| 1 | Excavation in trenches not exceeding 1.50m wide and not exc 1.50m in depth and getting out in soft / loose soil complete all as specified and directed. |
| 2 | All as per srl item No 1.00 but depth exc 1.50 m but n. exc 3m |
| 3 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified and directed. |
| 4 | Removing surplus excavated soil to a distance n.exc 50 metre and n exc 100 metre and depositing where directed at a level n.exc 1.5 m above the stafrting point complete all as specified and directed. |
| 5 | M&L for PCC (1:2:4), type B2, using 40mm graded crushed stone aggregate as in foundation filling and mass concrete complete all as specified and directed. |
| 6 | M&L for RCC M-30 (Design Mix) using 20mm graded crushed stone aggreate as in foundation including column footing and plinth beams complete all as specified and directed. |
| 7 | M&L for RCC M-30 (Design Mix) using 20mm graded crushed stone aggregate Walls, retaining walls, basement walls, ballast walls and the like; any thickness; above top of footings; including attached pilasters and buttresses complete all as specified and directed. |
| 8 | M&L for RCC M-30 (Design Mix) using 20mm graded crushed stone aggregate slab supported on walls, beams and column in floors, roofs landings, balconies canopies, deck slab and in shelves and the like complete all as specified and directed. |
| 9 | M&L for form work for rough finished surfaces to sides of concrete foundation, footing base of columns, raft & raft beams, plinth beams, sides and soffits & similar works verical or to batter complete all as specified and directed. |
| 10 | M&L for formwork to faces of walls, retaining walls, abutments, parapets and staircase railings and similar work including attached pillasters, buttresses, etc. vertical or to batteretc rough finished surface of concrete complete all as specified and directed. |
| 11 | M&L for formwork to soffits of suspended slab such as roof slab, floor slab, landing and similar works n.exc. 200mm thick (Horizontal or sloping) etc. for rough finished surface of concrete complete all as specified and directed. |
| 12 | M&L for deformed or TMT bars 10mm dia and over of grade Fe-500 D , cut to length bent to shape required including cranking, bending and binding with and including mild steel wire annealed not less than 0.9mm dia complete all as specified and directed. |
| 13 | M&L for 15mm thick rendering in cement mortar 1:4 on fair faces of brick work surace rendering is to be even and smooth with out using extra cement complete all as specified and directed. |
| 14 | S&F 150mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls complete all as specified and directed. |
| 15 | S&F 100mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls complete all as specified and directed. |
| 16 | M&L for hard core for loose filling, of gauge 40 to 80 mm in soakage pit/well complete all as specified and directed. |
| 17 | M&L for gravel bed for loose filling of size 3.0 to 10.0mm complete all as as specified and directed. |
| 18 | Moorum/red bajri filling in floors or pavings, laid in layers n exc. 15 cm thick, spread, levelled and rammed including watering complete all as specified and directed. |
| 19 | M&L boring holes in soft/loose soil for incasing GI Tubing 300 mm pipe etc complete all as as specified and directed |
| 20 | S&F 150 mm GI slotted pipe with 3.16mm slot size pipe for inserting in hole etc complete all as as specified and directed |
| 21 | S&F for pipe cap of 150 mm bore complete all as as specified and directed |
| 22 | M&L Framed work such as grills, gratings etc., with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; cooler stand framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe 290 or E-165 |
| 23 | M&L for providing precast cement concrete (1:2:4) type B1, using 20mm graded crushed stone aggregate as in roof kerbs or mud stops, rounded or chamfered on edges in lintels upto 1.5m clear span,cills, steps, seismic and other similar bands, plinth courses, string courses , lacing courses, parapits and railings upto 60cm in height, copings/bed block, kneelers, apex stones, bed plates, kerbs not provided and the like including weathering slightly rounded or chamfered angles and throating complete all as specified and directed. |
| 24 | M & L for providing cement concrete 1:2:4 type B-2 concrete, using 40mm graded stone aggregate as in water throughs, surface channels and drains and benching including finishing the top of benching even and smooth using extra cement complete all as specified and directed. |
| 25 | Extra for forming fair finished drain or channel 30cm inner girth in cement concrete using extra cement including forms, moulds mitred/stopped, end etc complete all as specified and directed. |
| 26 | Demolition of brick/stone masonry built in cement/lime mortar of any mix including all quoins pillar ashlars masonry and removal complete all as specified & directed. |
