| 1 | Earth work in excavation of foundation trenches in HARD soil up to the required depth including dressing and leveling the bed and depositing the excavated materials away from the site with all leads and lifts, T&P labour required for the work etc. complete as directed by the Engineer-In Charge. |
| 2 | Supplying and filling in foundation and plinth with sand including well watering, ramming, including cost, conveyance and royalities of all materials and cost of all labour with T&P required for the work etc. complete as per direction of Engineer-In-Charge. |
| 3 | Cement concrete (1:4:8) in foundation and plinth using 4 cm. size hard granite crusher broken metal of approved quarry and approved quality including hoisting lowering laying concrete in layers not exceeding 0.15 M. in depth including compacting watering and curing etc, complete including cost ,conveyance, royalities & of all materials and cost of labour etc with T&P required for the work etc. complete as per specification & direction of Engineer-In-Charge. |
| 4 | RCC work M-20 having a minimum compressive strength 200kgs/cm2 in 15cm.cubes at 28 days after mixing and tests conducted in accordance with IS.456 and IS.516 using 12mm.to 20mm. size black hard crusher broken granite stone chips of approved quality and from approved quarry including hoisting lowering laying and compact concrete by using vibrator watering and curing for 28 days centering shuttering and finishing the exposed surface smooth providing grooves or beads where necessary including cost, conveyance ,royalities & testing of all materials and cost of all labour with T&P required for the work etc. complete in all respect as per specification & direction of E.I.C.(but excluding cost of M.S Rod or Tor Steel & binding wires) |
| 5 | Foundation Raft |
| 6 | Plinth beam |
| 7 | Coloum & Roof beam |
| 8 | Roof slab |
| 9 | Lintel |
| 10 | Chajja |
| 11 | Fly Ash Brick masonary in C.M.(1:6) using Fly Ash .Bricks of size 25cm.x12xm.x 8 m. having crushing strength not less than 75 kgs./cm2 after immrersing the bricks for six hours in water before use in Superstructure including splays cutting, circular moulding corbelling, champhering and similar such type of works with watering and curing etc .including cost, conveyance, royalities and & testing of all materials and cost of all labour with T&P required for the work etc. complete as per specification & direction of Engineer-In-Charge. |
| 12 | Fly Ash Brick masonary in C.M.(1:6) using Fly Ash Bricks of size 25cm.x12xm.x 8 m. having crushing strength not less than 75 kgs./cm2 after immrersing the bricks for six hours in water before use in Foundation & Plinth including splays cutting, circular moulding corbelling, champhering and similar such type of works with watering and curing etc .including cost, conveyance, royalities and taxes & testing of all materials & of all labour with T&P required for the work etc. complete as per specification & direction of Engineer-In-Charge. |
| 13 | 12mm.thick cement plaster in C.M. (1:6) in finished smooth to surface of walls after racking out the joints including watering and curing with cost ,conveyance, royalities of all materials and cost of labour with T&P required for the work etc. complete as per direction of Engineer-In-Charge. |
| 14 | 16mm.thick cement plaster(1:6) finished smooth surface of walls after racking out the joints including watering and curing with cost ,conveyance, royalities of all materials and cost of labour with T&P required for the work etc. complete as per direction of Engineer-In-Charge. |
| 15 | Painting One coat with wall cement Primer (Water Base)by means of brush to outside surface of walls complete in all floors with cost, carriage and all taxes of all materials and cost of all labour with T&P required for the work etc. complete in all respect as per direction of the Engineer – in – Charge. |
| 16 | Distempering 2 coats with any approved shade over the interior surface of walls using distemper including cost, conveyance of all materials including cost of distemper with all taxes and cost of all labour with T & P required for the work etc. complete as directed by the Engineer – in – Charge. |
| 17 | Cutting straightening HYSD Bars/High tensile tor steels, confirming to FE -500 grade bending binding welding and jointing if necessary and tying the grills and placing in position as required for RCC work and for providing fan hooks hoisting lowering and laying including cost, conveyance of HYSD bars/High tensile tor steels and binding wires of 18 to 20 gauge and labour required for the work for bending binding and tying the grills in all floors etc. complete as per direction of E.I.C(Measurement will be taken excluding cost of binding wire)and payment will be made on the weight of M.S or tor steel only). |
| 18 | Supplying fixing and fittings MS Door,MS Window shutter with grill,of approved design and drawing made out of MS flat and MS angle at work site with one coat of anticorrosive red oxide zink chrome primer including cutting holes in brick or RCC walls and fixing with CC (1:3:6) including cost, conveyance and royalty of all materials all labour T&P required for the work complete (payment will be made on weight basis only)(In all floors) |
