| 1 | Providing pre cast PCC type B-1 (1:2:4) in window or door cills, lintels, bressumers, steps, quoin blocks (for use with masonry), string courses, copings. kneelers, apex stones, pier caps, columns, posts, boundary pillars, bed plates, pintle blocks, ancho-rage blocks, bonders (for stone walling). corbels, brackets, etc. (of any section indicated), with plain fair faces, including chamfers, weatherings, throat- ing etc. and setting in mortar complete with joints to match set in CM (1:6) complete all as specified and directed. |
| 2 | M&L Mild steel TMT bars 10 mm dia and over cut to length, bent to shape required incl cranking, hooking ends and binding with and including MS wire (annealed) not less than 0.9mm dia complete all as specified and directed. |
| 3 | M&L Mild steel TMT bars 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders cut to length, bent to shape required incl cranking, hooking ends and binding with and including MS wire (annealed) not less than 0.9mm dia complete all as specified and directed. |
| 4 | S&F collapsible steel gates, top hung, consisting of hot rolled medium channel 18x9x3mm channel pickets & distance from centre to cntre of channel picket 10cm, pivoted flat bars for croosing 18x5mm,tee and flats for top and bottom runners with a minimum web of 40x12mm and flange of 40x6mm, brass handles etc, as specified, erected in position and securing runners with holdfasts and brackets, complete all as specified and directed. |
| 5 | S&F MS framed work such as grills, gratings, hold fast etc with ends of bars shouldered and or riveted or forged into spikes, framed guard bar, barred iron door, ladders, framed balusters, walk way, railings frame work of water tank and similar work confirming to Fe 290 Gde E165 complete all as specified and directed. |
| 6 | M&L for Steel ventilator with top hung shutter including hinges, steel peg stay, complete complete all as specified and directed. |
| 7 | S&F of 3 mm thick ordinary glass and glazing with oil putty or fixed with oil putty in square not exc. 0.5 sqm in each pane complete all as specified and directed. |
| 8 | S&F powder coated aluminium frame (minimum thickness of powder coating 50 micron) for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc complete all as specified and directed. |
| 9 | S&F powder coated aluminium grill wt not less than 2.5kg/sqm (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved aluminium standard section around the opening, complete all as specified and directed. |
| 10 | S&F SS wire cloth, 0.56 mm nominal dia of wire and average width of aperture 1.18 mm and fixed with tinned tack/ galvanised wire staple complete all as specified and directed. |
| 11 | M&L for preparation of newly steel and iron surfaces of any description exc 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide complete all as specified and directed. |
| 12 | Providing and fixing tiled false ceiling of designer tiles (high pressure steam Cured) of 4mm thickness (as per IS:14862) of size 595x595mm and any one of the design (Cascade or Electra or equivalent) in true horizontal level, suspended on inner locking metal grid of hot dipped galvanized steel sections (galvanized @ 120 grms, both side inclusive and black painted groove on all T webs) consisting of main “T” runner with suitably spaced joints to get required length and 15x32mm made from 0.3mm thick sheet, 1200mm long spaced between main “T” at 600mm C/C to form a grid of 1200x600mm and secondly cross “T” of length 600mm and size 15x32mm made of 0.30mm thick sheet to be interlocked at middle of 1200x600mm panel to form grids of 600x600mm and wall angle 15x20x0.36mm and laying false ceiling tiles in the grid including, required cutting / making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main “T” runners to be suspended from ceiling using GI soffit cleats fixed to existing RCC lintel with dash fasteners, GI adjustable rods of 3mm dia with galvanized butterfly level clips, spaced at 1200mm c/c along main “T”, bottom exposed width of 15mm of all “T” sections shall be pre-painted with polyester paint and black painted groove at center of size 4mm depth and 4.5 mm width, all complete at all heights as per directions of EIC and complete all as specified and directed. |
| 13 | Cutting openings, through brick walls (built in cemnet mortar) for door, window and other openings or enlarging existing openings. converting window into door openings, etc. or cutting out defective brick work for under-pinning, including providing, fixing and removing shoring, cleaning and stacking bricks, removing surplus serviceable bricks, hard-core, etc to store and rubbish not exc. 50m and making good of the disturbed surface with CM (1:6) complete all as specified and directed . |
