Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Construction of Girls Hostel and VC Residence at Chaudhary Bansi Lal University, Prem Nagar, Bhiwani |
| 2 | Cost of Girls Hostel with Warden residence, boundary wall & allied works |
| 3 | Cost of VC residence & allied works TOTAL COST FOR GIRLS HOSTEL & VC RESIDENCE S. NO. DESCRIPTION AMOUNT WITHOUT GST (INR) REMARKS |
| 4 | Cost of Girls Hostel with Warden residence, boundary wall & allied works (without GST) |
| 5 | Cost of VC residence & allied works (without GST) Total Cost without GST (1+2) 0.0 ANNEXURE-A ABSTRACT OF COST FOR GIRLS HOSTEL S. NO. DESCRIPTION AMOUNT WITHOUT GST REMARKS |
| 6 | CIVIL WORKS I SUB HEAD I - EARTH WORKS 0.0 II SUB HEAD II - CONCRETE WORK 0.0 III SUB HEAD III - R.C.C WORKS 0.0 IV SUB HEAD IV - BRICK WORK 0.0 V SUB HEAD V - STONE WORK 0.0 VI SUB HEAD VI - FLOORING 0.0 VII SUB HEAD VII - FINISHING 0.0 VIII SUB HEAD VIII - WOOD WORK & PVC WORK 0.0 IX SUB HEAD IX- STEEL WORK 0.0 X SUB HEAD X- WATER PROOFING 0.0 XI SUB HEAD XI- ROAD WORK 0.0 XII SUB HEAD XII- NON SCHEDULE ITEMS 0.0 TOTAL CIVIL 0.0 |
| 7 | PLUMBING & FIREFIGHTING WORKS I SANITARY FIXTURES & CP BRASS FITTINGS 0.0 II SOIL, WASTE, VENT PIPE 0.0 III RAIN WATER PIPES 0.0 IV WATER SUPPLY SYSTEM 0.0 V SEWERAGE AND DRAINAGE 0.0 VI FIRE 0.0 TOTAL PLUMBING 0.0 |
| 8 | ELECTRICAL WORKS I DISTRIBUTION BOARDS 0.0 II POINT WIRING 0.0 III SUPPLY OF LIGHT FIXTURE AND FANS 0.0 IV DATA AND TELEPHONE NETWORK 0.0 V LT & HT CABLE 0.0 VI EARTHING AND MISCELLANEOUS ITEMS 0.0 VII LIGHTNING PROTECTION SYSTEM 0.0 VIII EARTHING STRIP 0.0 IX DISTRIBUTION BOARDS 0.0 X LIGHT FIXTURE 0.0 XI DATA AND TELEPHONE NETWORK 0.0 XII IP CCTV SYSTEM 0.0 XIII CSS, MAIN LT PANEL AND MAIN DISTRIBUTION BOARD 0.0 XIV EARTHING AND MISCELLANEOUS ITEMS 0.0 XV UPS 0.0 XVI DG SETS 0.0 XVII FIRE ALARM AND DETECTION SYSTEM 0.0 TOTAL ELECTRICAL 0.0 Grand TOTAL (Civil + Plumbing & Firefighting + Electrical ) without GST 0.0 ANNEXURE-1 CIVIL WORKS FOR GIRLS HOSTEL S. No. HSR2021/NS DESCRIPTION OF ITEM UNIT QTY ESTIMATED RATE WITHOUT GST (INR) QUOTED RATE WITHOUT GST (INR) AMOUNT OF ITEMS (INR) I SUB HEAD I - EARTH WORKS |
| 9 | 4.12 All kinds of soil cum 2984.08 77.68 0.0 |
| 10 | RM079 |
| 11 | 3.1.2 (i) 3.1.2 (ii) Carriage of earth beyond 5km upto 10 km Cum 250.0 31.25 0.0 3.1.2 (iii) Carriage of earth beyond 5km upto 15 km Cum 250.0 26.79 0.0 |
| 12 | 17.8.1 |
| 13 | 17.8.2 |
| 14 | 17.8.3 |
| 15 | 26.4.3 SUB TOTAL-I 0.0 II SUB HEAD II - CONCRETE WORK |
| 16 | 6.1 All works up to plinth level: 6.1.6 1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size) cum 371.22 2441.96 0.0 SUB TOTAL-II 0.0 III SUB HEAD III - R.C.C WORKS |
| 17 | 6.3 i 6.30.1 Foundations, footings, bases of columns, etc. for mass concrete sqm 716.34 156.25 0.0 ii 6.30.2 Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc. sqm 126.08 282.14 0.0 iii 6.30.3 Suspended floors, roofs, landings, balconies and access platform sqm 4089.61 208.04 0.0 iv 6.30.4 Shelves (Cast in situ) sqm 447.24 223.21 0.0 v 6.30.5 Lintels, beams, plinth beams, girders, bressumers and cantilevers sqm 4575.27 296.43 0.0 vi 6.30.6 Columns, Pillars, Piers, Abutments, Posts and Struts sqm 3099.58 261.61 0.0 |
| 18 | 6.33 6.33.6 Thermo-Mechanically Treated bars of grade Fe-500D or more. kg 145937.0 66.07 0.0 |
| 19 | 6.34 6.34.6 Thermo-Mechanically Treated bars of grade Fe-500D or more. kg 166960.0 67.86 0.0 |
| 20 | 6.25 (Note :- Cement content considered in this item is @ 330 kg/cum. Less cement used as per design mix is recoverable. However no extra payment shall be made if excess cement is used as per design mix). 6.25.1 All works upto plinth level Cum 1306.54 4463.39 0.0 6.25.2 All works above plinth level upto floor IV level Cum 1293.37 4500.89 0.0 |
| 21 | 6.26 (Note :- Less cement used as per design mix is recoverable. However no extra payment shall be made if excess cement is usedas per design mix). 6.26.1 Providing M-30 grade concrete instead of M-25 grade BMC/ RMC. (Note:- Cement content considered in M-30 is @ 340 kg/cum Cum 2249.5 58.93 0.0 6.26.2 Providing M-35 grade concrete instead of M-25 grade BMC/ RMC. (Note : Cement content considered in M-35 is @ 350kg/cum Cum 325.41 118.75 0.0 SUB TOTAL-III 0.0 IV SUB HEAD IV - BRICK WORK |
| 22 | 7.47 7.47.2 Cement mortar 1:6 (1 cement : 6 coarse sand) cum 1712.99 4070.54 0.0 |
| 23 | 7.48 7.48.1 Cement mortar 1:4 (1 cement : 4 coarse sand) cum 197.97 4131.25 0.0 |
| 24 | 7.31 7.31.2 Cement mortar 1:4 (1 cement :4 coarse sand) Sqm 988.57 474.11 0.0 |
| 25 | 7.3 SUB TOTAL-IV 0.0 V SUB HEAD V - STONE WORK |
| 26 | 8.26 Granite of any color and shade-Kitchen/Toilet Counters/sill/Coping 8.26.2.2 Area of slab over 0.50 sqm sqm 86.0 2775.89 0.0 |
| 27 | 8.27 8.27.2 Granite work-Kitchen/Toilets Counter meter 31.53 229.46 0.0 |
| 28 | 8.28 SUB TOTAL-V 0.0 VI SUB HEAD VI - FLOORING |
| 29 | 10.1 10.10.1 40 mm thick with 20 mm nominal size stone aggregate Sqm 140.58 267.86 0.0 |
| 30 | 10.29 10.29.2 Medium shade pigment using 50% white cement, 50% ordinary cement Sqm 8.37 792.86 0.0 |
| 31 | 10.5 10.50.1 Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent. sqm 654.31 2706.25 0.0 |
| 32 | 10.51 |
| 33 | 10.58 |
| 34 | 10.76 |
| 35 | 10.63 |
| 36 | 10.63.2 |
| 37 | 10.67 |
| 38 | 10.67.2 |
| 39 | 6.1.4 |
| 40 | 10.37 10.37.1 25 mm thick sqm 1026.0 790.18 0.0 |
| 41 | 10.38 |
| 42 | 10.107 SUB TOTAL-VI 0.0 VII SUB HEAD VII - FINISHING |
| 43 | 11.1 11.1.1 1:3 (1 cement : 3 fine sand) Sqm 4265.1 96.43 0.0 |
| 44 | 11.8 11.8.2 1:6 (1 cement: 6 coarse sand) (Raft and Internal; Walls) Sqm 12116.1 105.36 0.0 |
| 45 | 11.9 11.9.2 1:6 (1 cement: 6 coarse sand) Sqm 2123.79 127.68 0.0 |
| 46 | 11.18 |
| 47 | 11.74 11.74.2 Two coats Sqm 5246.62 38.39 0.0 |
| 48 | 11.82 11.82.1 Two or more coats on new work Sqm 1507.61 49.11 0.0 |
| 49 | 11.91 |
| 50 | 11.64 11.64.1 New work (two or more coats) over and including water thinnable priming coat with cement primer Sqm 10727.5 44.64 0.0 |
| 51 | 11.61 11.61.1 New work (three or more coats) sqm 491.46 13.39 0.0 |
| 52 | 11.96 11.96.1 New work (Two or more coats applied @ 1.43 litre/10 sqm over sqm 33 61 95and including priming coat of exterior primer applied @ 2.20kg/10 sqm) sqm 6148.27 84.82 0.0 |
| 53 | 11.58 |
| 54 | 11.54 |
| 55 | 11.67 11.67.1 Water thinnable cement primer sqm 3614.28 22.32 0.0 SUB TOTAL-VII 0.0 VIII SUB HEAD VIII - WOOD WORK & PVC WORK |
| 56 | 12.37 i 12.37.1 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws sqm 603.78 1400.0 0.0 ii 12.37.3 25 mm thick (for cupboard) including ISi marked nickel plated bright finished M.S. piano hinges with necessary screws Sqm 587.57 1316.07 0.0 |
| 57 | 12.39 |
| 58 | 12.12 12.12.2 1.0 mm thick sqm 1506.82 459.82 0.0 |
| 59 | 12.53 12.53.2 With 12 mm mild steel U beading sqm 26.25 505.36 0.0 |
| 60 | 12.98 i 12.98.1 300x16 mm each 10.0 200.89 0.0 ii 12.98.2 250x16 mm each 650.0 178.57 0.0 |
| 61 | 12.99 i 12.99.1 300X10mm each 461.0 95.54 0.0 ii 12.99.3 200X10mm each 237.0 72.32 0.0 |
| 62 | 12.102 12.102.1 125mm each 1258.0 49.11 0.0 |
| 63 | 12.103 12.103.1 Single rubber stopper each 345.0 27.68 0.0 |
| 64 | 12.105 |
| 65 | 12.157 12.157.1 For fixed portion 12.157.1.2 Powder coated aluminium (minimum thickness of powder coating 50 micron) Kg 11300.55 350.0 0.0 |
| 66 | 12.157.2 12.157.2.2 Powder coated aluminium (minimum thickness of powder coating 50 micron) Kg 5138.7 402.68 0.0 |
| 67 | 12.159 12.159.1 With float glass panes of 4.0 mm thickness (weight not less than 10kg/sqm) Sqm 285.45 666.96 0.0 |
| 68 | 12.171 |
| 69 | 12.89 |
| 70 | 12.37 SUB TOTAL-VIII 0.0 IX SUB HEAD IX- STEEL WORK PRE-PAINTED / POWDER COATED GALVANISED SHEET DOOR/WINDOW FRAMES AND WINDOW SHUTTERS |
| 71 | 13.29 13.29.1 In stringers, treads, landings etc. of stair cases, including use of chequered plate wherever required, all complete 13.29.2 In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works(Staircase Railing,Fencing Frame,shed at cooking area) kg 15306.62 83.04 0.0 |
