| 1 | Earthwork in excavation in foundation trenches in ordinary soil (vide classification of soil item-A) and disposal of excavated earth as obtained to a distance upto 50 M. including all lifts, levelling, ramming the foudation trenches, removing roots of trees, shrubs all complete as per approved design, building specification and direction of E/l. |
| 2 | Filling in foundation trenches and plinth in layers not exceeding 150mm thick well watered, rammed, fully compacted and fine dressed with earth obtained from excavation of foundation trenches within a lead of 50Mand lift of 1.5M all complete as per building specification and direction of E/I. (mode of measurement compacted volume) |
| 3 | Providing coarse clean sand in filling in foundation trenches or in plinth including ramming and watering in layers not exceeding 150mm thick with all leads and lifts including' cost of all materials, labour, royalty and taxes all complete as per building specification and direction of E/l (Mode of measurement complacted volume). |
| 4 | Providing designation 75 A one brick flat soling joints filled with local sand including cost of watering taxes royalty all complete as per building specification and direction of E/l. |
| 5 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - all work upto plinth level - 1:3:6 (1 cement : 3 coarse sand (zone - III): 6 graded stone aggregate 20mm nominal zie) |
| 6 | Providing designation 75A brick work in C.M (1: 6) in foundation and plinth with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm thick mortar, joints cost of screening materials raking out joints to 15mm depth , curring , taxes and royalty all complete as per builiding specification and direction of E/I. |
| 7 | Providing designation 100 A brick work with fly ash lime brick (FLAG) confirming to IS 12894-1990 (9\\"x4.5\\"x3\\") in C.M. (1:6) in foundation and plinth with approved uality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm thick mortar joints, cost of screening materials, raking out joints to 15mm depth, curing, taxes and royalty all complete as per building specification and direction of E/I. |
| 8 | Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centering and shuttering, finishing and reinforcement - all work upto plinth level 1:1.5:3 (1 cement : 1.5 coarse sand (zone - III): 3 graded stone aggregate 20mm nominal zie) |
| 9 | Reinforced cement concrete work in walls (any thickness) including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and structs etc. above plinth level upto floor five level, excluding cost of centering, shuttering, finishing and reinforcement: 1:1.5:3 (1 cement : 1.5 coarse sand (zone - III) : 3 graded stone aggregate 20mm nominal size) |
| 10 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15 degree landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases, above plinth level upto floor five level, excluding the cost of cenetering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand (zone - III): 3 graded stone aggregate 20mm nominal size) |
| 11 | Providing and laying damp-proof course 50mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand(zone-III) : 4 graded stone aggregate 20mm nominal size). |
| 12 | Centering and shuttering including strutting, propping etc. and removal of form for |
| 13 | Foundations, footings, bases of columns, etc. for mass concrete |
| 14 | Suspended floors, roofs, landings, balconies and access platform |
| 15 | Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 16 | Columns, Pillars, Piers, Abutments, Posts and Struts |
| 17 | Providing tor steel reinforcement of 8mm. dia. rods as per approved design and drawing with cutting, bending and binding with annealed wire with cost of wire, removal of rust, placing the rods in position (excluding carriage of bars to work site) all complete as per building specification and direction of E/l. TMT FE 500 ( only valid for Tata (Tiscon), SAIL, JSPL, Electrosteel Steels Ltd. Bokaro, & Vizag (RINL) |