| 14 | M&L for preparation of newly plastered or unplastered surfaces of walls and applying 1.00mm thick wall care putty on wall surfaces and a coat of wall primer and two coats of oil bound distemper (White or tinted) complete all as specified and directed. |
| 15 | M&L for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10sqm on new surfaces of wall complete all as specified and directed. |
| 16 | M&L for complete removal of existing treatment from walls, cornices etc by brooming down or steel wire brushing, scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots and applying 1.00mm thick wall care putty of approved makes on wall surfaces and two coats of oil bound distemper (White or tinted) complete all as specified and directed. |
| 17 | M&L for complete removal of existing treatment on walls, cornices etc by brooming down or steel wire brushing, scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots and applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/10 sqm including priming coat of exterior primer applied @ 0.90 litre/10sqm complete all as specified and directed. |
| 18 | Dismantling structural steel as in gates or posts complete all as specified and directed. |
| 19 | M&L for PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) as in bed block for inserting hold fast and coping including necessary form work complete all as specified and directed. |
| 20 | Demolition of cement concrete etc (un-reinforced) of any description removal of rubbish complete all as specified and directed. |
| 21 | S&F in repair Galvanised 2 strand steel barbed wire 2.24 mm barbed with 2 mm dia barbs @ 75 mm spacing straining and fixing including securing or lying at crossing with and provision of galvanised MS staples or steel pins incl dismantling of old barbed wire complete all as specified and directed. |
| 22 | M&L MS works as in Posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire etc; flat iron fillets for securing wire mesh etc) including all necessary drilling bolting or riveting etc and similar work confirming to Fe 290 Gde E-165 complete all as specified and directed. |
| 23 | Demolition of brick work or stone/boulder masonry built in cement mortar or cement lime mortar including all quoins, arches, pillars etc but excluding ashlar facings, dressed stone work and precast concrete articles complete all as specified and directed. |
| 24 | M&L brick work with sub class 'B' brick straight or curved on plan exc 6 m mean radius built in CM (1:6) complete all as specified and directed. |
| 25 | Taking down cement or cement lime plaster from brick or stone walls etc including racking out joints, hacking for keys, scrubbing down with water etc complete all as specified and directed. |
| 26 | M&L for rendering 15 mm thick cement plaster in cement mortar (1:4) on fair faces of brickwork or concrete surfaces in walls and finishing surface even and smooth without using extra cement etc complete all as specified and directed. |
| 27 | M&L for rendering 15 mm thick cement plaster in cement mortar (1:4) on other than fair faces of brickwork or concrete surfaces in walls and finishing surface even and smooth without using extra cement etc complete all as specified and directed. |
| 28 | M&L for preparation of newly plastered surfaces of wall and applying two coat of cement base paint complete all as specified and directed. |
| 29 | M&L for preparation of old decorated wall surfaces and applying one coat of cement base paint complete all as specified and directed. |
| 30 | Providing and fixing concertina coil fencing with punched tape concertina coil 600 mm dia 10 meter openable length (total length 90 m), having 50 Nos round per 6 metre length fixed up to 3 m height of wall with existing angle iron Y shaped placed 2.4 m or 3.00 m apart and with 9 horizontal R.B.T. reinforced barbed wire, stud tied with GI staples and GI clips to retain horizontal, including necessary bolts or GI barbed wire tied to angle iron, with reinforced barbed tape (R.B.T.)/ Spring core (2.5 mm thick) wire of high tensile strength of 165kg/ sq. mm with tape (0.52 mm thick) and weight 43.478 gm/ metre (cost of MS angle, CC. blocks shall be paid separately) complete all as specified and directed. |
| 31 | Taking down carefully U/S copper/aluminium point wiring (light, fan, socket, power) complete fitting such as switches, ceiling roses, pendants, lamp holder, light fitting etc including CI/Pressed steel terminals, switch box, and making good the disturbed surface of wall/floor etc, to match with the existing surfaces of wall/floor complete all as specified & directed. |
