| 1 | Servicing / Preventive maintenance of the following equipments of different capacities by carrying out regular maintenance such as checking of cooling coils, condensers, electric motors of different types and compressors and other parts, cleaning washing with suitable cleaning agent/chemical using vacuum cleaner, Jet spray servicing, replacement of rubber wheels, bolts & nuts, screws check nuts, PVC sleeves and thimbles, and other parts as required, checking all electrical parts and electrical wiring etc, tightening of electrical connections, greasing of electric motors, checking of gas pressure and gas charging to the desired pressure to ensure serviceability regularly through out the contract period complete all as specified and as directed for the following :-(a) 1.5/2.0/3.0 tons capacity split type ACs |
| 2 | (b) Water coolers of any capacity |
| 3 | (c) Refrigerators capacity 165 to 310 Ltr |
| 4 | (d) Defumidifier upto 2500 Cumf |
| 5 | (e) Cassette AC upto 3TR |
| 6 | (f) Deep freezer and ice making machine |
| 7 | Taking out sealed/ old burnt compressor of split type AC 1.5 ton and S&F of new sealed compressor of approved make as per reciprocating type suitable for 1.5 Ton capacity AC and connecting up suction and discharging pipe line with gas welding complete all as specified and directed by Engr-in-Charge. Make: M/s Kirloskar / M/s Carrier/M/s Voltas/ M/s Bluestar. |
| 8 | All as per item No. 2.00 but split type AC 2 Ton capacity complete all as specified and as directed. |
| 9 | Taking down split type AC and taking out rotary type sealed compressor of split type AC 1.5 ton capacity and S&F new sealed rotary type compressor of approved make and discharging pipe line with gas welding and refixing the repaired AC in its original position complete all as specified and directed by Engr -in-Charge |
| 10 | All as per item No. 4.00 but split AC 2.0 ton capacity complete all as specified and as directed. |
| 11 | S & F in replacement copper cooling coil assembly for 1.5 ton air conditioner of approved make including testing and commissioning complete all as directed by Engr-in-Charge. |
| 12 | S & F in replacement of copper cooling coil assembly for 2.0 ton air conditioner of approved Make, commissioning complete all as specified and as directed. |
| 13 | S & F in replacement condenser coil assembly suitable for 1.5 ton air conditioner including testing and commissioning complete all as specified and as directed. |
| 14 | S & F in replacement condenser coil assembly suitable for 2.0 ton air conditioner including testing and commissioning complete all as specified and directed. |
| 15 | S & F in replacement running capacitor 36 mfd, 3 pole & 2 pole suitable for 1.5 ton window / split type air conditioner. Make M/s Asian / M/s Unistar / M/s Epcos / M/s Electro all as specified and as directed. |
| 16 | S & F in replacement running capacitor 45 mfd, 3 pole & 2 pole suitable for 2.0 ton window / split type air conditioner. Make M/s Asian / Ms Unistar M/s Epcos / M/s Electro all as specified and as directed. |
| 17 | S & F in replacement starting capacitor 100 to 120 mfd suitable for 1.5 ton window / split type air conditioner. Make M/s Asian / M/s Unistar / M/s Epcos / M/s Electro all as specified and as directed . |
| 18 | S & F in replacement starting capacitor 100 to 150 mfd suitable for 2.0 ton capacity window / split type air conditioners. Make M/s Asian / Ms Unistar M/s Epcos / M/s Electro complete all as specified and as directed. |
| 19 | S&F in replacement starting relay suitable for 1.5 Ton / 2.0 Ton / 3.0 Ton of Split / Window type AC make M/s Sriram / M/s Renutral all as specified and as directed. |
| 20 | S & F in repairs of thermostat switch for window / Split type Air conditioner of 1.5 / 2.0 / 3.0 Ton capacity. Make M/s Renutral / M/s Denfoss all as specified and as directed. |
| 21 | M & L for gas charging R-22 in split type AC 1.5 / 2.0 / 3.0 ton capacity of approved make and type including pressure testing, leakage, vaccumising, rectification, testing and commissioning complete all as specified and as directed. |
| 22 | M & L for gas charging R-32 in window type split type AC 1.5 / 2.0 / 3.0 ton capacity of approved make and type including pressure testing, leakage, vaccumising, rectification, testing and commissioning complete all as specified and as directed. |
| 23 | S & F in repair / replacement electric wiring kit (PCB) suitable for 1.5 ton / 2.0 ton Split type air conditioner invertor type AC (indoor unit and outdoor unit) complete set of any make and type complete all as specified and as directed. Note: New PCB shall be as per the existing make and size as required should be provided by the contractor |
| 24 | M&L for Shifting of Split type Air Conditioner of any type and make, up to 2 TR from existing location to other location and installing indoor and outdoor units as directed including provision of necessary brackets (L type) clamps, GI nuts, bolts and washers etc for fixing of indoor / outdoor units with and including topping up of refrigerant gas and Nitrogen pressure test to find out leakage, commissioning and testing and making good disturbed surface complete all as specified & directed. Note : PVC pipe for protection , drain pipe , control cable, extra copper tubing of any size for suction / discharge will be measured and paid separately. |
