| 1 | Supply, erecting and fixing in true vertical position Steel tubular swaged poles (9.0 metres long) complete with cast iron base plate, finial taper plug,bolts,nuts & screws as specified type 410 SP-31, complete all as specified. Note : - Earth work & PCC work will be measured & paid seprately under relavent item. |
| 2 | Dismantling of ACSR conductor any size complete all as specified and directed. |
| 3 | Restringing of old ACSR conductor / earth continuity conductor by unbinding the conductor from the insulators, stringing the conductor to the extent to avoid over sag, binding the conductors to insulators with aluminium binding wire (max five conductor per span of length upto 35m) complete all as specified and directed. |
| 4 | M&L for Pin insulator polymor white, 100 mm height, 65 mm dia for 1100 volts grade complete all as specified. |
| 5 | M&L for Shackle Type polymor insulator including galvanised mild steel straps, washers insulator bolts, washers and nuts of height 100 mm, max dia 115 mm,section of straps 31x5 mm,dia of bolts 14 mm all as specified and directed by Engr-in-charge. |
| 6 | Material and labour for ACSR conductor of required size for O/H lines, on HT poles, including stringing and binding wire, complete all as specified & directed. |
| 7 | M&L for MS work confirming to Fe-410-O or Fe-310-O as in cross arms, support, bracings, stiffeners, clamps channels fabricated from structural steel including nuts, bolts and washers welding, bending cold or hot drilling holes for bolts in any shape or size all as directed including two coats of aluminium paint over a coating of red oxide primer all as directed by Engr-In-Charge. |
| 8 | Supply and fix in replacement LED street light fitting 45 Watts, having powder coated pressure die cast aluminium housing with IP 66 efficient, protection with heat resistant toughned glass with individual LED lenses complete including making connection with street light box or OH line using PVC insulated and sheathed single core multi stranded alumn conductor cable of size 1.5 sq mm complete all as specified and directed by Engr in Charge. |
| 9 | S&F GI Bracket made out of 40 mm dia medium grade pipe 1.5m length to shap for fixing on pole and suitable for all type of street light with 02 Nos clamps of flat iron (40 x4mm) nuts, bolts and washers including painting with two coats of aluminim paint over a coat of primer complete all as specified and directed. |
| 10 | M&L for Energy saving enviromental friendlylong life aesthetically designed aluminium landscape IP 65 Bamboo LED bollard with polycarbonate diffuser 8W Height not less than 2 feet including necessary connection with suitable size of copper cable complete all as specified and as directred. |
| 11 | S&F FR /PVC pole box for loop in and loop out of size 200mm x 180 mm including 3 pole and Neutral bakelite connector and one SP (6-10) MCB and necessary fixing arrangements complete all as specified and directed. |
| 12 | S&F for sub main wiring with 2 runs of FRLS PVC insulated multistrand, copper conductor cable of size 1.5 Sqmm along with one run of 1.5 sqmm PVC insulated cable 1100 volts multi stranded copper conductor as earth wire in and including PVC conduit incl taking down old one complete all as specified and directed. |
| 13 | M&L for Painting to exposed surfaces of LT Steel tubular pole with one coat of synthetic enamel paint of complete pole and up to 1 mtr height from ground level with 3 strip of yellow colour synthetic enamel paint and two strip of black synthetic paint including preparation of old painted surface, complete all as specified and directed by engr-in charge. |
| 14 | Material & labour for PCC 1:4:8, type D2 ( using 40 mm graded crushed stone aggregate) as in base for foundation of the pole, all as specified and directed. |
| 15 | Material & labour for Providing PCC 1:3:6, type C2 (using 40 mm graded crushed stone aggregate) as in mass filling all as specified and directed. |
| 16 | Material & labour for providing PCC 1:2:4 type B1 (Using 20 mm graded crushed stone aggregate) for plinth coping all as specified and directed. |
| 17 | M&L for Cutting the existing PCC/ Road for passing of UG Cable in road crossing and making good the disturbed surface of road to its original specification complete all as directed. |
| 18 | Excavation in trenches, n.exc 1.5m wide & n.exc 1.5m in depth for foundation etc in Hard and Dence soil & getting out for laying of cable complete all as specified & directed. |
| 19 | Excavation in trenches, n.exc 1.5m wide & exc 1.5 m in depth but n.exc 3.0m in depth for foundation etc in Hard and Dence soil & getting out for laying of cable complete all as specified & directed. |