| 32 | Taking down carefully sub-main wiring/ service wire of any size including wooden batten etc and making good the disturbed surfaces of wall/floor to match with the existing wall/floor etc complete all as specified and directed. |
| 33 | Taking down carefully existing DB’s any type and making good the disturbed surfaces of wall/floor to match with the existing wall/floor etc complete all as specified and directed. |
| 34 | M&L for point wiring with 1.5 sq mm PVC insulated, unsheathed, multi stranded copper conductor (FRLS-H) cable single core 1100 Volt grade in and including rigid PVC conduit medium grade 20mm dia or more ISI Marked concealed conduit and conduit accessories and cutting chases of suitable girth where required on brick/concrete surface & making good disturbed surface,provision of GI/Pressed steel terminal switch box with plastic laminated sheet 3 mm thick fixed with brass screw and washers along with 1.5 sq mm PVC insulated unsheathed stranded copper conductor cable (FRLS-H) as earth wire connected with main common earth dolly complete all as specified and directed for the following :-One light/fan/bell/exhaust fan point controlled by one, switch 5/6 Amp. |
| 35 | One 3pin/5pin 5/6 Amps socket out let on same board controlled by one, switch. |
| 36 | One 3pin/5pin 5/6 Amps socket out let on independent board controlled by one, switch. |
| 37 | All as per item No 34 here-in-before but wiring with 2.5 sqmm single core multi stranded copper condcutor 1100 V grade PVC insulated FRLS-H but unsheathed single core for 16 Amps power point on independent board and 2.5 sqmm FRLS-H cable as earthwire complete all specified and directed. |
| 38 | S&F switch piano flush type white finish 5/6 Amps, single pole one way, 230 volts, 50 hz complete all as specified & directed. |
| 39 | S &F socket out let 2 pin 5/6 Amps & 3 pin 5/6 Amps flush type, 230 volts, 50 hz all as specified and directed. |
| 40 | S&F switch piano flush type white finish 15/16 Amps single pole one way, 230 volts, 50 hz all as specified and directed |
| 41 | S &F socket out let 5 pin 15/16 Amps & 3 pin 5/6 Amps flush type, 230 volts, 50 hz all as specified and directed. |
| 42 | S&F fan regulator, flush stepped type ,electronic type compatible with the existing fan at site of suitable rating complete all as specified and directed. |
| 43 | S&F lamp holder (Angular/Straight) insulated body, with back plate for batten fitting complete all as specified & directed. |
| 44 | S&F LED Bulb 9 Watt (cool day light) fix on batten holder complete all as specified and directed. |
| 45 | M&L ceiling rose 3 terminal/PVC/polycarbonate, isolated body complete all as specified and directed. |
| 46 | S&F in replacement of power unit MCB protected plug and socket board in sheet steel enclosure with 25 Amp rated mini MCB and 25 Amp rated 3 pin plug, 240 V, 50 Hz complete including cutting the wall surfaces for flush mounting of socket board including taking down existing unserviceable plug & socket board of any description and making good with cement plaster, putty and paint to match with the existing surface complete all as specified and directed. |
| 47 | S&F sheet metal enclosure double door type for MCBs DB SPN (Single pole and neutral) 240V AC 2 way with 32 Amps rated busbar complete all as specified and directed. |
| 48 | S&F sheet metal enclosure double door type for MCBs DB SPN (Single pole and neutral) 240V AC 4 way with 63 Amps rated busbar complete all as specified and directed. |
| 49 | S&F sheet metal enclosure double door type for MCBs DB SPN (Single pole and neutral) 240V AC 8 way with 100 Amps rated busbar complete all as specified and directed. |
| 50 | S&F MCB, SP, AC, 240 volts of 06 to 32 Amps capacity 10KA, 'C' series and making connections with suitable size of copper lugs complete all as specified & directed. |
| 51 | S&F MCB, SPN, AC, 240 volts of 40 Amps capacity 10KA, 'C' series and making connections with suitable size of copper lugs complete all as specified & directed. |
| 52 | S&F LED tube light batten 20 watts 4 fts extruded polycarbonate housing, translucent diffuser with LED light source, 2000 lumen, natural white ,surge protection range- 2KV, voltage protection range 120-280 VAC with intergrated driver and surge protection complete all as specified and directed. |
| 53 | S&F LED 25 watt Building security light fitting mounting type made out of one piece in pressure die-cast aluminium housing with high efficient LED as lighting source and PC Cover separate compartment for driver, including bracket clamp of GI pipe light grade of 40 mm dia and fixing accessories complete with electronic driver and all accessories. The fitting shall IP 66 protection, duly prewired complete all as specified and directed. |
