Tender For Maintenance Of Electrical Installation In Nrb At Chandigarh. (Replacement Of The Existing Defunct Led Flood Light Fittings Of Existing High Mast Installed In The Cricket Stadium In Punjab Engineering College At Sec-12, Chandigarh), Chandigarh-Chandigarh
TDR : 55380692
Tender Notice
BOQ
Expired
Chandigarh
Chandigarh
Tender For maintenance Of electrical installation In Nrb At Chandigarh. (Replacement Of The Existing Defunct Led Flood Light Fittings Of Existing High Mast Installed In The Cricket Stadium In Punjab Engineering College At Sec-12, Chandigarh)
Name of Work:- MTC. OF EI IN NRB AT CHANDIGARH. (REPLACEMENT OF THE EXISTING DEFUNCT LED FLOOD LIGHT FITTINGS OF EXISTING HIGH MAST INSTALLED IN THE CRICKET STADIUM IN PUNJAB ENGINEERING COLLEGE AT SEC-12, CHANDIGARH)
Sl. No.
Item Description
1
DSR 8.16LED Flood Light, powder coated pressure die cast aluminium (System lumen efficacy ≥120 and <135 lm/Watt).Supplying, Installation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMI-EMC as per CISPR-15, lenses for beam angle 30 deg-120deg as per the application and the project requirement, suitable tilt able fitting, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumenmaintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 and <135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).
2
250 watt Please Enable Macros to View BoQ information