| 20 | Returning filling in including spreading leveling watering & well ramming in layers n exc. 25cm Cum thick. |
| 21 | Removing of surplus excavated soil to a distance n.exe 50 Mtr and depositing where directed at a level n.exe 1.5 mtr above the starting point complete all as specified. |
| 22 | Material and labour for sand in trenches as in cushioning to under ground cable spreading, levelling hand punning complete all as specified and directed.Note- Punned down thickness will be measured for payment purpose complete all as specified and directed. |
| 23 | Supply and laying unreinforced pre cast concrete cable cover class LV type I flat size 250x150x40mm all as specified and directed. |
| 24 | S&F AIl in One Solar Street Light 20 watt is made with High Efficiency Mono Crystalline Solar PV Module, Lithium Ferro Phosphate battery with in-built BMS technology High Efficacy LED MPPT Solar Charge Controller and Aluminium Extruded body & is specially progrmmed to automatically control the dimming and brightness of light which increases the backup time. |
| 25 | M&L for stay assembly complete with stay plate bow, stay rod of dia 16mm and gavanised iron stay wire stranded of size 7/4mm and accessories as shown in electric plate No 1 of SSR part - I (loop type insulator, stay clamps, excavation and concrete shall be measured separately) complete all as spd and directed. |
| 26 | M&L for 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core cable flat or circular stranded conductor size of 10 sqmm, including taking down old wire complete all as specified. |
| 27 | Supply, installation, commissioning and testing bus chamber factory made Out door Wall Mount type complete 8 way with 100 Amp rated aluminium bus bar for 3 phase 4 wire |
| 28 | Supply and lay PVC insulated, heavy duty, LT XLPE galvanised steel strip armoured electric power cable of size 25 Sqmm x 4 core with stranded aluminium conductor 1100 Volts grade, jointed with cable glands, lugs etc., laid in trenches/drawn through pipe, with and including taking down old unserviceable cable, complete all as specified and directed.Note :- Excavation and earth work shall be mearured and paid under respective items. |
| 29 | All as per item srl No 28 above but of size 16 sqmm 4 core nominal cross section complete, 1100 volts. |
| 30 | All as per item srl No 28 above but of size 16 sqmm 2 core nominal cross section complete, 1100 volts. |
| 31 | All as per item srl No 28 above but of size 35 sqmm 3.5 core nominal cross section complete, 1100 volts. |
| 32 | All as per item srl No 28 above but of size 50 sqmm 3.5 core nominal cross section complete, 1100 volts. |
| 33 | S & F (in repair) Timer Switch with sensor alongwith pre-down swiching off timer (nature switche), Three phase. Contactors, 3 nos. Incoming MCBs & 3 nos. Outgoing MCBs of 40 Amps each & Circuit wiring (Copper) of min.10 sq.mm operating illumination level for switching ON should be less than 60 lux for 30 seconds and for switching off must be greater than 10 lux for 30 seconds, multiple option switch for automatic and manual operations, capable to handle lightning load up to 5 KW per phase, including Power contactor capacity 16/20 Amp per phase conforms to IEC 60947-4-1, IS 13947-4-1 completely enclosed with plastic body panel conforming to IP 66 degree of protection complete all as specified and directed. Make : Kakatiya Energy systems Pvt Ltd, Model No SWADEEP- 02EC5kW3P or equivalent. |
| 34 | Material and labour for earthing complete with galvanised steel earth plate 600 x 600 x 6 mm buried directly in ground vertically to a depth not less than 2.25 metre below normal ground level with top edge of the earth plate at a depth not less than 1.5 metre below ground level connected to and including GI wire of size 4 mm dia by means of nuts, bolts, washers etc made of and connected to test point and earth dolly as all shown in electrical plate No.3 of SSR Part-I 2009 and specified or indicated including excavation and earth work in any type of soil PCC (1:3:6) type C1 in chamber, pre cast RCC slab 50mm thick in cement concrete (1:2:4) type B1, reinforced with welded steel wire fabric or XPM jali (weight not less than 4.0 kg/Sqm) with cast iron frame, funnel, with wire mesh, 20mm bore light grade GI watering pipe, lugs, 15mm bore light grade GI protection pipe, test point etc complete all as specified and as directed. Note: (i) Item includes the cost of 7.5 m GI pipe for protection of earth lead. (ii) Item includes the cost of 7.5 m GI earth lead. |
| 35 | Deduct Schedule of Credit of Rs (-) 52700.00 (Minus) as listed in Schedule 'A' (Contd). Contract Sum shall be arrived after deducting the credit amount.Note :- Tenderers will not quote against this item being a firm amount. Please Enable Macros to View BoQ information |