| 1 | Item Rate BoQ BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority: GE KOTA Name of Work: REPAIR/MAINTENANCE TO SUMMER APPLIANCES, GEYSER, SOLAR WATER HEATERS AND CONNECTED ITEMS INSTALLED AT MIL STN KOTA Contract No: GE/K- OF 2026-2027 Bidder Name : SCHEDULE 'A' (PRICE SCHEDULE)(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only ) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # Srl.No. Item Description Item Code / Make Approx Quantity Units Estimated Rate Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency RATE In Figures To be entered by the Bidder Rs. P Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT Without Taxes TOTAL AMOUNT with Taxes (in Rs.) TOTAL AMOUNT In Words |
| 2 | REPAIR/ MAINTENANCE TO SUMMER APPLIANCES |
| 3 | M & L for taking down & refixing including transportation of window type AC upto 2 Ton capacity from site to civil workshop for repair to corroded body by replacing with 22 SWG MS sheet for side/top and 3mm thick MS plate in bottom of AC & including renewal of unserviceable spares and painting with anti corrosive paint of existing colour over and including a coat of suitable primer and return to MES store yard complete all as specified and directed. |
| 4 | M & L for taking down & refixing including transportation of split type AC indoor/outdoor unit upto 2 Ton capacity from site to civil/local workshop for repair to corroded body by replacing with 22 SWG MS sheet for side/top and bottom of AC & including renewal of unserviceable spares and painting with anti corrosive paint of existing colour over and including a coat of suitable primer and return to MES store yard complete all as specified and directed. |
| 5 | Attending complaints as on required of any nature for defective A/C of various capacity and make split /window type and rectification of defects & including necessary dismantling, taking down if required and taking out for repairing and refixing at site, replacing spares as required (spares parts shall be measured and paid separately), however small pieces of wire terminals, soldering/crimping required at site for proper functioning of the equipment shall deemed to be included in the quoted rate under this item complete all as specified and directed.Note : All spare parts for renewal/ fixing shall be measured and paid separately as supply only or supply & fixing under appropriate items of BOQ. |
| 6 | Supply only in renewal of starting capacitor 100/120 MFD suitable for window/split type AC complete all as specified and directed. |
| 7 | Supply only in renewal of running capacitor MFD/45+2.5 MFD/ 50+4.5 MFD / 60+6 MFD suitable for window/split type AC complete all as specified and directed. |
| 8 | Supply only in renewal of running capacitor 2.5/3/4/6 MFD for fan motor of window type/Split AC complete all as specified and directed. |
| 9 | Supply only in renewal of fan motor 1/5 HP long shaft suitable for window type AC of any capacity, as per sample complete all as specified and directed.MAKE: Universal / Sarada / Tibcon /Keltron |
| 10 | Supply only in renewal of fan motor 1/5 HP suitable for out door unit of split type AC 1.5 / 2.0 Ton capacity as per sample complete all as specified and directed.Make: Universal/Sarada/Tibcon/Keltron /American Universal/GE Motors. |
| 11 | Supply only in renewal of fan blade suitable for out door unit of split type AC 1.5/2.0 Ton capacity complete all as specified and directed. Make: Universal/Sarada/Tibcon/Keltron /American Universal/GE Motors. |
| 12 | Supply only in renewal of starting relay pin type for window / split type ACs as per existing specification complete all as specified and directed.Make - Renutral/ Indfos/ Annapurna or equivalent as approved by GE. |
| 13 | Supply only in renewal of printed circuit board (PCB) suitable for split type AC 1.5/2.0 Ton capacity of existing specification and make complete all as specified and directed. Make : Carrier/Amtrex/Fedder Lloyed/LG/Voltas/Bluestar or as per sample. |
| 14 | Supply only in renewal of temperature digital display sensor suitable for split type AC 1.5/2.0 Ton capacity of existing specification and make complete all as specified and directed. Make : Carrier/Amtrex/Fedder Lloyed/LG/Voltas/Bluestar or as per sample. |
| 15 | Supply and fixing in renewal of remote for A/C split type 1.5/2.0 Ton capacity of existing specification and make complete all as specified and directed. Make : Carrier/Amtrex/Fedder Lloyed/LG/Voltas/Bluestar or as per sample. |
| 16 | Dismantling the unserviceable/damaged insulation and supply and fix nitrile rubber insulation of size 3/8 & 5/8\\" for suction and liquid refrigerant line for split type AC complete all as directed. Make-A-flex,Totaline. |
