| 1 | S & F in repair for synthetic wooven flooring carpet of approved coloured weight 1.5kg/sqm fixed with approved rubber base adhesive as in floors complete all as specified and directed by Engr-in-Charge. |
| 2 | S & F in repair for 1.5mm thick PVC sheets laminated approved coloured marble mosaic or molted finish etc. laid with rubber based adhesive in floors and skirtings etc complete all as specified and directed by Engineer-In- Charge. |
| 3 | S & F in repair for wooden coloured interlocking tiles 1215 X 168 X 8 mm thick rectangular in floor/ dado laid over existing floor with foam sheet of approved best quality including joint/ polished end covering strip complete all as specified and directed by Engineer-In- Charge. |
| 4 | Dismentling unframed timber in fillets,rails,posts,rafter ,purlin etc under 40 Sqcm in section complete all as specified and as directed by Engineer-in-Charge. |
| 5 | S&F plain fillets squre,rectangular or triangular in section clean sawn secured with nails of 2nd class hard wood sectional area exc 3 Sqcm and not Exc 6 Sqcm, but bullnosed, splayed,chamfered or rounded on one edge or face complete all as specified and as directed by Engineer-in-Charge. |
| 6 | S&F plain fillets squre,rectangular or triangular in section clean sawn secured with nails of 2nd class hard wood sectional area exc 13 and not Exc 25 Sqcm complete all as specified and as directed by Engineer-in-Charge. |
| 7 | M & L for preparing new or previously untreated of wooden and applying two coats of synthetic enamel paint over incl a coat of red oxide over 10 cm in width or girth complete all as specified. |
| 8 | Dismantling wall and ceiling board,of any description and incl old batterens complete all as specified and as directed by Engineer-in-Charge. |
| 9 | M&L for 12 mm thick prelaminated particle board interior grade, prelaminated one side with decorative choice lamination and other side balancing white lamination, fixed with screws to frame work as in ceiling/Walls, complete all as specified and directed by Engr-in-Charge. Note:-( The rates are include to taking down and refixing electrical fitting and fixture proparly in working condition) |
| 10 | S & F hollow PVC panel joint type (with core, tongue) of 4 to 6 mm thick termite resistance, in approved colour golssy finish fixed with screws and incl battern for fame 300 C/C. Nails or adhesive on wooden/PVC/metal battens fixed on wall, complete all as specified and directed by Engr-in-Charge. |
| 11 | Dismantling floor, hearth or wall tiling including cement mortar bedding(but not backing), removing serviceable tiles to store and rubbish off the permises complete all as specified and directed by Engineer-In- Charge |
| 12 | M&L 25 mm thick PCC type B-0, (1:2:4) using 12.5mm graded stone aggregate as in levelling course for flooring complete all as specified and directed by Engineer-in-Charge. |
| 13 | M&L for coloured Non - skid Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exce 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15mm thick screed bed in cement mortar 1:4 complete all as specified. |
| 14 | M&L for coloured Non - skid Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exce 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 10mm thick screed bed in cement mortar 1:3 complete all as specified. |
| 15 | Demolition of exisiting damaged stone /Brick /Concrete Block masonary built in cement mortar including all quoins, arches, pillars etc complete all as specified and as directed by Engineer-in-Charge. |
| 16 | M&L for abour for random rubble stone masonary, uncoursed well bounded, bedded and soilidly hearted in cement mortar (1:4) completed all specified and directed by Engineer-in-Charge. |
| 17 | Taking down old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead complete all as specified and directed by Eng-in-Charge. |
| 18 | M&L rendering 15mm thick plaster on other than face fair face of brick work in CM 1:4 and surface finished even and fair complete all as specified. |
| 19 | M&L for rendering 15 mm thick cement mortar (1:6) on fair faces of stone masonary wall surfaces, complete all as specified and directed by Eng-in-Charge. |
| 20 | M&L for two coats of oil bound distemper on walls on newly plastered surfaces over 1 mm thickness wall care putty including preparation of surfaces by brooming or by steel wire brushing, complete all as specified by Engineer-in-Charge. |
| 21 | Preparation of new plaster surface of wall and applying two coat of cement base paint over a coat of primer complete all as specified. |
| 22 | M&L for PCC 1:2:4 type B1 (using 20 mm graded stone aggregates) as in lintels upto 1.5m clear span, cills, steps; seismic and other similar parapets and railings, copings, kneelers, apex stones, bed plates, slightly rounded or chamfered angles and throating, as directe incuding necessary formwork required including in repair complete all as specified and as directed by EIC. |
| 23 | M&L for chipping of unsound/deteriorated up to 50mm average thickness from slabs, beams, columns, chajja etc with manual chisel including tapering of all edges including cleaning of exposed concrete surface and reinforcement with wire brushes etc and disposal of debris complete all as specified and as directed. |
| 24 | Identifying and marking carefully the damaged reinforced concrete by tapping with light hammer and chipping of unsound weak concrete and plaster material from slabs/beams/columns etc. with power/hand driven chisel as directed by the engineer-in-charge upto 40 mm average depth including saw-cutting of all edges making square shoulders of the cavities complete all as specified and as directed.Note :- (i) All loose unsound and cracked concrete shall be removed out side MD land.(ii) Thickness will be measured excluding plaster |
| 25 | Providing mixing and applying over reinforcement bars zinc antirust agent as per specification of make 'Fosroc Nitozinc Primer STD Base' or equivalent in SIKA / Thermax / FOSROC complete all as specified and directed. |
| 26 | M&L mixing and applying SBR latex modified cement mortar 25 mm thick in cement sand mortar in proportions of 1:3 (1 cement and 2 graded quartz aggregate) with polymer admixed in proportions as approved, including trowelling with wooden tools on prepared concrete surfaces of parent material complete all as specified and as directed.Note :- SBR latex will be paid for separately. |
| 27 | Supply only approved SBR latex from FOSROC/BASF/DR FIXIT/ SIKA for bonding coat/Polymer modified cement mortor.Note: Rate will be in terms of solid contents of polymer. Please Enable Macros to View BoQ information |