| 27 | M&L brick work with fly ash 'brick straight or curved on plan exc 6m mean radius built cement mortar 1:6 complete all as specified and as directed. |
| 28 | M&L for walling of random rubble, bedded and solidely hearted Uncoursed built in CM (1:6) complete all as specified and directed. |
| 29 | Taking down cement plaster any description on brick or stone walls etc complete all as specified and directed. |
| 30 | Demolition Mud in roofs, any thicknes, including plastering , existing tretement and cleaning (whether full thickness removed or only or part there of) etc in all respect and preparing it for further treatment and taking out and disposal of debris & rubbish to a distance exc 1 Km but not exc 1.5 Km complete all as specified & directed. |
| 31 | M&L Cutting out cracks to V-section in existing roofs or terracing, cleaning out, wetting, grouting with cement and sand slurry 1:3 complete all as specified & directed. |
| 32 | M&L precast cement concrete 1:2:4 type B-1 (using 20 mm graded stone aggregate) set in cement mortar 1:6 as in coping of brick masonry wall kneelers, apex stones, pier caps, columns, posts, boundary pillars, bed plates, pintle blocks, ancho-rage blocks, bonders (for stone wallin) corbels, brackets, etc. including weathering slightly rounded or chamfered angles and throating as directed including necessary formwork complete all as specified & directed |
| 33 | M&L for PCC 1:2:4 type B0 (using 12.5 mm graded crushed stone aggregate) as in roof padding, laid to a minimum consolidated thickness of 25 mm as leveling course, laid and compacted in min slope 1:30 over roof complete all as specified & directed. |
| 34 | M&L 15mm thick screed bed in CM 1:4 with water proofing compound over green concrete surface(WPC will be measured and paid seperately) surface finished even and smooth (without using extra lime or cement) complete all as specified & directed |
| 35 | Supply only Integral waterproofing compound complete all as specified and directed. |
| 36 | M&L Applying evenly a tack coat of industrial bitumen 85/25 at the rate of 1.2 kg per sq. m including cleaning surfaces over bituminious primer complete all as specified & directed |
| 37 | M&L APP based plymeric membrane minimum weighing 3 Kg/Sqm and minimum 3 mm thick reinforced with polyster non woven fabric (wt not less than 150 gms/sqm) land on primed surface by forced application complete all as specified and directed. |
| 38 | M&L for applying bitumious aluminium paint @ 0.15 kg per Sqm over bituminous layer in two coats complete all as specified and as directed. |
| 39 | S&F Rotational moulded polyethylene water storage tanks of 500 Ltrs capacity (cylindrical vertical with closed top) hoisted in complete necessary fittings i.e. nipple, union, socket, reducer, tank nipple etc and fixed in position all as specified in SSR Part I including dismantling water tanks complete all as specified & directed |
| 40 | S&F in repair ball valves brass high pressure with polythelene float and fly net complete, screwed , iron pipes 20 mm dia complete all as specified & directed |
| 41 | Taking up or down 15mm steel tubing and connections, complete all as specified & directed |
| 42 | Taking up or down 20mm steel tubing and connections, complete all as specified & directed |
| 43 | S&F steel tubing medium grade 15mm bore with all fittings fixed complete to wall and or laid in floor complete all as specified & directed |
| 44 | S&F steel tubing medium grade 20mm bore with all fittings fixed complete to wall and or laid in floor complete all as specified & directed |
| 45 | S&F in repair brass Gun-metal, globe or gate valves 20mm dia with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed. |
| 46 | S&F in repair PVC (SWR) pipes 110 mm bore single socketed in any length with rubber ring joints fixed to walls complete all as specified & directed |
| 47 | S&F M.S. frame work such as grills, gratings, angle frame etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks, cooler stands and similar work conforming to Fe.290.Gde-E-165 a coat of red oxide primer after preparation of steel surfaces complete all as specified and directed. |
| 48 | M & L for preparation of newly plastered surfaces of walls and applying two coat of exterior emulsion apex paint (exterior grade) over one coat primer over 1 mm putty on walls complete all as specified & directed. |
| 49 | M & L for complete removal of existing treatment on walls and preparation of surfaces of walls and applying two coat of exterior emulsion apex paint (exterior grade) over one coat primer over 1 mm putty on walls complete all as specified & directed. |
| 50 | M&L writing letters or figures (Block, roman, Italic or Indian letter n.exc 30cm high) complete as specified and directed Please Enable Macros to View BoQ information |