| 72 | 13.5 i 13.5.2 10 x 80 mm-For Fixing MS Railings each 5109.44 63.39 0.0 ii 13.5.3 10 x 120 mm each 1242.0 77.68 0.0 |
| 73 | 13.4 13.4.2 Fixing with carbon steel galvanised dash fastener of required dia and size (to be paid for separately) kg 3164.94 94.64 0.0 |
| 74 | 13.35 SUB TOTAL-IX 0.0 X SUB HEAD X - WATER PROOFING |
| 75 | 28.15 WATERPROOFING TREATMENT TO TERRACE AREA USING TWO COMPONENT 100% SOLIDS HYBRID POLYUREA COATING |
| 76 | 28.17 28.17.1 With average thickness of 120 mm and minimum thickness at sqmkhurra as 65 mm. sqm 1458.36 664.29 0.0 |
| 77 | 28.18 |
| 78 | 28.2 i 28.20.1 For vertical surface two coats @ 0.70 kg per sqm Sqm 72.71 398.21 0.0 ii 28.20.2 For horizontal surface one coat @1.10 kg per sqm Sqm 203.56 310.71 0.0 SUB TOTAL-X 0.0 XI SUB HEAD XI - ROAD WORK |
| 79 | 17.5.3 |
| 80 | 17.14 i 17.14.3 Grading Ill material Cum 358.97 1196.43 0.0 |
| 81 | 6.1 6.1.6 1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size) Cum 155.95 2441.96 0.0 KERB STONE WORK |
| 82 | 6.39 6.39.1 1:1½ :3 (1 Cement: 1½ coarse sand(zone-111) : 3 cumgraded stone aggregate 20 mm nominal size). Cum 22.75 4134.82 0.0 |
| 83 | 10.77 |
| 84 | 16.53 |
| 85 | 6.34.6 |
| 86 | 17.45 SUB TOTAL-XI 0.0 XII SUB HEAD XII -Non Scheduled Items |
| 87 | NS-2 Size of Tile 600x600 mm (Toilet) sqm 603.55 875.42 0.0 |
| 88 | N.S-3 i Glass door shutter set 4.0 2878.81 0.0 |
| 89 | N.S-4 |
| 90 | N.S-5 |
| 91 | N.S-6 |
| 92 | N.S-7 i Single Leaf & Double Leaf & Door Size as per approved drawing sqm 110.22 6421.19 0.0 |
| 93 | N.S-8 |
| 94 | N.S-9 |
| 95 | NS-10 |
| 96 | NS-11 |
| 97 | NS-12 |
| 98 | NS-13 |
| 99 | NS-14 |
| 100 | NS-15 |
| 101 | NS-16 |
| 102 | NS-17 |
| 103 | NS-18 SUB TOTAL-XII 0.0 ANNEXURE-2 PLUMBING & FIRE FIGHTING WORKS FOR GIRLS HOSTEL S. No. HSR2021/NS DESCRIPTION OF ITEM UNIT QTY ESTIMATED RATE WITHOUT GST (INR) QUOTED RATE WITHOUT GST (INR) AMOUNT OF ITEMS (INR) I Sanitary Fixtures & CP Brass Fittings |
| 104 | 22.32 22.32.1 White vitreous chinaware dual purpose WC pan with white solid plastic seat and lid with white vitreous chinaware flushing cistern and C.P. flush bend. Each 12.0 6508.04 0.0 |
| 105 | 22.1 22.1.2 White vitreous chinaware Wash basin size 630x450 mm with a single 15 mm C.P. brass pillar tap Each 3.0 1767.86 0.0 |
| 106 | 22.2 22.2.1 White vitreous chinaware Wash basin size 550x400 mm with a 15 mm CP Brass single hole basin mixer Each 17.0 3186.61 0.0 |
| 107 | 22.1 22.10.1 Kitchen sink with drain board i 22.10.1.1 510x1040 mm bowl depth 250 mm Each 3.0 3718.75 0.0 22.10.2 Kitchen sink without drain board ii 22.10.2.1 610x510 mm bowl depth 200 mm Each 2.0 2619.64 0.0 |
| 108 | 22.14 22.14.2 Flexible pipe i 22.14.2.1 32 mm dia Each 4.0 56.25 0.0 |
| 109 | 22.15 |
| 110 | 22.22 22.22.1 White vitreous chinaware Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests Each 3.0 3491.96 0.0 |
| 111 | 22.24 22.24.1 W.C. pan with ISi marked white solid plastic seat and lid Each 47.0 4385.71 0.0 |
| 112 | 22.42 22.42.1 C.P. brass Each 47.0 389.29 0.0 |
| 113 | 22.105 22.105.1 15 mm nominal bore Each 162.0 511.61 0.0 |
| 114 | 22.108 22.108.1 15mm nominal bore Each 253.0 443.75 0.0 |
| 115 | 22.118 |
| 116 | 22.127 |
| 117 | 22.128 22.128.2 15 mm nominal bore with 45 cm length Each 82.0 76.79 0.0 |
| 118 | 22.212 22.212.1 C.P Brass 22.212.1.3 Three Way Per Set 100.0 134.82 0.0 |
| 119 | i 22.216.1 25 Litres capacity each 21.0 8085.71 0.0 ii 22.216.3 35 Litres capacity each 40.0 10403.57 0.0 |
| 120 | 22.209 |
| 121 | 22.212 22.212.1 Aluminium coat and hat hooks 22.212.2.3 Three Way each 115.0 163.39 0.0 |
| 122 | NS-6 SUB TOTAL HEAD-(I) 0.0 II Soil, Waste, Vent Pipe |
| 123 | 22.222 i 22.222.2 Single Socket Type B ii 22.222.2.2 110mm old SWR UPVC pipe lines laid complete Meter 753.0 322.32 0.0 iii 22.222.2.4 75mm old SWR UPVC pipe lines laid complete Meter 40.0 241.96 0.0 |
| 124 | NS-7 i 40 mm O.D. Meter 29.0 194.92 0.0 ii 50 mm O.D. Meter 56.0 355.08 0.0 iii 63 mm O.D. Meter 132.0 421.19 0.0 |
| 125 | NS-10 |
| 126 | NS-11 |
| 127 | 22.53 i 2.53.1 For 100 mm dia pipe Each 72.0 144.64 0.0 ii 2.53.2 For 75 mm dia pipe Each 12.0 141.07 0.0 SUB TOTAL HEAD-(II) 0.0 III Rain Water Pipes |
| 128 | NS-12 i PVC pipe 75mm-6 kg/cm2 Meter 891.0 381.36 0.0 ii PVC pipe 110mm-6 kg/cm2 Meter 24.2 616.1 0.0 iii PVC pipe 160mm-6 kg/cm2 Meter 177.1 1159.32 0.0 |
| 129 | NS-13 SUB TOTAL HEAD-(III) 0.0 IV Water Supply System |
| 130 | 22.86 i 22.86.1 15 mm nominal outer dia Pipes Meter 118.8 205.36 0.0 ii 22.86.2 20 mm nominal outer dia Pipes Meter 712.6 264.29 0.0 iii 22.86.3 25 mm nominal outer dia Pipes Meter 52.2 333.04 0.0 iv 22.86.4 32 mm nominal outer dia Pipes Meter 5.0 428.57 0.0 |
| 131 | 22.85 i 22.85.1 15 mm nominal outer dia Pipes Meter 5.0 130.36 0.0 ii 22.85.2 20 mm nominal outer dia Pipes Meter 534.0 181.25 0.0 iii 22.85.3 25 mm nominal outer dia Pipes Meter 335.0 233.04 0.0 iv 22.85.4 32 mm nominal outer dia Pipes Meter 92.0 310.71 0.0 v 22.85.5 40 mm nominal outer dia Pipes Meter 42.0 429.46 0.0 vi 22.85.6 50 mm nominal outer dia Pipes Meter 180.0 648.21 0.0 |
| 132 | NS-14 |
| 133 | NS-15 |
| 134 | NS-16 |
| 135 | 22.87 22.87.6 50 mm nominal outer dia Pipes Meter 183.0 591.96 0.0 |
| 136 | NS-17 65 mm dia nominal bore Meter 81.7 436.44 0.0 |
| 137 | 22.91 22.91.6 65 mm dia nominal bore Meter 183.0 406.25 0.0 |
| 138 | NS-18 i 15 mm nominal bore Each 7.0 471.19 0.0 ii 20 mm nominal bore Each 37.0 638.14 0.0 iii 25 mm nominal bore Each 27.0 994.07 0.0 iv 32 mm nominal bore Each 7.0 1641.53 0.0 v 40 mm nominal bore Each 8.0 2377.12 0.0 |
| 139 | NS-19 6 mm thick for hot water pipes in wall chases i 15mm dia nominal bore Meter 287.2 89.83 0.0 ii 20mm dia nominal bore Meter 8.4 98.31 0.0 iii 25mm dia nominal bore Meter 7.0 109.32 0.0 |
| 140 | NS-20 50 mm nominal bore Each 4.0 8665.25 0.0 |
| 141 | 25.3 i 25.3.6 100mm dia Each 1.0 2663.39 0.0 ii 25.3.7 80mm dia Each 1.0 2029.46 0.0 iii 25.3.8 65mm dia Each 6.0 1821.43 0.0 iv 25.3.9 50mm dia Each 8.0 1584.82 0.0 |
| 142 | 25.6 i 25.6.4 100mm dia. Each 1.0 4175.0 0.0 ii 25.6.5 80mm dia. Each 1.0 3433.04 0.0 |
| 143 | 22.181 SUB TOTAL HEAD-(IV) 0.0 V Sewerage and Drainage |
| 144 | 4.16 4.16.1 All kinds of soil i 4.16.1.2 Pipes, cables etc. exceeding 80 mm metredia. but not exceeding 300 mm dia Meter 528.0 64.29 0.0 ii 4.16.1.3 Pipes, cables etc. exceeding 300 mm metredia but not exceeding 600 mm Meter 205.0 131.25 0.0 |
| 145 | NS-21 i 150 mm diameter Meter 61.0 363.56 0.0 ii 200 mm diameter Meter 304.0 424.58 0.0 |
| 146 | 22.164 22.164.2 150 mm diameter S.W. pipe Meter 61.0 396.43 0.0 22164.3 200 mm diameter S.W. pipe Meter 304.0 462.5 0.0 |
| 147 | NS-22 i 160 x 110 mm size P type With sewer bricks conforming to IS : 4885 Each 37.0 3961.0 0.0 |
| 148 | NS-23 i 200 mm dia RCC pipes Meter 172.0 745.76 0.0 ii 300 mm dia RCC pipes Meter 215.0 1079.66 0.0 |
| 149 | 22.206 22.206.1 With common burnt clay non-modular bricks of class designation 7.5 Each 69.0 3281.25 0.0 |
| 150 | 22.19 22.190.1 Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) : 22.190.1.2 With Sewer bricks conforming to IS : 4885 Each 54.0 6597.32 0.0 |
| 151 | 22.191 22.191.1 Size 90x80 cm |
| 152 | 22.191.1.2 |
| 153 | 22.198 22.198.2 With 20 mm diameter round bar Each 133.0 207.14 0.0 SUB TOTAL HEAD-(V) 0.0 VI FIRE FIGHTING SYSTEM |
| 154 | NS-24 i 150 mm width x 50mm depth x 1.6 mm thickness. Metre 15.0 511.86 0.0 |
| 155 | NS-25 |
| 156 | NS-26 i 25 mm dia Metre 26.0 630.51 0.0 ii 32 mm dia Metre 3.0 721.19 0.0 iii 40 mm dia Metre 3.0 876.27 0.0 iv 50 mm dia Metre 3.0 1086.44 0.0 v 65 mm dia Metre 122.0 1367.8 0.0 vi 80 mm dia Metre 11.0 1597.46 0.0 |
| 157 | NS-27 65 mm dia Set 4.0 3645.76 0.0 |
| 158 | NS-28 65mm dia Set 1.0 5438.98 0.0 |