| 17 | Supply and fixing in renewal of copper tube 1/4\\" for window ACs of any capacity complete all as specified and directed.Make - Totaline/Carrier. |
| 18 | Supply and fixing in renewal of copper tube 1/2\\" complete all as specified and directed. Make - Totaline/Carrier. |
| 19 | Supply only in renewal of condensing coil with copper tube and aluminium fins of capacity 1.5/2.00 TR suitable for split AC complete all as specified and directed. Make : LG/Carrier /Voltas/Samsung or equivalent make as approved by GE. |
| 20 | Supply only in renewal of cooling coil with copper tube for indoor unit of split AC capacity 1.5/2.00 TR complete all as specified and directed. Make : LG/Carrier /Voltas/Samsung or equivalent make as approved by GE. |
| 21 | Supply and fixing in renewal of fiber body suitable for indoor unit of split AC 1.5/2.0 TR complete all as specified and directed. Make : LG/Carrier /Voltas/Samsung or equivalent make as approved by GE. |
| 22 | Supply and fixing in renewal of factory made stand for outer unit of split AC as per existing specification and make complete all as directed. |
| 23 | M&L for electrically disconnecting of outdoor unit of split AC & including taking out from wall / stand after pumping down gas, cleaning/washing of chocked condensing fins and tubes with water and solvent materials by using mechinical pressure after cleaning and servicing refixing of unit, mechanically leak testing including filling of nitrogen gas for pressure testing, finding leak, vacuumising the gas and bracing of leaked copper pipes and filling the suitable refrigerant gas after complete testing, connecting the cables and testing for functioning complete all as specified and directed. |
| 24 | M&L for electrically disconnecting of window type AC and taking out from wall, cleaning /washing of choked condensing fins, evaporator coil and tubes with water and solvent materials by using mechinical pressure, renewal of unserviceable air filter after cleaning and servicing refixing the window AC, mechanically leak testing, including filling of nitrogen gas for pressure testing, finding leak, vacuumising the gas and bracing of leaked copper pipes and filling the suitable refrigerant gas after complete testing, connecting the cables and testing for functioning complete all as specified and directed. |
| 25 | Taking down unserviceable hermatically sealed compressor unit of window/split type ACs of 1.5/2.0 TR capacity and replace with new sealed compressor unit in exchange of the existing unserviceable sealed compressor unit with and including initial charging of gas and oil complete all as specified and directed. Make : Kirloskar/Shriram/Copeland/Godrej/LG/Voltas. |
| 26 | Taking down the existing split type AC of any size & including all accessories and closing the opening of wall with brick/stone masonary work in cement mortar 1:4 and plastering with cement 1:4 including white wash /distempering to match with surrounding & making good the disturbed surfaces to match with existing surface complete all as specified and directed. |
| 27 | Fixing only already removed window/split type AC & including all accessories, making suitable size opening in existing wall as suitable for fixing of AC, including making good the disturbed surfaces to match with existing surface complete all as specified and directed. |
| 28 | Supply and filling refrigerant gas R-22/R- 32/R-410/R-134/R-600 for charging of gas in compressors of existing AC's/Refrigerator/water cooler/Deep freezer complete all as directed.Note ;- (i) Empty /filled cylinder shall be responsability of contractor and he shall be liable for all risk against same deemed to be included in the quoted rate.(ii) Empty gas Cylinders shall be returned to contractor after use. |
| 29 | M & L for repairs to voltage stabilizer of any make/model & including rewinding of main transformer, renewal of sensing transformer, connector, up to 30 Amps power relay and 3 core multistranded PVC insulated flexible copper conductor cable, voltage stabilizer of capacity upto 5 KVA complete all as specified and directed. |
| 30 | Attending complaints as on required basis of any nature for defective water coolers, refrigerator and deep freezer of various capacity and make and rectification of defects including necessary dismantling and taking out for repairing and refixing at site, replacing spares as required (spares shall be measured and paid separately), however small pieces of wire terminals, soldering / crimping required on site for proper functioning of the equipment will be deemed to be included in the quoted rate under this item. Note : All unserviceable spare parts for renewal/ fixing shall be measured and paid separately as supply only or supply & fixing under appropriate items of BOQ. |
