| 1 | PART A: ELECTRICAL (Item No:1 to 42) :- Supplying, Installation, Testing & Successful Commissioning of 5 Watts, LED Batten Light (light colour as per choice of Engineer-Incharge), ready to use, complete with internal wiring, to fix with required length of any standard make rated 3 core copper wire, with suitable hardwares etc., to fix on wall surface / ceiling / cubical as per site requirement; to work with 230V Single Phase, 50Hz AC Supply. The end wire from the fitting to be terminated to a 5 Amps Modular Switch. Make for All : Please refer Special Electrical Conditions under Tender Document File. |
| 2 | Supplying, Testing and Successful Commissioning of 4 Core x 50.0 sq. mm PVC insulated and PVC sheathed / XLPE aluminium armoured conductor cable of 1.1 KV grade as required. The laying of the cable are mentioned under S.No 37 & 38. UG Cable Make: Please refer Special Electrical Conditions under Tender Document File. |
| 3 | Supplying, Laying and Termination of 3.5 Core X 25.0 Sq. Mm Armoured Copper Conductor LT Cable in Surface / Recess with medium class suitable size PVC conduit as required. Make for Cable & Pipe: Same as Item No: 2. Note: All start & end point of the wires are to be terminated with \\"Cu\\" Lugs of suitable type and size. |
| 4 | Supplying, Installation, Testing & Successful Commissioning of 8 Modular PVC Base & Cover Plate in cubicles using suitable hardwares etc., as per directions of Engineer In-Charge and consisting of following Modular items a) 5/6 Amp Switch - 3 Nos; b) 3 Pin 5/6 Amp Socket Outlet - 2 Nos; c) 10 Amps, SP, \\"C\\" Curve, 10kA, 230V Mini MCB - 1 No. and 15 Amps 3 Pin Plug Top - 1 No with 3 Meters of 2.5 sq.mm 3 Core Copper Wire. Internal wiring for Switch & Socket with 2.5 sq.mm FRLS / HFFR Multistrand, Single Core (Red and Black Colour for Phase and Neutral) Copper Wire and 4.0 sq.mm FRLS / HFFR Multistrand, Single Core (Green Colour) Copper Wire for Earthing Loop and to terminate all the wires using suitable size Copper Lugs etc., as required. Make for All : Please refer Special Electrical Conditions under Tender Document File. |
| 5 | Supplying, Installation, Testing & Successful Commissioning of 16 PVC Modular Box along with Modular Base, Cover Plate etc., in recess / wall using suitable hardwares etc., as per directions of Engineer In-Charge and consisting of following Modular items a) 5/6 Amp Switch - 2 Nos; b) 3 Pin 5/6 Amp Socket Outlet - 2 Nos; c) 15/16 Amp Switch - 2 Nos; d) 6 pin 15/16 Amp Socket Outlet - 2 Nos and e) 20 Amps, 2 Pole, \\"C\\" Curve, 10kA, 230V Mini MCB - 1 No. Internal wiring for 5 Amps Switch & Socket with 2.5 sq.mm FRLS Multistrand, Single Core Copper Wire; for 15 Amps Switch & Socket with 4.0 sq.mm FRLS Multistrand, Single Core Copper Wire; Red and Black Colour for Phase and Neutral and 4.0 sq.mm FRLS Multistrand, Single Core Green Colour Copper Wire for Earthing Loop and terminate all the wires using suitable size Copper Lugs etc., as required. Make: Same as Item No:4 |
| 6 | Supply, Installation, Testing and Successful Commissioning of 12 Inch Dia, 300 mm sweep, industrial type ready to use Exhaust Fan having Bird Cage with 1.5 FRLS PVC insulated, copper conductor, single core cable and to fix with required size of MS frame duly painted with one coat of primer and 2 coats of paint, suitable hardwares etc., and provide one no. of 3 Pin 5/6 Amps ISI make Socket along with Gangbox and 3 Pin 5/6A Amps ISI make Plugtop as required. Make for All : Please refer Special Electrical Conditions under Tender Document File. |