| 159 | NS-29 20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 12585 20 mm nominal internal dia gun metal globe valve & nozzle. Drum and brackets for fixing the equipmets on wall. Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket. 18.17.2 40 m Set 1.0 10231.36 0.0 |
| 160 | NS-30 2 way - 100 mm dia M.S. Pipe Set 1.0 5713.56 0.0 |
| 161 | NS-31 |
| 162 | NS-32 a) Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical confirming to IS : 1520 b) Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase, 50 Hz, AC supply with IP55 class of protection for enclosure, horiziontal foot mounted type with Class-'F' insulation, conforming to IS-325. c) M.S.fabricated common base plate, coupling, coupling guard, foundation bolts etc.as required. d) Suitable cement concrete foundation duly plastered and with anti vibration pads. 450 lpm at 35 m Head Each 1.0 73053.39 0.0 |
| 163 | NS-33 25 mm dia Each 1.0 1628.81 0.0 |
| 164 | NS-34 Capacity 6.0 Kg. Each 20.0 4162.71 0.0 |
| 165 | NS-35 |
| 166 | NS-36 Capacity 4.5 kg. Each 1.0 10130.51 0.0 |
| 167 | NS-37 Set 1.0 192753.39 0.0 SUB TOTAL HEAD-(VI) 0.0 ANNEXURE-3 ELECTRICAL WORKS FOR GIRLS HOSTEL S. No. HSR2021/NS DESCRIPTION OF ITEM UNIT QTY ESTIMATED RATE WITHOUT GST (INR) QUOTED RATE WITHOUT GST (INR) AMOUNT OF ITEMS (INR) I DISTRIBUTION BOARDS (HSR Items) |
| 168 | 23.22.4 i 23.22.4.3 SPN DB Double Door 12 way ( 2 incoming and 10 outgoing) Each 5.0 1705.36 0.0 ii 23.22.4.4 SPN DB Double Door 16 way ( 2 incoming and 14 outgoing) Each 2.0 2079.46 0.0 i 23.22.4.7 TPN DB Horizontal type Double Door 8 way ( 8 incoming3phase*8 outgoing) Each 11.0 3957.14 0.0 iv 23.22.4.8 TPN DB Horizontal type Double Door 12 way ( 8 incoming3phase*12 outgoing) Each 8.0 5754.46 0.0 |
| 169 | 23.22.5 i 23.22.5.1 6 amp. to 32 amp Single Pole Each 472.0 144.64 0.0 ii 23.22.5.3 6 amp. to 32 amp Double POLE Each 7.0 425.89 0.0 iii 23.22.5.8 40 amp to 63 amp. MCB's FOUR POLE Each 19.0 1291.07 0.0 |
| 170 | 23.22.6 i 23.22.6.1 DP RCCB 30ma sensitivity , 25 A Each 7.0 1477.68 0.0 ii 23.22.6.2 DP RCCB 30ma sensitivity , 40 A Each 27.0 1669.64 0.0 iii 23.22.6.3 DP RCCB 30ma sensitivity , 63 A Each 30.0 2075.0 0.0 |
| 171 | 23.22.7 SUB TOTAL-I 0.0 II CIRCUIT CUM POINT WIRING (HSR ITEMS) |
| 172 | 23.4.1 23.4.1.1 Group A Point 961.0 519.64 0.0 |
| 173 | 23.4.3 23.4.3.1 Group A Point 320.0 225.0 0.0 |
| 174 | 23.4.4 23.4.4.1 Group A Each 572.0 725.0 0.0 |
| 175 | 23.4.5 23.4.5.3 Group A Each 92.0 999.11 0.0 |
| 176 | 23.3.6 i. 23.3.6.9 3 run of Size 1.50 Sqmm(1/1.40mm) Mtr. 1600.0 189.29 0.0 ii. 23.3.6.10 3 run of Size 2.50 Sqmm(1.1.80mm) Mtr. 3650.0 271.43 0.0 iii 23.3.6.8 2 run of Size 4 Sqmm(1/2.24mm) Mtr. 3650.0 258.93 0.0 iii 23.3.6.3 1 run of Size 4 Sqmm(1/2.24mm) Mtr. 3650.0 143.75 0.0 iv 23.3.6.4 1 run of Size 6 Sqmm(1/2.80mm) Mtr. 2610.0 172.32 0.0 v 23.3.6.5 1 run of Size 10 Sqmm(1/3.50 mm) Mtr. 1600.0 345.54 0.0 |
| 177 | 23.7.6 i 23.7.6.1 PVC pipe of 20 mm dia. Mtr. 1100.0 25.89 0.0 ii 23.7.6.2 PVC pipe of 25 mm dia. Mtr. 4650.0 32.14 0.0 iii 23.7.6.3 PVC pipe of 32 mm dia. Mtr. 220.0 44.64 0.0 iv 23.7.6.4 PVC pipe of 40 mm dia. Mtr. 100.0 57.14 0.0 |
| 178 | 23.8.11 i 23.8.11.6 Bell Push Each 3.0 76.79 0.0 ii 23.8.11.7 step type Fan Regulator 2 modules 300 watt Each 186.0 257.14 0.0 |
| 179 | 23.8.4 SUB TOTAL-II 0.0 III FIXING OF LIGHT FIXTURE & FAN (HSR Items) |
| 180 | 23.21 |
| 181 | 23.11 SUB TOTAL-III 0.0 IV DATA AND TELEPHONE NETWORK |
| 182 | 23.23.10 |
| 183 | 23.8.10 23.8.10.1 1 & 2 Modules including combined plate for Telephone and data Each 226.0 92.86 0.0 |
| 184 | 23.8.11 i 23.8.11.8 Telephone Socket outlet modular type Each 8.0 75.0 0.0 ii 23.8.11.9 TV Socket outlet modular type Each 3.0 75.0 0.0 iii 23.8.11.11 RJ 45 Computer DATA socket outlet for CAT 6 or CAT6e cable Modular type Each 215.0 303.57 0.0 |
| 185 | 23.23.8 23.23.8.1 2 pair telephone wire Metre 170.0 7.14 0.0 SUB TOTAL-IV 0.0 V HT & LT CABLE (HSR Items) |
| 186 | 24.3.1 24.3.1.2 above 120 and up to 300 sqmm 3 core XLPE Cable metre 750.0 183.04 0.0 |
| 187 | 24.3.3 24.3.3.3 300 to 400 sqmm Each 3.0 10278.57 0.0 |
| 188 | 24.3.5 24.3.5.4 300 to 400 sqmm Each 1.0 38367.86 0.0 |
| 189 | 24.2.6 24.2.6.5 10 sqmm Each 48.0 8.93 0.0 |
| 190 | 24.2.7 i 24.2.7.2 1O sqmm to 16s qmm Cable 2 to 4 Core Each 48.0 44.64 0.0 ii 24.2.7.3 25 sqmm to 50 sqmm Cable 2 to 4 Core Each 12.0 76.79 0.0 iii 24.2.7.4 70 sqmm to 95 sqmm Cable 3 to 3½ Core Each 2.0 103.57 0.0 iv 24.2.7.5 120 sqmm to 185 sqmm Cable 3 to 32 Core Each 4.0 133.04 0.0 v 24.2.7.7 300 sqmm to 400 sqmm Cable 3 to 3½ Core Each 4.0 226.79 0.0 |
| 191 | 24.2.8 i 24.2.8.3 10 sqmm Each 36.0 6.25 0.0 ii 24.2.8.5 25sqmm Each 48.0 9.82 0.0 iii 24.2.8.7 50sqmm Each 2.0 15.18 0.0 iv 24.2.8.9 95sqmm Each 10.0 23.21 0.0 v 24.2.8.11 150 sqmm Each 4.0 40.18 0.0 vi 24.2.8.12 185 sqmm Each 12.0 49.11 0.0 vii 24.2.8.14 300sqmm Each 12.0 91.07 0.0 |
| 192 | 24.2.2 i 24.2.2.1 2.5 Sq mm to 10 Sq mm 2 to 4 Cor Metre 350.0 156.25 0.0 ii 24.2.2.2 16 Sq mm to 35 sqmm 2 to 4 Core Metre 250.0 160.71 0.0 iii 24.2.2.3 50 Sq mm to 150 sqmm 2 to 4 Core Metre 171.43 0.0 iv 24.2.2.4 185 sqmm to 240 sqmm 3 to 3½ Core Metre 60.0 177.68 0.0 v 24.2.2.5 300 sqmm to 400 sqmm 3 to 3½ Core Metre 200.0 185.71 0.0 |
| 193 | 24.2.3 24.2.3.2 16 Sq mm to 35 sqmm 2 to 4 Core Metre 250.0 48.21 0.0 |
| 194 | 24.2.4 i 24.2.4.1 2.5 Sq mm to 10 Sq mm 2 to 4 Core Metre 170.0 8.93 0.0 ii 24.2.4.2 16 Sq mm to 35 sqmm 2 to 4 Core Metre 50.0 12.5 0.0 |
| 195 | 24.2.5 i 24.2.5.1 2.5 Sq mm to 10 Sq mm 2 to 4 Core Metre 80.0 11.61 0.0 ii 24.2.5.2 16 Sq mm to 35 sqmm 2 to 4 Core Metre 100.0 20.54 0.0 iii 24.2.5.3 50 Sq mm to 150 sqmm 2 to 4 Core Metre 35.0 31.25 0.0 |
| 196 | 24.4.8 24.4.8.4 6 Metre Long pole with top dia 75 mm and bottom dia 150 mm each 15305with base plate of size 275 x 275 x 16 mm each 18.0 13665.18 0.0 |
| 197 | 24.4.2 24.4.2.2 90 cm long, with 20 cm high suitable size pole cap each 18.0 485.71 0.0 24.4.5 Supply and erection of Single Phase weather proof M.S. box of size 20 cm x each 64015 cm x 10 cm with hinged cover made of 2 mm thick MS sheet, lockingarrangements, housed in wall/fixed on pole , including the cost of 1 no 4 way16 A Bakelite connector, 1 no. 6 amp SP MCB and 1 Nos. 16 amp. neutrallinks fixed on Bakelite sheet in the M.S. box including painting andnecessary connections each 18.0 571.43 0.0 24.4.7 Supplying and embedding following dia G.I. pipe (medium class) in polecollar/ foundation (during casting) for cable entry including bending the pipeto the required shape complete as required. 24.4.7.1 32 mm dia each 36.0 280.36 0.0 |
| 198 | 24.5.2 i 24.5.2.3 DWC/HDPE pipe 63/50 mm outer dialinner dia Mtr 360.0 124.11 0.0 ii 24.5.2.7 DWC/HDPE pipe 180/150 mm outer dialinner dia Mtr 19.0 342.86 0.0 |
| 199 | 24.16 24.16.9 300 Sq mm 3 core Metre 800.0 2149.11 0.0 |
| 200 | 24.13 i 24.13.94 300 Sq mm 3.5 Core (Arm.) Metre 700.0 1574.11 0.0 ii 24.13.82 185 Sq mm 3.5 Core (Arm.) Metre 70.0 1010.71 0.0 iii 24.13.62 95 Sq mm 3.5 Core (Arm.) Metre 35.0 560.71 0.0 |
| 201 | 24.14 i 24.14.62 95 Sq mm 3.5 Core (Arm.) Metre 35.0 571.43 0.0 ii 24.14.32 25 Sq mm 4 Core (Arm.) Metre 700.0 225.89 0.0 iii 24.14.14 10 Sq mm 2 Core (Arm.) Metre 350.0 125.0 0.0 iv 24.14.18 10 Sq mm 4 Core (Arm.) Metre 180.0 150.89 0.0 SUB TOTAL -V 0.0 VI EARTHING AND MISCELLANEOUS ITEMS. (HSR Items) |
| 202 | 24.1.1 |
| 203 | 24.1.2 |
| 204 | 24.1.3 |
| 205 | 24.1.4 |
| 206 | 24.1.5 |
| 207 | 24.1.10 |
| 208 | 24.1.13 |
| 209 | 23.23.6 i 23.23.6.2 MS perforated cable tray painted with powder coating 200 X 50 X2mm Metre 60.0 350.89 0.0 ii 23.23.6.3 MS perforated cable tray painted with powder coating 375 X 50 X2mm Metre 50.0 397.32 0.0 SUB TOTAL VI 0.0 VII LIGHTNING PROTECTION SYSTEM |
| 210 | 24.1.16 SUB TOTAL VII 0.0 VIII Earthing Strip |
| 211 | 24.1.14 |
| 212 | 24.1.17 SUB TOTAL VIII 0.0 IX DISTRIBUTION BOARDS |
