| 1 | Taking out and servicing of window/split type air conditioner cap- 1.5/2.0 Ton incluiding cleaning/removing all dust/mud, oil and other foreign particle with compressed air/water jet from grill, screen filter at indoor unit and condenser fin, evaporator fin at outdoor unit using detergent solution or chemical solution complete all as specified. |
| 2 | M&L for flushing, pressurising the system , leakage testing, vacuumization and charging with refirgerent R - 410/R- 22 gas (suitable as per requirement) after rectifying leakage in the system vaccumising and dehydration as per standard practice including testing in all respect for following capacity split type air conditioner complete all as specified. |
| 3 | (a) 1.5 Ton Capacity |
| 4 | (b) 2.0 Ton Capacity |
| 5 | S & F in replacement of following items for window/ Split AC of any capacity:- |
| 6 | (a) Compressor for AC Capacity- 1.5 Ton for window/split AC (as per site requirement) as per existing make/LG/Voltas/Carrier/Tecumesh |
| 7 | (b) Compressor for AC Capacity- 2.0Ton for window/split AC (as per site requirement) as per existing make/LG/Voltas/Carrier/Tecumesh |
| 8 | (c) Starting Capacitor 80-100 / 100-120 MFD, Make : TESLA/ Godrej or Equivalent make complete all as specified. |
| 9 | (d) Running Capacitor 36 MFD/ 45 MFD, Make : TESLA/ or Equivalent make complete all as specified. |
| 10 | (e) Screen filter of air conditioner of cap - 1.5 / 2.0 TR as per existing make complete all as specified. |
| 11 | (f) Starting relay suitable for window and split type AC. Make: SRIRAM or Equivalent make complete all as specified. |
| 12 | (g) Thermostatic switch suitable for window/split type AC 1.5/2.0 Ton capacity of existing make complete all as specified. |
| 13 | (h) Fan motor with fan blade unit suitable for 1.5/2.0 Ton capacity window air conditioner of existing make complete all as specified. |
| 14 | (j) Condenser's fan motor with blade suitable for 1.5/2.0 ton split type air conditioner complete all as specified. |
| 15 | (k) Electronic panel board / PCB with display of non inverted Air conditioner cap- 1.5TR/2TR complete all as specified. |
| 16 | (l) Electronic panel board / PCB with display of inverted Airconditioner cap- 1.5TR/2TR complete all as specified. |
| 17 | (m) Plastic water drain hose pipe, 15mm dia for spit type AC complete all as specified. |
| 18 | (n) Remote control operating device for Window/Split type AC of 1.5/2.0 Ton with 02 Nos of pencil battery of existing make complete all as specified. |
| 19 | (o) Pencil batteries for remote of split/window AC complete all as specified. |
| 20 | (p) Copper tubes of size 4/8, 1/2 inch with aerofoam NBR rubber insulation tube complete all as specified. |
| 21 | (q) Copper tubes of size 3/8,5/8, 1/4 inch with aerofoam NBR rubber insulation tube complete all as specified. |
| 22 | (r) Stand for outdoor unit of existing size complete all as specified. |
| 23 | Taking out old unsv and S & F indoor unit complete including fan motor of existing make and size for split AC 1.5 TR complete all as specified. |
| 24 | Taking out old unsv and S & F outdoor unit complete of existing make and size for split AC 1.5 TR complete all as specified. |
| 25 | M&L for shifting of AC of any type of AC capacity 1.5/2.0 Ton complete in & out door unit including taking out brackets, pipe line and fixing insulating pipelines including brazing of copper tubes, testing/commissioning complete incl shifting of service connection and voltage stabilizer to the new location complete all as specified. |
