| 1 | AIR CONDITIONERS(A) SPLIT AC 1.5 TON |
| 2 | Supply and installation of Split AC 1.5 Ton :- Split Air conditioner including green AC, wall mount type, classification by function cooling only, nominal marketing cooling capacity (in Ton) 1.5, nominal cooling capacity (in Watt) 4750-5800, compressor type as per BEE star rating label inverter AC - variable speed, heating capacity (in watts) NA for cooling only, material of evaporator & condensor copper, material of air filter synthetic fiber, salient features/remote control features turbo mode, dehumidification mood, power saving mood, clean mood, self diagnosis mode, quiet mode, dry mode, cool mood, fan mood, air swing mood, timer, sleep mood, auto off, fan speed control, power (on/off), temperature up/down, complete all as directed by Engineer-in-charge. |
| 3 | (B) SPLIT AC 2 TON |
| 4 | Supply and installation of Split AC 2 Ton :- Split Air Conditioner including Green AC, wall mount type, Classification by function cooling only, nominal marketing cooling capacity 2 ton, nominal cooling capacity (in watt) 6331-7736, star rating 3 star, compressor type as per BEE star rating label inverter AC - variable speed, material of evaporator & condenser copper, material of Air filter synthetic fiber, salient features/remote control features turbo mode, dehumidification mood, power saving mood, clean mood, self diagnosis mode, quiet mode, dry mode, cool mood, fan mood, air swing mood, timer, sleep mood, auto off, fan speed control, power (on/off), temperature up/down, complete all as directed by Engineer-in-Charge. |
| 5 | (C) ELECTRICAL FITTINGS |
| 6 | Taking down of the following unserviceable items including all accessories and fitting complete all as directed:- |
| 7 | 1.5 Ton Ac |
| 8 | 2 Ton Ac |
| 9 | 4 KVA stablizer |
| 10 | Ceiling Fan 1400mm |
| 11 | Exhaust Fan 300mm |
| 12 | Geyser 25 Ltr |
| 13 | Supply and fixing 4.0 sqmm ISI marked, FRLS PVC insulated, single core copper conductor cable |
| 14 | Supply and fixing 20A, SPN, industrial type socket outlet, with plug top and metal chained cover in sheet steel enclosure. |
| 15 | Supply, installation, testing and commissioning of following size soft copper piping with installation of 9 mm thick Nitrile Rubber preformed sections of ID 16 mm including supporting fixture and accessories etc., all complete (over above standard lengths of A/C) |
| 16 | 1/4'' dia |
| 17 | 3/8'' dia |
| 18 | 5/8'' dia |
| 19 | Supply PVC insulated copper cable of 3C x 4 sqmm flexible conductor copper cables |
| 20 | Supply and fixing of PVC casing caping 25 mm size for refrigerant pipes, cable size 100 x 75 |
| 21 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings. This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer-in-Charge(a) 40 mm nominal dia Pipes |
| 22 | Raksha pressure class 1, 32mm (Nominal size) CPVC Pipes of effective length 3 Meter. |
| 23 | Supply, laying, testing and commissioning of 25 mm diameter HDPE drain pipe suitable for 2 Ton AC including fixing accessories etc., complete. |
| 24 | Saddle nails mounted clips, material mild steel, size 32 mm, quantity per packet 100 |
| 25 | Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structual steel etc. as required.(a) In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works |
| 26 | Painting with synthetic enamel paint of approval brand and manufactures to give an even shade(a) Two or more coats on new work |
| 27 | (D) VOLTAGE STABILIZER |
| 28 | Supply and installation of Voltage Stabilizer :- automatic line voltage correctors, 4 KVA, input voltage range single, phase sine wave (90V-300V), output voltage range single phase, sine wave (195 V to 245 V), material of enclosure metallic, Material of winding copper, mounting type wall mounting, complete all as directed by Engineer-in-Charge. |
| 29 | (E) AC CEILING FAN, EXHAUST AND GEYSER |