| 54 | S&F sub main wiring two single core 6 sq mm PVC insulated unsheathed stranded copper conductor cable (FRLS-H) 1100Volts grade drawn in & including rigid PVC conduit 20mm dia or more medium grade concealed in wall along with 6.00 Sq mm PVC insulated unsheathed copper conductor cable (FRLS-H) as earth wire and wire connected with main earth dolly including cutting chasing and making good disturbed portion complete all as specified and directed. |
| 55 | S&F sub main wiring two single core 4 sq mm PVC insulated unsheathed stranded copper conductor cable (FRLS-H) 1100Volts grade drawn in & including rigid PVC conduit 20mm dia or more medium grade concealed in wall along with 4 Sq mm PVC insulated unsheathed copper conductor cable (FRLS-H) as earth wire and wire connected with main earth dolly including cutting chasing and making good disturbed portion complete all as specified and directed. |
| 56 | Taking down old unserviceable ceiling fan & refixing the same to its original position after completion of surface finishing work with necessary repair works such as greasing, bearing change & capacitor change and necessary accessories such as down rod, canopy, safety pin etc complete all as specified and directed. |
| 57 | S&F Exhaust fan PVC body AC single phase 230/240 Volt of size 250 mm sweep complete with louvers shutter including making whole and grouting of nut bolts etc and making good the disturbed sufaces of wall complete all as specified and directed. |
| 58 | S&F of MCCB/MCB distribution board, Vertical TPN, 4 way, 415 V, 3 phase, AC with MCCB as incomer and MCBs as outgoing in sheet steel powder painted enclosure double door type with minimum IP 43 degree of protection with built in copper bus bar of capacity 200 Amps, neutral link and earth link complete including cutting the wall surfaces for flush mounting of DB and making good with cement plaster, putty and paint to match with the existing surface including taking down existing unserviceable MCB DB of any description complete all as specified and directed.Note: MCCB / MCBs shall be measured and paid separately. |
| 59 | S&F MCCB 100A, 15/16 KA, 4 Pole, 415 V, Ics=100% Icu, 50 Hz with fixed thermal magnetic release fixed in Vertical TPN complete all as specified and directed.Note: MCCB should be of same make as of VTPN 4 way |
| 60 | M&L for earthing complete with galvanised steel earth plate electrode 600x600x6mm thick burried directly in ground. (earth pit not less than 2.25 mtr depth below ground level at any type of strata ) with top edge of the earth plate not less than 1.5mtr below normal ground level surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15cm all around the plate. connected by GI wire 4.0 sqmm as earth lead by means of brass nuts and bolt,thimbles check nuts, washers including concrete chamber of PCC 1:3:6 type C-1 using 20mm graded stone aggregate with fair finish, internal surface of concrete chamber shall be given internal dia 300mm x300mm, 15mm thick plaster in CM 1:4 funnel with wire mesh, RCC pit cover of 320x320x80mm size (1:2:4) Type B1 using 20mm graded stone aggregate rainforced with XPM all as shown in electrical plate No 3 of MES SSR Part-1(2009) and specified including and provision of GI wire upto 7.5 mtrs long with 15 mm dia light grade Gi pipe protection and watering pipe of GI 20 mm bore, medium grade, including all exavation and earth work and connecting the earthing wire to panel, including testing on completion complete all as specified and directed by Engr-in-charge. Note:- (i) RCC pit cover shall be precast of RCC(1:2:4) type B1, 80mm thick rainforced with XPM weighting not less than 4kg/sqm in lieu of CI cover.(ii) Cost of additional GI wire more than 7.5 mtrs will be measured and paid seperately under relevant items. |
| 61 | M&L for earthing complete with galvanised steel earth plate electrode 600x600x6mm thick burried directly in ground. (earth pit not less than 2.25 mtr depth below ground level at any type of strata ) with top edge of the earth plate not less than 1.5mtr below normal ground level surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15cm all around the plate. connected by GI strip of size 25x4 mm as earth lead by means of brass nuts and bolt,thimbles check nuts, washers including concrete chamber of PCC 1:3:6 type C-1 using 20mm graded stone aggregate with fair finish, internal surface of concrete chamber shall be given internal dia 300mm x300mm, 15mm thick plaster in CM 1:4 funnel with wire mesh, RCC pit cover of 320x320x80mm size (1:2:4) Type B1 using 20mm graded stone aggregate rainforced with XPM all as shown in electrical plate No 3 of MES SSR Part-1(2009) and specified including and provision of GI wire upto 7.5 mtrs long with 15 mm dia light grade Gi pipe protection and watering pipe of GI 20 mm bore, medium grade, including all exavation and earth work and connecting the earthing wire to panel, including testing on completion complete all as specified and directed by Engr-in-charge. Note:- (i) RCC pit cover shall be precast of RCC(1:2:4) type B1, 80mm thick rainforced with XPM weighting not less than 4kg/sqm in lieu of CI cover.(ii) Cost of additional GI strip more than 7.5 mtrs will be measured and paid seperately under relevant items. |
