| 1 | Demolishing R.C.C. work including stacking of steel bars & disposal of unserviceable within 50 mts. lead. |
| 2 | Earthwork in excavation of foundation of structures of culverts, abutments piers, retaining walls etc. as per drawing and technical specification, in all types of strata comprising any of the material such as soil, silt sand, clay, gravel, murrum of all varieties shingles, pebbles all types of conglomerates, laterite rock etc soft rock, ordinary rock or disintegrated rock fissured shattered/ decomposed rock or weathered rock all such material as described under appendix to those specification either in full or in parts as the case may be adopting mechanical means (hydraulic excavator) or any approved method or methods as the case may be convenient or permitted inclusive of chiseling and wedging etc in all conditions such as dry, moist, saturated, submerged, foul condition etc including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing sides, ramming of bottoms, getting out the excavated soil/rock to be leveled and neatly dressed, |
| 3 | pumping and bailing out of water, back filling the excavated earth to the extent required and utilizing the remaining earth locally for road work, barricading, danger lightening, guarding and disposal of excavated earth as directed by the engineer in charge all complete including all leads and lifts and up to depth of excavation as per MoRT & H Specification 304. |
| 4 | TRANSPORTATION AND CARRIAGE OF MATERIALS |
| 5 | (A) By Tipper truck including loading, unloading and stacking |
| 6 | ii) Earth by tipper truck upto 5.00 km |
| 7 | Rubble packing with hard laterite stone under floors including watering, ramming & consolidating etc. in pipeline trenches and other foundation complete. |
| 8 | Centering & shuttering including Strutting, Propping & removal of formwork for : |
| 9 | i) Foundations, Footings, Bases for columns and mass concrete |
| 10 | Centering & shuttering including Strutting, Propping & removal of formwork for : |
| 11 | ii)vertical surfaces such as retaining walls , return walls, walls (any thk) including attached pilasters, buttresses, plinth and string courses, fillets, etc. |
| 12 | Centering & shuttering including Strutting, Propping & removal of formwork for : |
| 13 | xiii)Suspended floors, roofs landings, shelves & their supports |
| 14 | Providing and fixing weepholes with rigid PVC make laid in position with a required slope and level while layingpipes of approved the concrete of retaining wall,wing wall and earth retainig structure complete as directed by the Engineer in charge. |
| 15 | b) 75 mm dia |
| 16 | Providing & laying cement concrete 1:2:4 (1 cement: 2 coarse sand: 4 graded granitic or basaltic stone aggrt. 20 mm. nominal size) excluding cost of centering, shuttering and finishing in: |
| 17 | a)All works upto plinth level |
| 18 | Providing & laying cement concrete 1:2:4 (1 cement: 2 coarse sand: 4 graded granitic or basaltic stone aggrt. 40 mm. nominal size) excluding cost of centering, shuttering and finishing in: |
| 19 | b) In retaining walls , return walls(any thk) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping bed blocks, anchor blocks, plain window sills, fillets etc, upto floor five level. |
| 20 | Providing and laying in position machine batched concrete (BMC), machine mixed and machine vibrated design mix cement concrete of specified grade for reinforced cement concrete work including pumping of concrete to the site of laying but excluding the cost of centering , shuttering, finishing and reinforcement including admixtures in recommended proportions as per IS 9103 to accelerate, retard setting of concrete, improve workability without impairing the strength and durability as per the direction of the Engineer-in-charge. M25 grade of reinforced cement conrete by using 410kg of cement per cu.m. of concrete. All works upto floor V level. |
| 21 | Add for providing richer or leaner mixes respectively at all floor levels |
| 22 | i )Providing M-30 grade concrete by using 420kgs of cement per cu.m. of concrete instead of M-25 grade of B.M.C. |
| 23 | Providing TMT steel reinforcement bars of (SAIL, TATA. VIZAG, JSW Steel Ltd.) (Confirming to IS 1786 of 1986) for RCC work (conforming to I.S. 1786 of 1986) including bending, binding & placing in position in all the floors along with the factory made precast concrete cover blocks of specified sizes whose compressive strength is not less than that of surrounding concrete in the structural member. |
| 24 | Providing and laying filter media with Granular materials crushed stone Aggregates satisfying the rerquirement As Per Clause 2504.2.2 of MOSRT & H Specification to a thickness of 500 mm laid horizontally in layers of 250mm thick and compacted to firm condition etc. complete as direction by Engineer-in-charge. |
| 25 | Laterite boulder masonry in cement concrete1:3:6( 1cement, 3 coarse sand:6 graded stone aggregate of 40mm nominal size) in foundation |
| 26 | Extra for laterite boulder masonry in superstructure |
| 27 | 12mm cement plaster 1:3 (1 cement : 3 fine sand) |
| 28 | Supplying of laterite stone soling of size 150-200 mm size and murrum having P.I. Value not more than 6 and laying including packing with smaller stones and consolidation with power road roller including spreading, watering and consolidation of binding material etc.(Measurements shall be considered on finished item) . |
| 29 | Providing and laying 50mm(consolidated thickness)full grout using granitic or basaltic stone of specified grading at 6.00 cu.m. per 100 sq.m. grouting with hot bitumen straight run bitumen(or with such bituminous material of grade and type as specified by the Engineer-in-Charge)at 5.0kg. per sq. m. binding with key aggregate of granitic or basaltic stone of specified grading at 1.5 cu.m. per 100 sq.m. including Providing and laying seal coat sealing the voids in a bituminious surface laid with F.E loader with 1 Cu.m. bucket capacity to the specified levels, grade and cross fall using Type A seal coat with 0.98 kg/sqm of bitumen of grade as per MoRT&H specifications clause 513. |
| 30 | Supplying and fixing of Precast RCC slabs(factory made,the factory should be ISO certified and registered under Dirctorate of Industries, Govt. of India) at site in concrete Grade of M-25 with 20 mm nominal size Granitic or basaltic aggregate, consolidated by means of mechanical platform, vibration etc. with lifting hooks of M.s. 10mm bars and PVC cups including cost of reincforcement, Certificate from manufacturer shall be produced indicating grade of concret and minimum content of steel in the product along with 5 year free replacement warranty in case of breakage complete and as directed by Engineer -in -charge. |
| 31 | a)Size 900 x 400 x 150 mm with steel reinforcement not less than 7 kg per unit -30 T capacity. (The slabs shall be procured through GHRSSIDC enlisted vendors and payment shall be released on submission of invoice) |
| 32 | Providing and laying of hot applied thermoplastic compound 2.5 mm thick including reflectorising glass beads @ 250 gms per sqm area, thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC : 35. The finished surface to be level uniform and free from streaks and holes as per MORTH Specification 803 |
| 33 | Precast plain cement chequered tiles 22 mm thick of required shades laid in floors, treads of steps and landing on 20 mm thick bed of Cement mortar 1:4 (1cement : 4 coarse sand) jointed with neat cement slurry mixed with pigment to match the shade of tiles including rubbing and cleaning etc. complete. |
| 34 | c) Dark shades using ordinary cement |
| 35 | Steel work welded in built up section and framed work including cutting, hoisting, fixing in position for steel grating of size 2.00 m x 0.90 m with R.S. joists, Tees, angles, flats and channels of TATA/ SAIL/ VIZAG make only with structural steel not less than 163.6 kg. per unit including applying priming coat of red lead paint and two or more coats with superior quality ready mixed paint for steel work of approved brand and Manufacture in all shades on new work to give an even shade as per the approved drawing and direction of the Engineerin-charge. |
| 36 | Supplying and fixing Pre-cast cement concrete kerb-stones(factory made,the factory should be ISO certified and registered under Dirctorate of Industries, Govt. of India) of M-20 with 20 mm nominal size granitic/basaltic aggregate properly consolidated by mechanical plat-form and vibrators with smooth finish including fixing at site complete as per specification. |
| 37 | Supply and Fixing of Convex Mirror Size 32'' Dia Unbreakable type Mounted on MS Pole of 6 ft height, 2.5 inches dia 3 mm thick for Mirror |
| 38 | Retro- reflectorised Traffic signs (Providing and fixing of retro- reflectorised cautionary, mandatory and informatory sign as per IRC :67 2012 made of high intensity Grade sheeting using ASTM sheeting \\"C' type XI micro prismatic retro reflective material vide clause 801.3, fixed over aluminium sheeting, 2 mm thick with area not exceeding 0.9 sqm supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 45 cm x 45 cm x 60 cm, 60 cm below ground level as per approved drawing)etc complete as per MORT &H Specifications Fifth Edition. A 10 years warranty for Retro Reflective Sheeting from the original sheeting manufacturer & a certified copy of three years outdoor exposure report from an independent test lab for the product offered shall be submitted by the contractor. |
| 39 | 60 cm equilateral triangle (The sign board shall be procured through GHRSSIDC enlisted vendors and payment shall be released on submission of invoice) |
| 40 | Retro- reflectorised Traffic signs (Providing and fixing of retro- reflectorised cautionary, mandatory and informatory sign as per IRC :67 2012 made of high intensity Grade sheeting using ASTM sheeting \\"C' type XI micro prismatic retro reflective material vide clause 801.3, fixed over aluminium sheeting, 2 mm thick with area not exceeding 0.9 sqm supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 45 cm x 45 cm x 60 cm, 60 cm below ground level as per approved drawing)etc complete as per MORT &H Specifications Fifth Edition. A 10 years warranty for Retro Reflective Sheeting from the original sheeting manufacturer & a certified copy of three years outdoor exposure report from an independent test lab for the product offered shall be submitted by the contractor. |
| 41 | 60 cm circular (The sign board shall be procured through GHRSSIDC enlisted vendors and payment shall be released on submission of invoice) Please Enable Macros to View BoQ information |