 | Erection of Pole including its grouting & muffing |
| 50 | Dismantalling of existing pole and Erection of dismantalled Pole including its grouting & muffing |
| 51 | Dismantalling of existing ABC and Laying & sagging of ABC on Newly errected pole. |
| 52 | Dismantling of ST pole with fitting |
| 53 | Dismantling of Rail pole |
| 54 | Dismantalling of Existing DB and Fixing of Newly/Existing Distribution Boxes on L.T. Pole including all clamps and material for mounting, connection and seeling |
| 55 | Dismantalling of Existing 1x35 sq.mm cable and Erection of Newly/Existing 1x35 sq.mm cable |
| 56 | Connection of service line cable consumer through Distribution boxes after commissioning of ABC line |
| 57 | Grouting of Stay rod with Stay Wire |
| 58 | Carriage of Dismantled material from site to store including loading and unloading |
| 59 | De-Centralised Materials. |
| 60 | Distribution Boxes/kiosk |
| 61 | (1x35) mm2 Allu. Cable for distribution Box |
| 62 | L.T. Clamps including its errection |
| 63 | a) Dead end Clamp with Eye hook |
| 64 | b) Suspension Clamp with Eye hook |
| 65 | c) L.T. Connector Type 'A'(Line to Line) |
| 66 | d) L.T. Connector Type 'B'(Line to DB) |
| 67 | e) L.T. Bare neutral connector (PG Clamp) |
| 68 | f) Mid Span Joint connector |
| 69 | MS Clamp for Distribution Box |
| 70 | Stay Clamp |
| 71 | M/s Nut & Bolt Please Enable Macros to View BoQ information |