| 7 | Supply, Installation, Testing and Commissioning of 1200 mm sweep, Energy Saving Brush Less Direct Current (BLDC) Motor Ceiling Fan with Decorative Down Light, class of insulation: B, having minimum 4 blades and maximum 5, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerence as per IS: 374-2019), THD less than 10%, electronic remote for speed & light control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree c (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply, earthing etc. complete as required. Fan Colour: Antique Copper Rosewood / Black Antique Brass / Antique Brass / Antique Wood Finish. Make: Please refer Special Electrical Conditions under Tender Document File. Note: Engineer In-Charge shall have all rights to select the Model from the agreed make. |
| 8 | Supply, Installation, Testing and Successful Commissioning of MCB Distribution Box of size 8\\" (W) x 8\\" (H) x 8\\" (D) made out 1.6mm thick CRCA sheet steel enclosure, painted with 2 coats of primer & 2 coats of Siemens Gray colour paint, suitable for 230V / 440V, AC to fix on surface / recess. The DB shall consist of Din Rail to fix 1 x 40Amps 2 Pole RCCB having a sensitivity current 30mA, 1 x 32 Amps 2 Pole MCB, \\"C\\" Curve, 10kA Breaking Capacity, 2 nos of blank plates and respective colour LED Indicator for the output tapped from R / Y / B Phase. The output from the RCCB to be connected to the MCB as Input with 6.0 sq.mm single core copper wires (Red & Black), duly terminated with copper lugs. The incoming earth wire from the mains should be terminated to the earth bolt / bar in the box with lugs. Make: Please refer Special Electrical Conditions under Tender Document File. Note: Labelling to be done for Input & Output Control in Paint / Acrylic Sticker. |
| 9 | Single Door IP55 Indoor MCCB Box of size 12\\" (W) x 24\\" (H) x 12\\" (D) made out of 1.6mm thick CRCA sheet steel enclosure, painted with two coats of red oxide & two coats of enamel paint siemens gray colour and consisting of 1 No of 250A, 36KA Range 4P MCCB and 4 x 250A capacity Copper Bus-Bars for R,Y,B & N. The Bus-Bars should have minimum 4 sets of holes to connect Copper Cables / Wires of size from 10.0 sq.mm to 25.0 sq.mm. The Box should have provision for mounting on the wall with required hardware arrangements, locking arrangements for door, RYB LED Indicating Lamps, 2 nos of earth bolts on either side of the box, 3 numbers of removable plate at the top of the box for Cable/Wire entry, any fire proof sheet to cover the bus-bars, water proof vents on both the sides covered with wire mesh from inside to avoid entry of any insects entering inside the box. To connect the existing Aluminium / Copper Cable as input to the MCCB. Make: Same as Item No:8. Note: Labelling to be done for Input & Output Control in Paint / Acrylic Sticker. |
| 10 | Single Door IP55 Indoor MCCB Box of size 36\\" (W) x 48\\" (H) x 20\\" (D) made out of 1.6mm thick CRCA sheet steel enclosure, painted with two coats of red oxide & two coats of enamel paint siemens gray colour and consisting of 1 x 100A, 440V AC 4 Pole Change Over Switch, 1 x 100A, 440V, 30kA, 4 Pole MCCB and 10 x 40A, 2P RCCB, 230V AC with 30mA Sensitivity. The output from the COS to be connected to 100 Amps MCCB as Input rated Copper Cable. The output from the MCCB shall be connected to the 40A RCCBs through rated Copper FRLS / HFFR Multistrand Flexible Wires, neatly dressed. The Box should have provision for mounting on the wall with required hardware arrangements, locking arrangements for Door, 2 x RYB LED Indicating Lamps, 2 nos of earth bolts on either side of the box, 2 numbers of removable plate at both top & bottom of the box for Cable / Wire entry, 6\\" x 6\\" water proof vents on both the sides covered with wire mesh from inside. To connect 3.5 Core X 25 sq. mm Armoured Copper Conductor LT Cable as input to the COS using suitable type copper lugs. Make: Same as Item No:8. Note: Labelling to be done for Input & Output Control in Paint / Acrylic Sticker. |
