| 1 | Crack Sealing/Filling using epoxy mortar: Base and hardener of the high strength repair mortar . Epoxy putty shall be mixed using the slow speed heavy duty mixing machine to obtain a uniform mix. The mixed materials shall be placed all along the prepared \\"V\\" groove and finished smoothly using the putty blade/trowel within 30 minutes by using the divers. The finished surface shall be allowed for curing minimum of 24 hours to attain the strength. The item includes the cost of hire charges of all equipment, tools and plants and all labour charges etc., complete. |
| 2 | Stapling as per specifications and standards defined in IRC SP:83-2018 |
| 3 | Cross- Stitching as per specifications and standards defined in IRC SP:83-2018 |
| 4 | Dressing of side shoulder/Scrapping the road side shoulder by Mechanical means(By JCB/DOUZER) including excavation of raised side shoulders upto 15cm depth including remooving/cutting bushes, grass and dressing shoulder to desired camber and disposing of excavated stuff up to road boundary etc complete. as directed by Engineer In Charge. (Item No. 8.23) |
| 5 | Trimming of grass, shurbs and weeds from the shoulders/berms and disposing off the same to suitable locations etc. complete |
| 6 | Dismantling of cement concrete pavement by mechanical means using pneumatic tools, breaking to pieces not exceeding 0.02 cum in volume and stock piling at designated locations and disposal of dismantled materials up to a lead of 1000 metres, stacking serviceable and unserviceable materials separately etc. complete. |
| 7 | Removing lime or lean cement concrete including stacking the spoils as directed with all leads, lifts etc, complete. |
| 8 | Construction of dry lean cement concrete Sub-base over a prepared sub-grade with coarse and fine aggregate(natural sand/VSI grade finely washed crushed sand) conforming to IS: 383, the size of coarse aggregate not exceeding 25mm, , cement content not to be less than 150kg/cum, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days, mixed in a batching plant/Weigh batch mixer, transported to site with all leads and lifts, laid with a paver with electronic sensor/by suitable means as approved by Engineer-in-charge, compacting with vibratory roller, finishing, curing and including preparation of sub-grade surface if required etc. complete. with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/concrete Batch mix plant(Pan mixer) etc. complete |
| 9 | Providing and laying 125 micron Low Density Polyethylene(LDPE) sheet confirming to IS 3395 : 1997 below concrete pavement including all materials and labour complete. |
| 10 | Providing and laying in-situ M40 Grade unreinforced plain cement concrete pavement with max 20% fly Ash(Fly-ash upto 20% by weight of Cement) over a prepared sub base with 43 grade cement, coarse and fine aggregate(natural sand/VSI grade finely washed crushed sand) conforming to IS 383, using fine and coarse aggregates combined gradation as per Table 600-3 of MORTH Specification 2013, mixed in a batching and mixing plant/non tilting mixer and Weigh batcher as per approved mix design, admixtures, transporting to site, spreading, laying with approved make paver, compacted and finished in a continuous operation, finishing to lines and grades as directed by Engineer-in-charge and curing by curing compound/by providing cement vata in cement Mortar 1:8 @0.6m X 0.6m centre to centre, admeasuring 80mm at bottom and 40mm at top with depth of 75mm and maintaining the same throughout curing period by any other method approved by Engineer-in-charge |
| 11 | Providing and fixing in position TMT FE 500, tie bars precoated with anticorrosive epoxy paint of 12mm dia. 70cms.long and at 30.00cm. C/C and wherever directed including handling, straightening wrapping with paper of approved quality for half length, necessary cutting, handling, straightening, supported by assembly of TMT FE 500, chairs with proper alignment etc. complete. |
| 12 | Providing and fixing in position TMT FE 500, 32mm dia dowel bars precoated with anticorrosive epoxy paint of required Dia. 60cms. Long and at 30.00cm. C/C and wherever directed including handling, straightening, necessary cutting supported by TMT FE 500, chairs with proper alignment by using properly designed assembly of Bulkheads lubricating half length with bituminous paint as directed etc. complete. (Item No. 5.14) |
| 13 | Cutting transverse contraction joints 3 to 4mm wide and depth 60mm. .in concrete slab using concrete cutting machine with diamond studded saw within 48 hours of casting of bay/slab etc. complete including subsequent widening of the groove 8 to 10mm. wide at top having depth of 15mm. as directed by Engineer incharge |
| 14 | Providing to contraction joints polysuphide sealent(Pouring grade) confirming to BS : 5212-1989 into sawed groove widened at top for sealent reservoir of specified size and shape as per detailed drawing including fixing Polyethylene foam backer rod of required diameter(appraox. 25% larger than the initial 3mm.to 4mm. joint) overlaid with bond breaking tape as per detailed drawing. Item includes cleaning the joints with water jet/air compressor and allowing joint to become thoroughly dry before sealent is applied and applying primer.(A) Contraction and longitudinal joints(15mm. deep x 8mm.wide) |