| 26 | Annual maintenance of water coolers of any make installed at Bharatpur military station (39 FAD,Kanjoli line, KLP & Sewar fort) to check water quality, opreventive and breakdown maintenance, leakage testing, lubrication, , power supply, repair and replacement of filter candles time to time and the water cooler under contract will be serviced for times during the contract time as per standard checklist ,compressor will be checked for its proper functioning All breakdown calls will be attended to during the contract period,The Blower motor will be checked,the driver set of the blower section wll be inspected but tension adjusted and belts changed,Any defects in the electrical item and control wiring will be attended during contract period.cost of spare parts/consumables required shall be replaced separately complete all as specified. |
| 27 | M&L for painting of water coolers of Cap - 150/150 Ltrs by cleaning old deteriorated exterior surface and necessary prepartion of surface by scrapping rust, grease, dirt etc before applying two coats of synthetic enamel paint of Make : Asian Paints Ltd ( Ist quality) or equivalent of approved colour by using spray painting technique to match with existing colour at existing location complete all as specified. |
| 28 | All as per Item No 8 above but of Water cooler capacity 80/40 Ltrs complete all as specified. |
| 29 | M & L for flushing, pressurising the system , leakage testing vacuumization and charging with refrigerant R-134a at appropriate pressure after rectifying leakage in the system vaccumising and dehydration including testing as per standard practice at site for water cooler of cap 150/150 ltrs of Make : Bluestar/Usha/Voltas complete all as specified. |
| 30 | All as per item No 10 above but of Water cooler capacity 80/40 Ltrs complete all as specified. |
| 31 | S & F in replacement of following items for water cooler of any capacity:- |
| 32 | (a) Compressor unit for water cooler 150/150 Ltrs of existing make or any other make complete all as specified. |
| 33 | (b) Compressor unit for water cooler 80/40Ltrs of existing make or any other make complete all as specified. |
| 34 | (c) Condenser fan motor with fan blade for water cooler of any Cap of existing make or any other make apporved by GE complete all as specified. |
| 35 | (d) Capacitor 25/35 MFD, ISI marked complete all as specified. |
| 36 | (e) Thermostat with knob as per existing size and make complete all as specified. |
| 37 | (f) Relay with overload protection assembly complete all as specified. |
| 38 | (g) Magnetic rubber gasket of top cover as per existing size and make complete all as specified. |
| 39 | (h) Drain water tray of stainless steel by brazing/soldering the joints, vent pipes, outlet etc as per existing size and make complete all as specified. |
| 40 | (j) Pencil type strainer alongwith capillary tube suitable as per existing size and make complete all as specified. |
| 41 | (k) Float valve PVC 15mm bore, heavy duty complete all as specified. |
| 42 | (l) Chromium plated brass push cock size 15 mm suitable complete all as specified. |
| 43 | (m) PVC flexible pipe size 40 mm dia with necessary clamping with jubli clips for drain water tray complete all as specified. |
| 44 | (n) PVC connection of size 15 mm dia 450mm long with PTMT nuts complete all as specified. |
| 45 | M&L for storage tank leakage repair through brazzing/welding/silicon gel fiiling of any capacity water cooler complete all as specified. |
| 46 | Taking out and servicing of electric driven single phase refrigerators and deep freezer of any cap incluiding cleaning/removing all dust/mud, oil and other foreign particle with compressed air/water jet using detergent solution or chemical solution ,leakage testing of refrigerant,freezer storage leakage testing complete all as specified. Note : - Refrigeration gas will be measured seperatly in respective items of CA. |
| 47 | M&L for flushing, pressurising the system , leakage testing, vacuumization and charging with refrigerant R -22/R-134a (suitable as per requirement) after rectifying leakage in the system vaccumising and dehydration as per standard practice including testing in all respect for Refrigerator/deep freezer of Cap - 165 to 195 Ltrs complete all as specified. |
| 48 | All as per item No. 15 above but of capacity 200-280 Ltrs complete all as specified. |
