| 1 | Taking down carefully aluminium / copper point wiring any type for one light , fan, socket power point controlled by one switch complete including fitting / fixtures such as switches, ceiling roses, holder, socket etc; and making good disturbed surfaces of walls, ceilings etc |
| 2 | Material and labour for point wiring for one light/fan/exhaust fan controlled by one way switch with 1.5 Sqmm PVC insulated unsheathed two single core multi-stranded copper conductor (FRLS) cable, 1100 Volts grade drawn through and including rigid non metallic PVC concealed conduit (medium grade) of suitable dia along with 1.5 sqmm continuous PVC insulated unsheathed single core multi-stranded copper conductor (FRLS) cable for earth continuity wire, connected to earth dolly and in including modular pressed steel sunken boxes of required size with modular cover plate with frame for mounting modular switches, sockets, fan regulators etc including testing on completion complete including cutting chases for concealed conduit pinning in making good to disturbed surface and pointing in using cement mortar 1:3 all as specified and as directed for the following. |
| 3 | One light/fan point controled by one 5/6 Amp piano type switch |
| 4 | One 3 pin socket outlet 5 Amps on same board. |
| 5 | One 3 pin socket outlet 5 Amps on indpendent board |
| 6 | All as per item No 2 here in before but point wiring with 2.5 sqmm FR multi stranded copper conductor cable for main circuit and 2.5 sqmm cable as earth continuity conductor for one 15 Amp socket out let controlled by one 15 Amp switch on independat board, complete all as specified and directed. |
| 7 | Material and labour for point wiring for one light/fan/exhaust fan controlled by one way switch with 1.5 Sqmm PVC insulated unsheathed two single core multi-stranded copper conductor (FRLS) cable, 1100 Volts grade drawn through and including PVC casing and capping of size 30/32 mm fixed to wall ceiling including PVC closed recessed boxes ISI marked with 3.00 mm thick plastic laminated sheet top cover or cover plate of modular complete for mounting of switches, sockets etc incl 1.50 sqmm (nominal area) PVC insulated and sheathed multistranded copper conductor cable FRLSH 1100 volts grade single core earth continuity conductor connected to common earth dolly all as directed and specified for the followings. |
| 8 | One light /fan point controled by one 5/6 Amp piano type switch |
| 9 | One 3 pin socket outlet 5 Amps on same board. |
| 10 | One 3 pin socket outlet 5 Amps on indpendent board |
| 11 | All as per item No 4 here in before but point wiring with 2.5 sqmm FR multi stranded copper conductor cable for main circuit and 2.5 sqmm cable as earth continuity conductor for one 15 Amp socket out let controlled by one 15 Amp switch on independat board, complete all as specified and directed. |
| 12 | S&F in replacement of switch piano (flush button type) single pole, one way, 5 Amps complete all as specified and directed. |
| 13 | S&F in replacement of switch socket combination 2 in one, 3 pin , 5/6 Amps, 240 Volts flush type,complete all as specified and directed. |
| 14 | S&F in replacement of switch socket combination 2 in one , 3 pin, 5/6/16 Amps flush type complete all as specified and directed. |
| 15 | S&F in replacement of socket out let 2 in 1, 3 pin 5 Amps flush type complete all as specified and directed. |
| 16 | S&F in replacement of modular switch single pole one way 6 Amps 1 module complete all as specified and directed. |
| 17 | S&F in replacement of modular socket 6 A-2/3 pin combined 2 module complete all as specified and directed. |
| 18 | S&F in replacement of modular switch single pole one way 16 Amps 1 module complete all as specified and directed. |
| 19 | S&F in replacement of modular socket 6 A/16 amp -2/3 pin combined 2 module complete all as specified and directed. |
| 20 | S&F in replacement of ceiling rose polycarbonate type three terminals complete all as specified and directed. |
| 21 | S&F in replacement of step type electronic fan regulator 120 watt single pole 240 Volts complete all as specified |
| 22 | S&F in replacement of modular fan regulator, electronic step type heavy duty modular 2 module 230 volts, 120 watt complete all as specified and as directed. |
| 23 | Supply and fix in replacement Lamp holder PVC case body of Bakelite with back plate suitable for batten fittings,all as specified. |
| 24 | Supply and fix LED bulb 12 watts, 240Volts,50Hz pin type and including removing old unserviceable item complete all as specified and directed. |
| 25 | S&F in replecement of Ultra slim LED light to new 36W, 6500 K LED recess mounted bakelite panel 2 x 2 luminaire suitable for surface/grid ceiling for low ceiling applications complete with tube, driver and connecting cable including making electric connection to ceiling rose or connector including taking down old unserviceable luminaire, complete all as specified and as directed. |
| 26 | Supply & fix LED Battens surface mounting General purpose in Extruded Aluminium housing with wattage of 20 watt 4 feet light fitting and removing old unserviceable fitting complete all as specified and directed. |