| 11 | Supply, Installation, Successful Commissioning and Testing of LT IP55 Indoor Panel Box of size 60 Inches (W) x 60 Inches (H) x 20 Inches\\" (D) made out of 1.6mm thick CRCA sheet steel enclosure, painted with 2 coats of red oxide & 2 coats of Siemens Gray colour paint and and consisting of items as mentioned in a) to g). At the bottom of the Panel, 1 x 200A, 36kA, 4P MCCB shall be fixed and newly laid 25.0 sq.mm XLPE Copper Cable shall be terminated as Input. The Output from the 200A MCCB shall be connected to suitable range (600mm (L) x 25mm (H) X 6mm (D)) Copper Bus-Bars using same rating Copper Cable / Copper Bus-Bar. From the Bus-Bar, inputs shall be tapped for 2 x 125A, 36kA, 4P MCCB, 4 x 63A 4 Pole, 30mA RCCB and to 3 x 40A 2 Pole, 30mA RCCB and 1 x 5 Pin 63 Amps Industrial Type Metal Clad Socket (one of the 125A MCCB will be used for this); all these control gears to connect through 25.0 sq.mm, 16.0 sq.mm and 6.0 sq.mm FRLS / HFFR Multistrand Copper Wires respectively using suitable type of lugs and standard colour code of wiring in a neatly dressed manner. All new / existing out-going Cables / Circuits to be connected to this LT Panel. A Separate Aluminium Bus-Bar for connecting the Sub-Circuits Earth Wires in the Panel and extended for 2 Inches outside the Panel on both sides, for connecting Bare Copper Wires from the Earthpit should be provided. 3 Nos of plate cutting for fixing glands, entry and exit of Copper / UG Cable(s), Cable Alley are to be made available. The panel shall be have individual hinges with locking arrangement doors for each MCB / RCCB / MCCB distribution chamber within the compartment. The LT Box shall be mounted on the floor with total stand height of 0.75-1.5 Feet grouted to the floor, doors on front with locking arrangements. The stand portion from the floor on all 4 sides shall be suitable covered with removable type painted metal sheet (screwed to the stand). All visible Bus-Bars inside the Panel shall be suitably covered with the any fire proof electrical grad sheet. 6\\" x 6\\" water proof vents shall be provided on both the sides of the Panel, covered with wire mesh from inside. a) 600mm (L) x 25mm (H) X 6mm (D) Copper Bus-Bars insulated with fire proof tape, mounted on Bus Bar Insulators. - 04 Nos. b) 200A, 50kA, 4 Pole MCCB - 01 No. c) 125A, 36kA, 4 Pole MCCB - 02 No. d) 63A, 4 Pole RCCB 440V AC with 30mA sensitivity - 04 Nos. e) 40A, 2 Pole RCCB 230V AC with 30mA sensitivity - 03 Nos. f) 63 Amps, 5 Pin Industrial Type Metal Clad Plug & Socket - 01 Set. g) Multifunctional 3 Phase, 4 Wire Electronic Trivector Energy Meter with Class 0.1 Accuracy - 01 No. h) RYB LED Phase Indication Lamps with Fuse Unit for Input and Output - 2 Sets. i) HT Rubber Mat of 6' x 3' - 01 No. j) Aluminium Earth Bus-Bar 50mm x 5mm - 01 No. The LT Panel is also included for Supply, Installation, Successfull Commissioning and Testing of 1 number Of suitable range Multifunctional 3 Phase, 4 Wire Electronic Trivector Energy Meter with Class 0.1 accuracy, required range of CTs, to read and record upto 250 Amps. Important: All incoming / outgoing armoured cables / Sub-Main Circuits shall be terminated with suitable size copper / aluminium lugs (for copper cables / wires, coppler lugs and for aluminium cables / wires, aluminium lugs). During connections, if any Incoming / Outgoing cables is / are need to be extended, part of the work (Cable / Wires for extension of connection will be provided by CSIR-CFTRI). Make: Same as Item No:8. Note: Labelling to be done for Input & Output Control in Paint / Acrylic Sticker.Panel Design: As per Engineer In-Charge. |
| 12 | Supply & Fixing of 1\\" (25mm (H) x 20mm (D)) Electrical Grade Box Type Casing-Capping on Wall / Ceiling with One and Half Inch POP Screws and Wooden Gatta and to fix Tee / Elbow / Junction Boxes etc., as required. Colour: White / Ivory. 1 Length = 3 Metres. Make: Please refer Special Electrical Conditions under Tender Document File. |