| 213 | NS-1 i Supplying and fixing of 63A 415V, 4P MCCBs of 50kA with thermal based release having O/L, S/C protection in sheet enclosure including drilling holes on the wall/ board complete with connection, earthing the body etc. as required. Set 1.0 13672.03 0.0 ii Supply, fixing and commissioning of the 32A 3Pin 2P+E IP65 weather proof socket and Plug complete as required. Set 2.0 6266.1 0.0 |
| 214 | NS-6 SUB TOTAL-(IX) 0.0 X LIGHT FIXTURE |
| 215 | NS-10 |
| 216 | NS-11 |
| 217 | NS-12 |
| 218 | NS-13 |
| 219 | NS-14 Supply of 900 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor. Each 4.0 3050.85 0.0 |
| 220 | NS-15 |
| 221 | NS-15.1 SUB TOTAL (X) 0.0 XI DATA AND TELEPHONE NETWORK SECTION - I- STRUCTURED CABLING SYSTEM PASSIVE |
| 222 | NS-16 |
| 223 | NS-17 |
| 224 | NS-18 |
| 225 | NS-19 |
| 226 | NS-20 |
| 227 | NS-21 |
| 228 | NS-22 |
| 229 | NS-23 |
| 230 | NS-24 |
| 231 | NS-25 |
| 232 | NS-26 |
| 233 | NS-27 |
| 234 | NS-28 |
| 235 | NS-29 SECTION - IP-PBX SYSTEM |
| 236 | NS-30 |
| 237 | NS-31 SECTION - Wi-Fi SYSTEMS |
| 238 | NS-32 |
| 239 | NS-33 |
| 240 | NS-34 SUB TOTAL -(XI) 0.0 XII IP CCTV SYSTEM |
| 241 | NS-35 |
| 242 | NS-36 |
| 243 | NS-37 |
| 244 | NS-38 |
| 245 | NS-39 |
| 246 | NS-40 |
| 247 | NS-41 |
| 248 | NS-42 SUB TOTAL-(XII) 0.0 XIII CSS, MAIN LT PANEL AND MAIN DISTRIBUTION BOARD |
| 249 | NS-43 Supplying installation, testing and commissioing of Outdoor type Package Substation with facility for internal lighting, earthing, padlocks etc. Connection between Circuit breaker & transformer with 1 no. 3Cx185 sq.mm. XLPE cable/Busbar and connections from transformer to LT ACB with bus bars with Cable termination kits consisiting of followings and as per the specifications: 3 Way, 11kV, indoor free standing metal clad insulated main 630A VCB (vaccum circuit breaker) with isolator as incomers on incoming and VCB on Transformer feeder suitable for fault making/load breaking complete with all accessories as listed below Microprocessor RELAY for Circuit Breakers – Self Powered SF6 Gas pressure indicator Padlocking facility The Breaker terminals suitable for 3C x 300 sq. mm 11 K.V. XLPE Cable for incomers and Bus bar connection. 3 Nos. Resin cast CTs with 20-10/ 5-5A 10VA class 0.5 accuracy. Set of Resin cast draw out type PTs with 11KV/R3/110V/R3 50VA Class 0.5 accuracy and H.T. Fuse & L.T. MCB. 3 phase 50 Hz 250 KVA DYn11 double wound with copper conductor, oil type distribution transformer having a no load voltage ratio of 11/0.415KV . OFF load tap changer Tappings +5% to – 15% in steps of 2.5% each with following accessories. Oil Temperature Indicator. 8 Window Annunciator with fault acceptance & reset, alarm etc. Winding temperature indication for all three phases Separate neutral bushing for earthing. Double float Buchholtz relay with alarm and trip for Transformer. All internal wiring between different compartments. Proper lighting inside the cubicale. Proper door lock and key. All H.T and L.T cable termination Complete earthing of compact sub station and Neutral and body.. 1 no. TPN surge protection device of Class 1 & 2. INCOMER 1 No. 4 pole 630A ACB (50 kA) & thermal magnetic release. The ACB Terminals shall be suitable for cable connection on outgoing side and direct bus bar connection for Bus Bar. Set 1.0 2221695.76 0.0 |
| 250 | NS-44 MAIN LT PANEL Supplying, installation, testing and commissioning of 415V, 3 Phase, 50 Hz., 4 wire system, sheet steel clad, dust and vermin proof cubical and Indoor type floor mounted, free standing type Main LT Panel with IP - 42 protection, compartmentalized design and fabricated out of 2 mm / 1.6 mm CRCA sheet steel complete with Aluminium Bus bars, Electrical interlocks as per the various status of all the equipments indicated on the drawings. Providing & Fixing of base plate / channel, P/F the following Switchgears, complete with earth Bus bar throughout the length of the panel, terminal arrangement for Incomings / Outgoings cables and also outgoing terminations for various sizes of cables, The incoming and outgoing feeders shall be accommodated in a modular multi-tier arrangement, adequate size bus duct/cable alley, Sign writing, Painting, Earthing, Numbering, Danger plate etc. complete as required as per specifications and drawing. MAIN LT PANEL INCOMING: 1 no. 630A 415V, 4P 50kA EDO ACB with Microprocessor based release having O/L, S/C/ , E/F, RPR , O/V, U/V Protection and ON /OFF/TRIP Indications with MCB. 1 no. Digital type Multifunction Meters to show (V, A, kWh, KVAh, KW, KVA, KVAR, PF, Hz.) with cast resin CTs. 1 Set of LED phase indicating lamps with MCB protection. 1 no. Trip Circuit Supervision relays. 1 no. TPN surge protection device of Class 1 & 2. 1 no. Electronic type Auto matic power factor correction relay with communication port. 1 no. 12.5kVAR capacitor bank with 32A TP MCCB of 36kA and ON, OFF, TRIP Indicating lamps. BUSBARS: 1 Set of TPN aluminium bus bar of minimum of 800 A capacity with heat shrinkable coloured sleeves and i/c DMC/SMC bus bars supports at required intervals complete for cross section, size supports & their spacing etc, for withstanding fault level of 50 KA for 1 Sec. OUTGOING ON BUS SECTION 2 nos. 400A 415V, TP+Neutral Link MCCB of 35kA with O/L and S/C protection and a set of CT's., Multi Function meter (V+A+Hz.) 1 no. 250A 415V, TP+Neutral Link MCCB of 35kA with O/L and S/C protection and a set of CT's., Multi Function meter (V+A+Hz.) 3 nos. 100A 415V, TP+Neutral Link MCCB of 35kA with O/L and S/C protection and a set of CT's., Multi Function meter (V+A+Hz.) 2 nos. 63A 415V, TP+Neutral Link MCCB of 35kA with O/L and S/C protection and a set of CT's., Multi Function meter (V+A+Hz.) CAP. PANEL (62.5 kVAR) INCOMER 1 no. 125A 415V, 4P MCCB of 25kA with O/L, S/C and E/F Protection with O/V, U/V protection, ON /OFF/TRIP Indications with MCB 1 no. Digital type Multifunction Meters to show (V, A, PF, Hz.) with CT. 1 Set of LED phase indicating lamps with 6 Amp. MCB protection. BUSBARS: 1 Set of TPN aluminium bus bar of minimum of 300A capacity with heat shrinkable coloured sleeves and i/c DMC/SMC bus bars supports at required intervals complete for cross section, size supports & their spacing etc, for withstanding fault level of 50KA for 1 Sec. OUTGOING 1 no. 25kVAR capacitor bank with 63A TP MCCB of 36kA and Contactor, one set of indicating Lights and Push Buttons. 1 no. 10kVAR capacitor bank with 25A TP MCCB of 25kA and Contactor, one set of indicating Lights and Push Buttons. 3 nos. 5kVAR capacitor bank with 16A TP MCCB of 25kA and Contactor, one set of indicating Lights and Push Buttons. Set 1.0 683599.15 0.0 |
| 251 | NS-45 i Supplying of 415V, 3 Phase, 50 Hz., 4 wire system, sheet steel clad, dust and vermin proof cubical and indoor type floor mounted, free standing Main Distribution Board with IP - 42 protection, compartmentalized design and fabricated out of 2 mm / 1.6 mm CRCA sheet steel complete with Aluminium Bus bars, Providing & Fixing of base plate / channel, P/F the following Switchgears, complete with earth Bus bar throughout the length of the panel, terminal arrangement for Incomings / Outgoings cables and also outgoing terminations for various sizes of cables, The incoming and outgoing feeders shall be accommodated in a modular multi-tier arrangement, adequate size bus duct/cable alley, Sign writing, Painting, Earthing, Numbering, Danger plate etc. complete as required as per specifications and drawing. i MDB LIGHT + LIFT (DG SUPPLY) GROUND FLOOR LOCATED IN EL. ROOM (GIRL HOSTEL) INCOMER : 1 no. 250A, 415V, Ics=35kA, 4P MCCB with thermal magnetic trip unit. 1 no. Digital multifunction meter (V+A+Hz) with a set of cast resin CTs 250/5A and communication port. 1 set of Phase indicating lamp with MCB 1 no. TPN surge protection device of Class 1 & 2. BUS BARS: 400A TPN bus bars of aluminium alloy. OUT GOING: 4 nos. 63A, 415V, Ics=25kA, TP +Neutral Link MCCB with thermal magnetic trip unit. 6 nos. 63A, 415V, 4P MCB of 10kA. 5 nos. 40A, 415V, 4P MCB of 10kA. 4 nos. 32A, 415V, 4P MCB of 10kA. AMF LOGIC FOR 1 No. 100 KVA DG Set part of the MDB LIGHT + LIFT. Supply fixing testing and commissioning of Auto Main Failure including auto by-pass panel for the 100 KVA DG set as per specification and requirement. Auto/Manual/Test/Off selector switch Energy analyzer unit to indicate current voltage frequency power factor and KWH Fuse for instruments Battery charger complete with transformer/rectifier, D.C. voltmeter and ammeter, selector switch for trickle, off and boost and current adjustment. Mains supply failure monitor Supply failure timer Restoration timer Control unit with three impulse automatic engine start/stop and failure to start lockout. Impulse counter with locking and reset facility. ON/OFF/Control circuit switch with indicator Audio/Video annunciation for High water temperature Low lubricating oil pressures Engine over speed Engine fails to start The above panel shall be complete as per specification and Single line diagram. Set 1.0 398766.1 0.0 |