| 31 | M&L for transportation of water cooler of any capacity form site to local workshop for repair to body by tinkering with 22 SWG MS sheet ,spray painting of complete water cooler with two coat of synthetic enamel paint over a coat of zinc primer on the repaired portion of existing colours, including supply and fix top cover beading, hinges, broken legs and transportation of water cooler back to AGE E&M yard capacity 40/80 ltr /60/120 ltr / 40/40ltr and testing commissioning complete.Note : All unserviceable spare parts for renewal/ fixing shall be measured and paid separately as supply only under appropriate items of BOQ. |
| 32 | Supply only in renewal of Fan motor 1/3 HP with blade complete all as directed.Make: AUE/Shreeram or equivalent make as approved by GE. |
| 33 | Supply only in renewal of relay for 1/3 HP compressor complete all as directed.Make: HI- Tech/Ranitrol. |
| 34 | Supply only in renewal of Over load proctector relay for 1/3 HP compressor complete all as directed.Make: HI- Tech/Ranitrol. |
| 35 | Supply only in renewal of Thermostatic switch for water cooler of any capacity complete all as directed.Make: Indofoss/Ranitrol. |
| 36 | Supply only in renewal of Starting Capacitor 40-60 MFD complete all as directed.Make: Keltron/Polycap. |
| 37 | Supply only in renewal of Running Capacitor 10 MFD complete all as directed.Make: Keltron/Polycap. |
| 38 | Supply only in renewal of 15mm bore statinless steel Push button Tap for water cooler as per sample complete all as directed.Make :- Jaison/Prayag/Sangam or equivalent make approved by GE. |
| 39 | Supply only in renewal of 15mm bore ball/float valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe and fixed (minimum weight 15mm-142gms) suitable for water coolers complete all as directed. Make:- Prayag/Sangam or equivalent make approved by GE. |
| 40 | Supply only in renewal of Plug top 15/16 Amps complete all as directed. Make :- Kinjal/Anchor/Havells or equivalent make approved by GE. |
| 41 | Supply only in renewal of Plug top 5/6 Amps complete all as directed. Make :- Kinjal/Anchor/Havells or equivalent make approved by GE. |
| 42 | Supply only in renewal of Cooling coil unit of Aluminium for freezer unit upto 310 Litres complete all as directed. Make :- Suitable for Godrej/ Whirlpool/ LG/ Samsung make refigerator. |
| 43 | Supply only in renewal of Relay suitable for refrigerator of 1/6 or 1/8 HP compressor complete all as directed. Make :- Hi tech / Ranitrol. |
| 44 | Supply only in renewal of Capillary tube for refrigerator any capacity complete all as directed. Make :- Suitable for Godrej/ Whirlpool/ LG/ Samsung make refigerator. |
| 45 | Supply only in renewal of Door lining (magnetic) for refrigerator 220/310 Litres capacity complete all as directed. Make :- Suitable for Godrej/ Whirlpool/ LG/ Samsung make refigerator. |
| 46 | Supply only in renewal of Over load protector relay suitable for refrigerator complete all as directed. Make:- Hi tech/ Ranitrol. |
| 47 | Supply only in renewal of Cabin lamp for refrigerator as per sample complete all as directed. Make :- Philips/ Pigma/ Orsam. |
| 48 | Supply only in renewal of Thermostatic switch for Refrigerator complete all as directed. Make: Indofoss/Whirlpool (Auto defrosting type). |
| 49 | Taking down unserviceable compressor unit of water coolers of 40/80 ltr capacity and supply and fix with new sealed compressor & including intial charging of gas and oil complete all as specified and directed. Make : Kirloskar/Shriram/Copeland/Godrej/LG/Voltas. |
| 50 | Taking down unserviceable compressor unit of water coolers of 60/120 ltr capacity and supply and fix with new sealed compressor & including intial charging of gas and oil complete all as specified and directed. Make : Kirloskar/Shriram/Copeland/Godrej/LG/Voltas. |
| 51 | Supply and fixing sealed compressor 1/6 HP / 1/8 HP suitable for refrigerators & including taking down unserviceable existing compressor complete all as specified and directed. Make : Kirloskar/Shriram/Copeland/Godrej/LG/Voltas. |
| 52 | S&F of sub main wiring with two runs of single core PVC insulated and unsheathed FRLSH multistranded copper conductor cable of size 4 Sqmm LT, 1100 volts grade, drawn through and including 20 mm dia PVC non metallic surface conduit with accessories such as socket, elbow, junction box, bell mouth, reducer, bend and flexible conduit etc. and fittings and one run of 4 sqmm single core multistranded FRLSH copper conductor cable green colour as earth continuity conductor and including taking down old unserviceable wiring complete all as specified & as directed.Note :- Two runs of cable one run of earth wire and one run of PVC non metallic conduit of 20mm dia shall be measured as one run length. Cable required for connection to DBs shall deemed to be included and shall not be measured separately. Earth wire shall run inside the PVC conduit. |