| 49 | All as per item No. 15 above but of capacity 300-400 Ltrs complete all as specified. |
| 50 | S & F in replacement of following items for refrigerator/deep frezer of any capacity: |
| 51 | (a) Compressor unit for Regrigerator of cap 165-195 Ltrs of existing make or any other make complete all as specified. |
| 52 | (b) Compressor unit for Regrigerator of cap 200-320 Ltrs complete all as specified. |
| 53 | (c) Compressor unit for Regrigerator/Deep freezer of cap 200-400Ltrs complete all as specified. |
| 54 | (d) Starting relay suitable for existing refrigerator complete all as specified. |
| 55 | (e) Thermostatic switch auto defrost type with knob suitable for existing refrigerator complete all as specified. |
| 56 | (f) Bulb inside the refrigerator suitable for existing refrigerator complete all as specified. |
| 57 | (g) Magnetic rubber door gasket suitable for existing refrigerator complete all as specified. |
| 58 | (h) Push type door switch suitable for existing refrigerator complete all as specified. |
| 59 | (j) Door lock with two keys suitable for existing refrigerator complete all as specified. |
| 60 | (k) Overload protector suitable for refrigerator . Make: INDFOSS/DANFOSS or equivalent make complete all as specified. |
| 61 | (l) Strainer pencil type alongwith capillary tube suitable for refrigerator as per existing capacity complete all as specified. |
| 62 | (m) Electronic PCB for 260-400 Ltr refrigerator /Deep freezer complete all as specified. |
| 63 | Taking out and servicing of desert cooler of any capacity i.e. checking of desert cooler fan motor, submersible pump, socket point, PVC connections,Fan blade, wooden chips etc including noting the complaints in compliant register complete all as specified. |
| 64 | M&L for cutting of burnt winding of fan motor of size upto 450mm sweep and rewinding with super enamelled copper winding wire and replacing gun metal bush shaft.complete all as specified. |
| 65 | M&L for painting of desert cooler inner and outer surface with spray gun using one coat of red oxide and two coat of anti corrosive synthetic enamal paint of approved by GE complete all as specified. |
| 66 | S & F of Fan Motor copper wound 16/18\\" sweep, 3 Speed single phase 230V AC supply complete with Blade complete all as specified.(Make: Khaitan/Crompton Greaves/Bajaj) |
| 67 | M & L for MS Bracket with mounting ring of cooler fan motor and mounting clamps/legs of existing size/model complete all as specified. |
| 68 | S & F of PVC submersible Pump complete single phase 230 Volt AC supply for desert cooler, 1 meter head or suitable to existing desert cooler complete all as specified.Make: Khaitan/Crompton Greaves/ Bajaj |
| 69 | S & F of PVC front grill of any size as per existing including nuts, bolts & washers complete all as specified. |
| 70 | M & L for Side panel/shutter made out of 20 SWG GI sheet as per existing design and approved including handles (2 Nos.) duly welded / riveted complete all as specified. |
| 71 | M & L for Bottom tank made out of 20 SWG GI sheet as per existing unserviceable tank complete all as specified. |
| 72 | M & L for Top of the Desert Cooler made of 20 gauge GI Sheet riveted /bolted to match with existing complete all as specified. |
| 73 | Supply and fix speed control step type regulator for desert cooler 1000W/1500W etc complete all as specified. |
| 74 | S & F of PVC water distribution cup with PVC elbow and pipe for any size of cooler complete all as specified. |
| 75 | S & F of Capacitor cap- 4/6 MFD, suitable for desert cooler as per existing size. Make: L&T/Epco/Khaitan complete all as specified. |
| 76 | S & F of Piano switch 5 amps one way complete all as specified. |
| 77 | S & F of 3 pin plug top 5 Amp complete all as specified. |
| 78 | M & L for twin core 1.5 Sqmm copper conductor wire for internal wiring complete all as specified. |
| 79 | S & F of Float valve PVC 15mm bore, heavy duty complete all as specified. |