| 27 | S & F in replacement of LED light fitting 1x9W/1X10W bulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size |
| 28 | S&F in replecement of plug top, AC 230 Volts, 5/6 Amps complete all as specified and directed. |
| 29 | S&F in replecement of plug top, AC 230 Volts, 16 Amps complete all as specified and directed. |
| 30 | S&F in replecement of PVC conduit medium grade with fittings, ISI marked, 25 mm size complete all as specified and directed. |
| 31 | S&F in replecement of PVC casing & capping with fittings, ISI marked, 25X16 mm size complete all as specified and directed. |
| 32 | S&F in replecement of PVC switch boards, closed recessed suitable for surfaces, sizes 4 X 4 (Inches) complete all as specified and as directed. |
| 33 | S&F in replecement of PVC switch boards, closed recessed suitable for surfaces, sizes 4 X 7 (Inches) complete all as specified and as directed. |
| 34 | S&F in replecement of PVC switch boards, closed recessed suitable for surfaces, sizes 8 X 6 (Inches) complete all as specified and as directed. |
| 35 | S&F in replecement of sub main wiring with two run of single core PVC insulated FRLSH stranded copper conductor cable of size 6 Sq mm and one run of 6 Sq mm PVC insulated FRLSH copper conductor cable as earth continuity conductor drawn in and including PVC casing and caping/PVC rigid conduit 20mm dia with necessary accessories complete all as directed. Note : 2 Runs of 6 sqmm cable and one run of 6.00 sqmm earth wire with PVC casing and caping shall be measured as one unit. |
| 36 | S&F in replecement of sub main wiring with two run of single core PVC insulated FRLSH stranded copper conductor cable of size 4 Sq mm and one run of 4 Sq mm PVC insulated FRLSH copper conductor cable as earth continuity conductor drawn in and including PVC casing and caping/PVC rigid conduit 20mm dia with necessary accessories complete all as directed. Note : 2 Runs of 4 sqmm cable and one run of 4.00 sqmm earth wire with PVC rigid conduit shall be measured as one unit. |
| 37 | S&F in replecement of 1100 volts grade heavy duty cable PVC insulated aliminium conductor served with inner sheathing of PVC sheathed with stranded conductor 10 sqmm twin core cable flat or circular, complete all as specified and directed. |
| 38 | S&F in replecement of Sheet metal enclosure IP-43 double door for DBs(where MCBs are reqd) SPN 240 V, for 4 ways, complete all as specified. |
| 39 | All as per item no 35 above but SPN 8 ways 240 volts complete all as specified and directed. |
| 40 | All as per item no 35 above but SPN 12 ways 240 volts complete all as specified and directed. |
| 41 | S&F in replecement of MCB SP 6 to 32 Amp, 240 volts complete all as specified. |
| 42 | S&F in replecement of MCB SPN 32-40 Amp, 240 volts 50Hz AC supply, complete all specified. |
| 43 | S&F in replecement of MCCB 63 Amp,4 pole, 16KA 415 volts 50Hz, AC supply, complete all specified. |
| 44 | S&F in replecement of sheet metal enclosure for multi phase out going suitable for mounting 63 Amps FP MCCBs. Vertical distribution board 4 ways mounting as incommer with 200 Amp rared bus bar,IP- 42 Protection ,double door conceled/ wall mounting suitable for mounting MCBs/Isolators.all as specified and as directed. |
| 45 | Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) and supplies as provided by manufacturer including making connection with three core 1.5sqmm flexible copper cable upto ceiling rose complete all as directed. |
| 46 | S&F of Exhaust Fan plastic body, 200mm(8\\") sweep, single phase, 230 volts 50 Hz AC,1200 RPM, energy saving, heavy duty totally enclosed, heavy duty motor with die-cast aluminiun rotor mounted on two ball bearings complete with louvers and shutters including cutting hole for fixing exhaust fan to wall and making good the disturbed surfaces (including making holes in wall,plastering, necessary brickwork and distempering) to match with the existing specification, connecting electrically using 3 core 0.75 Sq mm PVC insulated flexible copper conductor cable over all sheathed all as required at site and as directed.Make: Havells/Bajaj/Crompton |
| 47 | S&F of Exhaust Fan plastic body, 250/300mm(10&12\\") sweep, single phase, 230 volts 50 Hz AC,1200 RPM, energy saving, heavy duty totally enclosed, heavy duty motor with die-cast aluminiun rotor mounted on two ball bearings complete with louvers and shutters including cutting hole for fixing exhaust fan to wall and making good the disturbed surfaces (including making holes in wall,plastering, necessary brickwork and distempering) to match with the existing specification, connecting electrically using 3 core 0.75 Sq mm PVC insulated flexible copper conductor cable over all sheathed all as required at site and as directed.Make: Havells/Bajaj/Crompton |
| 48 | Deduction to be made from BOQ for schedule of credit (Sch 'A' Part - II) Amount of ₹ 36786.00 during AOCNote:- Tenderers shall not quote for this Schedule Please Enable Macros to View BoQ information |