| 252 | ii INCOMER : 1 no. 400A, 415V, Ics=35kA, 4P MCCB with thermal magnetic trip unit. 1 no. Digital multifunction meter (V+A+Hz) with a set of cast resin CTs 400/5A and communication port. 1 set of Phase indicating lamp with MCB 1 no. TPN surge protection device of Class 1 & 2. BUS BARS: 600A TPN bus bars of aluminium alloy. OUT GOING: 4 nos. 100A, 415V, Ics=25kA, TP +Neutral Link MCCB with thermal magnetic trip unit. 5 nos. 63A, 415V, 4P MCB of 10kA. Set 1.0 136719.49 0.0 |
| 253 | iii INCOMER : 1 no. 100A, 415V, Ics=35kA, 4P MCCB with thermal magnetic trip unit. 1 no. Digital multifunction meter (V+A+Hz) with a set of cast resin CTs 100/5A and communication port. 1 set of Phase indicating lamp with MCB 1 no. TPN surge protection device of Class 1 & 2. BUS BARS: 200A TPN bus bars of aluminium alloy. OUT GOING: 4 nos. 63A, 415V, 4P MCB of 10kA. Set 2.0 102539.83 0.0 |
| 254 | iv INCOMER : 1 no. 100A, 415V, Ics=35kA, 4P MCCB with thermal magnetic trip unit. 1 no. Digital multifunction meter (V+A+Hz) with a set of cast resin CTs 100/5A and communication port. 1 set of Phase indicating lamp with MCB 1 no. TPN surge protection device of Class 1 & 2. BUS BARS: 200A TPN bus bars of aluminium alloy. OUT GOING: 5 nos. 63A, 415V, 4P MCB of 10kA. Set 1.0 102539.83 0.0 |
| 255 | v INCOMER : 1 no. 63A, 415V, Ics=35kA, 4P MCCB with thermal magnetic trip unit. 1 no. Digital multifunction meter (V+A+Hz) with a set of cast resin CTs 100/5A and communication port. 1 set of Phase indicating lamp with MCB 1 no. TPN surge protection device of Class 1 & 2. BUS BARS: 150A TPN bus bars of aluminium alloy. OUT GOING: 4 nos. 32A, 415V, 4P MCB of 10kA. Set 3.0 91146.61 0.0 |
| 256 | vi INCOMER : 1 no. 63A, 415V, 4P MCB of 10KA. BUS BARS: 150A TPN bus bars of Cu. OUT GOING: 2 nos. 40A, 220V, DP MCB of 10kA. 7 nos. 25A, 220V, DP MCB of 10kA. Set 1.0 74056.78 0.0 SUB TOTAL (XIII) 0.0 XIV EARTHING AND MISCELLANEOUS ITEMS |
| 257 | NS-46 |
| 258 | NS-47 |
| 259 | NS-48 |
| 260 | NS-49 |
| 261 | NS-50 |
| 262 | NS-51 i. 50 mm x 6 mm GI strip Mtr 60.0 497.46 0.0 |
| 263 | NS-52 i. 50 mm x 6 mm Copper strip. Mtr 60.0 3096.61 0.0 |
| 264 | NS-53 |
| 265 | NS-54 SUB TOTAL-(XIV) 0.0 XV UPS 10KVA UPS |
| 266 | NS-55 i. THD(i) shall be less than 5% @ 100% load. ii. Input power factor shall be more than 0.98. from 50% to 100% load iii. Shall have Soft start Facility for Compatibility with Generators iv. Invertor capability to supply 150% load for 30 sec. v. Shall not allow deep discharge of the battery. There should be a external MCCB available with UV trip coils. The MCCB should disconnect itself in case of UV or emergency conditions. vi. Shall have inbuilt SNMP, Modbus Cards installed for monitoring on BMS. vii. UPS to have inbuilt Static By-pass enabled Set 1.0 160360.17 0.0 |
| 267 | NS-55(ii) SUB TOTAL-(XV) 0.0 XVI DG SET |
| 268 | NS-56 Diesel Engine:Diesel engine 4 stroke radiator cooled, electric start, of suitable BHP at 1500 RPM suitable for above output of alternator at 40 degree C, 50 % RH & at 1000 meter MSL and conforming to ISO-3046-1/1, ISO 15550 capable of taking 10 % over loading for one hour after 12 hours of continuous operation. The engine will be fitted complete with all the required accessories with Mechanical Digital Generator. Alternator : Synchronous alternator rated 100 KVA 415 volts at 1500 RPM, 3 phase 50 Hz, AC supply with 0.8 lagging power factor at 40 Degree C, 50 % RH & at 100 Meter MSL. The alternator shall be having SPDP enclosure, brushless, continuous duty, self-excited and self-regulated through AVR confirming to BS:5000/IEC 60034-1 suitable for tropical conditions and with class H insulation. DG CONTROL PANEL Metering Engine Parameters:- Engine Speed Lube Oil pressure Coolant temperature Engine Running Hour Engine Battery voltage Running status Fuel level in Percentage Event Log with date and time Electrical Parameter:- Generator Voltage (Ph-Ph) Generator Voltage (Ph-N) Generator Current (R,Y,B) Generator Apparent power (kVA) Generator active power(kW) Generator reactive power (kVAr) Generator Power Factor Generator Frequency (Hz) Cumulative Power Consumption in kWh Cumulative Power Consumption in kVAh Cumulative Power Consumption in kVArh Control Supply Voltage Protection Engine:- High Water Temperature Low oil pressure Low Fuel Level Over Speed Engine Fails to Start Electrical:- Generator under Voltage (ANSI-27) Generator over Voltage (ANSI-59) Generator under Frequency (ANSI-81L) Generator over Frequency (ANSI-81H) Generator over Current (ANSI-51) Control Supply under Voltage Control Supply over Voltage Phase Reversal Unbalanced Load Controller Modern genset controllers for AMF applications with an electronically controlled engine (CANbus) and AMFapplications with electronic governor. Controller Feature:- User-friendly interface and backlite full graphics LCD Battery voltage monitoring & reverse protection to aux supply 7/9 configurable analogue/digital inputs Auto, Manual and Remote Start/Stop Operation Island Operation Automatic Mains Failure Function CANbus Engine interface for communication Log with latest 100 events Fully configurable via PC using USB, RS485 communication DC Battery supply voltage range 8 to 28V Minus 20 to 65 ⁰C operating temperature range IP65 Protection class with gasket LCD alarm indication Power save mode 7 configurable Digital output Electrical Specification:- Supply Voltage Range: Nominal Voltage - 12/24 V DC Cranking drop out period: 50 ms Maximum reverse voltage protection: -32 V DC Measurement accuracy (battery voltage): ±1 % Full scale Resolution: 0.1 V Maximum current consumption ~200 mA Deep sleep current: 20 mA, 12/24 V DC Environmental Specification:- Operating Temp: -20 to 65⁰C in compliance with IEC60068 Vibration: 2G in X, Y and Z axes for 8 to 500Hz in compliance with IEC 60068-2-6 Shock: 15 g for 11 ms in compliance with IEC 60068-2-27 Humidity: 0 to 95% RH in compliance with IEC 60068-2-78 Protection Degree: IP65 Protection class with gasket in compliance with IEC60529 EMI/EMC in compliance with IEC 61000-6-2, 4 Base Frame & Foundation: Both the engine and alternator shall be mounted on suitable base frame of MS channel with necessary reinforcement which shall be installed on suitable cement concrete foundation and vibration isolation arrangement as per recommendations of manufacturer Starting System:24 V DC starting system comprising of starter motors: voltage regulator and arrangement for initial excitation complete with suitable nos. of batteries as required as per specification. Exhaust System:Dry exhaust mainfold with hospital exhaust silencer and suitable bellows between silencer and engine exhaust.. Starting System:24 V DC starting system comprising of starter motors: voltage regulator and arrangement for initial excitation complete with suitable nos. of batteries as required as per specification. Accoustic and weather proof enclosure with arrangement for fresh air intake for cooling of the engine & alternator, extraction, discharging hot air in to the atmosphere as per specifications with inbuilt fuel tank. 1 no. 250 Amps 4 pole MCCB including connection with copper cable / lead with alternator and suitable out going terminals for connection with 1 no.x 300 sq.mm Al Ar. XLPE cables of required sizes. The MCCB shall be mounted inside the canopy complete as required. Set 1.0 1309745.76 0.0 |