| 13 | Labour charges for digging 8 feet of depth below ground level, including hard soil, rocks, cement surface etc.,if any encountered, fixing the Item No:31, refilling of soil etc., as required. (along with charcoal / coke and salt from S.No:31 as required, already estimated under S.No.31). |
| 14 | Dismantling & taking down all Old Aluminium Electrical Wirings / Lights / Switch Boards / Telephone / Old Internet Wirings and respective related wirings, hardwares etc., after carefully disconnecting the incoming electrical input and insulating the same, depositing all the old materials in an organised manner to the Auction / Electrical Section Store Yard or as per the advise of the Electrical Officer In-Charge of the Project without any damage. Note: While dismantling proper care should be taken, Telephone / Internet Network Lines etc., in all the rooms should not be disturbed / disconnected, however system engineer shall guide accordingly while dismantling as stated above. |
| 15 | Supply, Commissioning, Testing and Successful Installation of Profile Lighting having High-grade aluminum (anodized 6060, 6063-T5) with polycarbonate diffusers (milky or clear) to ensure thermal heat dissipation, 5W to 30W+ per metre (high-output options up to 96W), Colour Temperature of 2700K–3000K (Warm), 4000K (Natural), 6000K–6500K (Cool), RGB, and Tunable White, CRI: >80 or >90 for high color rendering to work in 12V or 24V DC with 12V or 24V constant voltage drivers, based on total wattage (1A to 4A typical per strip section) with LED Density of 120 LEDs per Meter for uniform, dot-free lighting to fix directly to walls or ceilings with suitable hardwares as required. Make: Please refer Special Electrical Conditions under Tender Document File. |
| 16 | Group A Wiring for light point / fan point / exhaust fan point / call bell point with 1.5 sq.mm FRLS / HFFR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq. mm FRLS / HFFR PVC insulated copper conductor single core cable etc., as required. Make: Please refer Special Electrical Conditions under Tender Document File. |
| 17 | Group B Wiring for light point / fan point / exhaust fan point / call bell point with 1.5 sq.mm FRLS / HFFR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq. mm FRLS / HFFR PVC insulated copper conductor single core cable etc., as required. Make for all: Same as Item No: 16 |
| 18 | Group C Wiring for light point / fan point / exhaust fan point / call bell point with 1.5 sq.mm FRLS / HFFR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq. mm FRLS / HFFR PVC insulated copper conductor single core cable etc., as required. Make for all: Same as Item No: 16 |
| 19 | Supplying & drawing 2 x 1.5 sq.mm size of FRLS / HFFR PVC insulated copper conductor, single core cable in the existing surface / recessed steel / PVC conduit as required. Make for all: Same as Item No: 16. Note: All start, loop & end point of the wires are to be terminated with \\"Cu\\" Lugs of suitable type and size and individual pipes for wiring. |
| 20 | Supplying & drawing 3 x 2.5 sq.mm size of FRLS / HFFR PVC insulated copper conductor, single core cable in the existing surface / recessed steel / PVC conduit as required. Make for all: Same as Item No: 16. Note: All start, loop & end point of the wires are to be terminated with \\"Cu\\" Lugs of suitable type and size and individual pipes for wiring. |
| 21 | Supplying & drawing 3 x 4.0 sq.mm size of FRLS / HFFR PVC insulated copper conductor, single core cable in the existing surface / recessed steel / PVC conduit as required. Make for all: Same as Item No: 16. Note: All start, loop & end point of the wires are to be terminated with \\"Cu\\" Lugs of suitable type and size and individual pipes for wiring. |