| 30 | (I) AC CEILING FANSupply, Installation, testing and commissioning of ceiling fan with brush less Direct Current (BLDC) Motor, class of insulation: B, 3 nos metal (Aluminum alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/AI body power factor not less than 0.9, service value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10% suitable for operation with regulator for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 deegre C (max.), insulation resistance more than 2 mega, suitable for 230 V, 50Hz, single phase AC ceiling fan complaint to IS 374-2019 fan supply earthing etc. complete as required.(a) 1200 mm, service value > 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum) |
| 31 | (II) EXHAUST FANSupply and installation of Exhaust Fan :- Size of fan 300 mm number of pole 6, number of blades 3, rated voltage 230 V, 50 Hz, AC single phase, type of fan capacitor type, power factor 0.9, standard installation accessories frame, legs set, rubber clamps and other hardware including in the scope of supply accessories with each fan for installation frame, legs set, complete all as directed by Engineer-in-Charges. |
| 32 | (III) GEYSER ACSupply and installation Geyser AC :- capacity 25 ltr,material of outer container ABS, material of inner container stainless steel, minimum length of flexible cable with 3 pin of plug of 16 amps 2 mtr, wall mounting vertical, complete all as directed by Engineer-in-Charge. |
| 33 | (F) LED light fixtures |
| 34 | Supplying, installation, Testing & Commissioning of Panel light 2x2 ft., of following body material construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, freq 50/60 Hz, CFL fixtures on wall/ Celing including all fixing accessories such as leads, teak wood round block etc. All complete as directed by Engineer-in-Charge.(a) 2 X 2 LED Ceiling light 40 watt. |
| 35 | Supplying, installation, Testing & Commissioning of 36W 1 x 4 LED Panel light Surface Mount, Cool White 6500K 600 lumens – bright and clear illumination 240V – compatible with standard power supply . EASY installation. All complete as directed by Engineer-in-Charge |
| 36 | Supplying, installation, Testing & Commissioning of 18 W Surface light (Luminaire) Conforming to IS 10322 (Part 5/Section 2) and Particular Requirements for LED Luminaire (Recessed Luminaire) conforming to IS 16107 (Part 2/Section 1) Class I [as per clause 2.1 Section 2 of IS 10322 (Part 1)] Complies to IS 10322/Part 5/Section 2 Working life for LED (in Hours) (Burning hours as per LM-80 and LM 21 Reports) - Minimum 50000Die-cast aluminium /CRCA/Extruded Aluminium Short Circuit Protection, Over Load Protection, High Voltage Test (1.5 KV for one minute between supply terminals and body of the unit), Insulation Resistance Between Earth and Current Carrying Part |
| 37 | Supplying, installation, Testing & Commissioning of 70 W LED Flood light ED Luminaire for Floodlights work on a single phase three wires system (Phase, Neutral, and Earth) Conforming to IS 10322 (Part 5/Section 5) and IS 16107 (Part 2/Section 1) Complies to IS 10322/Part 5/Section 5 Luminaire System Efficacy (lm/watt) - Minimum (hint: Total Lumen Calculation: Example: 30W LED Rating x 100 lm/watt=3000 Lumens) Colour Temperature (in K) (+/-500K) 6000 ousing in the pressure die casted aluminium (LM6) alloy with higher thermal conductivity Working life for LED (in hours) (Burning hours as per LM-80 and TM 21 reports) 50000 |
| 38 | Schedule of Credit |
| 39 | Old unserviceable 1.5 Ton Ac |
| 40 | Old unserviceable 2 Ton Ac |
| 41 | Old unserviceable 4 KVA stablizer |
| 42 | Old unserviceable Ceiling Fan 1400mm |
| 43 | Old unserviceable Exhaust Fan 300mm |
| 44 | Old unserviceable Geyser 25 Ltr Quoted Percentage (+) / (-) and Total Amount in Figures(inclusive of CP / OH and levied Taxes) Please Enable Macros to View BoQ information |