| 269 | NS-57 |
| 270 | NS-58 i 100 mm dia Class - B MS pipe. RM 5.0 3810.17 0.0 |
| 271 | NS-59 |
| 272 | NS-60 Copper control cable amoured type XLPE 1.1KV grade i 2Cx2.5sqmm RM 25.0 151.69 0.0 ii 4Cx2.5sqmm RM 25.0 253.39 0.0 iii 12Cx2.5sqmm RM 25.0 673.73 0.0 SUB TOTAL-(XVI) 0.0 XVII FIRE ALARM AND DETECTION SYSTEM |
| 273 | NS-61 i 4 Zone Panel Each 1.0 7513.56 0.0 |
| 274 | NS-62 |
| 275 | NS-63 |
| 276 | NS-64 |
| 277 | NS-65 SUB TOTAL- (XVII) 0.0 0.0 ANNEXURE-B COST SUMMARY FOR VC RESIDENCE SN DESCRIPTION AMOUNT WITHOUT GST REMARKS CIVIL WORKS ANNEXURE-1 |
| 278 | SUB HEAD I - EARTH WORKS |
| 279 | SUB HEAD II - CONCRETE WORK |
| 280 | SUB HEAD III - R.C.C WORKS |
| 281 | SUB HEAD IV - BRICK WORK |
| 282 | SUB HEAD V - STONE WORK |
| 283 | SUB HEAD VI - FLOORING |
| 284 | SUB HEAD VII - FINISHING |
| 285 | SUB HEAD VIII - WOOD WORK & PVC WORK/ALUMINIUM |
| 286 | SUB HEAD IX- STEEL WORK |
| 287 | SUB HEAD X- WATER PROOFING |
| 288 | SUB HEAD XI- NON SCHEDULE ITEMS Total Amount of Civil works 0.0 |
| 289 | PLUMBING WORKS |
| 290 | SANITARY FIXTURES & CP BRASS FITTINGS |
| 291 | SOIL, WASTE, VENT PIPE & RAIN WATER |
| 292 | WATER SUPPLY SYSTEM |
| 293 | SEWERAGE AND DRAINAGE |
| 294 | WATER SUPPLY DISTRIBUTION SYSTEM OVER TERRACE. Total Amount of Plumbing works 0.0 |
| 295 | ELECTRICAL WORKS |
| 296 | DISTRIBUTION BOARDS |
| 297 | POINT WIRING |
| 298 | SUPPLY OF LIGHT FIXTURE AND FANS |
| 299 | DATA AND TELEPHONE NETWORK |
| 300 | LT & HT CABLE |
| 301 | EARTHING AND MISCELLANEOUS ITEMS ELECTRICAL NON SCHEDULE ITEMS |
| 302 | DISTRIBUTION BOARDS |
| 303 | POINT WIRING |
| 304 | SUPPLY OF LIGHT FIXTURE AND FANS |
| 305 | DATA AND TELEPHONE NETWORK |
| 306 | MAIN LT PANEL AND MAIN DISTRIBUTION BOARD |
| 307 | EARTHING AND MISCELLANEOUS ITEMS Total Amount of Electrical works 0.0 Grand Total (Civil + Plumbing + Electrical ) 0.0 ANNEXURE-1 CIVIL WORKS FOR VC RESIDENCE S. No. HSR2021/NS DESCRIPTION OF ITEM UNIT QTY ESTIMATED RATE WITHOUT GST (INR) QUOTED RATE WITHOUT GST (INR) AMOUNT OF ITEMS (INR) I SUB HEAD I - EARTH WORKS |
| 308 | 4.12 All kinds of soil cum 752.64 77.68 0.0 |
| 309 | 6.13 SUB TOTAL-I 0.0 II SUB HEAD II - CONCRETE WORK |
| 310 | 6.1 All works up to plinth level: 6.1.6 1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size) cum 65.0 2441.96 0.0 SUB TOTAL-II 0.0 III SUB HEAD III - R.C.C WORKS CENTRING AND SHUTTERING (FORM WORK) |
| 311 | 6.3 i 6.30.1 Foundations, footings, bases of columns, etc. for mass concrete sqm 321.87 156.25 0.0 ii 6.30.2 Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc. sqm 22.46 282.14 0.0 iii 6.30.3 Suspended floors, roofs, landings, balconies and access platform sqm 719.43 208.04 0.0 iv 6.30.4 Shelves (Cast in situ) sqm 66.94 223.21 0.0 v 6.30.5 Lintels, beams, plinth beams, girders, bressumers and cantilevers sqm 916.31 296.43 0.0 vi 6.30.6 Columns, Pillars, Piers, Abutments, Posts and Struts sqm 602.78 261.61 0.0 |
| 312 | 6.33 6.33.6 Thermo-Mechanically Treated bars of grade Fe-500D or more. kg 16417.9 66.07 0.0 |
| 313 | 6.34 6.34.6 Thermo-Mechanically Treated bars of grade Fe-500D or more. kg 22011.48 67.86 0.0 |
| 314 | 6.25 (Note :- Cement content considered in this item is @ 330 kg/cum. Less cement used as per design mix is recoverable. Howeverno extra payment shall be made if excess cement is used as per design mix). i 6.25.1 All works upto plinth level Cum 252.21 4463.39 0.0 ii 6.25.2 All works above plinth level upto floor IV level Cum 207.53 4500.89 0.0 |
| 315 | 6.26 (Note :- Less cement used as per design mix is recoverable. However no extra payment shall be made if excess cement is usedas per design mix). i 6.26.1 Providing M-30 grade concrete instead of M-25 grade BMC/ RMC. (Note:- Cement content considered in M-30 is @ Cum 380.7 58.93 0.0 ii 6.26.2 Providing M-35 grade concrete instead of M-25 grade BMC/ RMC. (Note : Cement content considered in M-35 is @ Cum 79.02 118.75 0.0 SUB TOTAL-III 0.0 IV SUB HEAD IV - BRICK WORK |
| 316 | 7.21 7.21.1 Cement mortar 1:4 (1 cement: 4 coarse sand) cum 6.67 4127.68 0.0 |
| 317 | 7.47 i 7.47.2 Cement mortar 1:6 (1 cement : 6 coarse sand) cum 187.85 4070.54 0.0 |
| 318 | 7.31 7.31.2 Cement mortar 1:4 (1 cement :4 coarse sand) Sqm 471.2 474.11 0.0 |
| 319 | 7.3 SUB TOTAL-IV 0.0 V SUB HEAD V - STONE WORK |
| 320 | 8.26 Granite of any color and shade-Kitchen/Toilet Counters/sill/Coping 8.26.2.2 Area of slab over 0.50 sqm sqm 86.33 2775.89 0.0 |
| 321 | 8.28 SUB TOTAL-V 0.0 VI SUB HEAD VI - FLOORING |
| 322 | 10.1 10.10.1 40 mm thick with 20 mm nominal size stone aggregate Sqm 11.98 267.86 0.0 |
| 323 | 10.5 10.50.1 Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent. sqm 182.99 2706.25 0.0 |
| 324 | 10.51 |
| 325 | 10.58 |
| 326 | 10.63 10.63.2 Size of Tile 600x600 mm Sqm 389.84 986.61 0.0 |
| 327 | 10.67 10.67.2 Size of Tile 600x600 mm Sqm 24.66 1003.57 0.0 |
| 328 | 6.1.4 |
| 329 | 10.37 10.37.1 25mm thick sqm 218.56 790.18 0.0 |
| 330 | 10.38 |
| 331 | 10.96 |
| 332 | 10.1 SUB TOTAL-VI 0.0 VII SUB HEAD VII - FINISHING |
| 333 | 11.1 11.1.1 1:3 (1 cement : 3 fine sand) Sqm 493.44 96.43 0.0 |
| 334 | 11.8 11.8.2 1:6 (1 cement: 6 coarse sand) Sqm 680.2 105.36 0.0 |
| 335 | 11.9 11.9.2 1:6 (1 cement: 6 coarse sand) Sqm 453.47 127.68 0.0 |
| 336 | 11.18 |
| 337 | 11.74 11.74.2 Two coats Sqm 1627.64 38.39 0.0 |
| 338 | 11.82 11.82.1 Two or more coats on new work Sqm 52.0 49.11 0.0 |
| 339 | 11.91 |
| 340 | 11.61 11.61.1 New work (three or more coats) sqm 50.0 13.39 0.0 |
| 341 | 11.96 11.96.1 New work (Two or more coats applied @ 1.43 litre/10 sqm over and including priming coat of exterior primer applied @ 2.20kg/10 sqm) sqm 971.9 84.82 0.0 |
| 342 | 11.58 SUB TOTAL-VII 0.0 VIII SUB HEAD VIII - WOOD WORK & PVC WORK/ALUMINIUM WORK |
| 343 | 12.37 i 12.37.1 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws sqm 98.97 1400.0 0.0 ii 12.37.3 25 mm thick (for cupboard) including ISi marked nickel plated sqm sqm 67.28 1316.07 0.0 |
| 344 | 12.12 12.12.2 1.0 mm thick sqm 332.5 459.82 0.0 |
| 345 | 12.39 |
| 346 | 12.157 12.157.1 For fixed portion 12.157.1.2 Powder coated aluminium (minimum thickness of powder coating 50 micron) kg 2386.23 350.0 0.0 |
| 347 | 12.157.2 12.157.2.2 Powder coated aluminium (minimum thickness of powder coating 50 micron) kg 1212.09 402.68 0.0 |
| 348 | 12.159 i 12.159.1 With float glass panes of 4.0 mm thickness (weight not less than sqm10kg/sqm) Sqm 48.79 666.96 0.0 iii 12.159.4 With float glass panes of 8 mm thickness (weight not less than 20 kg/sqm) Sqm 61.56 1065.18 0.0 |
| 349 | 12.14 |
| 350 | 12.141 |
| 351 | 12.142 |
| 352 | 12.75 12.75.1 125 mm each 60.0 82.14 0.0 SUB TOTAL-VIII 0.0 IX SUB HEAD IX- STEEL WORK PRE-PAINTED / POWDER COATED GALVANISED SHEET DOOR/WINDOW FRAMES AND WINDOW SHUTTERS |
| 353 | 13.29 13.29.2 In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works kg 1775.33 83.04 0.0 |
| 354 | 13.5 i 13.5.2 10 x 80 mm-For Fixing Railings each 167.5 63.39 0.0 ii 13.5.3 10 x 120 mm each 258.0 77.68 0.0 |
| 355 | 13.41 |
| 356 | 9.47 9.47.1 GI Metal Ceiling Lay in plain Tegular edge Global white colourtiles of size 595x595 mm, and 0.5 mm thick with 8 mm drop;made of G I sheet having galvanizing of 100 gms/sqm (bothsides inclusive) and electro statically polyester powder coated ofthickness 60 microns (minimum), including factory painted afterbending. sqm 50.27 920.54 0.0 SUB TOTAL-IX 0.0 X SUB HEAD X - WATER PROOFING |
| 357 | 28.15 WATERPROOFING TREATMENT TO TERRACE AREA USING TWO COMPONENT 100% SOLIDS HYBRID POLYUREA COATING |