| 25 | M&L for Shifting of Window type Air Conditioner of any type and make, up to 2 TR from existing location to other location and installing as directed, commissioning and testing including making opening of required size in walls or existing windows of any type, provision of necessary brackets, clamps, GI nuts, bolts and washers etc for fixing of AC,and making good disturbed surface of walls and windows complete all as specified & directed. Note : (i) PVC drain pipe , control cable where required will be measured and paid separately. |
| 26 | S & F in repair/replacement electric wiring kit (PCB) suitable for 1.5 ton / 2.0 ton Window type air conditioner of any make and type complete all as specified and as directed. Note: New PCB shall be as per the existing one. |
| 27 | Supply in replacement Remote assembly cordless as per existing make and size window/split type AC's as per AC make complete as specified. |
| 28 | Taking down corroded body base tray etc of Split type AC of 1.5 Ton / 2 Ton capacity and replacement of body base tray etc made out of 18 SWG mild steel and other portion of mild steel sheet of 20 SWG including motor mounting frame fix with nuts and bolts of suitable size and painting with one coat of black enamel paint and necessary insulation complete all as specified and as directed. Note :- Unit rate quoted shall also deemed to include for reassembling. |
| 29 | S & F in replacement of fan blade of motor for window type AC of capacity 1.0 ton / 1.5 ton / 2.0 ton of make M/S Asian or equivalent complete all as specified and as directed. |
| 30 | S & F in replacement blower fan motor for 1.0 ton / 1.5 ton / 2.0 ton split AC capacity air conditioners including testing, complete all as specified and as directed. Make: Blower fan motor shall be as per the existing one. |
| 31 | S & F in replacement blower drum suitable for window/split type AC of capacity 1.0 ton / 1.5 ton / 2.0 ton completeall as specified and as directed. Note: Blower drum shall be as per the existing one. |
| 32 | S & F in replacement blower motor capacitor 10 mfd suitable for 1.5 ton split type air conditioner complete all as specified and as directed. |
| 33 | S & F in replacement blower motor capacitor 15 mfd suitable for 2.0 / 3.0 ton split type air conditioner complete all as specified and as directed. |
| 34 | S&F in replacement copper suction pipe line of size 1/2\\" dia and other all as per manufacturers recommendation complete with cutting, brazing work and insulation including fittings required at site complete all as specified and directed by Engr-in-Charge. |
| 35 | S&F in replacement copper discharge pipe line of size 1/4\\" dia and other all as per manufacturers recommendation complete with cutting, brazing work and insulation including fittings required at site complete all as specified and directed by Engr-in-Charge. |
| 36 | Supply and fixing in replacement cable PVC insulated PVC unsheathed, multistranded, 1100 volts grade (ISI marked) 4 core 2.5 Sq mm with flexible copper conductor suitable for Split type AC and Window type AC complete all as specified and as directed. Make:- Havells, Polycab, Plaza. |
| 37 | Supply and fixing in replacement suitable size PVC pipe, heavy duty for drain out of condensing water of split type air conditioner including cutting of floors or making hole in wall and making good the disturbed portion after laying pipe etc to match the existing surface with original specifications complete all as specified and as directed. |
| 38 | S & F in replacement synthetic air filter suitable for split/window type air conditioner any capacity complete all as specified and as directed |
| 39 | M&L for Flushing out the nitrogen gas from condensing coil of AC 1.5 Ton capacity (Window/split) complete and repairs of leaking place by gas welding complete and recharging of refrigerant (R-22 & R-32) all as directed (Refrigerant shall be measured and paid in respective item of Sch 'A'). |
| 40 | M&L for Flushing out the nitrogen gas from condensing coil AC 2 Ton (window/split) capacity complete and repairs of leaking place by gas welding complete and recharging of refrigerant (R-22 & R-32) all as directed (Refrigerant shall be measured and paid in respective item of Sch 'A'). |
| 41 | S&F in repair, capillary tube for Spilt type AC including brazing and connecting with existing system complete all as specified and directed by Engr-in-charge. |
| 42 | S&F in repair, wiring kit for Window/split AC of any capacity comprising of copper conductor cables for connections of assembly, complete all as specified and directed by Engr-in-charge. Please Enable Macros to View BoQ information |
| 43 | S&F in repair, wiring kit for Window/split AC of any capacity comprising of copper conductor cables for connections of assembly, complete all as specified and directed by Engr-in-charge. Please Enable Macros to View BoQ information |