| 1 | Earth work in excavation by mechanical means (hydraulic excavator) in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sidesand ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed, within a lead of 50 metres All kinds of soil |
| 2 | Demolishing brick work manually/by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 meters lead as per direction of Engineer-in-charge In cement mortar |
| 3 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) |
| 4 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) |
| 5 | Providing & laying water proofing treatment to vertical and horizontal surfaces of depressed portions of W.C., kitchen & the like consisting of:(i) Ist course of applying cement slurry @ 4.4 kg/sqm mixed with water proofing compound conforming to IS 2645 in recommended proportions including rounding off junction of vertical and horizontal surface.(ii) IInd course of 20 mm cement plaster 1:3 (1 cement: 3 coarse sand) mixed with water proofing compound in recommended proportion including rounding off junction of vertical and horizontal surface.(iii) IIIrd course of applying blown or residual bitumen applied hot at 1.7 kg. Per sqm of area.(iv) IVth course of 400 micron thick PVC sheet. (Overlaps at joints of PVC sheet should be 100 mm wide and pasted to each other with bitumen @ 1.7 kg/ sqm). |
| 6 | Providing and laying in position specified grade of reinforced cement concrete including curing but excluding the cost of centering, shuttering, finishing and reinforcement. All works upto plinth level 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 7 | Reinforced cement concrete work in walls (any thickness) including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts upto floor five level including curing but excluding cost of centering shuttering, finishing and reinforcement 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 8 | Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15°, landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto five level including curing but excluding the cost of centring, shuttering, finishing and reinforcement with 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 9 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto all level Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 10 | Centering and shuttering including strutting, propping etc. and removal of form for Foundations, footings, bases of columns etc. for mass concrete. |
| 11 | Centering and shuttering including strutting, propping etc. and removal of form for Lintel, beams, plinth beams, girders, bressumers and cantilevers. |
| 12 | Centering and shuttering including strutting, propping etc. and removal of form for Suspended floors, roofs, landings, balconies and access platforms. |
| 13 | Centering and shuttering including strutting, propping etc. and removal of form for Edges of slabs and breaks in floors and walls Under 20 cm wide |
| 14 | Brick work with common burnt clay (non-modular) bricks of class designation 7.5 in foundation and plinth including curing in Cement mortar 1:4 ( 1 cement : 4 coarse sand) |
| 15 | Half brick masonry with common burnt clay (non-modular) bricks of class designation 7.5 in foundations and plinth including curing in : Cement mortar 1:4 ( 1 cement : 4 coarse sand) |
| 16 | Providing and laying of Cement concrete flooring 1:2:4 (1cement: 2 coarse sand: 4 graded stone aggregate) including curing complete, 40 mm thick with 20mm nominal size stone aggregate. |
| 17 | Providing and fixing 1st quality ceramic glazed floor tiles conforming toIS : 15622 (thickness to be specified by the manufacturer ) of approved make in all colours, shades except burgundy, bottle green, black of anysize as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete. |
| 18 | Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, laid on 20 mm thick cement mortar 1:4 (1Cement : 4 Coarse sand), including grouting the joints with white cement and matching pigments etc., complete In colour such as White, Ivory, Grey, Fume Red Brown |
| 19 | 12mm Cement plaster of mix: 1 : 6 ( 1 cement : 6 coarse sand) |
| 20 | Providing and applying white cement based putty of specified thickness, of approved brand and manufacturer, over the plastered wall surface toprepare the surface even and smooth complete 2 mm thick |
| 21 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade on New work (two or more coats) over and including priming coat with water thinnable cement primer |
| 22 | Making soak pit 2.5 m diameter 3.0 meter deep with 45x45 cm dry brick honey comb shaft with common burnt clay (non modular) bricks of class designation 7.5 bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design. |
| 23 | Finishing walls with acrylic smooth exterior paint of required shade on New work (Two or more coats applied @ 1.67 liter/10sqm over and including priming coat of exterior primer applied @ 2.20kg/10sqm) |
| 24 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer-in-charge Internal work-exposed on wall, including fixing the pipe with clamps at 1.00 meter spacing 20mm nominal outer dia pipes. |
| 25 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer-in-charge Internal work-exposed on wall, including fixing the pipe with clamps at 1.00 meter spacing 25mm nominal outer dia pipes |
| 26 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer-in-charge External work including trenching, refilling etc 25mm nominal outer dia pipes |
| 27 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer-in-charge External work including trenching, refilling etc 32mm nominal outer dia pipes |
| 28 | Providing and fixing on wall face un-plasticized Rigid PVC rain water pipes conforming to IS: 13592 Type A including jointing with seal ring of pipe etc complete as directed by EIC |
| 29 | 150mm dia Pipe |
| 30 | 150mm dia PVC plain bend |
| 31 | 110mm dia Pipe |
| 32 | 110mm dia PVC plain bend |
| 33 | 110mm dia PVC Door Bend |
| 34 | 110mm dia Tee |
| 35 | PVC Pipe 75mm dia |
| 36 | PVC floor trap 75mm |
| 37 | PVC P-trap 100mm |
| 38 | PVC Door bend 75mm |
| 39 | PVC Plain bend 75mm |
| 40 | 75mm dia Tee |
| 41 | Providing and fixing of brick masonary manholes 450mmx450mm incluidng PVC cover with frame, plaster and concrete base all complete. |
| 42 | Providing and fixing 15 mm nominal bore C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms. |
| 43 | Providing and fixing 15 mm nominal bore C.P. brass bib cock of approved quality conforming to IS : 8931 |
| 44 | Providing and fixing 15 mm nominal bore C.P. brass angle valve for basin mixer and geyser points of approved make conforming to IS : 8931 |
| 45 | Providing and fixing PTMT grating of approved quality and colour Circular type 125 mm nominal dia with 25mm waste hole |
| 46 | Providing and fixing PTMT soap dish holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements,weighing not less than 106gms. |
| 47 | Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fitting arrangement of approved quality and colour 600 mm long towel rail with total length of 645 mm, 78 mm wide and effective height of 88 mm, weighing not less than 190 gms. |
| 48 | Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing Rectangular shape 453x357 mm |
| 49 | Providing and fixing un plasticized P.V.C. connection pipe with PTMT nuts, collars and bush of approved quality and colour 15 mm nominal bore with 45 cm length. |
| 50 | Providing and fixing of 35 liter water heater Geyser of approved make Racold, Havells, Cropmton or equivalent make as directed by EIC. |
| 51 | Providing & Fixing of Exhaust fan of approved make like (Havells, Orient, Crompton) including all necessary fittings all complete Job. |
| 52 | Providing and fixingTank Nipple of approved quality, complete 20 mm nominal bore |
| 53 | Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete 20 mm nominal bore |
| 54 | Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 liter low level white P.V.C. flushing cistern, including flush pipe with manually controlled device (handle lever), conforming to IS:7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required W.C. pan with ISI marked white solid plastic seat and lid. |
| 55 | Providing and fixing water closet squatting pan (Indian type W.C. pan) with 100 mm sand cast Iron P or S trap, 10 liter low level white P.V.C. flushing cistern, including flush pipe (of approved make) with manually controlled device (handle lever) conforming to IS: 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required White vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests. |
| 56 | Supplying fixing installtion and commissioning of 1.00 HP water mortor of approved brand like Crompton Greaves, KSB or equivalen including all necessary fittings and connections complete. |
| 57 | Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x 350 mm and 340x410 x265mm sizes respectively. |
| 58 | Providing and fixing wash basin with C.I. brackets, 15mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever required White Vitreous China Wash basin size 630x450 mm with a single 15 mm C.P. brass pillar taps. |
| 59 | Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings. |
| 60 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflowpipes but without fittings and the base support for tank |
| 61 | Providing / fixing powder coated aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z- sections and other sections of approved make conforming to IS :733 and IS :1285, fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC / neoprene felt etc. aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, aluminium snap beading for glazing / paneling, C. P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer in charge (including glazing and paneling)for shutters of doors, windows & ventilators including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of PVC / neoprene gasket required including all fittings complete 16 guage |
| 62 | Engagement of labour skilled/ unskilled for various dismantling works like tacking of floors, damaged tiles, etc including stacking of serviceable material as directed by EIC and disposal of unserviceable material up to 50 mtr lead. |
| 63 | Labour |
| 64 | Plumber |
| 65 | Mason |
| 66 | Welder |
| 67 | Heir charges of welding set including welding rod complete. |
| 68 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth and curing complete |
| 69 | TECHNICAL SPECIFICATIONS FOR PRE-FAB STRUCTURE MADE UP OF STEEL AND PUF PANELLS IN WALLS WITH ATTACHED TOILET.Pre-Fabricated shelter made up of steel structure and PUF panels, colour coated profile sheets etc with technical specification as given below:-1. Design Parameter.a) Seismic=Zone Vb) Wind / snow load as per relevant IS codes for the regionc) Temperature Range=(-) 40 to (+) 50 Cd) Roof slope= 1:2e) Dimensions. All as indicated in the reference drawing to be provided as site or as directed by EIC at site.2. Technical Specifications.a) Details of Structural Members. The steel structure for the shelters will be designed for the Designed Parameters. All structural steel will be ISI marked with manufacturer’s test certificate for raw material and structural properties. The main columns ,verandah rafters, trusses, purlins etc will be Made out of steel sections , MS plates, M S bolts / nuts etc (the size of steel sections / thickness of M S plates, size of bolts/ nuts will be as per drawings or as directed by EIC at site.b) The roof will be provided with 0.50mm thick Pre-colour coated steel profile sheets. Sheet covering will be fixed with using hot dip zinc coated self drilling hexagonal washer head fasteners. Ridge shall be covered by 0.50mm thick Pre-colour coated steel sheet. The sheets shall be laid with minimum end and side lap of 150mm.c) Gable End. Gable End will be covered with same panels as of wall upto bottom chord of truss. The triangular truss portion will be covered with 0.50mm wider than the width of the opening. |
| 70 | d) Roof Projection. The roof will have minimum projection 450mm to 600mm all around including verandah portion. Purlins will also be extended in the roof at the eaves and at gable roof extension (outside the structure)e) Main walls & partition walls.The main and partition walls will be made up of 60 mm thick wall Panels having height of 3.0 mtrs of make Llod panel system /Modern Panels/Jindal Mectecnol/PSL Engineering or equivalent. The Panels will be made of 0.50mm thick hot dipped galvanized steel sheets on both sides with 60mm thick layer of rigid CFC free close cell polyurethane foam (Density 40 Kg+2 Kg/Cum) insulation. The wall panels will be provided with tongue and groove joint continuous panelling systems for interlocking. All materials required for the manufacture of shelter will be new and shall comply with relevant Bureau of Indian Standard Specification. Base channel of specified size will be provided for walls.The PUF insulation material in the panel will have fire retarding and self extinguishing properties as per any international standard B2 DIN 4102 Part-I/BS-4735 Self Ext.f) Ceiling. The false ceiling of Gypsum board size 600x600 mm thickness 7mm with all fittings etc Tile:- Vitrified tile flooring size 600x600mm incluidng grouting the joint with cement and matching pigment etc laid in 40mm thick cement concrete flooring with mix 1:2:4 complete Job. |
| 71 | Carriage of material by mechanical transport including all loading / unloading complete |
| 72 | Sand Aveg. lead of 20 Km |
| 73 | Stone Aggrigate upto 40mm and above Aveg. lead of 20 Km |
| 74 | Stone Aggrigate below 40mm Aveg. lead of 20 Km |
| 75 | Bricks Aveg. lead of 20 Km |
| 76 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular type switch, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required Anchor/ GM/Legrand/Crabtree or equivalent make |
| 77 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required (as per Schedule)Finolex/Polycab/Anchor/V-Guard/Havells/RR kabel or equivalent make |
| 78 | 2 x 2.5 Sqmm + 1 x 2.5 sqmm |
| 79 | 2 x 4 sqmm + 1 x 4 Sq.mm |
| 80 | 2 x 10 sqmm + 1 x 6 Sq.mm |
| 81 | Supplying and fixing of modular blanking plate on the existing modular plate & switch box excluding modular plate etc as required |
| 82 | Supplying and fixing of suitable size GI box with modular plate and cover in front on surface or in recess, incliding providing and fixing of 3 pin 5/6 modular socket outlet and 5/6A modular switch, connections etc as required Anchor roma plus/ GM/Legrand/Crabtree or equivalent make |
| 83 | Supplying and fixing of suitable size GI box with modular plate and cover in front on surface or in recess, incliding providing and fixing of 6 pin 15/16A modular socket outlet and 15/16A modular switch, connections etc as required Anchor roma plus/ GM/Legrand or equivalent make |
| 84 | Supplying and fixing following way horozontal type three pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/recess,complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, inter connections, powder painted including earthing etc as required Havells/Anchor/SSK/legrand/hager/indoasian or equivalent make. |
| 85 | 16 way |
| 86 | Providing and fixing of following type of MCB's/switch gear of L&T/Havells/Anchor/ Schnedier/Legrand/ indoasian or equivalent make of 10 KA or more capacity series including testing and necessary terminations Havells/Anchor/SSK/legrand/hager/indoasianor equivalent make. |
| 87 | 63 A SPN |
| 88 | 6A-32A MCB's |
| 89 | Providing and fixing of M.S kiosks box weather proof with proper locking arrangement and inbuilt bus bar of 100 A capacity and switch gear cut out as per BIS standards including laying of foundation and proper grouting of kiosks box in ground. |
| 90 | Providing and fixing of 100 A Isolator single phase 240V with allied accessories of Havells/Schneider/ Indoasian/ Anchor/ optipro/L&T make |
| 91 | Providing and fixing of 100W LED Flood Light including necessary terminations |
| 92 | Providing and laying of 2 - core 25 Sq.mm aluminium cable 1.1KV Grade 60 of Havells/Finolex /Polycab/ rallison /anchor/KEI make for mains supply including connectors to be routed along with the wall and fixed in steel clamps/ saddle and in pvc ISI mark heavy conduit if laid underground etc from mains and pannel. |
| 93 | Providing and fixing of LED lights of following type Crompton/Phillips/Orient/syska/Panasonic or equivalent make or equivalent make including necessary terminations as required. |
| 94 | 9 Watt LED Lamps |
| 95 | Providing and fixing of Angle/straight holders including terminations GM/Havells/Krant /Anchor/Great white make |
| 96 | Providing and fixing of 35 Litre Geyser including necessary terminations |
| 97 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 98 | Supplying and laying 25 mm X 6 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) |
| 99 | Providing and fixing of 250/300mm Exhaust fans crompton/orient /anchor/usha or equivalent make including necessary terminations as required. Please Enable Macros to View BoQ information |