| 1 | Taking down Post top lantern/beautification luminaires/MH fittings of any builiding & post top after disconnecting all eletrical connection for repair/replacement of old parts if any works and refixing the same after replcement of burnt/unserviceable spares & cleaning the luninaires by mild cleanser complete all as specified and as directed. (None : Spares/ Accessories will be measured & paid separatly under supply only rate). |
| 2 | Supply and fix LED Post top lantern of 50 Watts, 240V, 50Hz IP 65 made of black ABS plastic spigot, spun aluminium funnel shape with clear acrylic and accessories such as integrated drivers pre-wired etc suitable with gate light pipe. |
| 3 | Supply and fix LED Post top lantern of 25 Watts, 240V, 50Hz IP 65 made of black ABS plastic spigot, spun aluminium funnel shape with clear acrylic and accessories such as integrated drivers pre-wired etc suitable with gate light pipe. |
| 4 | Supply and fix LED Post top lantern of 05 Watts, 240V, 50Hz IP 65 made of black ABS plastic spigot, spun aluminium funnel shape with clear acrylic and accessories such as integrated drivers pre-wired etc suitable with gate light pipe. |
| 5 | Supply and fix IP 65 rated pyramid tripod type LED bollard with soft 360 degree light distribution of 15 watt complete with stand |
| 6 | Supply and fix LED floodlight of 50 Watt made up of pressure die cast aluminium housing with toughened glass and high power LEDs with IP66 protection. |
| 7 | Supply and fix LED floodlight of 80 Watt made up of pressure die cast aluminium housing with toughened glass and high power LEDs with IP66 protection. |
| 8 | Supply and fix LED floodlight of 120 Watt made up of pressure die cast aluminium housing with toughened glass and high power LEDs with IP66 protection. |
| 9 | Supply and fix LED floodlight of 400 Watt made up of pressure die cast aluminium housing with toughened glass and high power LEDs with IP66 protection. |
| 10 | Supply and fix as in replacement LED street light fitting 70 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specifed and directed. |
| 11 | Note against BOQ SL No 02 to 10:- (a) LM-80 certificate from NABL accredited Lab shall be submitted for LED light fittings.(b) Warranty certificate shall be submitted for LED light fitting as per standered format for minium 50000 Hrs.(c) LED light fitting and drivers shall be of same make. |
| 12 | Supply and laying, connecting, testing, commissioning LT UG cable XLPE Insulated,armoured, electric power cables (heavy duty) 1100 Volts grade conforming to IS 7098 with aluminium conductor multi-strand of cross-sectional area 10 Sqmm 2 Core laid in trenches / ducts/ inside protection pipe including cable glands, lugs and suitable size of MS saddle clips etc. also taking out existing unserviceable UG cables all as directed by Engr-In-Charge.Note:-(a) Excavation, sand cushioning, bricks shall be measured and paid separately |
| 13 | Supply and laying, connecting, testing, commissioning LT UG cable XLPE Insulated,armoured, electric power cables (heavy duty) 1100 Volts grade conforming to IS 7098 with aluminium conductor multi-strand of cross-sectional area 16 Sqmm 4 Core laid in trenches / ducts/ inside protection pipe including cable glands, lugs and suitable size of MS saddle clips etc. also taking out existing unserviceable UG cables all as directed by Engr-In-Charge.Note:-(a) Excavation, sand cushioning, bricks shall be measured and paid separately |
| 14 | Supply, lay and fix 40 mm bore galvanized iron tubing (light grade) including all fittings and laid in trenches, walls and ceilings or laid in floors complete all as specified and directed.Note: Excavation shall be measured and paid in separate item |
| 15 | Material and labour for PVC insulated FRLSH industrial cable with multi stranded copper conductor 2.5 sqmm 3 core, 1100 volts including taking out old cable as directed by Engineer-In-Charge. |
| 16 | Supply and fix as in repairs cable junction box of size 240 mm x 130 mm x 110 mm with terminals / connectors, mounting bracket & polyamide cable gland with lock nut & bolts including internal connections with proper size Copper/ Aluminum lugs/ thimbles including fixing on pole with clamps and also drilling of two holes on pole for inserting PVC insulated copper cable complete all as directed. |
| 17 | Material and labour for preparation of old painted steel surface of LT Poles of height 8.5 / 9 mtrs height of LT OH line or street light steel tubular poles above ground level coping including cross arm channels, flat iron clamp in LT OH line by scrapping with wire brush and applying two coats of aluminium paint including pole numbering all as specified and directed by Engineer-in-Charge. |
| 18 | Material and labour for p[reparation of external and internal old painted steel surfaces of LT panel boards/ LT feedar pillar boxes/ bus bar chambers, GI pole and bollard etc in position by removing/ scrapping old disintegrated and deteriorated paint and painting two coats of synthetic enamel paint by spray gun over a coat of red oxide primer including welding work for doors and writing letter complete all as directed by Engineer-In-Charge. |
| 19 | Material and labour for dismantling shaft of AHU plant, transporting to workshop, re-metalling, grinding, machining on lathe and other machines to bring the same in size to fit with bearing for proper functioning, transporting back to AHU plant and re-installing/ commissioning the shaft & pulley with proper alignment complete all as specified and directed. |
| 20 | Supply and fix of shaft bearing as per existing type and recommissioning the shaft/ pulley with proper alignment all as directed by Engineer-In-Charge. |
| 21 | Supply only heat proof porcelain insulator with suitable size nuts/bolts & washers as per sample. |
| 22 | Supply only V-belt of type B-84 to B-95 as per existing size Please Enable Macros to View BoQ information |
| 23 | Supply only V-belt of type B-84 to B-95 as per existing size Please Enable Macros to View BoQ information |