| 53 | Supply only in renewal of Relay for 1/3 HP compressor (1208) complete all as directed.Make: HI- Tech/Ranitrol. |
| 54 | Supply only in renewal of Over load proctector relay for 1/3 HP compressor complete all as directed.Make: HI- Tech/Ranitrol. |
| 55 | Taking down unserviceable compressor unit of deep freezer upto 310 ltr capacity and supply and fix with new sealed compressor of capacity 1/3 HP unit of suitable capacity complete all as directed.Make:- Kirloskar/Blue star /Copeland. |
| 56 | Material and labour for spray painting of refrigerator / water cooler externally with two coats of Duco paint of approved shade after necessary preparation of surfces & including denting, etc. complete all as specified and directed for the following items: Refrigerator of capacity 165 to 310 Liters. |
| 57 | Water Cooler of capacity upto 120 Liters. |
| 58 | Dismantling, opening and including rewinding the desert cooler fan motor of capacity 1/10 HP or 1/8 HP single phase AC 50 Hz with super enamelled copper wire of existing gauge/ size & including renewal of bush, shaft, packing gasket, nuts, bolts and washers, complete all as specified and directed. |
| 59 | Supply and fix in renewal of 20mm thick wool pad set (set of 3) & including wire mesh suitable for 18\\"/20\\" desert cooler complete all as specified and directed. |
| 60 | S&F in renewal of set of fan blades various type for derest coolers complete all as specified and directed. |
| 61 | Supply and fix in renewal of submersible 1.8m head, 5 ltr per minutes water discharge, 230 Volt, AC, Desert Cooler spray pump suitable for 18\\"/20\\" desert cooler complete all as specified and directed. |
| 62 | S&F in renewal of 3 core flexible FRLSH cable of multistranded copper conductor 2.5 sqmm confirming to latest IS, complete all as specified and directed. |
| 63 | S&F in renewal of regulating switch three speed 5 Amps, SP, 230 volts complete all as specified and directed. |
| 64 | S&F in renewal of PVC flexible pipe 15mm bore of superior quality complete all as specified and directed. |
| 65 | S&F in renewal of PVC water distributor 3 way assembly of size 15mm & including fixing at top of cooler by means of screw/ bolts /nuts, complete all as specified and directed. |
| 66 | M&L for preparation of steel surfaces of desert cooler (inner/ outer) & including spray painting with synthetic enamel paint first quality over & incl a coat of red oxide primer, complete all as specified and directed. |
| 67 | M & L for cutting of unserviceable rusted base from Water coolers of any make and S&F new base fabricated out of MS sheet 16 gauge on existing water cooler & including drilling and welding and applying two coats of synthetic enameled paint over one coat of red oxide primer, complete all as specified and directed. |
| 68 | S&F in renewal of side panel made out of PBI sheet minimum 1mm thick suitable for 18''/20'' desert cooler and applying two coats of synthetic enameled paint over one coat of red oxide primer, complete all as specified and directed. |
| 69 | Dismantling of unserviceable PVC/iron grill of desert cooler and Supply & fixing PVC/Iron grill suitable for 18''/20'' desert cooler including screws, nut & bolts etc, complete all as specified and directed. |
| 70 | Dismantling of unserviceable desert cooler fan motor with iron ring and supply and fixing of new fan motor copper wound, ISI marked with iron ring of existing capacity & including nuts, bolts, washers etc, complete all as specified and directed.Make :- Crompton/Khaitan/Usha/Polor. |
| 71 | S&F in renewal of sheet metal single pole and neutral enclosure with a two pin and earth plug and socket with & including one single pole MCB, 20 Amp, AC, 230 volts, complete all as specified and directed. |
| 72 | M & L for disconnecting water cooler from existing position, drain out complete storage water and cleaning descaling etc., including repair of leakage, clean the surface of water cooler and refixing in original position, complete all as specified and directed. |
| 73 | S&F eveporate air cooler with frame and body made of 20/22 gauge iron having 80 Ltrs water storage capacity and three numbers honeycomb pads with thickness of 50mm (desert cooler) with propeller cooler fan made out of hot deep galvanised steel heavy duty single phase 230 Volts of fan sizes 450mm sweep with submersible pump of suitable size ISI markes having normal air flow capacity 4000 cum/hr with float valve of 15mm dia , stop valve of 15mm dia nut washer PVC connections of 15mm leakproof joint and all necessary arrangement to take water from GI pipe 15mm dia to air cooler complete all as specified and directed. |