| 19 | MS Door |
| 20 | MS Window grill |
| 21 | Painting Two coats with Enamel paint on Old/new wood work after cleaning the surface, sand papering etc. including cost and conveyance of all materials, cost of paint with all taxes and cost of all labour with T & P required for the work etc. complete in all respect as directed by Engineer – in – Charge. |
| 22 | Painting 2 coats with water proofing weather coat over a coat of primer of approved shade by means of brush to outside surface of walls complete in all floors with cost, carriage and all taxes of all materials and cost of all labour with T&P required for the work etc. complete in all respect as per direction of the Engineer – in – Charge. |
| 23 | Supplying all materials, labour, T&P and providing and fixing to wall or ceiling and floor GI/PVC pipes, class-IV (10 k.g. F/cm) on firming I.S.4985 of the following nominal bore, tube fittings and clamps including making good the wall, ceiling and floor, testing all complete as per specification and direction of the Engineer in charge. |
| 24 | 25mm dia PVC ASTM pipe (sch-80) Ground floor |
| 25 | 32mm dia PVC ASTM pipe (sch-80) roof top |
| 26 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes conforming to IS:15778, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge |
| 27 | 20mm dia C-PVC Pipes |
| 28 | Ground floor |
| 29 | Supplying all materials, labour T&P and fitting and fixing brass/CP fittings of the following nominal bore with supply of all joiniting materials including cost & conveyance of all materials to worksite, payment of taxes etc. all complete as per P.H specification and direction of the Engineer-in-charge. |
| 30 | 15mm dia CP angle stop cock (Jaquar/Johnson/Hindware make) |
| 31 | 15mm dia CP two in one bib cock (Jaquar/Johnson/Hindware make) |
| 32 | 25mm dia brass full way valve (Shakti make) |
| 33 | Heallth Faucet |
| 34 | 15mm CP Extension piece |
| 35 | 125mm CP grating |
| 36 | 15mm size C.P. flange |
| 37 | supplying all materials, labour, T&P and cutting holes through existing brick work including making good the damages in cement mortar (1:4) for taking G.I. Pipes and fittings/ P.V.C. pipes and fittings including watering, curing, cost & conveyance of all materials to worksite, payment of royality, taxes etc. all complete as per direction of Engineer-in-charge. |
| 38 | Ground floor |
| 39 | Supplying all materials, labour, T&P and cutting grooves in pucca floors and walls for taking G.I./P.V.C. pipes and making good the damages including watering , curing , cost & conveyance of all materials to worksite, payment of royality, taxes etc all complete as per direction of the Engineer-in-charge. |
| 40 | Ground floor |
| 41 | Supplying all materials, labour, T&P and fitting and fixing U-PVC SWR soil waste ventilating pipes and fittings of the following outside diameter conforming to ISI No 13592/1992 to walls with nails, bobbins and wooden plugs or laying in trenches including jointing with supply of approved rubber lubricant by non-heat application method/as per manufacturer's specification, testing, earthwork in excavation in all kinds of soil and refilling of trenches , cost & conveyance of all materials to worksite, payment of taxes etc. all complete as per P.H specification and direction of the Engineer-in-charge. |
| 42 | 110mm U-PVC SWR Pipe (Ori Plast/Finolex/Supreme Make ) |
| 43 | 110mm U-PVC ‘P’ Trap(Ori Plast/Finolex/Supreme Make) |
| 44 | 110mm U-PVC door bend(Ori Plast/Finolex/Supreme Make) |
| 45 | 110mm U-PVC Plain tee(Ori Plast/Finolex/Supreme Make) |
| 46 | 110mm U-PVC offset without ear(Ori Plast/Finolex/Supreme Make) |
| 47 | 110mm U-PVC Cowl(Ori Plast/Finolex/Supreme Make) |
| 48 | 110mm U-PVC Socket(Ori Plast/Finolex/Supreme Make) |
| 49 | Supplying all materials, labour, T&P and fixing the following vitreous china Wash Down Water Closet (European type W.C pan) with integral ‘P’or ‘S’ trap to the floor with wooden plug and chromium plated pedestal screws including jointing the trap with soil pipe in cement mortar (1:1), fixing plastic seat and cover for wash down water closet with chromium plated brass hinges and rubber buffers including polishing etc all complete as per specification and direction of the Engineer in charge.SINGLE PIECE-WATER COLSET P TRAP - LYS-WHT-0204P |
| 50 | Grab bar (Jaquar/Johnson/Hindware make) |
| 51 | 450MM long Grab bar (Jaquar/Johnson/Hindware make) |
| 52 | Supplying all materials, labour T&P and fixing wash basins with hole for pillar taps with cast iron or M.S.brackets painted white including cutting holes in walls and making good the damages with supply of wooden plugs, screws and cement etc, fixing pedestal for wash basin recessed at the back for the reception of pipes and fittings, fixing PVC waste pipe of 32mm nominal diameter for wash basin including brass check nut complete, fixing pillar taps capstan head screw down high pressure lettered 'Hot' and 'Cold' with long screws, shanks and back nuts of 15mm dia nominal bore, fixing 15mm dia PVC inlet connection pipe and making connection with pillar cocks and supply mains for wash basin, fixing 32mm dia CP brass waste, cost & conveyance of all materials to worksite, payment of taxes etc. all complete as perP.H specification and direction of the Engineer-in-charge |
