| 1 | DSR item No.1.10 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required. |
| 2 | Group-B |
| 3 | 1.15 Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required. |
| 4 | Group-B |
| 5 | Group-C |
| 6 | DSR item No.1.24 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 7 | 5/6 A switch |
| 8 | DSR 1.27 Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. |
| 9 | 6 Module (200 mm x 75 mm) |
| 10 | 8 Module (125 mm x 125 mm) |
| 11 | 12 Module (200 mm x 150 mm) |
| 12 | DSR item No.1.17 Supplying and drawing following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. |
| 13 | 3 x 1.5 sq.mm |
| 14 | 3 x 2.5 sq.mm |
| 15 | 3 x 6 sq.mm |
| 16 | DSR 1.21 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 17 | DSR 2.3 Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 18 | 8 way, Double door |
| 19 | DSR Item No. 2.4 Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without (MCB/RCCB/Isolator) |
| 20 | 4 way (4 + 12), Double door |
| 21 | DSR 2.10 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 22 | Single pole |
| 23 | Double Pole |
| 24 | Triple Pole and Neutral |
| 25 | DSR item No.8.1 LED Down lighter (SMD Type) (System lumen efficacy ≥ 105 < 120 lm/Watt )(Please refer DNIT for complete specification of item no.10) |
| 26 | 22 Watt. |
| 27 | DSR item No.8.9 LED Batten light (System lumen efficacy ≥105 <120 lm/Watt).(Please refer DNIT for complete specification of item no.11) |
| 28 | 40 watt |
| 29 | DSR item No.8.13 LED Street light fixture, powder coated pressure die cast aluminium body (System lumen efficacy ≥120 <135 lm/Watt) (Please refer DNIT for complete specification of item no.12) |
| 30 | 45 watt |
| 31 | DSR item No.8.16 LED Flood Light, powder coated pressure die cast aluminium (System lumen efficacy ≥120 and <135 lm/Watt). (Please refer DNIT for complete specification of item no.13) |
| 32 | 100 Watt |
| 33 | DSR item No.9.1 Brush Less Direct Current (BLDC) Fan with Remote(Please refer DNIT for complete specification of item no.14) |
| 34 | 1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum) |
| 35 | Supplying and fixing suitable size GI box 6 Module (200mmX75mm) in recess/surface as required with modular plate and cover, including providing and fixing 1 No. 3 pin 5/6 A & 1 No. 6 pin 15/16 A modular socket outlet and 1 No. 5/6 A & 1 No. 15/16 A modular switch. The job includes the cost of making interconnections with suitable copper wire and other petty material required to complete the job to the entire satisfaction of Engineer-in-Charge at site. The Modular accessories should be of Lauritz Knudsen (Entice) / ABB (Ivie) / Legrand (Myrius) / Crabtree (Athena)/ Norisys (Square series) only. |
| 36 | S/E fan hook for erection of ceiling fan. The hook shall be made out ½” dia MS bar in U shape formation. It shall be fixed after chasing the RCC slab and making necessary repair, plaster and making its original position. |
| 37 | Supply & erection of Exhaust Fan (heavy duty motor with copper wound metallic body) following size complete with motor, metallic blades, double ball bearing with minimum power consumption, rigid frame with rubber mounting for silent operation, epoxy powder coating along with metallic louver to be installed in the existing opening including cost of making the hole to suit the size of above fan making good the damage, Carriage Charges connection, testing, commissioning etc. as required to complete the job to the entire satisfaction of EIC. |
| 38 | Size 12 inch (300mm) Sweep, 900 RPM Heavy Duty Exhaust fan (Single Phase) with louver of Havells (Turbo Force SP) / Orient (Industrial Heavy Duty)/ Usha (Turbo HDEF)/ Crompton (EXHD300-6-1)/ Bajaj (Supreme Plus) make only. |
| 39 | Providing and fixing following rating MCCB 4 pole 415 Volt (Thermal magnetic / microprocessor release) for adjustable Over load and adjustable short circuit protection, 36 KA Breaking capacity (Ics=100% of Icu) with positive isolation. The overload & short circuit release shall be of adjustable type, suitable for isolation The MCCB is to be installed in existing cubicle panel / angle iron board/ VTPN BDB / MCCB enclosure including drilling holes in cubicle panel / angle iron board, making connections with suitable rating of copper wire / copper strip etc. as required. The job includes the cost of spreaders terminal links. The job also includes cost of MS enclosure or direct/ extended rotary handle etc. as required to complete the job to the entire satisfaction of Engineer-in-charge. The MCCB should be of Lauritz Knudsen/ Siemens/ Schneider/ Legrand/ ABB/Hager make only. |
| 40 | 100 Amp 4 Pole MCCB (Thermal Magnetic release). Please Enable Macros to View BoQ information |