| 18 | Providing tor steel reinforcement of 10,12,16mm . dia. rods as per approved design and drawing with cutting, bending and binding with annealed wire with cost of wire, removal of rust, placing the rods in position (excluding carriage of bars to work site) all complete as per building specification and direction of E/l. TMT FE 500 ( only valid for Tata (Tiscon), SAIL, JSPL, Electrosteel Steels Ltd. Bokaro, & Vizag (RINL) |
| 19 | 10mm dia - |
| 20 | 12 to 25mm dia |
| 21 | Supplying, fitting and fixing fully glazed steel door, window or ventilations of standard rolled 'Z' and mullion steel sections and size as per IS-1038 joints met and welded with 100X16X3mm M.S. lugs fixed in cement concrete (1:2:4) block 15X10X10cm, size including cost of oxidised iron fittings, with hinges, handle per steps, catch springs, 3mm thick plain glass panes with Aluminimum beads and inner frame fixed with lugs with 20mm long 6.3mm G.I. counter sunk machine screw and nuts and applying a coat of red lead paint carriage to work site hoisting and placing in position in all storys and taxes all complete as per building specification and direction of E/I. |
| 22 | Supplying and fixing rolling shutters of approved makemade of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks mounted on specially designed pipe shaft with brackets side guidesand arnagements for inside and outside locking with push and pull operation complete including the cost of providing and fixing necessary 27.50cm long wire sprinings manufactured from high tensile steel wire of adequate strength conforming to IS: 4454-Part 1 and M.S. top cover ofrequired thickness for rolling shutters - 80X1.25mm M.S. laths with 1.25mm thick top cover |
| 23 | Extra for providing mechanical device chain and crank operation for operating rolling shutters. Exceeding 10M2 and upto 16.80M2 in the area |
| 24 | Supplying, fitting and fixing M.S. grill made of 20x6mm M.S. flat as per approved design and drawing, properly fabricated with joints continuous fillet welded and finished smooth , carriage of grill to work site, hoisting as per building specification and direction of E/l. (where materials is not supplied by the deptt.) |
| 25 | Providing and fixing fan hook of 16mm dia M.S. bar 1 metre long bent to required size and shape, placed in position and fixed in R.C.C. slab/beam at the time of casting all complete as per building specification and direction of E/l. (where material is not supplied by deptt.) |
| 26 | 52mm thick cement concrete flooring with concrete hardener topping under layer 40mm thick cement concrete 1:2:4) 1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate 6mm nominal size) by volume, hardening compound mixed @ 2 ltrs per 50 kg. of cement or as per manufactuers specification This includes cost of cement slurry but excluding the cost of nosing of steps etc. complete |
| 27 | Providing and laying 25mm thick kotah stone tiles in risers of steps skirting and pillars of approved size texure and colour laid over 12mm thick cement mortar (1;30 and joined with grey cement slurry mixed with pigment to match the shade of the slab including rub bing to granolithic finish with approved quality of carborandum stone including cost of curing, taxes and royalty all complete as per building specification and direction of E/I. |
| 28 | Providing 12mm cement plaster (1:6) with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/l. |
| 29 | Providing 6mm thick cement plaster (1:4) in ceiling with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/l. |
| 30 | Providing 25mm thick water proof cement plaster (1:3) with clean coarse sand of F.M. 1.5with 5% cico or any other approved water proofing compoundincluding taxes and royalty all complete as per building specification and direction of E/l. (design plaster) |
| 31 | Providing 12mm thick water proof cement plaster (1:3) with clean coarse sand of F.M. 1.5with 5% cico or any other approved water proofing compoundincluding taxes and royalty all complete as per building specification and direction of E/l. |
| 32 | Finishing walls with acrylic sommth exterior paint of required shade: New work (two or more coats applied @ 1.67ltr/10sqm) over and including priming coat of exterior primer applied @ 2.20kg/10sqm. |
| 33 | Providing two coats of synthetic enamel paint of approved shade and make over steel surface including cleaning the surface thoroughly, scaffolding and taxes all complete as per building specification and direciton of E/l. |