| 358 | 28.17 28.17.1 With average thickness of 120 mm and minimum thickness at sqmkhurra as 65 mm. sqm 630.0 664.29 0.0 |
| 359 | 28.2 28.20.1 For vertical surface two coats @ 0.70 kg per sqm Sqm 21.02 398.21 0.0 28.20.2 For horizontal surface one coat @1.10 kg per sqm Sqm 14.36 310.71 0.0 SUB TOTAL X 0.0 XI SUB HEAD XI- NON SCHEDULE ITEMS |
| 360 | NS-2 Size of Tile 600x600 mm (Toilet, Kitchen) sqm 88.44 875.42 0.0 |
| 361 | N.S-3 i Glass door shutter set 4.0 2878.81 0.0 ii Cub Boards shutter set 22.0 2075.42 0.0 |
| 362 | N.S-4 |
| 363 | N.S-5 |
| 364 | N.S-6 |
| 365 | N.S-8 i 300 x10 mm each 65.0 849.15 0.0 ii 200 x10 mm each 43.0 627.97 0.0 |
| 366 | NS-10 |
| 367 | NS-11 250x16 mm nos 11.0 880.51 0.0 |
| 368 | NS-12 ( HSR-10.73) SUB TOTAL XI 0.0 ANNEXURE-2 PLUMBING WORKS FOR VC RESIDENCE S. No. HSR2021/NS DESCRIPTION OF ITEM UNIT QTY ESTIMATED RATE WITHOUT GST (INR) QUOTED RATE WITHOUT GST (INR) AMOUNT OF ITEMS (INR) |
| 369 | 22.2 22.2.1 White vitreous chinaware Wash basin size 550x400 mm with a 15 mm CP Brass single hole basin mixer Each 3.0 3186.61 0.0 |
| 370 | 22.1 22.10.1 Kitchen sink with drain board 22.10.1.1 510x1040 mm bowl depth 250 mm Each 2.0 3718.75 0.0 |
| 371 | 22.10.2 22.10.2.1 610x510 mm bowl depth 200 mm Each 4.0 2619.64 0.0 |
| 372 | 22.14 22.14.2 Flexible pipe Each 6.0 56.25 0.0 22.14.2.1 32 mm dia |
| 373 | 22.15 |
| 374 | 22.24 22.24.1 W.C. pan with ISi marked white solid plastic seat and lid Each 11.0 4385.71 0.0 |
| 375 | 22.42 22.42.1 C.P. brass Each 11.0 389.29 0.0 |
| 376 | 22.105 22.105.1 15 mm nominal bore Each 11.0 511.61 0.0 |
| 377 | 22.108 22.108.1 15mm nominal bore Each 64.0 443.75 0.0 |
| 378 | 22.117 |
| 379 | 22.118 |
| 380 | 22.127 |
| 381 | 22.128 22.128.2 15 mm nominal bore with 45 cm length Each 53.0 76.79 0.0 |
| 382 | 22.212 22.212.1 C.P Brass 22.212.1.3 Three Way Per Set 19.0 134.82 0.0 |
| 383 | 22.216.1 22.216.1 25 Litres capacity each 5.0 8085.71 0.0 |
| 384 | NS-8 (i) 15 Ltr Capacity Each 6.0 5704.24 0.0 Total of Sub Head-1 0.0 |
| 385 | 22.222 22.222.2 Single Socket Type B i 22.222.2.2 110mm old SWR UPVC pipe lines laid complete Meter 156.0 322.32 0.0 ii 22.222.2.4 75mm old SWR UPVC pipe lines laid complete Meter 6.0 241.96 0.0 |
| 386 | NS-9 i 40 mm O.D. Meter 13.0 194.92 0.0 ii 50 mm O.D. Meter 18.0 355.08 0.0 iii 63 mm O.D. Meter 21.0 421.19 0.0 |
| 387 | NS-10 |
| 388 | NS-11 |
| 389 | NS-12 |
| 390 | NS-13 |
| 391 | 22.53 i 2.53.1 For 100 mm dia pipe Each 45.0 144.64 0.0 ii 2.53.2 For 75 mm dia pipe Each 2.0 141.07 0.0 Rain Water Pipes |
| 392 | NS-14 i PVC pipe 110mm-6 kg/cm2 Meter 28.0 616.1 0.0 ii PVC pipe 160mm-6 kg/cm2 Meter 52.8 1159.32 0.0 Total of Sub Head-2 0.0 |
| 393 | 22.86 i 22.86.1 15 mm nominal outer dia Pipes Meter 44.99 205.36 0.0 ii 22.86.2 20 mm nominal outer dia Pipes Meter 114.4 264.29 0.0 iii 22.86.3 25 mm nominal outer dia Pipes Meter 9.9 333.04 0.0 iv 22.86.4 32 mm nominal outer dia Pipes Meter 5.0 428.57 0.0 |
| 394 | 22.85 i 22.85.1 15 mm nominal outer dia Pipes Meter 5.0 130.36 0.0 ii 22.85.2 20 mm nominal outer dia Pipes Meter 135.0 181.25 0.0 iii 22.85.3 25 mm nominal outer dia Pipes Meter 119.0 234.82 0.0 iv 22.85.4 32 mm nominal outer dia Pipes Meter 130.0 310.71 0.0 v 22.85.5 40 mm nominal outer dia Pipes Meter 24.0 429.46 0.0 vi 22.85.6 50 mm nominal outer dia Pipes Meter 20.0 648.21 0.0 |
| 395 | 22.87 22.87.3 25 mm nominal outer dia Pipes Meter 22.0 200.89 0.0 |
| 396 | 22.88 22.88.4 32 mm dia nominal bore Meter 22.0 351.79 0.0 |
| 397 | 22.91 22.91.4 32 mm dia nominal bore Meter 6.0 295.54 0.0 |
| 398 | NS-15 i 20 mm nominal bore Each 24.0 638.14 0.0 ii 25 mm nominal bore Each 16.0 994.07 0.0 iii 32 mm nominal bore Each 2.0 1641.53 0.0 iv 40 mm nominal bore Each 1.0 2377.12 0.0 |
| 399 | NS-16 i 15mm dia nominal bore Meter 14.3 66.95 0.0 ii 20mm dia nominal bore Meter 28.6 72.88 0.0 iii 25mm dia nominal bore Meter 5.0 80.51 0.0 |
| 400 | NS-17 25 mm nominal bore Each 2.0 2526.27 0.0 |
| 401 | 25.3 25.3.9 50mm dia Each 2.0 1584.82 0.0 |
| 402 | 25.6 25.6.7 50 mm dia. Each 1.0 2917.86 0.0 |
| 403 | 22.181 Total of Sub Head-3 0.0 |
| 404 | 4.16 4.16.1 All kinds of soil i 4.16.1.2 Pipes, cables etc. exceeding 80 mm metredia. but not exceeding 300 mm dia Meter 40.0 64.29 0.0 ii 4.16.1.3 Pipes, cables etc. exceeding 300 mm metredia but not exceeding 600 mm Meter 5.0 131.25 0.0 |
| 405 | NS-18 i 150 mm diameter Meter 21.0 371.19 0.0 ii 200 mm diameter Meter 11.0 433.9 0.0 |
| 406 | 22.164 i 22.164.2 150 mm diameter S.W. pipe Meter 21.0 383.04 0.0 ii 22.164.3 200 mm diameter S.W. pipe Meter 11.0 447.32 0.0 |
| 407 | NS-19 i 160 x 110 mm size P type With sewer bricks Each 13.0 4046.61 0.0 |
| 408 | NS-20 i 200 mm dia RCC pipes Meter 8.0 745.76 0.0 ii 300 mm dia RCC pipes Meter 5.0 1079.66 0.0 |
| 409 | 22.206 22.206.1 With common burnt clay non-modular bricks of class designation 7.5 Each 5.0 3281.25 0.0 |
| 410 | 22.19 22.190.1 Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) : 22.190.1.2 With Sewer bricks conforming to IS : 4885 Each 8.0 6597.32 0.0 |
| 411 | 22.191 22.191.1 Size 90x80 cm 22.191.1.2 With Sewer bricks conforming to IS : 4885 Meter 4.0 4125.0 0.0 |
| 412 | 22.198 22.198.2 With 20 mm diameter round bar Each 34.0 207.14 0.0 Total of Sub Head-4 0.0 |
| 413 | NS-21 a) Fixed Speed hydropneumatic system mounted on a common baseplate 150 mm dia pressure gauge, G.M.Gauge, G.M. isolation cock and cement concrete foundation with plaster b) Supply, Installation, Testing. & Commissioning of single/ multi stage, horizontal / vertical in-line pumps with head and base in cast iron, pump shaft and impeller in stainless steel AISI 304, mechanical seal coupled to a TEFC electric motor suitable for 400/440 volts, 3 phase 50 cycles A.C. supply having IP 55 protection enclosure, 2900 RPM. Each pump should be operate to a curve required by the operating conditions, vibration eliminating pads etc. complete with base and frame, nuts and bolts. All electricals including the power box containing circuit breakers / fuses, Complete with G.I. / M.S. post Galvanised suction header (from water tank to pumps) and delivery Headers, making connections with isolaton valves on suction side and isolaton valves + NRV on delivery side etc., complete. Capacity 7.5 cum/hr (125 lpm) @ 30 m Head (Each pump) Cut in pressure : 2.0 Kg/sq cm. Cut out pressure : 3.0 Kg/sq cm. Shut-off Head for each pump shall be minimum 115% of rated head. Approx. 1.5 KW / 2.0 HP or As Required Quantity : 2 Nos. (One working + One stand By) Make: Grundfos /Wilo / KSB c) Composite FRP pressure tank ( with LDPE single piece jointless inner shell ) fitted with precharged interchangeable bladder made of EPU suitable for direct contact with drinking water with base and inlet / outlet nozzle etc., nozzle with air/gas charging valve at top, safety valve, pressure gauge etc., The vessel shall be designed for operating pressure 3.0 kg/sq cm, test pressure 4.5 kg/sq cm. Capacity: 60 Ltrs. or as per manufacturer's recommendations. Make: Pentair / Structural /KSB d) Power box equipped with fuses, isolators, circuit breakers, cable, wiring, earthing as required. Contractor shall include all items for smooth running of system. Incoming power to this panel shall be provided by others from main feeder. Quantity 1 No Fixed Speed Hydropneumatic System Set 1.0 251111.02 0.0 Total of Sub Head-5 0.0 ANNEXURE-3 ELECTRICAL WORKS FOR VC RESIDENCE S. No. HSR2021/NS DESCRIPTION OF ITEM UNIT QTY ESTIMATED RATE WITHOUT GST (INR) QUOTED RATE WITHOUT GST (INR) AMOUNT OF ITEMS (INR) |
| 414 | 23.22.4 i 23.22.4.3 SPN DB Double Door 12 way ( 2 incoming and 10 outgoing) Each 2.0 1705.36 0.0 ii 23.22.4.4 SPN DB Double Door 16 way ( 2 incoming and 14 outgoing) Each 3.0 2079.46 0.0 i 23.22.4.7 TPN DB Horizontal type Double Door 8 way ( 8 incoming3phase*8 outgoing) Each 5.0 3957.14 0.0 iv 23.22.4.8 TPN DB Horizontal type Double Door 12 way ( 8 incoming3phase*12 outgoing) Each 2.0 5754.46 0.0 |