| 74 | Notes applicable for all above items :- The contractor is required to carry out onsite (at the place of installation itself) repair of the summer appliances based on day to day requirement of MES during the currency of this contract. Therefore, while quoting the rates contractors should keep this factor in mind as the quoted rates shall deemed to be inclusive of the factor of onsite repair of various summer appliances. |
| 75 | GEYSERS, SOLAR WATER HEATERS AND CONNECTED ITEMS :- |
| 76 | Taking down existing water storage (Geyser) of cap 50/25 Ltrs of any make /any type from the site & including removing of pipe connection, fitting and electric connection and bringing to AGE E/M Kota store yard for dismantling and cleaning of all accessories and re-fixing the geyser at same or other location after carrying out necessary repairs etc, complete all as specified and directed. Note :S&F of spare parts/components of geyser shall be measured and paid separately under appropriate item. |
| 77 | M &L in renewal of steel inner vessal container of geysers, vertical type, 50 Ltrs capacity, complete with glass wool insulation and necessary nuts and bolts etc, complete all as specified and directed. |
| 78 | M &L in renewal of steel inner vessal container of geysers, vertical type, 25 Ltrs capacity, complete with glass wool insulation and necessary nuts and bolts etc, complete all as specified and directed. |
| 79 | M & L in renewal of outer body of verticle type geyser of capacity 25 litres, made out of 20 guage MS sheet, finished with & including stove enamelled white paint, with top and bottom plate and rings including glass wool insulation, complete all as specified and directed. |
| 80 | M & L in renewal of outer body of verticle type geyser of capacity 50 litres, made out of 20 guage MS sheet, finished with & including stove enamelled white paint, with top and bottom plate and rings including glass wool insulation, complete all as specified and directed. |
| 81 | M & L in renewal of bottom dome made out of 20 guage MS sheet finished with & including stove enamelled white paint of 50/35/25 ltrs, vertical type geysers, complete all as specified and directed. |
| 82 | M & L in renewal of wire braded PVC connection to inlet/outlet of geysers heavy duty with 2 CP brass nuts on both ends, suitable to fix with 15 mm bore stop/angle valve, 450 mm long, complete all as specified and directed. |
| 83 | M & L in renewal of pressure release valve, dead weight type, suitable for 25/35/50 ltrs capacity of geysers, complete all as specified and directed. |
| 84 | M & L in renewal of rubber gasket complete with suitable nut & bolts for geysers of 25/35/50 ltrs capacity, complete all as specified and directed. |
| 85 | S&F in renewal of syphon Assembly round/flat/triangle type with necessary gasket, brass nuts, bolts and washers, suitable for 25 ltrs capacity vertical type geysers, complete all as specified and directed. |
| 86 | S&F in renewal of Syphon Assembly round/flat/triangle type with necessary gasket, brass nuts, bolts and washers, suitable for 50 ltrs capacity vertical type geysers, complete all as specified and directed. |
| 87 | M&L for repairing of the inner container of geysers 50/35/25 ltrs by cleaning internally and brazing the leaking spot of size not more than 2.5 cm x 5.0cm and thickness not exceeding 5 mm including pressure testing of vessel, complete all as specified and directed. |
| 88 | M&L for spray painting with one coat of high gloss synthetic enamel white paint to outer surface of geysers of capacity 25/35/50 Ltrs & including writing of MES No. in block letters including fixing Do's & Dont's stickers, complete all as specified and directed. |
| 89 | M &L in renewal of non-return valve vertical type 15 mm dia screwed down high pressure, cast copper alloy, chromium plated, (ISI) marked, complete all as specified and directed. |
| 90 | S&F in renewal of stop valve, fancy type, chromium plated brass, screwed down, high pressure with crutch or butterfly handle, 15mm bore, complete all as specified and directed. |
| 91 | S&F in renewal of switch socket combination 5 and 15 Amp 230 Volts multi pin flush type, ISI marked complete all as specified and directed. |
| 92 | S&F in renewal of superior quality three pin plug top, 15 Amp capacity, ISI marked complete all as specified and directed. |
| 93 | S &F in renewal of fuse plug of geyser, made of brass, complete all as specified and directed. |
| 94 | M&L for 3 core copper conductor 2.5 Sqmm for connecting of geyser to switch board including taking down existing unseviceable complete all as specified and directed. |