| 22 | Supplying & drawing 5 x 4.0 sq.mm size of FRLS / HFFR PVC insulated copper conductor, single core cable in the existing surface / recessed steel / PVC conduit as required. Make for all: Same as Item No: 16. Note: All start, loop & end point of the wires are to be terminated with \\"Cu\\" Lugs of suitable type and size and individual pipes for wiring. |
| 23 | Supplying & drawing 3 x 6.0 sq.mm size of FRLS / HFFR PVC insulated copper conductor, single core cable in the existing surface / recessed steel / PVC conduit as required. Make for all: Same as Item No: 16. Note: All start, loop & end point of the wires are to be terminated with \\"Cu\\" Lugs of suitable type and size and individual pipes for wiring. |
| 24 | Supplying & drawing 5 x 6.0 sq.mm size of FRLS / HFFR PVC insulated copper conductor, single core cable in the existing surface / recessed steel / PVC conduit as required. Make for all: Same as Item No: 16. Note: All start, loop & end point of the wires are to be terminated with \\"Cu\\" Lugs of suitable type and size and individual pipes for wiring. |
| 25 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc., as required. Make: Same as Item No:4 |
| 26 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 A & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. Make: Same as Item No:4 |
| 27 | Dismantling of ceiling fan and painting the same with with one or more coats of spray painting with synthetic enamel paint of approved brand and manufacture to give an even shade, including cleaning of surface with detergent and replacing the damaged rubber reel, nuts and bolts with washers and safety pins, reinstalling the same as required. |
| 28 | Supplying & Fixing DP sheet steel enclosure on surface / recess along with 32 A 240 V \\"C\\" curve DP MCB complete with connections, testing and commissioning etc. as required. Make: Same as Item No:8 |
| 29 | Supplying & Fixing TP sheet steel enclosure on surface / recess along with 32 A 415 V \\"C\\" curve TP MCB complete with connections, testing and commissioning etc. as required. Make: Same as Item No:8 |
| 30 | Supplying and fixing 20A, 240V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20A \\"C\\" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket outlet and complete with connections, testing and commissioning etc. as required. Make: Same as Item No:8 |
| 31 | Earthing with copper earth plate 600 mm x 600 mm x 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal / coke and salt as required. Note: Masonry enclosure size is 1.5 Feet x 1.5 Feet x 1.5 Feet. As per IS 3043, charcoal / coke and salt should be refilled with 50 Kg each per earthpit. The copper plate to be coated with tin; from the plate until to the funnel, to connect with 2 x copper flats using SS / Bronze nut, bolts and washers and brazing of the plate with GI Pipe. |
| 32 | Providing and laying earth connection from earth electrode with 4.00mm dia copper wire in 15mm G.I. pipefrom earth electrode including connection with copper thimble excavation and refilling as required. |
| 33 | Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing along with existing surface / recessed conduit / submain wiring / cable as required. |
| 34 | Providing and fixing earth bus of 50 mm X 5 mm copper strip on surface for connections etc. as required. |
| 35 | Supplying, Installation, Testing & Commissioning of LED Surface Mounted Batten 40 Watt light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85% ,Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 Deg C to 40 Deg C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P.F.≥0.95, IP20, CRI >80, Flicker free (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/Embossing/ Screen printing on housing complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body (Thickness >= 1.20 mm) . Make: Same as Item No:1. |
| 36 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of Above 35 sq. mm and upto 95 sq. mm direct in ground including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering. |