| 15 | Providing and Laying of 2 or more sets (6 Nos. each set) Dual Ribs Pattern Rumble Markings on roads with vehicular speeds of more than 50 Km/hr laid as per the spacing recommended for each set under Table 11.1 and Fig. 11.2 of IRC 35:2015 using Plastirib 2K, or equivalent 2 component cold plastic profiled material. Each Dual Rib pattern rumble marking shall have width of 500 mm. Each dual rib pattern rumble marking shall have 2 ribs each of Width of 100 mm and height 20 mm. Gap between two ribs shall be 300 mm. Each rumble marking shall be made complete with drop on Soild Plus reflective glass beads @ 300 gm / One Square Metre spread throughout the surface of marking. The finished surface to be levelled, uniform and free from streaks and holes, including surface cleaning and cost of all materials etc. complete. |
| 16 | Providing to contraction joints polysuphide sealent(Pouring grade) confirming to BS : 5212-1989 into sawed groove widened at top for sealent reservoir of specified size and shape as per detailed drawing including fixing Polyethylene foam backer rod of required diameter(appraox. 25% larger than the initial 3mm.to 4mm. joint) overlaid with bond breaking tape as per detailed drawing. Item includes cleaning the joints with water jet/air compressor and allowing joint to become thoroughly dry before sealent is applied and applying primer.(A) Contraction and longitudinal joints(15mm. deep x 8mm.wide) (Item No. 5.18). |
| 17 | Providing and Laying hot applied thermoplastic road marking strip on Bituminous Surface of specified shade/colour of 2.5mm thick including 1.5 Refractive index reflectorizing glass beads @ 250gm/sqm .Thickness of 2.5mm is exclusive of surface applied glass beads as per IRC 35:2015. Initial Dry reflectivity RL shall be > 250 mcd/sqm/lux measured in the initial 7 days and sustained reflectivity RL of 100 mcd/sqm/lux and Qd of 100 mcd/sqm/lux measured at the end of 2 years by means of a Standard Reflectometer of Zehntner, Easylux, Delta make capable of measuring RL & QD both according to IRC 35:2015 clause 15.5. The finished surface to be level, uniform, and free from streaks and holes complete as per direction of Engineer-in-charge and in accordance with applicable specifications.(Refer MORTH Clause 803 for technical Specification and Performance for IRC 35:2015). (Item No. 6.12a) |
| 18 | Supplying and Fixing of Molded Shank Raised Pavement Markers/Cat's Eye made of polycarbonate and ABS moulded body and reflective panels with micro prismatic lens capable of providing total internal reflection of the light entering the lens face and shall support a load of 16000kg tested in accordance to ASTM D 4280 Type H and complying to Specifications of Category A of MORTH Circular No RW/NH/33023/10-97 DO III Dt 11.06. 1997. The height, width and length shall not exceed 50mm, 100mm and 102 +/-2mm and with minimum reflective area of 13 Sqcm on each side and the slope to the base shall be 35 +/-5 degree. The strength of detachment of the integrated cylindrical shanks, (of diameter not less than 19 +/-2mm and height not less than 30+/-2mm) from the body is to be a minimum value of 500 Kg. Fixing will be by drilling holes on the road for the shanks to go inside, without nails and using epoxy resin based adhesive as per manufacturer's recommendation and complete as directed by the engineer.The contractor shall submit a two year warranty for satisfactory field performance including stipulated retro-reflectance of the reflecting panel, to the Engineer. |
| 19 | A) Excavation for foundation in earth, soils of all types, sand, gravel, soft murum including shoring and strutting, dewatering as necessary and disposing off excavated stuff as directed etc. complete. (By Mechanical Means) |
| 20 | Providing and laying in situ / ready mix / ready mix M10 cement concrete of trap/ granite/ quartzite/ gneiss metal in foundation including necessary centering, formwork, bailing out water, compacting and curing etc. complete. (with fully automatic micro processor based PLC with SCADA enabled with reversible drum type mixer/ concrete batch mix plant (pan mixer) with natural /artifical sand) |
| 21 | Providing and laying plain in situ / ready mix M-35 cement concrete of trap /granite /quartzite /gneiss /crushed stone metal mechanically mixed, placed in foundation and compacted by vibration including necessary bailing out water, curing curing concrete batch mix plant / pan mixer with fine agreegates of required specifications ( VSI sand finely washed etc ) (excluding dewatering by pump) for 14 days RCC Grade.With concrete Mixe |
| 22 | Providing, cutting, bending, hooking, tying and laying in position TMT FE 500 steel bars for reinforcement for all RCC works as per detailed drawings etc. complete |
| 23 | Providing and laying weep holes of 100 mm diameter PVC pipes as per drawing for abutment returns, return walls etc. Complete. |
| 24 | Providing and laying of filter media with granular materials/ stone crushed aggregates satisfying the requirements laid down in clause 2504.2.2 of MoRTH specifications to a thickness of not less than 600 mm with smaller size towards the soil and bigger size towards the wall and provided over the entire surface behind abutment, wing wall and return wall to the full height compacted to a firm condition as per drawing and technical specifications etc. complete |
| 25 | Supplying, installing, testing and commissioning solar street light pole comprising of 12W x 2 nos. LED fittings, 12V min. 100Ah maintenance free lithium battery, min. 120Wp SPV module, MS powder coated battery box weather proof, mounted on 75/80 mm dia. B-Grade GI pole of 6 m. height along with brackets, foundation, earthling and necessary accessories complete. Specification no. ESDSOL-STL Please Enable Macros to View BoQ information |