| 95 | S&F in renewal of GI nipple, full threaded, 15 mm bore, complete all as specified and directed. |
| 96 | M & L in renewal of heating element of capacity 2 KW round /triangle type, ISI marked, complete all as specified and directed. |
| 97 | M&L in renewal of thermostat for geysers of any type, size as required at site, complete all as specified and directed. |
| 98 | Dismantling and opening the existing solar water heating system upto 20.0 m at site and cleaning of hot water copper tube by descaling compound, cleaning of inlet & outlet pipe, complete all as specified and directed. |
| 99 | M & L in renewal of solar geyser element of suitable capacity for upto 200 Ltrs tank complete all as specified and directed. |
| 100 | S & F of galvanised steel water tubing, medium grade, size 15 mm dia, with & including all fittings, provided for geyser air vent etc and including taking down of old u/s steel tubing complete all as specified and directed. |
| 101 | S&F sub main wiring complete with and including two Nos single core PVC insulated, unsheathed flexible conductor FR-LSH cables 4 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through and including medium mechanical stresses class PVC conduit as per IS 9537 (Part-III): 1983 of suitable nominal size as required at site dia but not less than 20 mm nominal size including all accessories and fixed on walls and 4 sqmm one No single core copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable for earthing and connected to common earth dolly complete all as specified and as directed. Note - Two runs of 4 sqmm cable, one run of 4 sqmm cable and one run of conduit shall be measured and paid as one unit length. |
| 102 | Supply and fixing in renewal of split / 'T' bolt /anchor fastner of suitable size with nut and washer, complete all as specified and directed. |
| 103 | M & L for point wiring for one 3 pin/ 5 pin 5 Amps socket outlet on independent board complete with and including single core PVC insulated, unsheathed flexible conductor FR-LSH cables 1.5 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through & including heavy mechanical stresses class and -5 temperature class PVC casing/capping of suitable size as required at site including modular/ non modular type, all accessories/ fittings/ junction boxes/ inspection cover etc. ISI marked and including providing concealed MS sheet metal sunken switch /Terminal box 1.2mm thick/PVC white in colour switch board with heat resistant for mounting switches, sockets, fan regulators etc with 3 mm thick plastic laminated sheet cover and making good disturbed surfaces suitable for fixing with 1.5 sqmm copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable as continuous earth wire connected to metallic body at one end and common earth dolly to other end complete all as specified and as directed. Note :- Cutting chases and making good to match with the adjoining surface deemed to be included in the unit quoted rate. |
| 104 | Supply and fixing in renewal of electric water heater, storage type steel body with stainless steel inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece etc. complete all as specified and directed.Note :- Old U/S geyser to be deposited at AGE E/M store yard. |
| 105 | S&F in renewal of indicator lamp of geyser both red and green, complete all as specified and directed. |
| 106 | S&F in renewal of MCB, 6 to 32 Amps, Single Pole, 240 Volt, 10 KA 'B' curve including all accessories, complete all as specified and directed. |
| 107 | M & L in renewal of heating element of capacity 2 KW round type,suitable for MARC company geyser complete all as specified and directed. |
| 108 | Attending geyser complaints after collecting from complaint cell of AGE E/M and rectifying the complaint by making the geyser functional within 48 hours, complete all as specified and directed. Notes:- (i). Cost of minor spare parts like screws, nut, bolts, washers, wire, fuse, indicating lamp etc shall be deemed included in the unit rates. However, S&F of other spare parts shall be measured and paid separately. (ii). Technician should be equipped with all tools & plants like tester, multi-meter, etc as per site requirement .(iii). The Mechanic/Electrician complaints shall be attended and rectified as soon as possible but not more than 48 Hrs of handing over of complaint slip. However, certain complaints, if declared as urgent by the Engineer-in-Charge shall be attended and rectified by the contractor on the same day. Violation of this time line shall attract a penalty of Rs 250.00 per complaint per day on the contractor. Total in Figures 0.0 0.0 INR Zero Only 4.0 Construction of chamber for 100mm sluice plates item5 10.0 Nos Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information |