| 37 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of Above 35 sq. mm and upto 95 sq. mm (clamped with 25 x 3mm MS flat clamp) on wall surface as required. |
| 38 | Supplying and making end termination with brass compression gland and aluminium lugs for 4 X 50 sq. mm (35mm) size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. Note: Each means all 4 terminals of one end. Make: Please refer Special Electrical Conditions under Tender Document File. |
| 39 | Supplying and laying of 63mm dia (OD-63mm & ID-51mm nominal) DWC HDPE Pipe ISI marked along with all accessories like socket, bend, couplers etc, conforming to IS 14930, Part II complete with fitting and cutting, jointing etc., in the existing trench, complete as required. Make: Please refer Special Electrical Conditions under Tender Document File. |
| 40 | Supplying , Installation, Testing and Commissioning of 1.5 TR with 5 Star BEE Rating Air Cooled Hi Wall split type Air conditioners complete with Indoor unit (IDU), Outdoor unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU) i/c drain pipe R-32/R-410/ R-407 Green Refrigerant, wireless Remote control, suitable for working between 180-260V with low & high voltage cutoff and 50 hz ,1 phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotarycompressor. The system shall be able to deliver 100% of the rated capacity upto 42 0C. Min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB). Must comply : Electrical cable IS 694 or IS 9968 temperature sensingcontrol IS /International Electrotechnical Commission (IEC) 60730, hermetic compressor IS 10617, heat exchanger IS 11329, capacitor IS 2993 and motor IS 12615. Complete as per CPWD specification and IS : 1391 Part II 2023. The system shall be able to operate up to 50 0C (out door ambient temperature). Inverter Type - Cooling only. Make: Please refer Special Electrical Conditions under Tender Document File. |
| 41 | Supplying, Installation, Testing and Commissioning of 2.0 TR with 5 Star BEE Rating Air Cooled Hi Wall split type Air conditioners complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU) i/c drain pipe R-32/R-410/ R-407 Green Refrigerant, wireless Remote control, suitable for working between 180-260V with low & high voltage cutoff and 50 hz ,1 phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotarycompressor. The system shall be able to deliver 100% of the rated capacity upto 42 0C. Min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB). Must comply : Electrical cable IS 694 or IS 9968 temperature sensingcontrol IS /International Electrotechnical Commission (IEC) 60730, hermetic compressor IS 10617, heat exchanger IS 11329, capacitor IS 2993 and motor IS 12615. Complete as per CPWD specification and IS : 1391 Part II 2023. The system shall be able to operate up to 50 0C (out door ambient temperature). Inverter Type - Cooling only. Make: Same as Item No:40 |
| 42 | PART B: IT & NETWORKING (Item No:42 to 45) :- Supply, Fixing, Commissioning and Successful Installation of Cat 6 IO Module -Blue, Single Face Plate and 2 Module Back Box as required. Make: Dlink, Roma |
| 43 | Supply, Fixing, Commissioning and Successful Installation of following items with required hardwares as needed. a) 24 Port Loaded Patch Panel - 1 No, Make: Netfox / DLink / Molex / Digilink b) 24 Port L2 Poe Switch - 1 No, Make: Hp / Quantum / Cisco c) 9U Data Cabinet - 500D with Tray, PDU & Fan along with Cable Manager as required - 1 No. Make: Any ISI. |
| 44 | Supply and Successful Commissioning of Patch Cable as required. Make: Molex / Dglink / Dlink. |
| 45 | Supply, Laying and Successful Commissioning of CAT 6 UTP Cable and Laying inside suitable size Casing and Caping using suitable hardwares, end to end testing etc., as required. Make: Molex / Dglink / Dlink. Colour: White / Ivory. Please Enable Macros to View BoQ information |