| 53 | 550mmx400mm W.H.basin (Hindware/Parryware/Neycer make)with 15mm dia C.P.pillar cock (Plaza make) |
| 54 | Supplying all materials, labour, T&P and fixing CP soap holder complete with CP brass brackets fixed to wooden plugs with CP screws as per specification and direction of the Engineer in charge |
| 55 | CP soap holder |
| 56 | Supplying all materials , labour, T&P and cutting holes through existing brick or laterite masonry wall for taking U-PVC pipes and fittings including making good the damages etc. all complete as per P.H. specification and direction of Engineer-in-charge |
| 57 | Recessed wirring to light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor of ISI marked Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI/V-Guard with 20 mm dia HMS FRLS PVC conduit ISI marked Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal 6A modular type (flame retradant type) switch ISI marked Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) and ceiling rose ISI marked of modular type G.I box with metallic cover plate (both side) (flame retradant type) Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) of suitable size, modular box with 1.5 sq. Mm FRLS PVC insulated single core multistandard copper conductor as earth wire including all accessories and connection as per direction of Engineer -in -Charge. . All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials. |
| 58 | GROUP-A |
| 59 | GROUP-B |
| 60 | GROUP-C |
| 61 | Supplying ,fixing of 6A Plug on the same board in existing switch board with complete fitting by 01 no of 6A switch & socket (modular type)( (flame retradant type)) & other required accessories of ISI marked as approved as per direction of Engg. -in -Charge. Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) . |
| 62 | Recessed wiring to submain of the following FR PVC insulated single core multistrand copper conductor of ISI Marked confirming to IS-694/1990 in 20mm dia nonmetalic heavy duty flexible conduct 1.6 sqmm thick along with following sqmm FR PVC insulated single core multistrand copper conductor as earth wire as required complete in all respect as per direction of Engineer in charge (Havells/Finolex/Anhor.) |
| 63 | 2x1.5 sqmm +1x1.5 sqmm 1100 Volts confirming to IS 694/1990 |
| 64 | 2x2.5 sqmm +1x1.5 sqmm 1100 Volts confirming to IS 694/1990 |
| 65 | 2x4 sq mm+1x1.5 sqmm 1100 Volts confirming to IS 694/1990 |
| 66 | S/F of Bakelite Angle holder ISI mark |
| 67 | S/Fof 9W LED Bulb (Havells/Philips/Crompton) |
| 68 | S/F. of 15Wt. LED Surface mounting down lights of ( MAKE- Havels/phillips/Crompton ) |
| 69 | S/F of 12 inch Heavy duty (Metalic Colour) Exahust Fan with wall cutting, plastring, paintingwith all connection complete in all respect as per direction of Engineer- in- charge. (Usha maxx aor dew white /CG TRANS Air /Havels-venti air DS/Orient -air flow)) |
| 70 | Supply ,installation, testing and commissioning of main switches (IS 13940 part-3/1993) of following capacity on existing surface / wall mounting and completer with HRC fuse links, interconnections, earthing , etc as required as per direction of Engineer-in-charge. (Make-Seimens/ HPL/ Anchor/ L&T/Havells/C&S/RK) |
| 71 | 63Amp ICDP main switches with MS board(Rs 2566/- + 1.24.16) |
| 72 | supply and fixing of single pole mcb with sheet steel enclosure ,distribution board ,on surface /recess,complete with tinned copper bus bar ,neutral bus bar ,earth bar ,din bar ,dertachable gland plate ,interconnection .phosphate and powder painted including including earthing ect. as required ( but with out MCB/RCCB/ISLOATOR ) (MAKE-Legrand/Seimens/schneider/L & T) |
| 73 | 4way SPN DD DB BOX. |
| 74 | supply and fixing of 5 to 32 amp rating 240 volt c series miniature circuit breaker suitable for lighting and other loads of the following poles in the existing MCB DB ISI marked complete with comnnections testing and commisioning as required (MAKE-Legrand DPX3/Siemens betaguard /schneider acti 9 ) |
| 75 | 6 to 32 SP MCB |
| 76 | S/L of 2x4sq.mm Service wire with G.I. wire |
| 77 | S/F of StandardEarthing with medium class 40mm 3Mtr. Long ISI marked GI Earth pipe including accessories such as funnel GI nut, Bolt, washer , hinged cover plate with looking arrangement, 40mm to 20GI rediusor 5nos 20mm dia holes on GI pipe required charpol salt, Excavation of earth brick work in cement mortar complete in all respect as per specification of SR 2011 and as per Direction of Engineer-in -Chage. |
| 78 | proving and fixing of 8 SWG(4mm) dia copper wire on surface or in recess for loop earthing along with existing surface /reccessed conduit /submain wiring /cable as required Please Enable Macros to View BoQ information |