| 1 | Water proofing treatment Fibre glass cloth and cement slurryProviding and laying water proofing treatment on roofs of slabs by applying cement slurry mixed with water proofing cementcompound consisting of applying :a) After surface preparation, first layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm.b) Laying second layer of Fibre glass cloth when the first layer is still green. Overlaps of joints of fibre cloth should not be less than 10 cm.c) Third layer of 1.5 mm thickness consisting of slurry of cement @ 1.289 kg/sqm mixed with water proofing cement compound @ 0.670 kg/sqm and sand @ 1.289 kg/sqm. This will be allowed to air cure for 4 hours followed by water curing for 48 hours. The entire treatment will be taken upto 30cm on parapet wall and tucked into groove in parapet all around. |
| 2 | Roof gradingGrading roof for receiving water proofingtreatment with : Cement mortar 1:4 (1cement : 4 sand) |
| 3 | M.S. sheet door and angle iron frameProviding and fixing 1mm thick M.S. sheet door with frame of 40x40x5mm angle iron and 3mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using M.S. angels 40x40x6mm for diagonal braces |
| 4 | Glass panes/ steel sheet/ fibre sheetProviding and fixing glass panes/ steel sheet/ fibre sheet with putty and glazing clips in steel doors, windows, clerestory windows all complete.With 4.0 mm thick glass panes |
| 5 | Polyethylene water storage tankProviding and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank |
| 6 | Ball float valve brassProviding and fixing ball valve (brass) of approvedquality, High or low pressure, with plastic floats complete :25 mm nominal bore |
| 7 | PTMT extension nippleProviding and fixing PTMT extension nipple for water tank pipe, fittings of approved quality and colour.25mm nominal bore. Weighing not less than 62 gms. |
| 8 | UPVC door frame wall thickness 2.0 mmProviding and fixing factory made UPVC door frame made of UPVC extruded sections having an overall dimension as below (tolerance ±1mm), with wall thickness 2.0 mm (± 0.2mm), corners of the door frame to be Jointed with galvanized brackets and stainless steel screws, joints mitred and Plastic welded. The hinge side vertical of the frame reinforced by galvanized M.S. tube of size 19 X 19mm and 1mm (± 0.1 mm) wall thickness and 3 nos. stainless steel hinges fixed to the frame complete as per manufacturers specification and direction of Engineer-in-charge: Extruded section Profile size 42x50 mm. |
| 9 | Panelled UPVC door shutter 24 mm thickProviding and fixing Panelled UPVC door shutter to existing door frames. 24 mm thick factory made UPVC door shutters made of styles and rails of a UPVC hollow section of size 59x24 mm and wall thickness 2 mm (± 0.2 mm) with inbuilt edging on both sides. The styles and rails mitred and joint at the corners by means of M.S. galvanised/plastic brackets of size 75x220 mm having wall thickness 1.0 mm and stainless steel screws. The styles of the shutter reinforced by inserting galvanised M.S. tube of size 20x20 mm and 1 mm (± 0.1 mm) wall thickness. The lock rail made up of a UPVC hollow 'H' section, section of size 100x24 mm and 2 mm (± 0.2 mm) wall thickness, fixed to the shutter styles by means of plastic/galvanised M.S. 'U' cleats. The shutter frame filled with a UPVC multi-chambered single panel of size not less than 620 mm, having over all thickness of 20 mm and 1 mm (± 0.1 mm) wall thickness. The panels filled vertically and tie bar at two places by inserting horizontally 6 mm galvanised M.S. rod and fastened with nuts and washers, complete as per manufacturer's specification and direction of Engineer-in-charge. (For W.C. and bathroom door shutter). |
| 10 | Demolishing cement concrete Demolishing cement concrete manually/by mechanical means including disposal of material within 50 metres lead as per direction of Engineer-in- Charge.Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix). |
| 11 | C.C. upto plinth levelProviding and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work upto plinth level : M-20 – Grade concrete |
| 12 | M.S. grills and windowsProviding and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.Fixed to openings /wooden frames withrawl plugs screws etc. |
| 13 | Synthetic enamel paint on new workPainting with synthetic enamel paint of approved brand and manufacture to give an even shade: Two or more coats on new work. Please Enable Macros to View BoQ information |