| 80 | S & F of PVC connection 60 cm long and 15mm dia complete all as specified. |
| 81 | M & L for Wooden chips pad of suitale size for 03 side shutters of desert cooler min 600 gm in weight complete all as specified. |
| 82 | M & L for PVC insulated and sheathed flexible 1100 volts grade 3 core multistranded copper conductor of size 2.5 sqmm complete all as specified. |
| 83 | S & F of 3 pin plug top 15 Amp complete all as specified. |
| 84 | S & F of PVC stop cock ,cast copper alloy, screwed down, high pressure,with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed suitable for 15 mm bore pipes complete all as specified. |
| 85 | S & F of PVC stop cock , cast copper alloy, screwed down, high pressure,with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed suitable for 20 mm bore pipes complete all as specified. |
| 86 | Supply & Fixing plywood 6mm thick duly fixed in windows with screws for ventilation opening for desert cooler as per existing size complete all as specified. |
| 87 | M&L for fixing and grouting of MS Stand (adjustment type) suitable for desert cooler of cap 3000/4000CFM made out of angle iron section complete with two coats of synthetic enammled black paint over a coat of red oxide primer complete all as specified. |
| 88 | S&F in replacement GI pipe, 15 mm bore, medium grade, ISI marked with fittings laid in trenches or fixed to walls, ducts, floors etc incluiding necessary excavation and earth work complete for desert cooler/water cooler connections complete all as specified. |
| 89 | All as per Item 44 above but of 20 mm dia bore complete all as specified. |
| 90 | Material and labour for chemical earthing complete with copper earth plate electrode of size 600mm x 600mm x 3 mm thick buried directly in ground(earth pit not less than 2.25m deep below normal ground level) with top edge of the plate not less than 1.5m deep below normal ground connected to and including copper earth strip 25 x 3 mm by means of copper bolts nuts check nuts and washer, returning & filling the pit with excavated soil mixing with charcoal 250 KG , Crystal salt 200KG , magnesium sulphate of 100 KG and vegetable soil all around the plate up to 350mm above from top edge of plate and balance portion filing with excavated soil in layers not exceeding 25mm thick, 25mm bore galvanised iron medium grade watering pipe up to top of plate, 50mm bore galvanisd iron light grade pipe for earth strip protection, including all excavation earth work in any type of soil, PCC 1:3:6 type C1 for chamber of internal size 300mm x300 x 300mm with 120mm thick wall and 700 mm x 700mm x 150mm thick, bed concrete, RCC 1:2:4, type B1 for precast chamber cover 50mm thick, reinforced with welded steel wire fabric or XPM jali (weight not less than 4.00 Kg/sqm), funnel, with wire mesh, complete all as specified and directed. Note:- (i) Item includes the cost of upto 7.5 metre GI pipe for protection of earth strip. (ii) Item includes cost of upto 7.5 metre earth lead strip. |
| 91 | S&F of following items for single phase voltage stabilizer cap- 3 to 5 KVA:- |
| 92 | (a) Replacement of buck boost PCB for voltage connection |
| 93 | (b) Display Unit |
| 94 | (c) Auto Transformer |
| 95 | S&F of following items for single phase voltage stabilizer cap- 1 to 2 KVA:- |
| 96 | (a) Replacement of ball boost PCB for voltage connection |
| 97 | (b) Display Unit |
| 98 | (c) Auto Transformer |
| 99 | S&F modular enclosure of single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB of 25 Amps, 240 volts complete all as specified. |
| 100 | Supply only refrigerent (R-32/R134A) gas for top up etc. complete all as specified. |
| 101 | Supply only refrigerent R-410/R-22 gas for top up etc complete all as specified. |