| 34 | Providing 250 mm wide BRICK DRAIN in cement mortar (1:6) with avarage 150mm. Clear depth and 250 mm apron including cost of earthwork involved with 75m cement concrete (1:4:3) over one brick designation 75A, flat soling in proper grade and slope at the base , the drain dully plastered in C.M.(1:3) with puning over exposed surface all complete as per building specification and direction of E/I. |
| 35 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. |
| 36 | Carriage of materails |
| 37 | Bricks - Lead - 10km. |
| 38 | Sand - Lead 15km |
| 39 | Chips - Lead 15km |
| 40 | Metal - Lead 15km. |
| 41 | ELECTRCIAL WORK |
| 42 | Point Wiring in PVC Conduit, with Modular type Switch: Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface/recessed PVC conduit, with modular type switch, modular plate, suitable size of GI box etc as required. |
| 43 | Supply and Fixing Light Plug Point with Modular Type Accessories: Supply and Fixing GI box with modular plate and cover in front on surface or in recess including providing and fixing 3 pin, 5/6 amps modular socket outlet and 5/6 amps modular type switch, connection, painting etc as required. |
| 44 | Supply and Fixing Light Plug Point with Modular Type Accessories: Supply and Fixing GI box with modular plate and cover in front on surface or in recess including providing and fixing 6 pin, 15/16 amps modular socket outlet and 15/16 amps modular type switch, connection, painting etc as required. |
| 45 | Circuit / Sub-main wiring in PVC Conduit: Wiring for circuit / sub-main wiring along with earth wire with the following sizes of PVC insulated, copper conductor, single core cable in surface/recessed PVC conduit as required. |
| 46 | 2x1.5 Sqmm + 1x1.5 sqmm earth wire |
| 47 | 2x2.5 Sqmm + 1x2.5 sq mm earth wire |
| 48 | 2x4 Sqmm + 1x4 sq mm earth wire |
| 49 | S/F TP MCB DB:- Supplying and fixing of following way, three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required (Without MCB/RCCB/ISOLATOR). (All TP MCB DB shall be as per IS:8623) |
| 50 | 4 Ways (4+12 ways) double door |
| 51 | S/F 'C' series MCB:- Supplying and fixing 240 volts, 'C' series, miniature circuit breaker suitable for inductive loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc, as required. |
| 52 | 6/32A Single Pole |
| 53 | 6/32A TPN MCB |
| 54 | S/F Ceiling Rose: Supplying and fixing 2 pin ceiling rose on the existing junction box/ wooden block including connection etc as required. |
| 55 | S/F Modular type electronic fan regulator: Supplying and fixing stepped type fan regulator on the existing modular plate switch box including connections but excluding modular plate etc as required. |
| 56 | ITC Exhaust Fan upto 450 mm sweep: installation of exhaust fan upto 450 mm sweep in the existing opening, including making the hole to cut the size of the above fan, making good the damage, including connection, testing, commissioning etc as required. |
| 57 | S/F Batten / Angle Holder: Supplying and fixing batten / angle holder including connection etc as required. |
| 58 | S.I.T.C of following rating surface mounted LED tube light fittings suitable for 230V, 50Hz, single phase supply etc. complete as required - 20/22W. LED tube light |
| 59 | Bulk head fitting with 9/10Watt CFL/LED |
| 60 | Supplying, 15/16 Watt LED bulb of approved make |
| 61 | Supply, installation, testing and commissioning of following size ceiling fan 3 blades confirming to IS:374:2019 including wiring the down rods of standard length (upto 30cm) with 1.5sq.mm. FR. PVC insulated copper wire suitable for 230V, 50Hz, single phase supply etc. complete as required. - 1400mm (56\\") ceiling fan |
| 62 | Supplying Exhaust fan of 12\\" (300mm) of aproved make |
| 63 | Provioding and laying 1.1 KV grade aluminium armoured cable as per IS 1554 (Part I) heavy duty all cost complete including cost of brass compression gland, cable jointing and end termination as per specification and direction f E/I. |
| 64 | 3.5 core, 50 sq.mm |
| 65 | 3.5 core, 25 sq.mm |
| 66 | Add 18% Gst |
| 67 | Add 1% Labour Cess Please Enable Macros to View BoQ information |