| 62 | Dismantling & taking out old unserviceable LT UG cable and Supplying & laying in replacement of LT UG cable (Conforming to IS 1554) ISI marked1.1 KV grade XLPE insulated PVC sheathed steel armoured aluminum stranded conductor in trenches/ducts/ through HDPE pipe under roads of any size 70 sqmm 3.5 core complete all as specifed and directed. |
| 63 | Supplying & laying in replacement of LT UG cable (Conforming to IS 1554) ISI marked 1.1 KV grade XLPE insulated PVC sheathed steel armoured aluminum stranded conductor in trenches/ducts/through HDPE pipe under roads of size 25 sq mm 4 core complete all as specifed and directed. Note;- The earth work shall be measured and paid sepretely under appropriate item of Sch A |
| 64 | Supplying & laying in replacement of LT UG cable (Conforming to IS 1554) ISI marked 1.1 KV grade XLPE insulated PVC sheathed steel armoured aluminum stranded conductor in trenches/ducts/through HDPE pipe under roads of size 10 sq mm 4 core complete all as specifed and directed. Note;- The earth work shall be measured and paid sepretely under appropriate item of Sch A. |
| 65 | Fabrication, supply, installation, testing and commissioning electrical cubical control LT panel board (KIOSK TYPE) Double door, IP 65 protection, CPRI approved an ISO 9001 factory assembled made out door pedestal type feeder pillar box weather and vermin proof fabricated of 3.0mm CRCA MS sheet of Suitable size,3 phase 4 wire 415 Volt ac 50 Hz complete duly painted, powder coated complete with locking arrangement, earthing terminals with suitable rating aluminium strips for incoming/outgoing MCCB's including and Mounting measuring instrument such as Volt meter, Ammeter (0-400 Amps), Selector switchs, CT's -03 Set, Phase indicator lamps with holder, toggle switches and backelite fuse cut outs etc including incoming and outgoing cables connections with suitable cable glands and end termination including grouting of feeder pillar box 60 cm above ground level by providing 105 cm long angle iron size 50x50x6mm welded on all four corner embedded in PCC (1:2:4) using 20mm graded upto 45cm complete all as specified and directed by the Engr-in-charge. |
| 66 | LT Panel shall be consisting the following:- (a) 4 Nos electrolytic aluminium bus bars high conductivity aluminium alloy proper insulated of 1 ½ times of the incoming capacity with provision of extension and mounting on porcelain support (b) MCCB FP 250 amps, 25 KA , 415 volts, 50Hz, Ics=100%Icu (Adjustable type) = 01 No (Incoming)(c) MCCB FP 63 Amps, 10 KA, 415 Volts, 50 Hz (thermal magnetic release and overload type) = 08 Nos (Outgoing)(d) Required no. of holes in bottom for inlet and outlet cable with suitable size of cable gland(e) Electric connection between MCCB and Busbar shall be done with aluminium strip links duly colour coded.(f) Digital Panel mounted Amp meter 96 mm square type complete with selector switch complete with suitable size of CT's - 01 Set(g) Digital Panel mounted Volt meter 96 mm square type complete with selector switch - 01 NosNote: Drawing shall be approved by GE before placing the order. |
| 67 | Excavation in trenches in soft/disintegrated soil not exc 1.5 m wide and not exceeding 1.5m in depth for laying UG cable/foundation etc complete all as specified and directed. |
| 68 | Returning filling in soft/disintegrated soil including spreading levelling watering and well ramming in layers n.exc 25cm each layer complete all as specified and directed. |
| 69 | Supply and laying dry river clean sand filling for cushioning in trenches around under ground cable complete all as specified and directed. |
| 70 | M&L for laying well burnt brick, old size sub class 'B' bricks in trenches across the cable length as protection of under ground cable complete all as specified and directed. |
| 71 | S&F GI tubing light grade ISI marked of 80 mm bore dia complete all as specified and directed. |
| 72 | Removal of excavated surplus soft/disintegrated soil to a distance not exc 50 mtr and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified and directed. Please Enable Macros to View BoQ information |