| 102 | M&L for submain wiring in and including PVC casing caping with two run of PVC insulated, sheathed multistranded copper conductor of 6 sqmm (FRLS) and one run of PVC insulated, sheathed multistranded copper conductor 6 sqmm (green in color) for earth continuity conductor and connected to common earth dolly with thimble etc complete all as specified and directed.. ( Note: Two run of 6 sqmm plus one run 6 sqmm of earth wire will be measured as 1RM) including dismantling of existing unserviceable submain wiring complete all as specified.Note: colour coding is to be maintained .(Ph-Red, N-Black, Earth- Green) |
| 103 | M&L for submain wiring in and including PVC casing caping having with two run of PVC insulated, sheathed multistranded copper conductor of 10 sqmm (FRLS) and one run of PVC insulated, sheathed multistranded copper conductor 10 sqmm (green in color) for earth continuity conductor and connected to common earth dolly with thimble etc complete all as specified and directed.. ( Note: Two run of 10 sqmm plus one run 10 sqmm of earth wire will be measured as 1RM) including dismantling of existing unserviceable submain wiring complete all as specified.Note: colour coding is to be maintained .(Ph-Red, N-Black, Earth- Green) |
| 104 | M&L for taking out Unsv U/G cable PVC insulated armoured PVC sheathed Al. Conductor, LT cable of any size complete all as specified. |
| 105 | Supply, laying, testing & commissioning LT XLPE insulated armoured (heavy duty) electric cable with stranded aluminium conductor 1100 volts grade (ISI marked) & laid in trenches/pipes or fixed on pole of the following sizes:- |
| 106 | (a) 35 Sqmm x 3.5 core |
| 107 | (b) 25 Sqmm x 4 core |
| 108 | Excavation in trenches in soft/loose soil not exceeding 1.5m wide and not exceeding 1.5 metre in depth and getting out for laying of cable etc. complete all as specified. |
| 109 | Returning, filling in soft/loose soil including spreading, levelling, watering and well ramming, in layers not exc 25 cm complete all as specified. |
| 110 | Removing of surplus soil to a distance not exc. 50 metre and depositing where directed at a level not exc.1.5 metre above the starting point complete all as specified. |
| 111 | M&L for sand cushioning to under ground cable provided with layer of sand complete all as specified. Note : Punned thickness shall be measured |
| 112 | M&L for cable protection cover with sub Class`B` bricks old size laid dry, flat perpendicular across the cable in trenches complete all as specified. |
| 113 | Boring of holes under road, pavement, hard standing by trenchless technology using suitable tools and machinery for laying of pipe upto 150mm bore complete all as specified.Note :- GI pipe shall be measured and paid in concern Item |
| 114 | S & F or laying galvanised steel tubing light grade (ISI marked) for protection of under ground cable on poles/walls under road crossing of size 50mm bore complete all as specified. |
| 115 | Supply and fixing in repair of concealed/surface distribution board double door type factory made and tested made of sheet metal enclosure powder coated suitable for mounting the MCB 240 volt, 415V of the following DBs :-Makes - Legrand/L&T/Havells. |
| 116 | (a) 4 way MCCB VTPN DB with busbar 415 volts (double door) |
| 117 | (b) 12 way SPN DB with 200 amps rated busbar 240 volts (double door type). |
| 118 | (c) 8 way SPN DB with 200 amps rated busbar 240 volts (double door type). |
| 119 | (d) 4 Way SPN DB with 200Amp rated busbar 240V (Double door type) |
| 120 | S&F in repairs MCB's of following capacity :- |
| 121 | (a) MCCB 4P 63 Amps 415 volt, Category- C curve, 10kA rapturing capacity ( ISI marked IS-8828) complete all as specified. |
| 122 | (b) MCB SP 6-32 Amps, 240 volts,Category- C curve, 10kA rapturing capacity ( ISI marked IS-8828) complete all as specified. |
| 123 | (c) MCB SPN 6-32 Amps, 240 volt,Category- C curve, 10kA rapturing capacity ( ISI marked IS-8828) complete all as specified. |
| 124 | (d) MCB SPN 40 Amps, 240 volt,Category- C curve, 10kA rapturing capacity ( ISI marked IS-8828) complete all as specified. Please Enable Macros to View BoQ information |