| 1 | 11 Mtr long 150x150xmm G.I.R.S.Joist Pole |
| 2 | 11 KV V Cross Arm (10.2 K.G. each) |
| 3 | Top Bracket 100x50x6 mm GI channel |
| 4 | 99 SQ. MM. AAAC XLPE Covered Conductor |
| 5 | 11 KV Pin insulator Polymer |
| 6 | Back Clamp GIF/11 KV V Cross Arm |
| 7 | Earthing of Support (Coil Type) |
| 8 | Danger Plate , 2 Nos. |
| 9 | Back Clamp for danger Plate 25x3mm |
| 10 | GI bared wire anticlimbing device 3 Kg |
| 11 | Back Clamp for anticlimbing device25x3mm |
| 12 | GI Nut, Bolt & washer of different size |
| 13 | Stock storege and Insurance 3% of (A) |
| 14 | Contigency (3% of (A+C)) |
| 15 | Tool & Plant (2% of (A+C)) |
| 16 | Transport (7.5% of (A+C)) |
| 17 | Erection Charges (10% of A1+C1) |
| 18 | Erection Charges (20% of A2+C2) |
| 19 | Erection Charges (5% of A3+C3) |
| 20 | Painting of Pole in Black & Yellow Strip |
| 21 | Concreting Ratio 1:3:6 (500mm x 500mmx18 |
| 22 | Couping Ratio 1:3:6 with dimension |
| 23 | LT Stay Set Complete |
| 24 | 7/12 SWG GI stay wire, Grade-2 |
| 25 | LT Stay Clamp (1.40 Kg/Pair) |
| 26 | LT Stay insulator |
| 27 | Pole Clamp for EYE hook for (XLPE Aerial |
| 28 | EYE hook for XLPE Aerial bunched cable |
| 29 | Dead End Clamp suitable for messenger XL |
| 30 | Suspension Clamp with Eye hook for ABC |
| 31 | Cable 1.1 KV AB 3CX50+1CX35+1CX16 sqmm |
| 32 | IPC Connector Type-A main 50 to 150 sq. m |
| 33 | Coil Earthing |
| 34 | No-8 GI wire (Dia 4.6mm) 0.131 KG/mtr |
| 35 | Danger Plate (LT) |
| 36 | Back Clamp for Danger Plate 25X3mm, flat |
| 37 | GI barbed wire anticlimbing device 3kg |
| 38 | Back Clamp for anticlimbing device 25X3mm, |
| 39 | GI Nut, Bolt & washer of different size |
| 40 | Stock storege and Insurance 3% of (A) |
| 41 | Contigency (3% of (A+C)) |
| 42 | Tool & Plant (2% of (A+C)) |
| 43 | Transport (7.5% of (A+C)) |
| 44 | Erection Charges (10% of A1+C1) |
| 45 | Erection Charges (20% of A2+C2) |
| 46 | Erection Charges (5% of A3+C3) |
| 47 | Painting of Pole in Black & Yellow Strip |
| 48 | Fixing of LT Complete Stay set includes |
| 49 | String of 1.1 KV XLPE ABC (3 & 4) Wire |
| 50 | Top Channel GI 100x50x6 MM (3000 mm |
| 51 | Fish Plate 50x6mm, 2.36kg/mtr., each |
| 52 | M.U Channel GI 75x40x4.8 mm (30000 mm Ion |
| 53 | Cantilever Support Angle 50x50x6 MM G |
| 54 | 50x6 mm GI Flat for Earthing ,2.36 kg/mtr |
| 55 | LT Distribution Box with MCCB,Aluminium |
| 56 | 55mm2 All Alloy Aluminium Conductor (AAAC |
| 57 | 4 Cx 35mm2 LT XLPE Cable (Armoured)-FO |
| 58 | AB Switch (11 KV, 200A.3Pole,50 Hz) |
| 59 | H.G Fuse (11 KV.200A.3Pole) |
| 60 | P.G Clamp for 55 Sq.mm AAA Conductor |
| 61 | Disc insulator (B & S) 70 KN Polymer |
| 62 | H W fitting (B & S) 70 KN (3 bolted) |
| 63 | Lightening Arrester (12 KV,10KA Station CI |
| 64 | 11 KV Pin insulator Polymer |
| 65 | HT Stay set Complete |
| 66 | HT Stay Clamp (1.9kg/Pair) |
| 67 | HT stay insulator Type-C |
| 68 | 7/10 SWG GI stay wire, Grade-2 (15kg./ |
| 69 | 40 mm Nominal bore GI pipe (medium Gauge |
| 70 | GI Nut, Bolt of Assorted size (25kg/ |
| 71 | GI barbed wire anticlimbing device 3kg |
| 72 | Back Clamp for anticlimbing device 25X3mm, |
| 73 | Danger Plate (11 KV) |
| 74 | Name Plate |
| 75 | Back Clamp for Danger Plate 25X3mm, flat |
| 76 | Stock storege and Insurance 3% of (A) |
| 77 | Contigency (3% of (A+C)) |
| 78 | Tool & Plant (2% of (A+C)) |
| 79 | Transport (7.5% of (A+C)) |
| 80 | Erection Charges (10% of A1+C1) |
| 81 | Erection Charges (20% of A2+C2) |
| 82 | Erection Charges (5% of A3+C3) |
| 83 | Concreting Ratio 1:3:6 (500mm x 500mmx18 |
| 84 | Couping Ratio 1:3:6 with dimension |
| 85 | Fixing of stay set with 0.5cum cement c |
| 86 | Construction Earthing chamber including |
| 87 | Laying of 4C x 35 mm2 LT XLPE Cable |
| 88 | Supply and Erection of GI Fencing with G |
| 89 | Labour Charge for dismantling + Transportation Charges- Salvage Value |
| 90 | Labour Cess Please Enable Macros to View BoQ information |