| 415 | 23.22.5 i 23.22.5.1 6 amp. to 32 amp Single Pole Each 182.0 144.64 0.0 ii 23.22.5.3 6 amp. to 32 amp Double POLE Each 5.0 425.89 0.0 iii 23.22.5.8 40 amp to 63 amp. MCB's FOUR POLE Each 7.0 1291.07 0.0 |
| 416 | 23.22.6 i 23.22.6.1 DP RCCB 30ma sensitivity , 25 A Each 2.0 1477.68 0.0 ii 23.22.6.2 DP RCCB 30ma sensitivity , 40 A Each 3.0 1669.64 0.0 iii 23.22.6.3 DP RCCB 30ma sensitivity , 63 A Each 21.0 2075.0 0.0 SUB TOTAL- (1) 0.0 |
| 417 | 23.4.1 23.4.1.1 Group A Point 130.0 519.64 0.0 |
| 418 | 23.4.3 23.4.3.1 Group A Point 70.0 225.0 0.0 |
| 419 | 23.4.4 23.4.4.1 Group A Each 50.0 725.0 0.0 |
| 420 | 23.4.5 23.4.5.1 Group A Each 23.0 999.11 0.0 |
| 421 | 23.3.6 i. 23.3.6.9 3 run of Size 1.50 Sqmm(1/1.40mm) Mtr. 200.0 189.29 0.0 ii. 23.3.6.10 3 run of Size 2.50 Sqmm(1.1.80mm) Mtr. 600.0 271.43 0.0 iii 23.3.6.8 2 run of Size 4 Sqmm(1/2.24mm) Mtr. 750.0 258.93 0.0 iii 23.3.6.3 1 run of Size 4 Sqmm(1/2.24mm) Mtr. 750.0 143.75 0.0 iv 23.3.6.4 1 run of Size 6 Sqmm(1/2.80mm) Mtr. 600.0 172.32 0.0 v 23.3.6.5 1 run of Size 10 Sqmm(1/3.50 mm) Mtr. 200.0 345.54 0.0 |
| 422 | 23.7.6 i 23.7.6.1 PVC pipe of 20 mm dia. Mtr. 200.0 25.89 0.0 ii 23.7.6.2 PVC pipe of 25 mm dia. Mtr. 200.0 32.14 0.0 iii 23.7.6.3 PVC pipe of 32 mm dia. Mtr. 50.0 44.64 0.0 iv 23.7.6.4 PVC pipe of 40 mm dia. Mtr. 50.0 57.14 0.0 |
| 423 | 23.8.11 i 23.8.11.6 Bell Push Each 2.0 76.79 0.0 ii 23.8.11.7 Step type Fan Regulator 2 modules 300 watt Each 29.0 257.14 0.0 |
| 424 | 23.8.4 SUB TOTAL- (2) 0.0 |
| 425 | 23.21 |
| 426 | 23.11 SUB TOTAL - (3) 0.0 |
| 427 | 23.23.10 |
| 428 | 23.8.10 23.8.10.1 1 & 2 Modules including combined plate for Telephone and data Each 14.0 92.86 0.0 |
| 429 | 23.8.11 i 23.8.11.8 Telephone Socket outlet modular type Each 2.0 75.0 0.0 ii 23.8.11.9 TV Socket outlet modular type Each 10.0 75.0 0.0 iii 23.8.11.11 RJ 45 Computer DATA socket outlet for CAT 6 or CAT6e cable Modular type Each 2.0 303.57 0.0 |
| 430 | 23.23.8 23.23.8.1 2 pair telephone wire Metre 40.0 7.14 0.0 SUB TOTAL - (4) 0.0 |
| 431 | 24.14 24.14.32 25 Sq mm 4 Core (Arm.) Metre 150.0 225.89 0.0 |
| 432 | 24.2.7 24.2.7.3 25 sqmm to 50 sqmm Cable 2 to 4 Core Each 2.0 76.79 0.0 |
| 433 | 24.2.8 24.2.8.5 25sqmm Each 8.0 9.82 0.0 |
| 434 | 24.2.2 24.2.2.2 16 Sq mm to 35 sqmm 2 to 4 Core Metre 120.0 160.71 0.0 |
| 435 | 24.2.5 24.2.5.2 16 Sq mm to 35 sqmm 2 to 4 Core Metre 20.0 20.54 0.0 |
| 436 | 25.5.2 25.5.2.3 DWC/HDPE pipe 63/50 mm outer dialinner dia Mtr 10.0 124.11 0.0 SUB TOTAL-5 0.0 |
| 437 | 24.1.1 |
| 438 | 24.1.2 |
| 439 | 24.1.3 |
| 440 | 24.1.4 |
| 441 | 24.1.5 |
| 442 | 24.1.10 |
| 443 | 24.1.13 SUB TOTAL -(6) 0.0 ELECTRICAL NON SCHEDULE ITEMS |
| 444 | NS-1 SUB TOTAL-(7) 0.0 |
| 445 | NS-6 SUB TOTAL-(8) 0.0 |
| 446 | NS-9 i Supply of 18W Surface Mounted Round Led Downlighter delivering minimum system lumen of 1800 lm & the luminaire shall be with system efficacy ≥ 100 lm / W. Housing Pressure Die Cast Aluminium heat sink, IP40 , Optics: High Transmittivity Plastic Diffuser. The operating CCT shall be 5700K with CRI of ≥80. The luminaire shall be BIS Registered with electronic driver with input voltage range of 100 to 265V , THD ≤ 10% & PF ≥ 0.95, 50,000 Hrs LED Life with L70 Criteria. Cut out dia is 145mm and height 39mm with +/- 2mm tolerance. The LED Driver shall be easily avaiable in India for repair and service. The LED shall be SMD type.The luminaire shall be with following certifications: LM79 & LM80 issued by LED manufacturer along with Photo Biological Safety Standard. (Eq. to Havells Cat. Ref. INTEGRANXTRDDLRSURD18WLED857S) Each 160.0 1161.02 0.0 ii Supply of 4ft Linear Batten LED surface mounted luminaire delivering an initial system lumen of 4400 lumens & the luminaire shall be with system efficacy ≥ 110 lm / W. The luminaire Housing shall be made of extruded Aluminium & the diffuser shall be of polycarbonate. The operating CCT shall be 6500K with CRI of ≥80. The luminaire shall be BIS Registered with electronic driver with input voltage range of 160 to 270V , THD ≤ 10% & PF ≥ 0.95 , 50,000 Hrs LED Life with L70 Criteria, IP20. The LED Driver shall be easily avaiable in India for repair and service. Luminaire shall have minimum surge protection of 3KV.The luminaire shall be with following certifications: LM79 & LM80 issued by LED manufacture along with Photo Biological Safety Standard. (Eq. to Havells Cat Ref STOUTPLUS1200BS40WLED840SPCWH)) Each 2.0 2322.03 0.0 iii Supply of 2ft Linear LED luminaire delivering an initial system lumen of 1000 lumens & the luminaire shall be with system efficacy ≥ 100 lm / W. The luminaire Housing shall be made of extruded Polycarbonate & the diffuser shall be of polycarbonate. The operating CCT shall be 6500K with CRI of ≥80. The luminaire shall be BIS Registered with electronic driver with input voltage range of 150 to 270V , THD ≤ 20% & PF ≥ 0.9 , 50,000 Hrs LED Life with L70 Criteria, IP20. The LED Driver shall be easily avaiable in India for repair and service. Luminaire shall have minimum surge protection of 2.5 KV.The luminaire shall be with following certifications: LM79 & LM80 issued by LED manufacture along with Photo Biological Safety Standard. (Eq. to Havells Cat Ref LUMILINEPLUSNEOBS10WLED865SPCSSINDS) Each 11.0 338.98 0.0 iv Supply of 10W Wall mounted LED Bulkhead Light delivering minimum system lumen of 1000 lm & the luminaire shall be with system efficacy ≥ 100 lm / W. Housing & Rim is Pressure Die Cast Aluminium, powder coated white , IP65, IK08, Optics: Polycarbonate Opal Diffuser. The operating CCT shall be 5700K with CRI of ≥80. The luminaire shall be BIS Registered with electronic driver with input voltage range of 140 to 280V , THD ≤ 10% & PF ≥ 0.95, 50,000 Hrs LED Life with L70 Criteria. Shall have minimum surge protection of 2.5KV. The LED Driver shall be easily avaiable in India for repair and service. The LED shall be SMD type.The luminaire shall be with following certifications: LM79 & LM80 issued by LED manufacturer along with Photo Biological Safety Standard. (Eq. to Havells Cat. Ref. RUGBYGENXFTS10WLED865SSYMBOPC) Each 4.0 889.83 0.0 |
| 447 | NS-10 SUB TOTAL-(9) 0.0 |
| 448 | SECTION - I- STRUCTURED CABLING SYSTEM PASSIVE |
| 449 | NS-11 |
| 450 | NS-12 SUB TOTAL - (10) 0.0 |
| 451 | NS-13 MDB LIGHT + POWER (VC RESIDENCE) LOCATED IN GROUND FLOOR INCOMER : 1 no. 100A, 415V, Ics=35kA, 4P MCCB with thermal magnetic trip unit. 1 no. Digital multifunction meter (V+A+Hz) with a set of cast resin CTs 100/5A and communication port. 1 set of Phase indicating lamp with MCB 1 no. TPN surge protection device of Class 1 & 2. BUS BARS: 200A TPN bus bars of aluminium alloy. OUT GOING: 8 nos. 63A, 415V, 4P MCB of 10kA. 3 nos. 32A, 230V, DP MCB of 10kA. AMF LOGIC FOR 1 No. 25 KVA DG Set part of the MDB LIGHT + LIFT. Supply fixing testing and commissioning of Auto Main Failure including auto by-pass panel for the 25 KVA DG set as per specification and requirement. Auto/Manual/Test/Off selector switch Energy analyzer unit to indicate current voltage frequency power factor and KWH Fuse for instruments Battery charger complete with transformer/rectifier, D.C. voltmeter and ammeter, selector switch for trickle, off and boost and current adjustment. Mains supply failure monitor Supply failure timer Restoration timer Control unit with three impulse automatic engine start/stop and failure to start lockout. Impulse counter with locking and reset facility. ON/OFF/Control circuit switch with indicator Audio/Video annunciation for High water temperature Low lubricating oil pressures Engine over speed Engine fails to start The above panel shall be complete as per specification and Single line diagram. Set 1.0 205079.66 0.0 SUB TOTAL-(11) 0.0 |
| 452 | NS-14 |
| 453 | NS-15 0.0 SUB TOTAL-(12) 0.0 Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail