| 1 | Tender for balance internal & external brick work & plastering work, RCC works for various pending works , Structural steel along with sheeting work of Auditorium hall portion & Convention hall portion, entire balance flooring work, Internal putty work , Aluminium window fixing works & plumbing & water supply pipe line works etc. for Auditorium & Convention hall Building at RourkelaOne Project at ABD Area in Rourkela. Tender for balance internal & external brick work & plastering work, RCC works for various pending works , Structural steel along with sheeting work of Auditorium hall portion & Convention hall portion, entire balance flooring work, Internal putty work , Aluminium window fixing works & plumbing & water supply pipe line works etc. for Auditorium & Convention hall Building at RourkelaOne Project at ABD Area in Rourkela. NIT No: EPI/PCO/BBSR/806/249 dated 06.05.2026 SUMMARY Sl. No. Description of Works Amount in Rs. A Civil Work (SAA Building) 26684886.4 B PH work 3369271.0 Total 30054157.0 Say 30054157.0 Rupees: Three Crore Fifty Four Thousand One Hundred & Fifty Seven Only Tender for balance internal & external brick work & plastering work, RCC works for various pending works , Structural steel along with sheeting work of Auditorium hall portion & Convention hall portion, entire balance flooring work, Internal putty work , Aluminium window fixing works & plumbing & water supply pipe line works etc. for Auditorium & Convention hall Building at RourkelaOne Project at ABD Area in Rourkela. NIT No: EPI/PCO/BBSR/806/249 dated 06.05.2026 Sl.No. Description of Items Unit Quantity Rate (in Rs) Amount A CIVIL WORK |
| 2 | Half brick masonry with non modular fly ash bricks of class designation 7.5, conforming to IS :12894, in super structure above plinth and upto floor V level. Cement mortar 1 : 3 (1 cement : 3 coarse sand) |
| 3 | Brick work with clay flyash F.P.S. (non modular) brick of class designation 7.5 in superstructure above plinth level up to floor five level in :Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 4 | Cement Plaster in course sand -12 mm cement plaster of mix : 1:4 (1 cement: 4 coarse sand) |
| 5 | Cement Plaster in course sand 20 mm cement plaster of mix : 1:4 (1 cement: 4 coarse sand) |
| 6 | Cement plaster 1:3 (1 cement: 3 coarse sand) finished with a floatingcoat of neat cement. 12 mm cement plaster |
| 7 | 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 8 | Extra for providing and mixing water proofing material in cement concrete work in doses by weight of cement as per manufacturer's specification. |
| 9 | Centering and shuttering including strutting, propping etc. and removal of form for Suspended floors, roofs, landings, balconies and access platform |
| 10 | Centering and shuttering including strutting, propping etc. and removal of form for Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 11 | Centering and shuttering including strutting, propping etc. and removal of form for Columns, Pillars, Piers, Abutments, Posts and Struts |
| 12 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more |
| 13 | Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. Concrete of M30 grade with minimum cement content of 350 kg /cum |
| 14 | Add for using extra cement in the items of design mix over and above the specified cement content therein. |
| 15 | Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanitycounters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cementmortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. completeat all levels. Granite stone slab colour black & Chida White Area of slab upto 0.50 sqm |
| 16 | Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with whitecement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. Granite stone slab colour black & Chida White |
| 17 | laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. Granite stone slab colour black & Chida White |
| 18 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shadecomplete. |
| 19 | Fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shadecomplete. |
| 20 | Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 25 mm thick |
| 21 | Rubbing & Polishing of Kota stone complete to provide smooth finish as per the direction of EIC complete. |
| 22 | Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. |
| 23 | Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick Cement Mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including pointing the joints with white cement and matching pigments etc., complete. |
| 24 | laying rectified Glazed Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick Cement Mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including pointing the joints with white cement and matching pigments etc., complete. |
| 25 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm |
| 26 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 27 | Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two or more coats on new work for convention hall |
| 28 | White washing with lime to give an even shade : New work (three or more coats) |
| 29 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : Two or more coats on new work |
| 30 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. Powder coated aluminium (minimum thickness of powder coating 50 micron) |
| 31 | For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required Powder coated aluminium (minimum thickness of powder coating 50 micron) |
| 32 | Filling the gap in between aluminium/ stone/ wood frame and adjacent RCC/Brick/ Stone/ wood/ Ceramic/ Gypsum work by providing weather/structural non sag elastomeric PU sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete, complying to ASTM C920, DIN 18540- F & ISO 11600 Upto 5 mm depth and 5 mm width |
| 33 | Upto 10 mm depth and 10 mm width |
| 34 | Upto 20 mm depth and 20 mm width |
| 35 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . With 6 mm thick toughened glass panes as per griha norms. |
| 36 | Providing and applying crystalline mortar by mixing in the ratio of 4.5 : 1 (4.5 parts crystalline mortar : 1 part water) for the treatment of faulty construction joints, cracks, tie rod holes and spalled & honeycombed surface of RCC underground structures like basement, water tanks, bridge deck etc. to ensure water tightness. The crystallie mortar shall conform to the EN 1504-3 having compressive strength Class R4 -45 MPa and adhesive bond strength Class R3 -1.5 MPa. The work shall be carried out all complete as per specification and the direction of the engineer-in-charge. The product performance shall carry guarantee for 10 years against any leakage. For sealing cracks and faulty construction joints, routed out/making U-shape groove size 25x25mm and then primed the area with integral crystalline slurry @0.05kg/ running metre and while the surface is tacky filled the groove upto surface with crystalline mortar @1.50kg/ running metre. Once crystalline mortar is touch dry then finally applied two coats of integral crystalline slurry @0.05kg/running metre per coat. |
| 37 | Cutting holes of required size in brick masonry wall for fixing of exhaust fan including providing and fixing 300 mm dia PVC pipe conforming BIS-12818 and making good the same etc. complete as per direction of Engineer-in-charge. |
| 38 | Dismantling concrete /morter rubbis by breaker or manually and Cleaning debris, rubbish & dispose the material as per the instruction of Engineer-In-Charge including all manpower, tools & tackles etc. complete. |
| 39 | Providing and fixing permanently color coated profile Lloyd Standing Seam profile sheet or equivalent manufactured out of 0.55 mm TCT (Total Coated Thickness) Galvalume steel (150 gsm. zinc - aluminum alloy coating total of both sides as per AS 1397: 1993) having min.300 Mpa yield strength. The color coating shall comprise of Silicon Modified Paint. The color coating shall comprise of 20 microns finish coat over a 5 micron primer coat on the exposed side and back coat of 5 microns over a primer coat of 5 micron on the reverse side. The sheet shall be standing seam profiled having max. crest height of 63mm at min.418mm pitch distance fixed over a unique concealed clip made from 1.5mm GI which is locked together by a mechanical zipping machine to give absolutely puncture less roof and prevent leakage and shall be profiled at site with suitable fasteners. The work shall be carried out as per specifications, approved drawings and instruction of the Engineer-in-charge. The Profile steel sheets shall conform to IS: 513, 277 & 14246.The sheet & insulation to be manufactured and erected by an ISO: 9001 certified company. |
| 40 | Providing ridges or hips of width 60 cm overall width plain G.S. sheet fixed with polymer coated J or L hooks, bolts and nuts 8 mm dia G.I. limpet and bitumen washers complete. 0.63 mm thick with zinc coating not less than 275 gm/m² |
| 41 | Providing and fixing thermal insulation of ceiling (under deckinsulation) with Resin Bonded Rockwool conforming to IS: 8183,density 48 kg/ m3, 50 mm thick, with aluminium foil insulation on the facing side over the metal mesh bed (50X50X1.6mm) by tying GI wire crisscross through the cleats and as per technical specification and as per the instruction of EIC complete. |
| 42 | Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, fabrication & fixing of Gutter including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer & paint including all necessary staging work complete as per direction of EIC. |
| 43 | Pressure grouting of all RCC floor and walls including chiselling/drilling 16mm dia holes in grid pattern in all joints and honey combs (spacing less than 300cm (centre) fixing flexible rubber nozzles using repair setting compound. The cement slurry used for pressure grouting will be mixed with expensive admixyure (cubex 100) at the rate of 100ml per bag of cement. The prepared slurry will be injected through prefixed nozzles under pressure using grouting pump to fill all possible voids and gaps in concrete. After stopping of slurry flows the nozzles will be sealed of grouting operation will be carried out till completion of Job. 26684886.41 B SANITARY & PLUMBING WORK |
| 44 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.Concealed work, including cutting chases and making good the wallsetc.make-Prince 20 mm nominal dia Pipes |
| 45 | 25 mm nominal dia Pipes |
| 46 | 32 mm nominal dia Pipes |
| 47 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and including testing of joints complete as per direction of Engineer in Charge 40 mm nominal dia Pipes |
| 48 | 50 mm nominal dia Pipes |
| 49 | 65 mm nominal dia Pipes |
| 50 | 80 mm nominal dia Pipes |
| 51 | 100 mm nominal dia Pipes |
| 52 | Providing and fixing of following dia UPVC-Soil and Waste pipes (Type-B) (Co-moulded Ring type) confirming to latest IS IS-13592 with ISI markedboth below & above ground level or fixing on wall surface in all floors with holder bat clamps screw in all floors as per specification & testing the joints with required water presure. as per specification and direction of Engineer-in-charge. 75 mm |
| 53 | 110 mm |
| 54 | Providing and fixing of uPVC SWR pipes (Type-A)(Co-moulded Ring type) of approved make confirming to IS-13592/1992with ISI marked, both below & above ground level or fixing on wall surface in all floors including clip & plug transportation & scaffolding etc. all complete as per specification & direction of the Engineer-in-charge. 160mm |
| 55 | Providing and fixing cPVC ball valve with SS 304 Stem and ball, teflon seat complete (PN-16). 20 mm |
| 56 | 25 mm |
| 57 | 32 mm |
| 58 | 40 mm |
| 59 | 50 mm |
| 60 | 65 mm |
| 61 | 80 mm |
| 62 | Providing and fixing gun metal non- return valve of approved quality(screwed end) :as per direction of Engineer in Charge 65 mm nominal bore |
| 63 | 80 mm nominal bore |
| 64 | Providing and fixing enclosed type water meter (bulk type) conforming to IS : 2373 and tested by Municipal Board complete with bolts, nuts, rubber insertions etc. (The tail pieces if required will be paid separately) in complete as per direction of Engineer in Charge 80 mm dia nominal bore |
| 65 | Providing and fixing C.I. dirt box strainer for bulk type water meter with nuts, bolts, rubber insertions etc. complete conforming to IS : 2373 : in complete as per direction of Engineer in Charge 80 mm dia |
| 66 | Providing & fixing CI double acting air release valve of approved quality with bolts, nuts, rubber insertion etc complete.as per direction of Engineer in Charge 50 mm |
| 67 | 80 mm |
| 68 | Supplying all materials, labour, T&P fitting and fixing of following dia uPVC SWR fittings of approved make confirming to IS-14735 with ISI marked in all floor with transportation & requiste testing as per specifications and as per direction in charge 110mm x110mm P-trap |
| 69 | 110mm x87.50 Plane bend |
| 70 | 110mm x87.50 bend with door |
| 71 | 110mm x450 Plane bend |
| 72 | 110mm dia single 'Y' without door |
| 73 | 110mm WC connector/ bend with lip ring |
| 74 | 110mm Pushfit coupler |
| 75 | 160mm x450 Plane bend |
| 76 | 160mm x87.50 Plane bend |
| 77 | 160mm x87.50 bend with door |
| 78 | 160mm dia single 'Y' without door |
| 79 | 160mm dia single 'Y' with door |
| 80 | Provoding, fixing, testing and commissioning of approved make PVC vent cowl with necessary accessories etc, complete. 110 mm dia |
| 81 | Providing and fixing high quality Stainless Steel Popup Floor Drain( Dimension: 160mm x 160 m) Highly durable shine and strength, Rust and corrosion Proof complete in all respect.as per specifications and as per direction in charge |
| 82 | Providing and fixing high quality Stainless Steel floor Trap(Cockroach Trap Square type Square Flat Cut Stainless Steel AISI 304 (18/8) Floor Drain Cover/Jali/Grating (Glossy Finish) complete in all respect. |
| 83 | Providing and fixing high quality Stainless clean out plug size 100 mm Highlydurable and strength complete in all respect.as per specifications and as per direction in charge |
| 84 | Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design: 150 x 100 mm size P type with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 3369270.99 30054157.4 Please Enable Macros to View BoQ information |